| 1 | Lump sum price worked out by the contractor for \"BUILDING WORKS\"as listed in Schedule ‘A’ Part-I representing percentage (+ or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 21 |
| 2 | Lump sum price worked out by the contractor for \"SITE CLEARANCE, EXCAVATION & EARTH WORK\"as listed in Schedule ‘A’ Part-II representing percentage (+ or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 22 |
| 3 | Lump sum price worked out by the contractor for \"INTERNAL WATER SUPPLY\"as listed in Schedule ‘A’ Part-III representing percentage (+ or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 23 |
| 4 | Lump sum price worked out by the contractor for \"INTERNAL ELECTRIFICATIONS\" as listed in Schedule ‘A’ Part-IV representing percentage (+ or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 26 |
| 5 | Lump sum price worked out by the contractor for \" HARD STANDING\" as listed in Schedule ‘A’ Part-V representing percentage (+ or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES B/F from Sl page No. 27 |
| 6 | Lump sum price worked out by the contractor for \" AREA DRAINAGE\"as listed in Schedule ‘A’ Part-VI representing percentage (+ or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 28 |
| 7 | Lump sum price worked out by the contractor for \" SECURITY WALL FENCING AND STEEL GATE\" as listed in Schedule ‘A’ Part-VII representing percentage (+ or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES B/F from Sl page No. 30 |
| 8 | Lump sum price worked out by the contractor for \"External Water Supply\"as listed in Schedule ‘A’ Part-VIII representing percentage (+ or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 31 |
| 9 | Lump sum price worked out by the contractor for \"EXTERNAL ELECTRIFICATION\"as listed in Schedule ‘A’ Part-IX representing percentage (+ or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 34 |
| 10 | Lump sum price worked out by the contractor for \"SEWAGE DISPOSAL\"as listed in Schedule ‘A’ Part-X representing percentage (+ or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 36 |
| 11 | Sch \"A\" PART-XI (MISCELLANEOUS ITEMS) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under respective schedule. |
| 12 | Supply, installation, testing, and commissioning of a 9.81 kWp grid-connected rooftop solar PV system utilizing 144-cell Bifacial Mono Crystalline Half-Cut PERC modules rated at 545 Wp per module, coupled with a 10 kWp string inverter for high-efficiency energy conversion. The system includes a robust galvanized iron mounting structure designed to optimize sunlight exposure and withstand wind speeds up to 150 km/h. Additional components include high-quality DC and AC cables, DC and AC distribution boxes with surge protection devices, copper-bonded earthing, lightning arrestors, and ISI-marked UPVC conduits for cable routing. The setup integrates an internet-based remote monitoring system and bi-directional net metering to enable seamless energy management and monitoring. The project ensures compliance with IEC standards, and commissioning support to promote efficient and reliable solar energy generation for long-term sustainability, complete as per below specifications: |
| 13 | (i) Solar PV Module-545 Wp, 144 Cells Bifacial Mono-Crystalline Half Cut PERC Solar PV Module. Testing certification & approval as per IEC 61215, IEC 61730, IEC 61701, IEC 62109-9.81Kwp(ii) DC to AC Converting String Inverter- Grid Connected String Type Inverter. 415-440 V AC, 3- Phase, 50 Hz.- 1No(iii) Module Mounting Structure- GI Structure raised at suitable angle on Rcc roof for modules mounting (min height 7 feet in south side and 9 feet in north side ,structure lag size 50*50 mm, purlin Size 40*40 mm ,Rafter Size 50*50 mm) -1 Set(iv) Data Monitoring System- Internet based Online Remote Monitoring system. Momentary, Daily & Cumulative power generation can be monitored in Desktop / Laptop / Mobile - 1 Set |
| 14 | (v) DC Cable (PV Module to Inverter)- 4 Sqmm Copper Flexible Cable, 1000 V, Solar Grade UV Treated & UV Resistance, Double Insulated- 50M(vi) AC Cable (ACDB to Client’s LT Panel)- 10 Sqmm 4 Core Copper Cable 1100 V AC.- 20 M |
| 15 | (vii) AC Distribution Panel Box - With Suitable Size of MCB. - 1 No(viii) DC Distribution Panel Box (DCDB) -2 in 2 out 1000 v DC SPD-1 Nos(ix) MC4 Connector-TUV Approved, IP-65, UV Resistant. As required(x) Earthing-17 mm Dia, 1 metre Depth, Copper bonded Earth Electrode with BFC Compound Earthing Chamber and Marker. GI Strip, Zink Spray and Bituminus Paint protection- 2 Nos(xi) Lightening Arrestor- Hollow type Copper rod spike type 1 No |
| 16 | (xii) Piping/ Conduits for DC & AC Cables.- Cables will be laid under ISI marked electrical grade UPVC Rigid conduits As required(xiii) Meters- Solar Meter And Net Meter-1 Set |
| 17 | M&L for Supply of approved earth obtained from outside the proposed land including transportation and cost of earth including Spreadingwell remming, watering and levelling in layers n exc. 25 cm thickas required complete all as specified & directed. |
| 18 | Provisioningon hire besis of utilityVehiclesfour wheeler (Bolero Camper/Scorpio Gateway of Mahendra/TATA Xenon/ISUZU D Max) non AC in good conditionPetrol/Diesel driven with & including driver & adequate fuel requiredto be engaged as per requirement for supervision of work by Engg-in Charge/JEs from GE Office to work site & back including liason with CWE/CE Office etc.NOTE:- The rate quoted shall be for 300 KM running in one day. |
| 19 | Add or deduct from item No 14 above for over or under 300KM for per KM when vehicle runs more than or less than 300 KM in a day @ Rs 15/- per KM complete allas directed. |
| 20 | Notes:-For Srl item No 14(a) The engagement timing of vehicles shall be as decided by GE as per requirement of work. (b) For Srl item No 14.01 extra milage over or under from 300 KM per day running of vehicle shall be adjusted (extra to be paid or lesser to be recovered)under Srl item No 14.01 respectively.(c) Fuel, oil, lubricant including complete vehicle maintenance shall be responsibility of the contractor. The vehicles will be kept in good running condition and both exterior & interior shall be neat, clean and well maintained.(d) In the event of failure to provide vehicles or being off the road for maintenance or due to breakdown or some other reason, the contractor will substitute & arrange to provide another equivalent vehicle immediately otherwise a recovery of Rs. 5000/Day will be recovered from contractors RAR/Bill payments. Proper record of such break down/off road vehicle/failure to supply veh for particular day (s) shall be maintained and signed by GE. (e) Contractor will maintain day to day logbook of vehicles duly signed by GE/AGE. |
| 21 | (f) Payment of these items shall be made to contractor alongwith RARs due for work done progress irrespective of the fact whether payment to vehicles owner or driver made by contractor at any periodicity/monthly or otherwise.(g) Running of PC vehicle and utility vehicle shall be restricted to 4000KM per month per vehicle. The running of any vehicle beyond this limit per month shall only be permitted with prior approval of CWE.(h) Vehicles shall not be engaged on Sunday and Gazetted Holidays without prior written approval of Garrision Engineer. |
| 22 | M&L for steel gate 4.5 metre wide with 1.5 Mtr wicket Gate in double leaf including pillars in brick/stone masonary,excavation and earth work in hard rock, painting to steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified, shown on Drg No CEJZ/TD/13 Sht 1/2.&2/2 |
| 23 | Supply and fix surface-mounted lamp holder suitable forLED bulb, complete with a polycarbonate body for durability and safety.The holder shall be fixed properly on the wall or ceiling surface using appropriate hardware, and connected using three-core copper conductor cable (overall sheathed, 1.5 Sqmm) passed through PVC flexible conduit, from the ceiling rose to the fitting complete all as specified and directed. |
| 24 | S&F Metal Clad Plug and socketwith box20 Amp with MCB complete fixed properly on wall surface with the provisioning of suitable sizes of bolts, nuts, washer and to connect by using cable PVC insulated copper stranded conductor of size 4 Sqmm as per specification as per dirteced |
| 25 | M&L Sub main wiring with single core FRLS PVC insulated and unsheathed multistranded, FRLS copper conductor cable 1100 volts grade drawn through and incl 20 mm size of ofPVCconduit accessories andall fixed/laid concealed in the surface of walls/ceilings, fittings on wall. Cable required for connection to DBs shall deemed to be included and shall not be measured separately. Earth wire shall run inside the conduit. (a)02 runs 6 sqmm conductor cable and 01 run of 6 sqmm earth continuity conductor and 1run of conduit shall be measured as one length |
| 26 | Material and labour for sub main wiring with two single core FRLS PVC insulated unsheathed copper stranded conductor of size 4 Sqmm and one run of size 4 Sqmm for conteneous earthing connected to common earth dolly complete drawing in and including suitable size of PVC conduitwith all fittings and accessoriesall fixed/laid concealed in the surface of walls/ceilings, with clamp properly on wall or ceiling complete all as specified and directed. Note: 02 runs of 4 Sqmm conductor cable, 01 run of 4 sqmm earth continuity conductor cable and 1 one run of conduit shall be measured as one length |
| 27 | S&F surface mounting batten tube light fitting, integrated polycarbonate LED channel with white acrylic cover complete suitable for and including lamp LED 1x20 Watt,(4 feet) fixed properly on wall surface and connecting complete from ceilling rose to fitting by three core copper conductor cable of overall sheathed size 2.5 Sqmm which shall be passed through PVC flexible conduit all as directed. |
| 28 | S&Fbuilding security light LED fitting with lamp 35 watt 230V AC outdoor type with high pressure die cast aluminum housing and heat resistant , epoxy powder coated dark graphite grey colour finish and prismatic polycarbonate cover with individual LED lences suitable for including bracket for building security light fittings of any size made out of GI pipe medium grade 32 mm dia 1.25 mtr length withprovision of clamps and fittings in position and two coat of aluminum paint over a coat of red oxide primer all as specified and directed |
| 29 | Supply and install hi wall split AC units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5TR including S&F voltage stablizer for automatic operation single phase, naturally air cooled indoor type designed for input variation of 4 KVA complete all as specified and directed |
| 30 | Supply, Install, testing and commissioning of LT panel from CPRI tested firms, outdoor type totally enclosed with front opening hinged doors with projected top and raised platform of suitable size weather, dust, vermin and water proof made out of CRCA sheet 3.15 mm thick including aluminium bus bar for 3 phase, 415 volts of capacity 200 Amps and half neutral sleeved with coloured sleeves insulation complete painting with powder coated paint including marking by paint of outgoing supply to various locations for identifiaction for the following :- |
| 31 | (a)Phase indicator lamps (R-Y-B) LED type(b)MCCB FP, 100 Amps 16 KA - 1 No (I/C)(c)MCCB FP, 63 Amps 16 KA - 1 No (O/G) (d)MCB SPN, 0-32 Amps 10 KA - 2 Nos (O/G) (e)Digital Ameter 0-100 Amps (f)Digital voltmeter 0-500 Volts.(g) Spare compartment - 01 No (for MCCB)(h) Onload change over switch 100A, 4P - 01 No |
| 32 | Supply and fixing bracket for Street light fittings of any size made out of GI pipe medium grade 40/50 mm dia 1.5 mtr length bend to required size and shape including provision of clamps and fittings in position and two coat of aluminum paint over a coat of red oxide primer all as specified and directed |
| 33 | S&F MS Pole box having protective category of IP 66, factory made, weather/ vermin proof door opening and locking arrangement made out of 3mm thick MS sheet with bakelite connector 4 way 40 Amps fixed on 3mm thick bakelite sheet and one No MCB 6 Amps,SP, 240 Volts of 10 KA to control street/ security light in MS DIN rail and MS box fixed to Steel/RCC pole with MS clampof size 20x3 mm, nuts bolts and washers including painting with textured polyester paint complete all as specified and directed. |
| 34 | Supply and connect PVC insulated unsheathed copper conductor cable 2.5 Sqmm multi-stranded 1100 volt grade three core for connecting street light fitting complete all as specified and directed.(NOTE :- One run of three core cable shall be measured as one length) |
| 35 | M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 10cm after laying of cable in trenches complete all as directed and sand cover to under ground cable complete all as specified and directed. Note: only punned thickness will be measured for payment purpose. |
| 36 | S & F submersible pumpset horizontal (openwell type) having cap 1 HP electric driven, AC, 230 Volts, 50Hz complete all as specified and directed. |
| 37 | S&F single phase pump starter suitable for 1HP complete all as specified and directed. |
| 38 | Supply and fix submersible cable flat type copper conductor of size 2.5 Sqmm 3 Core complete all as specified and directed. |
| 39 | M&L for drilling/tapping of existing pipe line (PHED Jodhpur) and fixing of suitable size MS clamp having 20mm dia pipe for jointing of GI tubing complete all as specified and directed. |
| 40 | Supply and fix gun metal mechanical water flow meter at tapping point and the meter shall be fixed 40mm dia GI tubing complete all as specified and directed. |
| 41 | M&L for construction of brick masonary (230 mm thick wall) valve pit of size 900 x 900 x 1000mm inner dimension including necessary earth work, PCC 1:4 :8, 75 mm thick Type D-2 using 40 mm graded stone aggregate as in foundation, brick wall built in CM 1:6, rendering 15 mm thick with CM 1: 6, rendering 15 mm thick with CM1:6externally upto 15 CM below GL and CM 1:4 internally and providing MS Sheet cover 3.15 mm thick welded with hinges including necessary locking arrangement and complete all as specified and directed and as shown in drawing |
| 42 | Supply only of Compost manure incl loading unlaoding & transportation & stacking at site complete . The compost shall be of uniform texture relatively dryof dark brown or black color & should have an non offensive earth like odour. It shall be nutrient rich soil like material created by the biological decomposition of organic material such as vegetative debris & live stock manurecomplete all as specified and directed. (The net measurement of the compost manure shall be arrived at by reducing the actual stack measurements by 8%). |
| 43 | Supply only of chemical fertilizer in bags |
| 44 | Urea / Ammonium Sulphate |
| 45 | Bone Meal |
| 46 | Potassium Sulphate or Murate of Potash |
| 47 | Supply only insecticide/herbicide of approved make Chloropyriphos 35%EC orMonocrotophos 30% EC |
| 48 | Supply only of good earth (sand) from outside MD Land free from kankar, stones, cobbles,Moorum, shingle, Rocks building rubbish etc of all kinds & suitable foragricultuer/arboricultuer purpose. The ph of the soil brought shall be of the range6 to 8.50.(The net measurement of the compost manure shall be arrived at by reducing the actual stack measurements by 20%). |
| 49 | Supply & planting of treesat desired distances in rows or other patterns to provide a green cover to the areain the following stages.(a) Excavating pits of size 75 cm dia & depth 75-80 cm taking out the soil & keeping aside .(b) Removing the stones, cobbles, boulders, vegetation etc from the excavated soil & mixing the balance excavated earthwith a mixture of good earth & compost manure( Supplied vide item no 4 & 1 above)mixed @ 4:1 & filling the mixture so obtained in layers in the excavated post hole aroud thesaplingTogether with watering & supporting the plant/tree sapling with a bamboo /wooden stake & tieing with two ties all as directed for the following tree/plants |
| 50 | Amaltas ( Cassia Fistula) Ht of Sapling 1.20 to 1.50 m |
| 51 | Gulmohar ( Delonix Regia) Ht of Sapling 1.20 to 1.50 m |
| 52 | Ashoka Tree ( polyalthai longifolia ) Ht of Sapling 1.20 to 1.50 m |
| 53 | Ficus benzaminHt of Sapling 1.20 to 1.50 m |
| 54 | Prep of the Thavlas ( dressed pits for trees) of size 75 cm dia & upto a depth of 10 cm from top by upturning the soil for aeration removing weeds/stones kankars if any & flooding the pits with water complete & removal of the ubbish outside def land. ( this operation shall be carried after 30 days of the planting of the tree/sapling . |
| 55 | Supply & fixing tree guards 45 cm dia and 1.50 m high fabricated with 3 No. FI(of size 35x3mm at bottom & 25x3 in the middle & top) welded with MS welded mesh of wt not less than 4 kg/sqm & 3 legs of 12 mm dia MS bars 400 mm long all as per attached sketch with 02 coats of syn enamel paint over a coat of red oxide primer. |
| 56 | M & L for Cyndan Dactylon having rhizomes with sufficient nodes in row of 5 cm apart in either direction & watering, maintenance oflawn till the it forms a thick layer free from weeds & fit for mowing incl spreading of good earth & compost. |
| 57 | Supplying and laying unreinforced precast concrete cable cover, class LV, type 2 flat, of size 250mm x 150mm x 40mm ISImarket (IS-5820-1970) complete all as specified and directed. |