| 1 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps i/c cutting and making good the same etc. as required at site. 100 mm |
| 2 | Providing and fixing G.I. union for G.I. pipe including cutting and threading the pipe and making long screws etc. complet. 100 mm |
| 3 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way double door |
| 4 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 5 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps |
| 6 | Supplying and fixing of following sizes of medium class PVC conduit/Batten along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 7 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 8 | S/F testing & commissioning of panel board 3 phase 4 wire system 415V, AC supply |
| 9 | Incoming1 No., VM 0-500V1 No. AM meter Analog 0-20V with in built selector switch 0-20 amps Outgoing1 Nos. DOL starter 1 No. single phase preventer1 No. OLR Indication light and ON/OFF buttonCompete with all accessories (stadium) |
| 10 | Providing and fixing of water level sensor for the existing pump etc. as required at site. (KSB) |
| 11 | Supplying and fixing of Syntex PVC Box size 18\"x18\" complete with all accessories i/c suitable clamps i/c making connection etc. as required at site. |
| 12 | Making foundation of suitable size for the steel work with cement concrete, sand cushioning and having MS plate with nut bolts and all accessories etc. as required at site. |
| 13 | Fully rewinding of following 12.5 HP sewage submersibile pump after cutting the existing winding with super enameled copper wire at the existing gauge i/c varnishing, heating etc. as required at site. (KSB) |
| 14 | Supplying and fixing of Bush for repairing of sewage submersible pump etc. as required at site. |
| 15 | Providing and fixing of 3 Hp motor of the hiring charging for the removing of water from the tank by the suitable arrangement etc. as required |
| 16 | S/F of 3x1.5 sq.mm PVC insulated PVC sheathed copper conductor flexible cable i/c connection etc. as required |
| 17 | P/f installation, testing and commissioning of 200 MCCB 35 KA capacity 3 pole 45volt AC supply complete with connection in the suitable |
| 18 | Removing of existing sewage submersible pump and refixing the same after repairing including connection etc. required at site. |
| 19 | Supplying and fixing of following items in submersible sewage motor pump set. |
| 20 | Mechanical seal |
| 21 | Mechanical seal upper |
| 22 | Bearing, housing, welding turning with bearinig fixing, leth work |
| 23 | Supplying and fixing of 4\" PVC corrugate pipe for the existing pump etc. as required at site. |
| 24 | 4\" PVC corrugated pipe |
| 25 | 3\" PVC corrugated pipe |
| 26 | S/f of following PVC insulated and PVC sheathed copper conductor flexible cable i/c connection etc. as required3x4 sq.mm |
| 27 | Servicing of ACB\"s 800 amps with proper tools and testing calibration of relay, equipments i/c racking out /in tightening of bolts cleaning with petrol/ CRC/ CTC and dry cloth etc. as required at site. |
| 28 | Supplying and fixing of 5 ton 3 m heavy duty chain pully ISI mark for the mtor taking out from the tank etc. as required at site. |
| 29 | S/F LED 72 watts street light fitting luminaire with pressure dia cast aluminium and heat resistance toughened flat glass complete with accessories top opening compartment with IP66 protection with 7200 lumens 220-240V i/c making connections etc. as required. (Model No. BRP409 LED CW 074 CW HE MR S1 PSU GR) (Philips or equivalent) |
| 30 | Supplying, fixing, and laying of one number PVC insulated and PVC sheathed/ XLPE aluminum armoured conductor power cable confirming to 1.1 KV grade of following size direct in ground including excavation, sand cushioning , protective covering, refilling the same etc. as required. 4 X 16 sq. mm |
| 31 | Providing and fixing of angle frame with steel work welded in built up sections/ framed work, including cutting, hoisting , fixing in position and applying a priming coat of approved steel primer of suitable size (0.60x0.60x0.60) including excavation and repairing the same etc. as required at site. |
| 32 | S/I/T/C of flood light fitting 5700K pressured dia cast housing with IP65 protection efficient high 220-240V output emitter LED for better distribution with dimension 447X 163X 327 mm and 6500 colour with lumens 21500 with all accessories etc. as required. at site. 150 watts (Model No. BVP410 LED 150 CW HE NB FG S4 XTFCL) (Phiilps or equivalent) |
| 33 | Suplying and fixing of street light pole box of size 8\"x10\" compete with all accessories i/c suitable clamps, suitable bakelite sheet brass screws, washers and 1 Nos. SP MCB 10 amps capacity i/c making connection etc. as required at site. |
| 34 | Supplying and fixing of 63 amps TPN MCb 415 volts in the existing MCB DB complete with connection etc. as required at site. |