Indian Tenders

Tender Notice

TDR 52977487
Tendering Authority Military Engineer Services
Tender No CEBZ/NSD/TOKEN/23 OF 2025-26
Tender ID 2025_MES_744826_1
Tender Brief Corrigendum : Tender For Provision Of Otm Accommodation And Allied Infra For Klp At Nasirabad
City nasirabad
State Rajasthan
Document Fees INR 3000 /-
EMD INR 1260500.0 /-
Tender Value INR 18.69 Crore /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender For Provision Of Otm Accommodation And Allied Infra For Klp At Nasirabad

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 24-03-2026 Corrigendum 11 Date 04-04-2026
2 20-03-2026 Corrigendum 10 BOQ 04-04-2026
3 17-03-2026 Corrigendum 9 Date 31-03-2026
4 17-03-2026 Corrigendum 9 Date 31-03-2026
5 09-03-2026 Corrigendum 8 Date 24-03-2026
6 09-03-2026 Corrigendum 8 Date 24-03-2026
7 09-03-2026 Corrigendum 8 Date 24-03-2026
8 02-03-2026 Corrigendum 7 Date 16-03-2026
9 02-03-2026 Corrigendum 7 Date 16-03-2026
10 02-03-2026 Corrigendum 7 Date 16-03-2026
11 02-03-2026 Corrigendum 7 Date 16-03-2026
12 20-02-2026 Corrigendum 6 Date 09-03-2026
13 20-02-2026 Corrigendum 6 Date 09-03-2026
14 20-02-2026 Corrigendum 6 Date 09-03-2026
15 20-02-2026 Corrigendum 6 Date 09-03-2026
16 13-02-2026 Corrigendum 5 Date 28-02-2026
17 13-02-2026 Corrigendum 5 Date 28-02-2026
18 13-02-2026 Corrigendum 5 Date 28-02-2026
19 13-02-2026 Corrigendum 5 Date 28-02-2026
20 06-02-2026 Corrigendum 4 Date 21-02-2026
21 06-02-2026 Corrigendum 4 Date 21-02-2026
22 06-02-2026 Corrigendum 4 Date 21-02-2026
23 06-02-2026 Corrigendum 4 Date 21-02-2026
24 30-01-2026 Corrigendum 3 Date 14-02-2026
25 30-01-2026 Corrigendum 3 Date 14-02-2026
26 30-01-2026 Corrigendum 3 Date 14-02-2026
27 30-01-2026 Corrigendum 3 Date 14-02-2026
28 20-01-2026 Corrigendum 2 Date 07-02-2026
29 20-01-2026 Corrigendum 2 Date 07-02-2026
30 20-01-2026 Corrigendum 2 Date 07-02-2026
31 20-01-2026 Corrigendum 2 Date 07-02-2026
32 08-01-2026 Corrigendum 1 Date 28-01-2026
33 08-01-2026 Corrigendum 1 Date 28-01-2026
34 08-01-2026 Corrigendum 1 Date 28-01-2026
35 08-01-2026 Corrigendum 1 Date 28-01-2026

Key Dates

Publish Date 20-03-2026
Last Date of Bid Submission 04-04-2026

Contact Information

Company Name Military Engineer Services
Contact Person Chief Engineer Bhopal Zone
Address HQ, Chief Engineer, Bhopal Zone, Military Engineer Services, Bhopal-462001

BOQ Items

Name of Work: PROVN OF OTM ACCN AND ALLIED INFRA FOR KLP AT NASIRABAD
Sl. No. Item Description
1Note:-Please refer schedule \"A\" notesbefore quoting the tender.
2GENERAL SUMMARY
3Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule ‘A’Part- I (Ref prepriced schedule attached seperately)
4Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’Part- II (Ref prepriced schedule attached seperately)
5Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule ‘A’Part- III (Ref prepriced schedule attached seperately)
6Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule ‘A’Part- IV (Ref prepriced schedule attached seperately)
7Lump sum price worked out by the contractor for EXTERNAL ELETRIC SUPPLY WORKS as listed in Schedule ‘A’Part- V (Ref prepriced schedule attached seperately)
8Lump sum price worked out by the contractor for ROAD, PATH AND CULVERT WORKS as listed in Schedule ‘A’Part- VI (Ref prepriced schedule attached seperately)
9Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule ‘A’Part- VII(Ref prepriced schedule attached seperately)
10Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule ‘A’Part-VIII(Ref prepriced schedule attached seperately)
11Lump sum price worked out by the contractor for (COMPOUND WALL FENCING AND GATE WORKS) as listed in Schedule ‘A’Part-IX (Ref prepriced schedule attached seperately)
12Lump sum price worked out by the contractor for LIGHTENING PROTECTION WORKSas listed in Schedule ‘A’ Part-X (Ref prepriced schedule attached seperately)
13Lump sum price worked out by the contractor for RAIN WATER HARVESTING WORKSas listed in Schedule ‘A’ Part-XI (Ref prepriced schedule attached seperately)
14Lump sum price worked out by the contractor for ARBORICULTURE WORKSas listed in Schedule ‘A’ Part-XII (Ref prepriced schedule attached seperately)
15Lump sum price worked out by the contractor for EXCAVATION, EARTH WORK AND SITE DEVELOPMENT WORKSas listed in Schedule ‘A’ Part-XIII (Ref prepriced schedule attached seperately)
16SCH \"A\" Pt - XIV (MISCELLANEOUS ITEMS)
17INTERNAL ELECTRIFICATION WORKS NOTE:- For items of INTERNAL ELECTRIFICATION notes given at the beginning of Sch ‘A’ Part-III ( INTERNAL ELECTRIFICATION) shall also be applicable.
18M&L point wiring for lightpoint wiring complete with 1.5 Sq.mmm PVC insulation unsheathed muilt-starnded FRLSH copper conductor 1100 Volts grade draw through in and including 20 mm dia PVC conduit and conduit accessories, concealed in walls and terminated to and including provision of modular metal flush boxes (metal switch board of any type and size) with modular metal frame plate and white cover for housing switch, sockets, regulators etc, including 1.5 sqmm PVC insulated unsheathed multi-stranded FRLSH copper conducotor cable as earth continuity conductor and connecting to common earth dolly, complete all as specified and directed for the following points (Ser Item No 4.02 to 4.06) .NOTE;-The quoted rate is deemed to inclusive of cost of metal flush boxes, modular white cover plate.
19One light point/ fan point/ exhaust fan point controlled by one way 6A modularswitch with ISI Marked
20One light point controlled by two way6A modular switch with ISI Marked
21One socket outlet 3pin independent controlled by one way6A modular switch with ISI Marked
22One socket outlet 3pin on same board controlled by one way 6A modular switch with ISI Marked
23All as per Sl item No. 4.01 above, but with cable 2.5 sqmm for phase and neutral & 2.5 sqmm for earth continuity complete for 6/16 Amps socket point on independent board with ISI Marked complete all as specified and directed
24S&F LED tube light fitting batten type, 20 W, 230v , efficacy not less than120 Lumens per watt, colour temprature 6500 K (Cool White), power factor greater than 0.90, polycarbonate body , CRI 80, IP rating IP 20,THDv within 5% and THDi (8-10%)and integrated electronic drivercomplete with all accessories internally pre-wired and including connecting up with flexible copper conductor cable of suitable size from ceiling rose all with ISI Marked as specified and directed.Notes :- 1.The rate of flexible copper conductor cable of suitable sizefor connectionis included in this item and nothing shall be paid extra on this account. 2. Warranty for replacement of each LEDLight fitting shall not be less than 05 yearsfrom the date of purchase. 3. Date of Purchase shall be marked on each fixture with permanent marker for redeeming warrenty benefits.
25S&F LED lamp 12W, 230V AC, 50 Hz single phase including bakelite button with all fitting fixing accessories with ISI Marked complete all as specified and directed.
26S & F surface mounted LED downlighter 15 watt with white powder coated aluminium housing with integrated electronic driver with output short circuit protection, surge protection IP-20, CRI>80, PF>0.90 complete all as specified and directed.
27S & F surface mounted LED downlighter 18 watt with white powder coated aluminium housing with integrated electronic driver with output short circuit protection, surge protection IP-20, CRI>80, PF>0.90 complete all as specified and directed.
28S & F RJ telephonic socket with shutter, 1 module including cover plate, metal flush box (16 Guage) concealed in wall/roof complete all as specified and directed.
29EXTERNAL WATER SUPPLY WORKSNOTE:- For items of EXTERNAL WATER SUPPLY WORKS notes given at the beginning of Sch ‘A’ Part-IV (EXTERNAL WATER SUPPLY WORKS) shall also be applicable.
30Supplying, laying, connecting, jointing and testing in trenches 150 mm nominal dia ductile iron pressure pipe for water mains, centrifugally cast, spigot and socket ends (for push on joints), class K9 in any length with external protection of Metallic zinc with finishing layer of bituminous paint and internal linings of Portland cement (with or without additives) mortar with seal coat, all as per IS 8329: 2000 and including materials and jointing with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 complete all as specified and as directed. Note : DI fitting shall be measured and paid separtely
31M&L for cutting of existing road/hard standing for crossing of MS/DI/CI/GI Pipes for laying of pipe upto 300 mm dia borePipes including necessary excavation and earth work including repairing the same as per existing road/hard standing by providing PCC (1:2:4)type B1 to match with existing surface complete all as specified and as directed.
32M&L for drilling and tapping in CI water main of any size in position for branch connectionof 150/200 mm bore of pipe complete with clamp, nut bolt, washer etc complete all as specified and directed.
33M & L for plugging leaking lead joints of existing CI pipe line including by using extra reqd pig lead / lead wool to rectify the leakage and necessary caulking and earth work for 150mm to 450mm bore pipes complete all as specified and directed
34Supplying, laying, connecting, jointing and testing in trenches ductile iron fittings (special castings) (class K12 as per IS 9523: 2000) for ductile iron pressure pipe for water mains upto 300 mm nominal dia (spigot and socket and flange ends (for push on joints and flanged joints) with external coatings of Metallic zinc with finishing layer of bituminous paint and internal linings of Portland cement (with or without additives) mortar with seal coat, all as per IS 9523: 2000 and including materials and jointing with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 for push on joints and rubber gasket as per IS 638: 1979 for flanged joints complete all as specified and as directed.
35M & L for construction of new valve pit/chamber of size 1050 mm (Length) X 750 mm (Breadth) X 1000 mm (depth) including necessary earth work in any type of soil, PCC foundation M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate as in base concrete, brick work with sub class \"B\" bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, cement plaster 20 mm thick internally in two coats of (15 mm and 5 mm) in cement mortar 1:4, 3 mm thick mild steel sheet of any grade and designation as per IS 513: 2008 and IS 10748: 2004 welded with angle iron (40 mm X 40 mm X 6 mm) frame of structural steel, frame welded with angle iron (50 mm X 50 mm X 6 mm) frame of structural steel, welded to flat iron of size 150 mm X 50 mm X 6 mm of structural steel, fixed with bolt of 16 mm dia anchored with plate of size 100 mm X 100 mm X 3 mm of structural steel, bolt and anchored plate embedded in 250 mm thick PCC coping in M15(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, mild steel handle, grade E165 as per IS 15911: 2010 for structural steel with necessary, welding, riveting, bolting including painting exposed steel surfaces with two coats of bituminous paint and embedded surfaces of steel with two coats of tar, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash.
36EXTERNAL ELECTRIC SUPPLY WORKS NOTE:- For items of EXTERNAL ELECTRIC SUPPLY WORKS notes given at the beginning of Sch ‘A’ Part-V (EXTERNAL ELECTRIC SUPPLY WORKS) shall also be applicable.
37Supply, installation, testing and commissioning of LT Panel Made out of CRCA sheet 3.15mm thick sheet steel, outdoor type, factory made by CPRI approved manufacturer, totally enclosed, dust and vermin proof (protection Class IP 54), (front opening) with locking arrangement, double door duly compartmentalized with extended canopy at the top, the panel shall duly powder coated with colour shade RAL 7035 Siemens grey Pure Polyester adopting 8 tank pretreatment of fabricated job before powder coating, the panel shall consist of the following switchgear:-Incomer- MCCB TPN 250 A, 35kA, adjustable thermal and megnatic relese-1No, Out going- MCCB TPN 160A 25kA-1No, Out going- MCCB TPN 100A 16kA-1No, MCCB 3P 63A 16kA -1 Nos, MCB 3P 32A 10kA -2 Nos, MCB SPN 32A 10kA -2 Nos main aluminum bus bar shall be of 400A TPN, all inter connections to outgoing feeders shall be made with TPN aluminum bus bar of rating not less than the current carrying capacity of the respective feeder, all bus bars shall be covered with colour coded heat shrinkable sleeve, the complete panel shall be mounted on ISMC of 75x40mm duly painted with black paint. Digital Ammeter (0-400) with ASS-1No, Current transformer of suitable rating-3No, Digital Voltmeter with VSS(0-500)V-1No, RYB LED set-1, including suitable size of cable lugs and PCC foundation complete all as specified and directed. (MAIN LT PANEL)
38Supply, installation, testing and commissioning of LT Panel Made out of CRCA sheet 3.15mm thick sheet steel, outdoor type, factory made by CPRI approved manufacturer, totally enclosed, dust and vermin proof (protection Class IP 54), (front opening) with locking arrangement, double door duly compartmentalized with extended canopy at the top, the panel shall duly powder coated with colour shade RAL 7035 Siemens grey Pure Polyester adopting 8 tank pretreatment of fabricated job before powder coating, the panel shall consist of the following switchgear:-Incomer- MCCB TPN 100 A 25kA, adjustable thermal and megnatic relese-1 No, Out going- MCCB TPN 63A 16kA-1 No, MCCB SPN 32A 16kA -1 No, main aluminum bus bar shall be of 150 A TPN, all inter connections to outgoing feeders shall be made with TPN aluminum bus bar of rating not less than the current carrying capacity of the respective feeder, all bus bars shall be covered with colour coded heat shrinkable sleeve, the complete panel shall be mounted on ISMC of 75x40mm duly painted with black paint. Digital Ammeter (0-400) with ASS-1No, Current transformer of suitable rating-3No, Digital Voltmeter with VSS(0-500)V-1No, RYB LED set-1, including suitable size of cable lugs and PCC foundation complete all as specified and directed. (FP-1 )
39Supply, installation, testing and commissioning of LT Panel Made out of CRCA sheet 3.15mm thick sheet steel, outdoor type, factory made by CPRI approved manufacturer, totally enclosed, dust and vermin proof (protection Class IP 54), (front opening) with locking arrangement, double door duly compartmentalized with extended canopy at the top, the panel shall duly powder coated with colour shade RAL 7035 Siemens grey Pure Polyester adopting 8 tank pretreatment of fabricated job before powder coating, the panel shall consist of the following switchgear:-Incomer- MCCB TPN 125 A 25kA adjustable thermal and megnatic relese-1 No, Out going- MCCB TPN 63A 16kA - 3 No,MCB TP 32A 10kA -2 Nos,MCB SPN 32A 10kA - 3 Nosmain aluminum bus bar shall be of 400A TPN, all inter connections to outgoing feeders shall be made with TPN aluminum bus bar of rating not less than the current carrying capacity of the respective feeder, all bus bars shall be covered with colour coded heat shrinkable sleeve, the complete panel shall be mounted on ISMC of 75x40mm duly painted with black paint. Digital Ammeter (0-400) with ASS-1No, Current transformer of suitable rating-3No, Digital Voltmeter with VSS(0-500)V-1No, RYB LED set-1, including suitable size of cable lugs and PCC foundation complete all as specified and directed by Engr-in-Charge (FP-2)
40Supply, installation, testing and commissioning of LT Panel Made out of CRCA sheet 3.15mm thick sheet steel, outdoor type, factory made by CPRI approved manufacturer, totally enclosed, dust and vermin proof (protection Class IP 54), (front opening) with locking arrangement, double door duly compartmentalized with extended canopy at the top, the panel shall duly powder coated with colour shade RAL 7035 Siemens grey Pure Polyester adopting 8 tank pretreatment of fabricated job before powder coating, the panel shall consist of the following switchgear:-Incomer- MCCB TPN 63 A 16kA adjustable thermal and fixed megnatic relese-1No, Out going- MCCB 3P 63A 10kA -01 Nos, MCCB SPN 32A 10kA - 6 Nos main aluminum bus bar shall be of 100A TPN, all inter connections to outgoing feeders shall be made with TPN aluminum bus bar of rating not less than the current carrying capacity of the respective feeder, all bus bars shall be covered with colour coded heat shrinkable sleeve, the complete panel shall be mounted on ISMC of 75x40mm duly painted with black paint. Digital Ammeter (0-400) with ASS-1No, Current transformer of suitable-3No, Digital Voltmeter with VSS(0-500)V-1No, RYB LED set-1, including suitable size of cable lugs and PCC foundation complete all as specified and directed. (FP-3)
41M&L for GI tubing brackets 40mm bore light grade with new GI tubing bracket 40mm bore light grade 1.20 metre length including MS clamp with nuts, bolts and washers etc including taking down old unsv complete all as specified and as directed.
42Supply, fixing and testing Street light automatic Nature switch of capacity 5 KW single phase complete with high and low voltage and overload protection, degree of protection confirm to 1P-55 AC, SP complete with suitable size MCB and power contactor etc, fixed on pole with 25 X 3mm MS strip clamp including provision of 6 sqmm 3 core cable for connection complete all as specefied and as directed.
43M&L for MS junction box made out of 2 mm thick sheet of size 130 x 70H with 4 Nos aluminium busbar of size 20 x 3 mm thick mounted on porcelain insulators with and including MCB, \"C\" curve, SP, 06 Amp - 01 No. including incoming and out going connections with necessary welding work, clamps and mounting on poles etc complete all as specefied and as directed.
44SEWAGE DISPOSAL WORKSNOTE:- For items of SEWAGE DISPOSAL WORKS notes given at the beginning of Sch ‘A’ Part-VIII (SEWAGE DISPOSAL WORKS) shall also be applicable.
45RCC Septic Tank (100 User)designed to carry sewage and sullage water excavation in any type of soil, PCC (1:4:8) below foundation, RCC M-30 Design mix in walls, Base slab, Baffle walls and roof slab including beam etc with vent shaft, manholes opening with cover connection etc, complete with effective depth of 1.5 meter and overall depth of 3 meter for 100 users.
46Soakage wells excavation in any type of soil, foundation in PCC 1:3:6 wells of honey combed and soild in M-25 concrete, including intercepting chamber, screen chamber Brick work in CM, RCC cover slab in M-25/RR masonary/Filling with brick bats, complete of size (3.0 m dia x 3.0M deep).
47RCC Septic Tank ( 50 Users) designed to carry sewage and sullage water excavation in any type of soil, PCC (1:4:8) below foundation, RCC M-30 Design mix in walls, Base slab, Baffle walls and roof slab including beam etc with vent shaft, manholes opening with cover connection etc, complete with effective depth of 1.5 meter and overall depth of 3 meter for 50 users.
48Soakage walls excavation in any type of soil, foundation in PCC 1:3:6 wells of honey combed and soild in M-25 concrete, including intercepting chamber, screen chamber Brick work in CM, RCC cover slab in M-25/RR masonary/Filling with brick bats, complete of size (2.4 m dia x 3.0M deep).
49COMPOUND WALL FENCING AND GATE WORKSNOTE:- For items of COMPOUND WALL FENCING AND GATE WORKS notes given at the beginning of Sch ‘A’ Part-IX (COMPOUND WALL FENCING AND GATE WORKS) shall also be applicable.
50Provn of steel gate 5.50 m wide in double leaf, including RCC (M-25) pillars, excavation and earth work, formwork, reinforcement bars, painting to steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer, three coats of white wash over plaster over pillars complete all as specified and directed by Engr-in-Charge.
51RAIN WATER HARVESTING WORKSNOTE:- For items of RAIN WATER HARVESTING WORKS notes given at the beginning of Sch ‘A’ Part-XI (RAIN WATER HARVESTING WORKS) shall also be applicable.
52M&L for Soakage wells excavation in ordinary soil, foundation in PCC 1:3:6 wells of honey combed and soild in M-25 concrete, including intercepting chamber, screen chamber Brick work in CM, RCC cover slab in M-25/SFRC interconnecting pipes of RCC/DWC complete Filling with brick bats, complete of size (3.6 m dia x 4.5M effective depth) complete all as specified and directed.
53M&L for Soakage wells excavation in ordinary soil, foundation in PCC 1:3:6 wells of honey combed and soild in M-25 concrete, including intercepting chamber, screen chamber Brick work in CM, RCC cover slab in M-25/SFRC interconnecting pipes of RCC/DWC complete Filling with brick bats, complete of size (3.6 m dia x 6.0 M effective depth) complete all as specified and directed.
54ARBORICULTURE WORKSNOTE:- For items of ARBORICULTURE WORKS notes given at the beginning of Sch ‘A’ Part-XII (ARBORICULTURE WORKS) shall also be applicable.
55Supply of following species of well grown (two year grown) healthy tree sapling with good root system & not less than 2 feet height and excavating a pit (0.6x0.6x0.6) and placing the sappling in the respective pit including watering, manure and spraying pesticieds etc as specified including replacement of dead plant and regular maintenance till the completion of maintenance period of two years (i.e, regular watering, dewedging of soil fortnightly, manuring & fertilising thrice, loosening anually training, pruning & stacking, spreading fungicides as and when required and directed (For Item No 11.02 to 11.12) :-
56Ashoka
57Amaltash tree
58Bottle Brush/ Palm tree
59Indica (Neem)
60Gulmohar
61sissoo (Shisham)
62Tamarind (Tamarindus indica)
63Jambulana (Jamun)
64Mangifera indica(mango)
65guava (Psidium guajava)
66Lemon tree
67Supply ofspecies of well grown healthy grass with good root system and placing the sappling in the respective area including watering and spraying pesticieds etc as specified including replacement of dead plant and regular maintenance till the completion of maintenance period of two years (i.e, regular watering, weeding, manuring & fertilising thrice, loosening anually training, pruning & stacking, spreading fungicides as and when required and directed.
68Sprinklersnetwork forwatering purpose in lawn area
69S&F tree guards made of welded steel wire fabric dia of wire not less than 2 mm dia supply and fixed to wood or steel members and supported with flat iron (25x5 mm) fillet (for securing the mesh) and three legs in angle iron (30x30x5 mm) welded to the tree guard below and insurting it into ground and preparation of new surface and priming with red oxide zinc chrome and applying two coats of synthetic enamel paints ordinary tint including necessary excavation and PCC 1:3:6 type C1 complete all as specified and directed.

Other Detail

Information Source https://defproc.gov.in/nicgep/app
Download FileName File Description File Size
Download drgsmerged.pdf Tender Documents 0 KB
Download tender.pdf Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Download fc9ab3b8-2bb3-4802-871e-4b6c4996bbf7.html Tender Documents 0 KB
Download BOQ_833998.xls Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.