Indian Tenders

Tender Notice

TDR 54303710
Tendering Authority Military Engineer Services
Tender No CWE (A) JODH/GE (A) NO. 02- OF 2025-26(82526/26/E8)
Tender ID 2026_MES_754307_1
Tender Brief Corrigendum : Tender For Construction Of Building For Echs Polyclinic Type D At Shergarh (Non Military Station) Under Ge (Army) No. 02 Jodhpur
City jodhpur
State Rajasthan
Document Fees INR 1000 /-
EMD INR 207000.0 /-
Tender Value INR 1.32 Crore /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender For Construction Of Building For Echs Polyclinic Type D At Shergarh (Non Military Station) Under Ge (Army) No. 02 Jodhpur

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 24-03-2026 CorrigendumNo.01 Date 15-04-2026

Key Dates

Publish Date 24-03-2026
Last Date of Bid Submission 15-04-2026
Tender Opening Date 17-04-2026

Contact Information

Company Name Military Engineer Services
Contact Person CWE ARMY JODHPUR
Address CWE ARMY MULTAN LINE ARMY AREA JODHPUR-342010

BOQ Items

Name of Work: CONSTRUCTION OF BUILDING FOR ECHS POLYCLINIC TYPE \"D\" AT SHERGARH (NON MILITARY STATION) UNDER GE (ARMY) NO. 02 JODHPUR
Sl. No. Item Description
1Lump sum price worked out by the contractor for \"BUILDING WORKS\"as listed in Schedule ‘A’ Part-I representing percentage (+ or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 21
2Lump sum price worked out by the contractor for \"SITE CLEARANCE, EXCAVATION & EARTH WORK\"as listed in Schedule ‘A’ Part-II representing percentage (+ or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 22
3Lump sum price worked out by the contractor for \"INTERNAL WATER SUPPLY\"as listed in Schedule ‘A’ Part-III representing percentage (+ or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES B/F from Sl page No. 23
4Lump sum price worked out by the contractor for \"INTERNAL ELECTRIFICATIONS\" as listed in Schedule ‘A’ Part-IV representing percentage (+ or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 26
5Lump sum price worked out by the contractor for \" PARKING SHED & HARD STANDING\" as listed in Schedule ‘A’ Part-V representing percentage (+ or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES B/F from Sl page No. 27
6Lump sum price worked out by the contractor for \"SEWAGE DISPOSAL\"as listed in Schedule ‘A’ Part-VI representing percentage (+ or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 29
7Lump sum price worked out by the contractor for \" AREA DRAINAGE\"as listed in Schedule ‘A’ Part-VII representing percentage (+ or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 30
8Lump sum price worked out by the contractor for \" BOUNDARY WALL & STEEL GATE\" as listed in Schedule ‘A’ Part-VIII representing percentage (+ or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES B/F from Sl page No. 32
9Lump sum price worked out by the contractor for \"External Water Supply\"as listed in Schedule ‘A’ Part-IX representing percentage (+ or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 33
10Lump sum price worked out by the contractor for \"EXTERNAL ELECTRIFICATION\"as listed in Schedule ‘A’ Part-X representing percentage (+ or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES B/F from Sl page No. 34
11Sch \"A\" PART-XI (MISCELLANEOUS ITEMS) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as \"Rs 0.00\" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under respective schedule.
12Supply, installation, testing, and commissioning of a 10 kWp grid-connected rooftop solar PV system utilizing 144-cell Bifacial Mono Crystalline Half-Cut PERC modules rated at 545 Wp per module, coupled with a 10 kWp string inverter for high-efficiency energy conversion. The system includes a robust galvanized iron mounting structure designed to optimize sunlight exposure and withstand wind speeds up to 150 km/h. Additional components include high-quality DC and AC cables, DC and AC distribution boxes with surge protection devices, copper-bonded earthing, lightning arrestors, and ISI-marked UPVC conduits for cable routing. The setup integrates an internet-based remote monitoring system and bi-directional net metering to enable seamless energy management and monitoring. The project ensures compliance with IEC standards, and commissioning support to promote efficient and reliable solar energy generation for long-term sustainability, complete as per below specifications:
13(i) Solar PV Module-580-595 Wp, 144 Cells Bifacial Mono-Crystalline Half Cut PERC Solar PV Module. Testing certification & approval as per IEC 61215, IEC 61730, IEC 61701, IEC 62109-10Kwp(ii) DC to AC Converting String Inverter- Grid Connected String Type Inverter. 415-440 V AC, 3- Phase, 50 Hz.- 1Nos(iii) Module Mounting Structure- GI Structure raised at suitable angle on Rcc roof for modules mounting (min height 7 feet in south side and 9 feet in north side ,structure lag size 50*50 mm, purlin Size 40*40 mm ,Rafter Size 50*50 mm) -1 Set(iv) Data Monitoring System- Internet based Online Remote Monitoring system. Momentary, Daily & Cumulative power generation can be monitored in Desktop / Laptop / Mobile - 1 Set
14(v) DC Cable (PV Module to Inverter)- 4 mm2 Copper Flexible Cable, 1000 V, Solar Grade UV Treated & UV Resistance, Double Insulated- 50M(vi) AC Cable (ACDB to Client’s LT Panel)- 20M
15(vii) AC Distribution Panel Box - With Suitable Size of MCB. - 1 Nos DC Distribution Panel Box (DCDB) -2 in 2 out 1000 v DC SPD-1 Nos(viii) MC4 Connector-TUV Approved, IP-65, UV Resistant.(ix) Earthing-17 mm Dia, 1 metre Depth, Copper bonded Earth Electrode with BFC Compound Earthing Chamber and Marker. GI Strip, Zink Spray and Bituminus Paint protection- 2 Nos(x) Lightening Arrestor- Hollow type Copper rod spike type 1 Nos
16(xi) Piping/ Conduits for DC & AC Cables.- Cables will be laid under ISI marked electrical grade UPVC Rigid conduits(xii) Meters- Solar Meter And Net Meter-1 Set
17M&L for Supply only approved earth obtained from outside the Defence land including transportation and cost of earth and deposited as directed including Spreading and levelling in layers n exc. 25 cm thick includingwell ramming watering as required complete all as specified & directed.
18Provisioningon hire besis of utilityVehiclesfour wheeler (Bolero Camper/Scorpio Gateway of Mahendra/TATA Xenon/ISUZU D Max) non AC in good conditionPetrol/Diesel driven with & including driver & adequate fuel requiredto be engaged as per requirement for supervision of work by Engr-in Charge/JEs from GE Office to work site & back including liason with CWE/CE Office etc.NOTE:- The rate quoted shall be for 300 KM running in one day.
19Add or deduct from item No 14 above for over or under 300KM for per KM when vehicle runs more than or less than 300 KM in a day complete allas directed.
20Notes:-For Srl item No 15(a) The engagement timing of vehicles shall be as decided by GE as per requirement of work. (b) For Srl item No 15 extra milage over or under from 300 KM per day running of vehicle shall be adjusted (extra to be paid or lesser to be recovered)under Srl item No 16 respectively.(c) Fuel, oil, lubricant including complete vehicle maintenance shall be responsibility of the contractor. The vehicles will be kept in good running condition and both exterior & interior shall be neat, clean and well maintained.(d) In the event of failure to provide vehicles or being off the road for maintenance or due to breakdown or some other reason, the contractor will substitute & arrange to provide another equivalent vehicle immediately otherwise a recovery of Rs. 5000/Day will be recovered from contractors RAR/Bill payments. Proper record of such break down/off road vehicle/failure to supply veh for particular day (s) shall be maintained and signed by GE. (e) Contractor will maintain day to day logbook of vehicles duly signed by GE/AGE.
21(f) Payment of these items shall be made to contractor alongwith RARs due for work done progress irrespective of the fact whether payment to vehicles owner or driver made by contractor at any periodicity/monthly or otherwise.(g) Running of PC vehicle and utility vehicle shall be restricted to 4000KM per month per vehicle. The running of any vehicle beyond this limit per month shall only be permitted with prior approval of CWE.(k) Vehicles shall not be engaged on Sunday and Gazetted Holidays without prior written approval of Garrision Engineer.
22M&L RCC coventional septic tank designed to carry sewage & sullage water for 50 users, excavation in any type of soil, PCC 1:4:8 below foundation, RCC M-30 design mix in walls, base slab, baffle walls & roof slab including beams etc with vent shaft, mainhole opening with cover connection etc complete with effective depth of 1.5mtr & overall depth of 3.0 mtr complete all as shown in drawing.
23M&L soakage well size of 2.4mtr dia X 3.0 mtr effective depth, excavation in any type of soil, foundation in PCC (1:3:6), walls of honeycombed masonry with top ring of M-25 concrete including intersepting chamber & screen chamber made of brick masonry in CM (1:6), RCC cover slab in M-25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats complete all as shown in drawing.
24M&L for steel gate 5.5 metre widein double leaf including pillars in brick/stone masonary,excavation and earth work in hard rock, painting to steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified, shown on Drg No CEJZ/TD/13 Sht 1/2.&2/2
25Supply and fixing LED Solar street light fitting 24 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete all as specified and directed by Engr-in-charge.
26M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth wire protected by galvanized iron40 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of strata, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.
27NOTES :(a)The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC M25 design mix using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I.(b) Item includes the cost of 7.5 M GI pipe for protection of earth wire. Any variation in length shall be adjusted through deviation order.(c) Item includes cost of 7.5 M earth strip. Any variation in length shall be adjusted through deviation order.(d) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
28M&L for Rubber mat of 1 meter x 2 meter x 19 mm complete all as specified and directed.
29Supply, install and commissioning of factory made vermin proofMain LT panel -1Outdoor, self supported, CPRI Approved make, front and rear openable, double door hinged type with locking arrangement and slopping top canopy, suitable protection with dust and vermin proof etc, fabricated out of 3.15 mm thick CRCA sheet duly powder coated with 7 tank chemical process, mounted fixed on and included MS angle section 50 x 50 x 6 mm on PCC 1:2:4 type B-1, plateform 60 CM above the ground level and 45 CM below the ground level, factory fabricated with front andback openable double door system with andlock openable by keys, having chromium plated 19 mm dia fancy lock, louvers and air vent, gasketincludingfollowing:- (MAIN PANEL )
30(a) Bus bars of copper strips of 200 Amp current rating capacity, minimum 600 mm long or of length as actually required at site for 3 phase and half size for neutral, mounted on epoxy/FRP bus bar insulator - 01 set(b) MCCB 160 Amps TPN 35 KA, 415 V having reputring capacity - 01 No. for incoming.(c) MCCB 4 pole, 63 Amps, 415 Volt, AC,16KA= 03 Nos (O/G) (d)MCCB 63 Amps TPN 25 KA, 415 Vhaving reputring capacity - 03 for outgoing.(TPN DB -02 nos & Pump panel)(e) MCB 32 Amps TPN \"C\" type, 230 V - 02 for outgoing(f) Spare compartment for MCCB - 01 No.(g)Amp meter with CT\"S and selector switch digital type 0 to 500 Amps - 01 No(h)Volmeter with inbuilt selector switch digital type 0 to 500 Volts -01 No(j)LED type indicator lamp Red/Yellow/Blue colour-03 Nos(k)Internal wiring with copper conductor incl necessary lugs and thimbles 1 Job
31M & L for LT cable route indicator including angle iron stand and PCC etc complete all as specified and directed.
32Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete.
33Supply, install and commissioning of factory made vermin proofLT panel(for Pump House) Outdoor, self supported, CPRI Approved make, front and rear openable, double door hinged type with locking arrangement and slopping top canopy, suitable protection with dust and vermin proof etc, fabricated out of 3.15 mm thick CRCA sheet duly powder coated with 7 tank chemical process, mounted fixed on and included MS angle section 50 x 50 x 6 mm on PCC 1:2:4 type B-1, plateform 60 CM above the ground level and 45 CM below the ground level, factory fabricated with front andback openable double door system with andlock openable by keys, having chromium plated 19 mm dia fancy lock, louvers and air vent, gasketincludingfollowing a) AL bus bar 100 Amps cap 4 wire fixed on insulator not less than 1.0 mtr long bus bar -1 set
34a) Incoming MCCB 63 Amps, 4 pole, 415 Volts AC having rupturing capacity 25 KA - 01No( For Incomming )b) OutgoingMCCB 4 pole, 32 Amps, 415 Volt, AC,16 KAwith thermal magnetic release -03 Nos (for Pump-02 & Spare)(c) Space for DOL Starter suitable for 415 V AC For 3 HP Motor-02 Nos(d) Digital Voltmeter 0 - 500 volt of size 96 x 96 mm square with selector switch -01 Nos. (e) Indicator Lamp LED type(R-Y-B) with holder-01 set of three.f) Ammeter 0 to 150Amp with selector switch & suitable range of CTs
35M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 10cm after laying of cable in trenches complete all as directed and sand cover to under ground cablecomplete all as directed. Note:- only punned thick ness will be measured for payment purpose.
36M&L for construction of valve pit of size 600 cm x 600 cm x 600 mm internal dimentions complete all as specified and directed.
37Supply, install, testing and commissioning for self priming monobloc pump set of 5 HP having minimum discharge not less than 500/LPM, head range not less than 36 mtrs with brass impeller,3 phase,50 cycle,415 volts star delta connected, copper wound induction motor, including base frame, PCC foundation, nut, bolts,3 core copper flat cable of suitable size length from pump set to starter complete all as specified and directed. . (01 Working+ 01 standby)
38Supply and fix foot valve, ISI marked confirming IS:4038,50 mm dia flange type complete all as specified and directed.
39Cutting the existing water supply DI/GI pipe line 100 mm dia and taking branch connection of 50 MM dia pipe by inserting Tee complete all specified and as directed
40Supply and fix air cooled split unit air conditioner electric driven, single phase of capacity of 2.0 TR, BEE 5 star rated complete all specified and as directed
41Supply and fix air cooled split unit air conditioner electric driven, single phase of capacity of 1.5 TR, BEE 5 star rated complete all specified and as directed
42Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all specified and as directed
43Supply and fix surface-mounted lamp holder suitable forLED bulb, complete with a polycarbonate body for durability and safety.The holder shall be fixed properly on the wall or ceiling surface using appropriate hardware, and connected using three-core copper conductor cable (overall sheathed, 1.5 Sqmm) passed through PVC flexible conduit, from the ceiling rose to the fitting complete all specified and as directed
44S&F Metal Clad Plug and socketwith box20 Amp with MCB complete fixed properly on wall surface with the provisioning of suitable sizes of bolts, nuts, washer and to connect by using cable PVC insulated copper stranded conductor of size 4 Sqmm complete all specified and as directed
45M&L Sub main wiring with single core FRLS PVC insulated and unsheathed multistranded, FRLS copper conductor cable 1100 volts grade drawn through and incl 20 mm size of ofPVCconduit accessories andall fixed/laid concealed in the surface of walls/ceilings, fittings on wall. Cable required for connection to DBs shall deemed to be including and shall not be measured separately. Earth wire shall run inside the conduit. (a)02 runs 6 sqmm conductor cable and 01 run of 6 sqmmas earth continuity conductor.
46Material and labour for sub main wiring with two single core FRLSPVC insulated unsheathed copper stranded conductor of size 4 Sqmm and one run of size 4 Sqmm for conteneous earthing connected to common earth dolly complete drawing in and including suitable size of PVC conduitwith all fittings and accessoriesall fixed/laid concealed in the surface of walls/ceilings, with clamp properly on wall or ceiling as per specifiedas directed
47Supply and fixing MCCB 4 pole 100 Amps 415 volts. 16kAAdjustableoverload setting l &fixed magnetic setting complete all specified and as directed
48S&F surface mounting batten tube light fitting, integrated polycarbonate LED channel with white acrylic cover complete suitable for and including lamp LED 1x20 Watt,(4 feet) fixed properly on wall surface and connecting complete from ceilling rose to fitting by three core copper conductor cable of overall sheathed size 2.5 Sqmm which shall be passed through PVC flexible conduit all as directed.
49S&Fbuilding security light LED fitting 35 watt 230V AC outdoor type with high pressure die cast aluminum housing and heat resistant , epoxy powder coated dark graphite grey colour finish and prismatic polycarbonate cover with individual LED lences suitable for including lamp LED 35 watt, fixed / connect properly at directed location on building with IP 65/66 protection complete all specified and as directed
50Supply and fixing bracket for building security light fittings of any size made out of GI pipe medium grade 32 mm dia 1.25 mtr length bend to required size and shape including provision of clamps and fittings in position and two coat of aluminum paint over a coat of red oxide primer complete all specified and as directed
51S & F urinal spreader of cast copper alloy,fancy type with chromium plated, screwed both ends for iron pipe or for unions, complete all as directed by Engineer-in-Charge. fixing with 15 mm dia pipe. (Minimum weight 60gms).
52S & F Health faucet (ABS Body) Brass chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified complete all as directed.
53S&Ffor15mmbib cock (long body)of chromiumplatedfancytype copperalloy screwed downhighpressure forironpipeorforunionsfixedcompleteallasspecifiedand directed.

Other Detail

Information Source https://defproc.gov.in/nicgep/app
Download FileName File Description File Size
Download d5b8ad10-15f5-46ae-b8d4-8bec229f908b.html Tender Documents 0 KB
Download BOQ_844879.xls Tender Documents 0 KB
Download TENDER26merged.pdf Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.