Tender Brief Corrigendum : Tender For Provision Of Deficient Married Accommodation For Sailors Pos And Below At Ins Rajali Arakkonam
City rajali
State Tamil Nadu
Document Fees INR 3000 /-
EMD INR 1500000.0 /-
Tender Value INR 19.50 Crore /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender For Provision Of Deficient Married Accommodation For Sailors Pos And Below At Ins Rajali Arakkonam

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 30-03-2026 DATECORRIGENDUM6 Date 15-04-2026
2 24-03-2026 DATECORRIGENDUM5 Date 08-04-2026
3 24-03-2026 DATECORRIGENDUM5 Date 08-04-2026
4 17-03-2026 DATECORRIGENDUM4 Date 01-04-2026
5 17-03-2026 DATECORRIGENDUM4 Date 01-04-2026
6 17-03-2026 DATECORRIGENDUM4 Date 01-04-2026
7 13-03-2026 DRGCORRIGEND2 Other 08-04-2026
8 13-03-2026 DRGCORRIGEND2 Other 15-04-2026
9 13-03-2026 DRGCORRIGEND2 Other 01-04-2026
10 11-03-2026 DRAWINGCORRIGENDUM2 Other 08-04-2026
11 11-03-2026 DATECORRIGENDUM3 Date 27-03-2026
12 11-03-2026 DRAWINGCORRIGENDUM2 Other 15-04-2026
13 11-03-2026 DATECORRIGENDUM3 Date 27-03-2026
14 11-03-2026 DRAWINGCORRIGENDUM2 Other 27-03-2026
15 11-03-2026 DATECORRIGENDUM3 Date 27-03-2026
16 11-03-2026 DRAWINGCORRIGENDUM2 Other 01-04-2026
17 11-03-2026 DATECORRIGENDUM3 Date 27-03-2026
18 03-03-2026 DATECORRIGENDUM2 Date 19-03-2026
19 03-03-2026 DATECORRIGENDUM2 Date 19-03-2026
20 03-03-2026 DATECORRIGENDUM2 Date 19-03-2026
21 03-03-2026 DATECORRIGENDUM2 Date 19-03-2026
22 03-03-2026 DATECORRIGENDUM2 Date 19-03-2026
23 20-02-2026 DATECORRIGENDUM1 Date 12-03-2026
24 20-02-2026 DATECORRIGENDUM1 Date 12-03-2026
25 20-02-2026 DATECORRIGENDUM1 Date 12-03-2026
26 20-02-2026 DATECORRIGENDUM1 Date 12-03-2026
27 20-02-2026 DATECORRIGENDUM1 Date 12-03-2026
28 05-02-2026 DRAWINGCORRIGENDUM Other 03-03-2026
29 05-02-2026 DRAWINGCORRIGENDUM Other 08-04-2026
30 05-02-2026 DRAWINGCORRIGENDUM Other 15-04-2026
31 05-02-2026 DRAWINGCORRIGENDUM Other 27-03-2026
32 05-02-2026 DRAWINGCORRIGENDUM Other 01-04-2026

Key Dates

Publish Date 05-02-2026
Last Date of Bid Submission 15-04-2026

Contact Information

Company Name Military Engineer Services
Contact Person CHIEF ENGINEER NAVY VISAKHAPATNAM
Address CHIEF ENGINEER NAVY STATION ROAD VISAKHAPATNAM

BOQ Items

Name of Work: PROVISION OF DEFICIENT MARRIED ACCOMMODATION FOR SAILORS [Pos AND BELOW] AT INS RAJALI ARAKKONAM
Sl. No. Item Description
1Schedule \"A\" Part – I to Schedule \"A\" Part – XVII:NOTE: Schedule \"A\" Part – I to Part – XVII are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
2Lumpsum price worked out by the contractor for \"Buildings & Structures\",as listed in Schedule \"A\" Part – I .
3Lumpsum price worked out by the contractor for \"Site Clearance / Earthwork/ Excavation\", as listed in Schedule \"A\" Part – II .
4Lumpsum price worked out by the contractor for \"Pile foundation\", as listed in Schedule \"A\" Part – III
5Lumpsum price worked out by the contractor for \"Internal Electrification\", as listed in Schedule \"A\" Part – IV .
6Lumpsum price worked out by the contractor for \"Internal Water Supply\", as listed in Schedule \"A\" Part – V .
7Lumpsum price worked out by the contractor for \"Sewage Disposal \",as listed in Schedule \"A\" Part – VI .
8Lumpsum price worked out by the contractor for \"External Water Supply\", as listed in Schedule \"A\" Part – VII
9Lumpsum price worked out by the contractor for \"External Electrification\",as listed in Schedule \"A\" Part – VIII
10Lumpsum price worked out by the contractor for Roads/Paths/Hard Standing\", as listed in Schedule \"A\" Part – IX .
11Lumpsum price worked out by the contractor for \"Area drainage\", as listed in Schedule \"A\" Part – X
12Lumpsum price worked out by the contractor for Fencing/ Gate\",as listed in Schedule \"A\" Part – XI
13Lumpsum price worked out by the contractor for \"Fire fighting and fire alarm system\", as listed in Schedule \"A\" Part – XII
14Lumpsum price worked out by the contractor for \"Lightning Protection\", as listed in Schedule \"A\" Part – XIII
15Lumpsum price worked out by the contractor for \"Aviation obstruction light\", as listed in Schedule \"A\" Part – XIV
16Lumpsum price worked out by the contractor for \"Rain water harvesting\", as listed in Schedule \"A\" Part – XV
17Lumpsum price worked out by the contractor for \"Arboriculture\", as listed in Schedule \"A\" Part – XVI
18Lumpsum price worked out by the contractor for \"Lifts\", as listed in Schedule \"A\" Part – XVII
19Schedule \"A\" Part - XVIII [Miscellaneous Items]
20PILE FOUNDATION
21M&L for RCC, M40 Grade, Design Mix [using 20 mm graded stone aggregates] as in piles and complete all as specified and as directed.Note:- Pile shall be casted as mentioned in drawings and as specified. However, for payment purpose the length of pile shall be measured up to cut off level only. The unit rate/ Lumpsum price quoted shall be deemed to include this aspect. Minimum cement content shall be not less 400 Kg/Cum
22Boring for bored cast in situ piles 900 mm dia in any type of soil/clay/soft rock except hard rock/fractured rock and getting out and disposal of spoil out side MD land using HYDRAULIC RIG complete all as specified and directed.
23Boring for bored cast in situ piles 900 mm dia in hard rock/fractured rock and getting out and disposal of spoil out side MD land using HYDRAULIC RIG complete all as specified and directed.
24Carrying out Initial load [Compression] test on 900mm dia piles, complete all as specified and directed.
25Carrying out Initial load [Lateral] test on 900mm dia piles, complete all as specified and directed.
26Carrying out routine load test [Compression] on 900mm dia piles, complete all as specified and directed.
27Carrying out routine load test [Lateral] on 900mm dia piles, complete all as specified and directed.
28Carrying out low strain integrity test on 900mm dia piles including analysing the results complete all as specified and directed.
29Boring for bored cast in situ piles 500 mm dia in any type of soil/clay/soft rock except hard rock/fractured rock and getting out and disposal of spoil out side MD land using HYDRAULIC RIG complete all as specified and directed.
30Boring for bored cast in situ piles 500 mm dia in hard rock/fractured rock and getting out and disposal of spoil out side MD land using HYDRAULIC RIG complete all as specified and directed.
31Carrying out Initial load [Compression] test on 500mm dia piles, complete all as specified and directed.
32Carrying out Initial load [Lateral] test on 500mm dia piles, complete all as specified and directed.
33Carrying out routine load test [Compression] on 500mm dia piles, complete all as specified and directed.
34Carrying out routine load test [Lateral] on 500mm dia piles, complete all as specified and directed.
35Carrying out low strain integrity test on 500mm dia piles including analysing the results complete all as specified and directed.
36Internal Electrification
37Point Wiring complete with 1100 Volts, FRLSH Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and 3 mm thick Hylam Sheet top cover for fixing switches, fittings, regulators etc concealed in walls, including 1100 Volts, FRLSH Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified.
38All as per Serial Item No. 33 above but One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified.
39All as per Serial Item No. 33 above but One 3 Pin Switch Socket Outlet 5 Amps on same Board complete all as specified.
40All as per item No.33 here-in-before but controlled by two two way switch complete all as specefied and directed.
41All as per Serial Item No. 33 above but one 3 Pin Switch Socket Outlet 16 Amps on independent board, with 1100 Volts, FRLSH grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694 and including 1100 Volts, FRLSH grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
42Supply and fixing of ceiling fan complete with blades, down rod and other accessories, AC 230 Volts, 1200 mm sweep, min air delivary 210 CFM with service value 6.00, BEE, 5 star rated with brushless direct current motor [BLDC] including connecting with 1.0 Sqmm, 2 core copper conductor from ceiling rose complete all as specified and as directed.
43Supply and fixing exhaust fan, 250mm sweep, plastic body, heavy duty with louvers, AC single phase, 230 volts, connection with 1.0 sqmm copper conductor flexible wire from ceiling rose including making necessary opening and making good the disturbed surface complete all as specified and as directed.
44Supply and fixing exhaust fan, 300 mm sweep, metallic body, heavy duty , AC single phase, 230 volts , 5 star rating, connection with 1.0 sqmm copper conductor flexible wire from ceiling rose including making necessary opening and making good the disturbed surface complete all as specified and as directed.
45S&F energy efficient LED Tube light fitting with tube 5W or nearest size, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED light fixture with extruded polycorbonate environmental friendly, energy efficient ready to use pack of complete mounting brackets including connecting up with 1.0 Sqmm 3 core flexible copper conductor cable complete all as specified as directed
46S&F energy efficient LED Tube light fitting with tube 10W or nearest size, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED light fixture with extruded polycorbonate environmental friendly, energy efficient ready to use pack of complete mounting brackets includingconnecting up with 1.0 Sqmm 3 core flexible copper conductor cable complete all as specified as directed
47S&F energy efficient LED Tube light fitting with tube 18/20W or nearest size, 240 Volts, 50 Hz, surface mounted, decorative ultra slim square profile LED light fixture with extruded polycorbonate environmental friendly, energy efficient ready to use pack of complete mounting brackets includingconnecting up with 1.0 Sqmm 3 core flexible copper conductor cable complete all as specified as directed
48S & F energy efficient LED security light fitting with tube 30 watts new generatiionenergy saving & environmental friendly long life, made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening separate driver compartment with IP66 protection pre-wired and connecting up with with 1.0 Sqmm copper conductor cable upto connector including 1.5 metre long GI tubing light grade bracket of 32 mm dia bend to shape for fixing on wall/ polewith suitable MS bracket nuts, bolts etc., complete all as specified and directed.
49Supply, Install, testing and commissioning of AC three phase static electronic meter of accuracy class 1.0, 240 Volts, 50 Hz, with backlite LCD display of rating 10-60 Amps six month historywith the following specifications complete all as specified and directed.[a] AC Three Phase Four wire, tamper proof, Static Meter of Class 1.0, 415 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC standards with incuilt 865-867 MHz Radio Frequency communication facility with self healing Mesh network with default and on demand display, biling data generation facility, anti-tamper features, Microprocessor and LED/LCD based circuitry.[b] Meter should support the following data: 30 Min instantaneous data for voltage, current, power factor, power, cumulative energy and frequency, 30 load survey data for energy, monthly billing survey for cumulative energy and Max Demand.[c] Meter should have connect/ disconnect functionally operable from prepaid billing software.[d] The meter should support open communication protocolDLMS with the software MAKE: Secure, L&T Schneider
50M & Lforsub-main wiring with 4.0 sqmm nominal area two single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 4.0 sqmmPVC insulated unshethed multi-stranded copper conductorcable for earth wiredrawn through 20 mm dia PVCconduit complete all as specified and as directed.Note :(i) Two run of 4.0 Sqmm + one run of 4.0 Sqmm as a earth wire cable + one run of PVC conduitshall be measured as an one Unit.
51Supply and fix polycarbonate meter box as per IS 14772 with IP -55 weather proof and temperature proof,fire retardant suitable for three phase smart pre-paid meter viewing glass, concealed hinge and earth bolt plugged including cable glands for incoming and outgoing cables and locking arrangement for top cover of the box without affecting communication complete all as specified and directed.
52M & Lforsub-main wiring with 10.0 sqmm nominal area four single core PVC insulated unshethed multi-stranded FRLS copper conductor cable including one 10.0 sqmmPVC insulated unshethed multi-stranded copper conductorcable for earth wiredrawn through PVCconduit of suitable size complete all as specified and as directed.Note :(i) Four run of 10.0 Sqmm + one run of 10.0 Sqmm as a earth wire cable + one run of PVC conduitshall be measured as an one Unit.
53S & F MCCB DB, vertical double door, TPN, 4 way, sheet steel, with 200 Amps rated bus bar, 415 Volts, 50 Hz, IP : 43 protection,concealed in walls, including provision of MCCB FP 40 Amps, 10 KA as incommer and outgoing circuits, filling the empty with blanks, making good the disturbed area as per existing surfacecomplete all as specified and as directed.
54S & F MCB DB, vertical double door, TPN, 6 way, sheet steel, , 415 Volts, 50 Hz, IP : 43 protection,concealed in walls, including provision for fixing RCBO, FP as incommer and outgoing circuits, MCB SP/TP filling the empty with blanks, making good the disturbed area as per existing surfacecomplete all as specified and as directed.
55Supply and fixing wall mounted fan, 450mm sweep,AC single phase, 230 volts, connection with 1.0 sqmm copper conductor flexible wire from ceiling rose, 5 star rating complete all as specified and as directed.
56Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part - I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and as directed.
57Internal Water Supply
58S & F 15 mm dia Bib taps, long body, fancy type, chromium plated screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
59S & F 15 mm dia Bib taps, long body, fancy type, chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
60S & F CP mixer for mixing hot and cold water fancy type, chromium plated,screwed down for pipe, with two outlets going (one for bib tap and other for shower) complete all as specified and as directed.
61S & F 15 mm dia bib tap two way, fancy type screwed down and fixed suitable for 16 mm outer dia CPVC pipe complete all as specified and as directed.Note: The maximum flow rate will be 03 LPM
62S & F 15 mm health faucet, chromium plated, fancy type with steel flexible complete suitable for 16 mm outer dia CPVC pipe complete all as specified and as directed.
63S & F CP mixer swan neck for mixing hot and cold water fancy type, chromium plated,fancy type screwed down for pipe, with two outlets going (one for hot and one for cold) kitchen complete all as specified and as directed.
64External water supply
65Supply, install, testing and commissioning of horizontal type open well submersible pump set electric driven 20 HP capacity,including star delta starter of appropriate rating , necessary PCC foundation for pump set and starter anlge iron base of suitable size for installation of the pump set also deemed to inclusive, suitable size of copper cable for connection of pump set (Starter should be fixed on panel) complete all as specified and directed.
66Supply and fix 3 core 16.0 sqmm FRLS armoured copper cable as per IS:1554to wall/ roof/ false ceiling/ floors with necessary clamps/ saddles all as specified and directed.
67Cutting the existing DI/MS pipe line of 150 mm dia for alterations or additions necessarily done in position without taking down and inserting Tee of 150 x 150 x 150 mm with and including the Tee for tapping complete all as specified and directed.
68Material and Labour for laying of Ductile Iron pipe with spigot and socket end centrifugally cast(spun) class K-9 of 150 mm dia pipe conforming to IS-8329 including testing and commissioning all as specified andas directed.
69Material and Labour for laying of Ductile Iron pipe with spigot and socket end centrifugally cast(spun) class K-9 of 100 mm dia pipe conforming to IS-8329 including testing and commissioning all as specified andas directed.
70Supply and fix double ball type air release valve of size 50 mm Complete all as specified and as directed.
71M & L for masonry valve chamber of size 1200 X 1200 X 1000 mm [interanl dimensions] comprising of 50mm thick PCC for valve including excavation and earth work in any type of soil and 200 mm thick PCC 1:4:8 type D2 foundation, brick work in CM (1:6) plastring internal surface 15 mm tick in CM (1:4) PCC (1:3:6) type B1 couping 50 x50x6 mm angle iron 3 mm thick MS plate cover complete with locking arrangement painting steel and iron surface with two coat of synthetic enamel paint over a coat of zinc chrome primer complete allas specified and as directed.
72Supply, install and testing of LT Panel board made out of CRCA sheet 2 mm thick Indoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 Aluminium bus bar with heat proof colour code, insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 200 A capacity complete with powder coating, necessary internal electric connection as requiredwith and inclusive of following items: (Pump House Panel)I/C (a) LT 440 volts3 phase, 4P, 4 wire 50 cycles, 25kA, Adjustable type MCCB of 100 Amp rated complete with overload protection, No-Volt thermal based release.-01 No(b) MCCB63 Amp 3P, 50 Hz, 415 Volts complete - 03 Nos (c) MCB C-Curve, 16 Amp SPN, 50 Hz, 240 Volts complete -01 Nod) LED Indicating Lamps for each phase with colour code Red Yellow Blue for R, Y and B Phases-01 [set of 03]
73External Electrification
74LT FPB made out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc., used are to be made of rust proof material including as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 3000 A capacity complete with powder coating, necessary internal electric connection as required and provision and including the following
75(a) ACB 2000 A AC 3 Phase 415 V, 50Hz,microprocessor release 4 polebreaking capactiy 50kA, Manual draw out type - 01 No(b) MCCB630 AAC 3 Phase 415 V, 50Hz,4 pole breaking capactiy 50kA, Manual draw out type - 02 Nos c) MCCB 100 AAC 3 Phase 415 V, 50H z 4 pole breaking capactiy 35kA with adjustable type thermal and magnetic setting relays - 01 Nod) MCCB 320 A AC 3 Phase 415 V, 50H z 4 polebreaking capactiy 35kA with adjustable type thermal and magnetic setting relays - 01 Noe) MCCB 200 A AC 3 Phase 415 V, 50 Hz 4 polebreaking capactiy 25 kA with adjustable type thermal and magnetic setting relays - 01 Nof) ACB 800 A AC 3 Phase 415 V, 50Hz,microprocessor release 4 polebreaking capactiy 50kA, Manual draw out type - 01 No Multifunctional Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs of each breakers.g) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases for each breakers.
76Supply, fix ,connecting , testing and commissioning of OEM Manufactured APFC Panel (automatic and manual operation) with 7% Aluminium reactor of capacity 40 KVAR (Output) @ 440 V AC interconnection with LT Panel/ Transformer (outdoor/ indoor) with appropriate size of electric power cable 1.1KV . The stage rating shall be (2 X 10) + (2 X 5) + (1 X 7.5) + (1 X 2.5) KVAR. The APFC Panel shall be fully type tested at an independnt Laboratory and shall comply with IEC 61439-1&2 and IEC 61921, IS-16636-2017. The degree of protection of enclosure system of the APFC Panel shall be min IP 54 (Outdoor) in accordance with IEC 60529. The capacitor bank shall be internet of things (IoT) enabled and communicable / integrable with BMS . The APFC Panel shall be Outdoor type confirming to IS 13341:1992 & IS13440:1993 floor mounted design fabricated out of 14 SWG CRCA Sheet treated through chemical with 8 tank process method of degreasing, derusting and phosphating powder coating (60-80 microns), painted in SIEMENS GREY (RAL 7032) shade powder coating paint, weather, dust and vermin proof suitable for humidity upto 95% and having four Nos iron legs made of 50x50x6mm thick, 60cm long angle iron below frame with front door and side/ back opening having locking arrangement prewired with copper conductor PVC insulated wire size 2.5sqmm/ extension strips and connected with suitable size thimbles & lugs. The legs duly embedded in ground (45cm) in PCC 1:3:6 type C1 (using 20mm aggregate). Cable entry from bottom. Transparent Acrylic sheet/Bakelite sheet will be provided for shrouding. Average daily temperature :+35 degree celcius max, Ambient temperature :-5 degree celcius to 40 degree celcius, Maximum altitude 2000m. Approved Make of Panel:-ABB/SCHNEIDER/SIEMENS/L&T/CMKL . The OEM \"s specified cannot authorize any other partners / sub vendors to manufacture APFC Panels on their behalf .
77Supply only rubber hand gloves suitable for 11 KV complete allas specified and as directed.
78Supply only rubber mat 1 metre x 2 metre x 19mm complete allas specified and as directed.
79S & F energy efficient LED security light fitting with tube 50 watts new generatiionenergy saving & environmental friendly long life, made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having top opening separate driver compartment with IP66 protection pre-wired and connecting up with with 1.0 Sqmm copper conductor cable upto connector including 1.5 metre long GI tubing light grade bracket of 32 mm dia bend to shape for fixing on wall/ polewith suitable MS bracket nuts, bolts etc., complete all as specified and directed.
80Loop in loop out box of FRP made with IP 65 protection of thermoplasic of size 205 x 255 x 112mm with metric knockouts for cable entry and exit, Combi climate Cable Glands of IP 66/ IP 67 for cable entry and Grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 kA, C Curve Overload and Short Circuit protection, terminals as PVC connector heavy duty 32Amps,4 wayfor cable with necessary fixing arrangemets and with cable glands, etc., complete all as specified and directed.
81S & F Cable PVC insulated LT 1100 V grade with copper conductor of size 3 core 2.5 Sqmm multi stranded conductor laid in ground fixed to wall roof etc with suitable calamps spacers bolts nuts etc complete all as specified and as directed
82S & F MCB SP 0.5Amps, 240 Volts, 10 KA, \"C\" Curve complete all as specified and as directed.
83Supply and fix time switch250 V, single phase of max 20 Amps rated, with contactor fitting inside steel encloser.
84LT Panel boardmade out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 300 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following
85a) MCCB 200 A AC 3 Phase 415 V, 50 Hz 4 polebreaking capactiy 25 kA with adjustable type thermal and magnetic setting relays - 01 Nos.( DG incoming)b) MCCB 100 A AC 3 Phase 415 V, 50 Hz 4 polebreaking capactiy 25kA with adjustable type thermal and magnetic setting relays - 08 Nosc) MCCB 32 A AC 3 Phase 415 V, 50H z 4 polebreaking capactiy 25 kA with adjustable type thermal and magnetic setting relays - 01 Nod) MCB10 A SPN AC 1 Phase 230 V, 50 Hz 2 polecapactiy 10kA - 02 Nose) MCB 32 ASPN AC 1 Phase 230 V, 50 Hz 2 pole capactiy 10kA - 03 Nosf) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs g) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases
86LT Panel boardmade out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 300 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following
87a) MCCB 200 A AC 3 Phase 415 V, 50 Hz 4 polebreaking capactiy 25 kA with adjustable type thermal and magnetic setting relays - 01 Nos.( DG incoming)b) MCCB 100 A AC 3 Phase 415 V, 50 Hz 4 polebreaking capactiy 25kA with adjustable type thermal and magnetic setting relays - 08 Nosc) MCCB 32 A AC 3 Phase 415 V, 50H z 4 polebreaking capactiy 25 kA with adjustable type thermal and magnetic setting relays - 01 Nod) MCB10 A SPN AC 1 Phase 230 V, 50 Hz 2 polecapactiy 10kA - 02 Nose) MCB 32 ASPN AC 1 Phase 230 V, 50 Hz 2 pole capactiy 10kA - 03 Nosf) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs g) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases
88LT Panel boardmade out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 300 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following
89a) MCCB 200 A AC 3 Phase 415 V, 50 Hz 4 polebreaking capactiy 25 kA with adjustable type thermal and magnetic setting relays - 01 Nos.( DG incoming)b) MCCB 100 A AC 3 Phase 415 V, 50 Hz 4 polebreaking capactiy 25kA with adjustable type thermal and magnetic setting relays - 08 Nosc) MCCB 32 A AC 3 Phase 415 V, 50H z 4 polebreaking capactiy 25 kA with adjustable type thermal and magnetic setting relays - 01 Nod) MCB10 A SPN AC 1 Phase 230 V, 50 Hz 2 polecapactiy 10kA - 02 Nose) MCB 32 ASPN AC 1 Phase 230 V, 50 Hz 2 pole capactiy 10kA - 03 Nosf) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs g) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases
90Fire fighting and fire alarm system
91LT Panel boardmade out of CRCA sheet 3.15 mm thick outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, cable connector for connecting multi cables located in cable chamber terminated form the switchergear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 tinned copper bus bar with insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 300 A capacity complete with powder coating, necessary internal electric connection as required and provision of the following
92a) MCCB 200 A AC 3 Phase 415 V, 50 Hz 4 polebreaking capactiy 25 kA with adjustable type thermal and magnetic setting relays - 01 Nos.( DG incoming)b) MCCB 100 A AC 3 Phase 415 V, 50 Hz 4 polebreaking capactiy 25kA with adjustable type thermal and magnetic setting relays - 08 Nosc) MCCB 32 A AC 3 Phase 415 V, 50H z 4 polebreaking capactiy 25 kA with adjustable type thermal and magnetic setting relays - 01 Nod) MCB10 A SPN AC 1 Phase 230 V, 50 Hz 2 polecapactiy 10kA - 02 Nose) MCB 32 ASPN AC 1 Phase 230 V, 50 Hz 2 pole capactiy 10kA - 03 Nosf) Intelligent Panel meter to measure voltage, current, frequency, power factor, kWH, etc with all connected CTs g) LED Indicating Lamps for each phase with colour coed Red Yellow Blue for R, Y and B Phases
93Supply and fix CI ball type foot valve of size 80 mm Complete all as specified and as directed.
94Supply and fix CI ball type foot valve of size 100 mm Complete all as specified and as directed.
95S & F Cable PVC insulated LT 1100 V grade with copper conductor of size 2 core 1.5 Sqmm multi stranded conductor laid in ground fixed to wall roof etc with suitable calamps spacers bolts nuts etc complete all as specified and as directed
96Supply and fix 12 Volts, 7 Amps Battery Complete all as specified and as directed.
97S&F fire buckets 3 Nos with stand complete all as specified and directed.
98AVIATION OBSTRUCTION LIGHT
99S & F Integral LED Aviation obstruction Light, PF>0.90, comprising of aluminium housing with polycarbonate enclosure, 30 watts single headed including standard fixing arrangements and connecting up complete all as specified and as directed. Make: BGAV 302 LED of BAJAJ or its equivalent as approved by GE.
100Arboriculture
101Supply & Planting american/ Korean carpet grass by piece turfing including preparion of ground complete all as specified and as directed
102Supply only appoved loose soil/sweet earth best quality for plant complete all as specified and as directed
103Supply of approved manure (cow dung) complete all as specified and as directed
104Supply & Planting Aakalita/ Duranta varigatedPlant including preparation complete all as specified and as directed
105Supply & plantinggolder tum/ mananta tree plant including preparation complete all as specified and as directed
106LIFTS
107Supply, install testing & commissioning of electrically operated passenger lift of capacity 13 Passenger (884 Kgs capacity) in the adjusting lift well, 1.5 mtr/Sec speed with automatic micro stroke button control, micro processor based controller simplex selective/collective control suitable for 3 phase, 50 Hz 415 Volt AC supply independent operating with AC variable frequency (AC VVVF) control or closed loop with power saving regenerative drive) with suitable motor gear unit ground floor plu seighth upper floor i.e with 11 stops and 11 landing (G+10) with or without attendent suitable for synchronised operation automatic power operated centre opening (opening as per site requirement)sliding stainless steel door with mirror finish or 16 gauges with infra red sensors all along the height for car doors with automatic rescue/leveling device (ARD) (with +-5 mm) with suitable batteries, haul position digital indicators in car and all landing with call indicating lights etc including necessary housts and beams for mounting machine in the machine room including all civil works required in connection with erection of lifts complete all as specified. The lift shall be provided with and including the following :-
108a) Fire man switch.(b) Automatic rescue device (ARD) during power failure including manual operation provision with suitable capacity or batteries designed for running the lift with full load.© Battery operated emergency light (LED Ceiling fitting) alarm ( speaker for emergency alarm system to be fixed) and stop button in car with rechargeable areangement for battery).(d) Suitable decorative ligting arrangement inside the lift(e) One sleek circular PVC heavy duty fan in false ceiling.(f) Aluminium chequred plate (3 mm thick) as flooring joint in chequred plate should not more than one and top covering with PVC flooring complete.(g) Non stop button/independent operation.(h) Over load warning indicator both audio and visual type with tripping system having relay etc.(j) Front landing door of stainless steel moon rock finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds.
109(k) Car size shall be conform to IS -3531-1976 and body to be stainless steel of 16 gauges moon rock finish with stainless steel hand rail 38 mm hairline finish.(l) Set of three in number limit switches at the bottom and top most position of lift hoist ways as specified in IS.(m) Mirror of 4 mm thickenss of suitable size as specified.(n) Opening with glass door of 5 mm thick 200 x 600 mm size in all the doors.(o) Specification plate with complete details.(p) Continuous earthing for machine and equipments.(q) Steel wire rope of adequate size as per relevent IS and as per manufacturer specifications.(r) Other standard fixtures and fittings like guide rail, sheaves counter weights with guards, buffer gear unit brakes, control panel, lock, governor, car operational panel, control and trailing cables complete.(s) Full length display indicator panel.(u) Suitable phase reversal relay shall be provided on the controller to protect lift /equipment against phase reverse, phase failure and low voltage.
110(v) Stainless steel front opened landing door with small opening for vision of size 200mm x 800 mm with toughended glass not less than 08 mm thick.(w) Intercom be connected with nearest sucurity post. Note:a) Cost oflift inspector inspection is deemed to be inclded in the item rate. provision of one lamp holder, one socket with PVC box of sitable size to be provided at the top of lift for servicing.b) one lift of 13 passengers only has to be provide with all necessary facilities require for fire lift as per NBC -2016.
111All as per item no 91 above but for capacity 08 Passenger (544 Kgs).
112DG Set
113Supply, install, testing and commissioningof silent Diesel Engine Generating set including accoustic enclosure as per latest CPCB norms 415 Volts 58.5KVA, 3 Phase, 0.8 power factor, 50 Hz, 1500 RPM self excited self regulated brushless AC generator including accoustic enclosure suitable for ambient condition and conforming to condition under IS-4722, BS-5514/2613/5000 with AMF Panel and including the followingincluding accoustic enclosure suitable for ambient condition at sea area and conforming to Engine as per IS:10002, ISO-3046, BS-5514 and Alternator as per IS:4774, BS EN 60034-1 with the following accessories including necessary suitable size PCC foundation, GI pipe for laying of cables etc., all as per manufacturers instructions complete all as specified and directedMake: Kirloskar/ Cummins/Ashok Leyland/ Jyoti/ Crompton
114(i) The capacity of generator set shall be net after all due de-rating factors as per relevant ISI design.(ii) Rate quoted shall be deemed to be inclusive of cable and terminations form generator to the AMF panel, with necessary holes to wall including making good to disturbed surfaces so as to match with the existing finishes all as specified and directed.(iii) The quoted rate shall be deemed to be inclusive of first fill of oil and final successful acceptance test.(A) Alternator: Standard design alternator rated at 58.5KVA net output at site after considering de-rating as per site conditions at 0.8 (Lag) power factor AC, 3 Phase, 4 wire, 415 Volts, 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class \"H\" and voltage regulation of +/-1% at rated voltage from no load to full load.The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in +/-1% tolerance.The alternator will be suitable for tropical climate and shall generally conform to BS-2613/5000/IS-4722.
115(i) Insulation class-\"H‘(ii) Temperature rise Class-\"H‘(iii) Excitation: Self Excited(iv) Regulation Performance: The voltage is kept constant with +/-1%, manual voltage adjustment within +/-5%(v) Frequency regulation +/-1%(B) Diesel Engine: Adequate capacity of Diesel engine as approved by the Accepting Officer based on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS-5514 with an overload capacity of 10% for one hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:
116(i) Fly wheel with housing(ii) Cooling System: Moulded radiator with fan & belts(iii) Cooling Water Pump: Centrifugal type belt driven(iv) Exhaust System: Exhaust System complete with exhaust piping of 150mm dia. with MS pipe light grade up to & outside and 1 meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure.Exhaust gas turbo charger type.Exhaust manifoldSilencer: Residual type Bellows(v) Fuel System: Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed/ frequency regulation, Fuel filters, Fuel hoses.(vi) Lub oil System: Lubricating oil filter, Lubricating oil pump(vii) Air Intake System: Air intake Manifold, Air cleaner dry type(viii) Governor: Electronic Governor(ix) Starting System: Electric Self starter with maintenance free battery including battery charging alternator
117(x) Batteries: Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and starter gear ring start and stop push button, Ignition key/switch.Handling and Operation: Salient features of accessories shall be as under:Radiator with blower fanCorrosion inhibitor coolantPaper element filters for fuel, lub oil and by passElectronic governor controlled direct fuel injection systemFly wheel housing and fly wheel(xi) Generator Monitoring Panel: Comprising of all standard items as mentioned under this schedule or as per standard practice ignition key switch and start/stop arrangement, indications for engine parameters, hour run meter, RPM meter, engine oil pressure indicator, water/coolant temperature indicator, battery volt display.(xii) Safety Controls: Engine low lube oil pressure high water temperature and over speeding of engine
118(xiii) Coupling arrangement : Flexible coupling, fly wheel to suit flexible coupling(xiv) Accessories : AVM pads built or separtely mounted to manufacturer base frames.(xv) Base frame: Made out of ISMC 250 of sturdy design made of MS channel or as recommended by manufacturer.(C) AMF panel: Factory made indoor type control cubical made out of 2 mm thick CRCA sheet dust and vermin proof totally enclosed with front and rear opening of 415 Volts, 3 phase, 4 wire, AC, 50 Hz, including powder coated, aluminum bus bar of one and half times the rated load of 58.5 KVA alternator complete with internal wiring with PVC insulated single core copper conductor multi stranded wire of 1100 Volts grade of suitable capacity,fuses name plates consisting of 4 pole MCCB\"s and contactors and relays of capacity as recommended by the manufacturer, detachable cable gland plates all controls, indicators andMicro processor base LED/LCD display for indication voltage, current, frequency, speed, KW, KWH, PF, temperature,battery voltage,etc with the following:-
119(i) indicator lamps - 3 Nos, (ii) Fuse set - 3 Nos (iii) Annuciation with indication lamps for :- (a) Low lub oil pressure (b) High water Temparature(c) Engine over speed (iv) Battery low voltage Controls :- (a) Load on Indication(b) Load off indication(c) Engine start push button (d) Engine stop push button(v) Fault accept/Reset push button(vi) Battary Charger : (a) Transformer (b) Rectifier (c) Resistance (d) DC Volt meter(e) Charger rate selector switch(D) Accoustic Enclosure : Manufactured by OEM suitable for 58.5 KVA DG Set(i) NAL approved as per CPCB(ii) It should be as per latest rules and regulations of Ministry of Environment and Forest and pollution control board
120(iv) Fuel tank should be inside the enclosure and the capacity of the tank for 12 Hrs run the DG Set.(v) construction details/specification are as follows:(vi) Outer Body : CRCA sheet of 1.6 mm thick(vii) Doors CRCA sheet of 1.6 mm thick(viii) Sound insulation : As per OEM Norms.(ix) The accoustic should be composite in construction and fully assembled integral unit(x) The batteries should be placed inside the enclosure beside the DG set on a suitable insulated plat form(xi) The cost of the fuel pipe lines is deemed to be included in the quoted rate.(xii) The DG Set should be provided with externalEmergency stop push button(xiii) The enclosure should be suitably illluminatedby CFL/FTL/LED lamp fittings(xiv) The noise level should be 75 dB at 1m under freefield conditions
121(xv) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set green.The base frame should be painted with epoxy based black shade(xvi) Rubber matting of LV grade 19 mm thick of suitable size, chequered type, ISI marked shall be laid in front of control panel.(E) Testing: The DG set shall be tested for a period Not less than 12 hours continuously out of which at least 1/2Hr on No Load and 02 hrs on 25% load, 02 hours each on 50% and 2.5 hrs on 75 % of rated full load, 4 hours on rated full load and 01 hours on 10% in exceess of rated full load.Necessary load shall be given on connected load. If the required full load for testing purpose is not available at the site, artificial load has to be arranged by the contractor for the testing. All instruments, consumable stores like engine oil, grease required for carrying out the tests including manpower shall be provided by the contractor. Contractor shall arrange DHPP for testing of DG set . Unit rate quoted shall deemed to include cost of the same.
122M & L Earthing complete with copper earth plate electrode 600 mm x 600mm x 3.15 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with copper earth strip of size 20x3mm by means of bolts, nuts,check nuts and washers protected by 40 mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C1, with 40 mm thick Precast R.C.C. (1:2:4) type B1 cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar, including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessarytesting on completion including taking down old one complete all as specified and as directed.
123PHASE -IIIOUTSOURCING OF 8 AND 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 91 AND 92DURING FIRST YEAR OF DEFECT LIABILTY PERIOD.
124Outsourcing of services for operaion of 01 x 13 Passenger and 01 x 08 Passenger lifts to serve G+10 floors, during First Year of the Defect Liability Period by providing services of One Lift Operators (Semi Skilled) per Shift in 02 shifts on all the days including taking care of from any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfication of users/department including attending telephonic complaints, maintaining necessary records and documents etc. complete all as specified and as directed
125PHASE -IV OUTSOURCING OF 8 AND 13 PASSENGERS LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 91 AND 92DURING SECOND YEAR OF DEFECT LIABILTY PERIOD.
126Outsourcing of services for operaion of 01 x 13 Passenger and 01 x 08 Passenger lifts to serve G+10 floors, during Second Year of the Defect Liability Period by providing services of One Lift Operators (Semi Skilled) per Shift in 02 shifts on all the days including taking care of from any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfication of users/department including attending telephonic complaints, maintaining necessary records and documents etc. complete all as specified and as directed
127PHASE -VOUTSOURCING OF 8 AND 13 PASSENGERS LIFTSAND COMPREHENSIVE MAINTENANCE OF LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 91 AND 92DURING FIRST YEAR AFTER EXPIRY OF DEFECT LIABILTY PERIOD.
128Outsourcing of services for operaion of 01 x 13 Passenger and 01 x 08 Passenger lifts to serve G+10 floors, during first Year after expiry of Defect Liability Period by providing services of One Lift Operators (Semi Skilled) per Shift in 02 shifts on all the days including taking care of from any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfication of users/department including attending telephonic complaints, maintaining necessary records and documents etc. complete all as specified and as directed
129Comprehensive maintenance of Electrically Operated 13 passenger lifts (884 Kgs)to serve G+10 upper floors all as mentioned vide SI No. 91 of Sch \"A\" Phase-I during 1st year after expiry of defects liability period all as specified and directed
130Comprehensive maintenance of Electrically Operated 8 passenger lifts (544 Kgs)to serve G+10 upper floors all as mentioned vide SI No. 92 of Sch \"A\" Phase-I during 1st year after expiry of defects liability period all as specified and directed
131PHASE -VIOUTSOURCING OF 8 AND 13 PASSENGERS LIFTSAND COMPREHENSIVE MAINTENANCE OF LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 91 AND 92DURING SECOND YEAR AFTER EXPIRY OF DEFECT LIABILTY PERIOD.
132Outsourcing of services for operaion of 01 x 13 Passenger and 01 x 08 Passenger lifts to serve G+10 floors, during second Year after expiry of Defect Liability Period by providing services of One Lift Operators (Semi Skilled) per Shift in 02 shifts on all the days including taking care of from any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfication of users/department including attending telephonic complaints, maintaining necessary records and documents etc. complete all as specified and as directed
133Comprehensive maintenance of Electrically Operated 13 passenger lifts (884 Kgs)to serve G+10 upper floors all as mentioned vide SI No. 91 of Sch \"A\" Phase-I during 2nd year after expiry of defects liability period all as specified and directed
134Comprehensive maintenance of Electrically Operated 8 passenger lifts (544 Kgs)to serve G+10 upper floors all as mentioned vide SI No. 92 of Sch \"A\" Phase-I during 2nd year after expiry of defects liability period all as specified and directed
135PHASE -VIIOUTSOURCING OF 8 AND 13 PASSENGERS LIFTSAND COMPREHENSIVE MAINTENANCE OF LIFTS AS PROVIDED UNDER THIS CONTRACT AS PER SERIAL ITEM No. 91 AND 92DURING THIRD YEAR AFTER EXPIRY OF DEFECT LIABILTY PERIOD.
136Outsourcing of services for operaion of 01 x 13 Passenger and 01 x 08 Passenger lifts to serve G+10 floors, during third Year after expiry of Defect Liability Period by providing services of One Lift Operators (Semi Skilled) per Shift in 02 shifts on all the days including taking care of from any pilferage, theft or damage etc. to ensure smooth and trouble free operation of lifts to the entire satisfication of users/department including attending telephonic complaints, maintaining necessary records and documents etc. complete all as specified and as directed
137Comprehensive maintenance of Electrically Operated 13 passenger lifts (884 Kgs)to serve G+10 upper floors all as mentioned vide SI No. 91 of Sch \"A\" Phase-I during 3rd year after expiry of defects liability period all as specified and directed
138Comprehensive maintenance of Electrically Operated 8 passenger lifts (544 Kgs)to serve G+10 upper floors all as mentioned vide SI No. 92 of Sch \"A\" Phase-I during 3rd year after expiry of defects liability period all as specified and directed
139Notes for Outsourcing Services Items:(i) The lift shall be operated daily in two shifts as directed by the Engineer-in-Charge.(ii) The timings for two shifts of 8 hours each daily i.e. First shift shall be from 0600 hours to 1400 Hours and Second Shift shall be from 1400 Hours to 2200 Hours.(iii) In case of non-function of passenger lift, the Goods Lift installed in the same building shall be operated as directed.(iv) The work shall be supervised by adequately qualified supervisor with relevant experience of minimum 5 years items under BoQ shall be deemed to be including the same.(v) The unit rate is deemed to include for maintaining log books, record of repair/replacement of perished/unserviceable, minor adjustments, minor repairs of all accessories, cleaning/up keeping of lift and surrounding area as directed by the Engineer-in-Charge.(vi) One emergency light and necessary tools shall be available in a tool box with the operator in the shift for smooth functioning of lifts.(vii) Conveyance and communication system like mobile phone etc. shall be provided by the Bidders/Service providers to all Lift Attendants/Supervisors.(viii) The Bidders shall ensure house keeping, environmental cleanliness of area all round the lift and the area shall be kept absolutely neat and clean. The lift attendant shall clean the Lift car cabin, all landing floors and tiles all round lift doors with necessary cleaning material such as cotton cloth and cleaning solution etc.
140(ix) The Bidders shall abide by the latest Labour rules and minimum wages Act. Wages paid by the bidders to the persons employed shall not be less than the minimum wages fixed by the state/central government from time to time whichever is higher. The Bidders shall also insure the workmen employed on the job.(x) The Bidders is responsible for insurance, EPF, ESI, Bonus, Labour welfare cess et., as applicable and shall be paid to the workmen as per existing Labour rules/ Acts/ regulations and rate quoted shall be deemed to be included for the same.(xi) Dress Code: The bidders shall provide the workmen with Dark Blue Colour uniform {formal pant & T-shirt} with labels showing/ printed i.e. “Name of the firm and designation” on front and on the back of the T-shirt along with protective clothing/gear. The bidders shall also provide shoes to the workers and the persons shall not be allowed to enter the work site without wearing shoes.(xii) INSURANCE: The Bidders shall be responsible for all Accidents/ Injuries happening to the workmen. Any accident causing minor/ fatal injury, partial disability due to any untoward incident or non-adherence to safety and IE regulations or fault in maintaining of internal electric supply system or on account of any mishandling/ wrong operation/ lack of knowledge of safety precautions or on
141account of any circumstances beyond his/ their control, the bidders shall be solely responsible for settling all claims of compensation to the deceased, falling which department will have a right to recover any sum indicated/ claimed by Labour commissioner/court authorities. No claim whatsoever will be entertained in this regard. No compensation is payable by the department on this account. Bidders shall provide first aid boxes to meet any emergency situations.(xiii) The rate quoted by the bidders shall be deemed to be including Basic rate (Minimum Wages as notified by Government of India/ State Government/ Local body, whichever is higher), employers contribution towards Employees Provident Fund (EPF) liability, contribution towards Employees State Insurance Corporation (ESIC), contribution towards Bonus. Overhead and profit and labour welfare cess (LWC) as applicable depending upon the manpower requirement. This will create onus on the Bidders to applicable depending upon the man power requirement. This will create onus on the bidders to ascertain the relevant rates and quote accordingly. The rates quoted shall be inclusive of all taxes, cess, levies are applicable including GST. Note: The Manpower deployed shall be changed for every 11 months period. The rate quoted deemed to be inclusive for the same.
142Notes for Comprehensive Maintenance Items:(i) Comprehensive maintenance consists of preventive and breakdown services including replacement of material and labour for major/minor spare parts and consumables like topping of Oils /grease/door rollers/ relays/ door belts/ gate lock contacts and hardware like bolts and nuts including load testing of lift for satisfactory performance once in a year complete and rate quoted by the tenderer includes for the above Lifts.(ii) Preventive maintenance consists of carrying out routine check by skilled personnel as specified in Particular specifications and as directed by Engineer-in-Charge and lubricating to all moving parts, topping parts, topping up of oils as per Lubrication Chart including Material and labour for all consumable and major/minor spare parts.(iii)Breakdown maintenance consists of attending to the faults that may occur and carrying out necessary repairs to electrical, control circuits and mechanical components including materials & labour for all minor & major spare parts and consumables of the lift that may occur during the operation.(iv) Fortnightly, quarterly maintenance registers shall be maintained and signed by the site engineer and contractor.
143(v) Load testing shall be arranged by the contractor to the Lift for which repairs were carried out as and when directed by Engineer-in-Charge. (Once in a year with a validity of one Year/ Twice in a year with a validity of 06 Months)(vi) All maintenance works shall be carried out by well qualified tradesmen and supervisor of OEM.(vii) The quoted rate shall be deemed to be included the above aspect and for consumables such as timely toping up oils, acrylic covers, fuses, grease, waste cotton, stationery and other miscellaneous items and all minor & major spare parts.(viii) The tenderer shall submit MoU from the original manufacturer of the lift for comprehensive maintenance to undertake comprehensive maintenance during and after Defects Liability Period directly or through their nearest authorized/accredited agencies service personnel.The MoU shall be submitted at least 06 months prior to issue of completion certificate of main contract as per Work Order No I.
144PHASE -VIIIMAINTENANCE OF ARBORICULTURE.
145Maintenance of all plants supplied in arboriculture complete all as specified and as directed

Other Detail

Information Source https://defproc.gov.in/nicgep/app
Download FileName File Description File Size
Download 6049779a-6204-44d7-a279-70b9c686d880.html Tender Documents 0 KB
Download 88754TENDER_merged.pdf Tender Documents 0 KB
Download BOQ_839830.xls Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.