| 1 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar |
| 2 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm. |
| 3 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixedglazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. |
| 4 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead. Of area 3 sq. metres and below. |
| 5 | Dismantling windows shutters including chowkhats, architrave, holdfasts etc complete and stacking within 50 metres lead. Of area 3 sq. metres and below. |
| 6 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 7 | Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. |
| 8 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm |
| 9 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of allT-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.5 mm thick fully Perforated / semi Perforated (as directed by Engineer-in-charge) lightweight calcium silicate tiles , of size 595x595 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.50, with 50 mm resin bonded glass wool backing. |
| 10 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 11 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) |
| 12 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) |
| 13 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm |
| 14 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 15 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 16 | Wall painting with acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.two caots |
| 17 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work |
| 18 | Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength in super structure above plinth level up to floor V level in : Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 19 | 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand) |
| 20 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 21 | Fixed to openings /wooden frames with rawl plugs screws etc. Supply of Venetian blinds Vertical blinds 100 mm wide with all accessories. |
| 22 | Supplying and fixing of 25mm size of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the samein case of recessed conduit as required. |
| 23 | Supply and fixing of 25 mmFRPP Flexible Conduit Pipe SWR reinforced Flexible Conduit Pipe. and fixing of 25 mmFRPP Flexible Conduit Pipe |
| 24 | Supply and fixing of 50mm X 50mm UPVC Mini Trunking along with Eternal Angle / Flat angle / Internal angle/T joints/ end caps and fasteners in complete as required including labour charges etc., |
| 25 | Supply and fixing of 32 mm X 12 mm UPVC Mini Trunking along with Eternal Angle / Flat angle / Internal angle/T joints/ end caps and fasteners in complete as required including labour charges etc., |
| 26 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 27 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit asrequired.2 X 2.5 sq. mm + 1X 2.5 sq. mm earth wire |
| 28 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit asrequired.2 X 4 sq. mm + 1X 4 sq. mm earth wire |
| 29 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.(including wire )4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 30 | Supplying, installation, Testing & Commissioning of36 watt Panellight 2x2 ft., of CRCA Sheet Body (Thickness ≥ 0.50 mm) and construction as per IS : 10322 with driver as per the requirementwith Driver efficiency >85%, Operating voltage AC140-270 Volt,freq50/60hz,Operatingtemprange-15degto40deg centigrade,internalsurge protection of 2.5 KV with Short & Open circuit protection,THD < 10% , P. F.≥0.95,IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free,(flicker should be below 5 %), life time (LED,Driver & electrical circuitry),of minimum50000 Burning Hours with , 70% of initialLumenmaintained tilllife ends ,CCT 3000°K /4000°K /5700°K /6000°K/6500°K(As perANSI Bin), SDCM(Standard Deviation Color Matching) <3,Maximumpower consumption should not more than the specified rating and Fixture shall be of relevant BIS standard andtrade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ EmbossingScreen printing on housing. completeinallrespecti/cconnectionswith 1.5sqmmFRLS,PVCinsulatedcopper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy>135lm/Watt output . LM79 & LM80 Test reportfromNABLlab foralltestingrequiredforLED fixtures as per BISshall be submitted.Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkofaluminumhousing such that LED junction temperature shall not rise above 90°C) Each 25 |
| 31 | Supply, Installation, Testing and Commissioning ofceiling fan1200mm,service value≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)with Brush LessDirectCurrent (BLDC)Motor,classofinsulation:B, 3 nos.metal(Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit,safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS :374-2019), THD (Total Harmonic Distortion) less than 10%,suitable for operation withregulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019fan Supply, earthing etc. complete as req |
| 32 | Supplying and fixing two module stepped type electronic fan regulator on theexisting modular plate switch box including connections but excluding modular plate etc. as required. |
| 33 | Supply and fixing of Anchor fastner with fan hook / Providing MS Fan hook with grouting and cement plastering |
| 34 | Providing and fixing extra conduit down rod of 20 mm dia, aproximately 100 cm length wiring with 2 X 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable including painting etc. as required. |
| 35 | Supplying and fixing 1 or 2 Module (75mmX75mm), GI/PVC box alongwith modular base & cover plate for modular switches in recess etc.as required. |
| 36 | Supplying and fixing suitable size GI/PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 6A modular socket outlet and 6A modular switch, connection etc. as required. |
| 37 | Supplying and fixing suitable size GI/PVC box with modular plate and cover in FRLS on surface or in recess, including providing and fixing 5/6 pin 16A modular socket outlet and 16A modular switch, connection etc. as required. |
| 38 | Supply and fixing of 16A/6A Triangle Plug Top. |
| 39 | Supplying and fixing of 12 way , Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But withoutMCB/RCCB/Isolator) |
| 40 | Supplying and fixing 6 way (4 + 18), Double door , horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 41 | Supplying and fixing Single pole MCB5A to 32 A rating, 240/415V, 10kA, C curve miniature circuit breaker suitable for inductive load of following poles in exsisting MCB DB complete with connections,testing and commissining etc.as required. |
| 42 | Supplying and fixing FP MCB 5A to 32 amps rating, 240/415V, 10kA, C curve miniature circuit breaker suitable for inductive laod of following poles in exsisting MCB DB complete with connections,testing and commissining etc.as required. |
| 43 | Supplying and fixing TPN(4 pole) MCB 63 amps rating, 415V, 10kA, C curve,ISI mark, miniature circuit breaker suitable for inductive laod of following poles in exsisting MCB DB complete with connections,testing and commissining etc.as required. |
| 44 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 45 | Supply and fixing of modular blanking plate on the existing modular plate & switch box excluding modular plate as required |
| 46 | Suplying and fixing of single pole blanking plate in the existing mcb DB complete etc. as required |
| 47 | Supplying, drawing, Installation, Testing and commissioning of 1 Run of cable CAT6 UTP LSZH 23AWG Twisted 275 DELHI SCHEDULE OF RATES (E&M)-2025 Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. |
| 48 | Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 Positions, 8 connectors. Housing: PC, UL94V-2, transparent color,Use for 24- 26 AWG stranded wires etc. complete as required. |
| 49 | Supply and fixing of TW / PVC Round Blocks required size etc. |
| 50 | Dismantling of the existing lights/fans/exhaust fans/switch boards/DB /PVC/ conduit and panel boards,shifting and handover to stores |