| 1 | 1. Supply, Installation, Testing and Commissioning of Walk in cold room made of 100 mm PUF panels with PPGI for internal and external surface for cold room along with other accessories having 01 no. of the 34” to 40”(W) x 72” to 80”(H) flush door 100mm PPGI finish both sides. The job includes civil works as per necessity and other allied works at site. The PUF panels shall be of make Sintex /Lloyd/Jindal.Material to be stored : Blood samplesAmbient Temperature: >=450CRoom Temperature : 20CPull Down Time : <=20 hrsRoom Size (External) : 10’×8’×10’Cold Room Structure:1) Room Size (External) : 10’×8’×10’2) Door Size: 34” to 40”(W) x 72” to 80”(H)3) Door Type: 100mm PPGI both side flush type door, Plastic curtains on the door way, flush type door with kick plate at bottom and fitted with door closer, Examination Window (View port), Seal closer mechanism. Heavy duty lock - lockable with 100% fail-safe provision for opening from inside.4) Wall panels: 100 mm thick PUF wall panels with density of 40±2 Kg/m3 for cold room with cam lock for PUF panels inter locking.5) Panel Finish: PPGI for both sides of panel (Corrosion and moisture resistant)6) Flooring: Aluminum checker plate 10 guage or 3mm thick with over insulated baseREFRIGERATION SYSTEM:Supply, installation, testing and commissioning of 01 no. refrigeration units (one main and one standby cold room machine) of minimum of 24000 BTU/hr capacity each along with evaporator Make: Bluestar, Voltas, Carrier. Job also includes supply and installation of other accessories such as expansion valve, control panels, U flashings, inner flashings and flat flashings and sealant etc. as per site requirement. Supply and Installation of MS frame in position and applying a priming coat of approved steel primer for ODU unit and for Isolator MCB with box with electrical wire with copper piping, drain work and other civil work as per site.1) Temperature Range: +1°C to +6°C2) Refrigerant: Eco-friendly as per norms/design3) System: Air-cooled4) Compressor: Reciprocating/Rotary5) Cooling capacity: Min. 24000BTU/hr @-4 evap. Temp. and Condensing temp of 540C6) Number of CDU: 01 No.7) Evaporator: Min. 24000BTU/hr 8) No. of Evaporator: 01 No with 03 No’s of Fans: 9) Supply: Three Phase10) Electric Load: 2.8KW/hr (approx.)11) Automatic Voltage Stabilizer: 7.5 kVA 3 Phase along with SITC of required assorted size cables as per site requirements for commissioning and running of whole installed system.ELECTRIFICATION:Proper electrification of cold storage room by way of providing and installation of power points, lighting, fans along with electric cables of assorted sizes as per site requirement. Complete job includes tapping of power supply from the main panel with cost of material, labour charges and all kind of taxes thereof. Complete job with cost of material, labour charges and all kind of taxes thereof. |
| 2 | Supply and Fixing of 04 Nos. SS-304 adjustable rack of size 4’-0”X 8’-0”X1’-0” with sheet thickness 1.0/0.8 mm in position along with required allied works for medicine storage size as per medical standards. |
| 3 | Chemical Earthing of DB by way of excavation of 01 no. pit of proper size upto a depth of 03m for providing and laying of 03 meter copper electrode 01 nos. in hard and soft soil followed by filling of required quantity of Earthing chemical. Job includes filling of pit with excavated soil and fitment of copper electrode with copper strip from electrode to machine. Complete job with cost of material, labour charges and all kind of taxes thereof. |
| 4 | Electrical work- Providing and Fitting of 02 Nos. TPN, Distribution board, aluminum (armoured) 25sqmmx4 core – 30 mtrs, 6 sq.mm Copper cable- 60 mtrs. |
| 5 | Miscellaneous work- Job includes minor Civil Works and repairs to the wall plaster wherever necessary, Alarm System for trapped person, Loading, all type of miscellaneous framework, Unloading, Freight, lock system, etc |
| 6 | SITC of 2.0 TR split air conditioners (Hot and Cold) with all accessories (along with outdoor stand) and ambient upper temperature range of >= 52 degree Celsius for cooling with Maximum cooling capacity >= 6500 W and for heating ambient lower temperature range <= 0 degree Celsius with Maximum Heating Capacity ≥ 6000 W having Air Flow Rate >=590 cfm with minimum 3 star and of reputed make i.e., O-General, Mitsubishi, Daikin, Hitachi, Bluestar along with allied accessories i.e. minimum of 10\" of refrigerant pipes and communication cable. Complete job as per site requirement and instructions of Engineer-in-charge and also includes cost of materials, labour charges, transportation charges and all other charges. |
| 7 | Supply, Installation, Testing and Commissioning of 5KVA copper wound automatic wall mounted voltage stabilizer input Voltage range of 90-300V & of superior quality ISI mark for ACs.Make: Microtek/Aulten/Servokon/Electricfield |
| 8 | Providing and fitting of SPN of 40 Amp of reputed make i.e. Havells, L&T with cover (complete with fittings) for 2.0 TR Capacity ACs to be installed. |
| 9 | Providing and fitting of extra copper pipe with insulation. |
| 10 | Providing and laying (using conduits and wire fasteners / cable clips) ) of 10 sq mm 4 core multistrand flexible ISI Marked, FRLS PVC insulated copper conductor cable and of standard make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of connecting stabilizers to the electrical panel. Complete job as per instructions of Engineer-in-charge and site requirements and also includes cost of materials (including clamps, bends/elbows, Tee-bends, thimbles etc.), labour charges, transportation charges and all other charges and taxes. |
| 11 | Providing and laying of (using conduits and wire fasteners / cable clips/conduit fasteners) 4 sq mm ISI Marked, FRLS PVC insulated copper conductor cable of standard make i.e. Havells, Polycab, Finolex, Anchor only for the purpose of connecting air conditioning units (Outer & Inner) to the Stabilizer. Complete job as per instructions of Engineer-in-charge and site requirements and also includes cost of materials (including clamps, bends/elbows, Tee-bends, thimbles etc.), labour charges, transportation charges and all other charges and taxes. |
| 12 | Providing and laying of PVC drain pipes of assorted sizes viz. ¾”, etc. to collect and transport the drained water from the AC unit to a designated location, considering the specific requirements of the site. The PVC pipes will be installed with appropriate size bends and clamps to ensure proper alignment and secure connections. Job also Includes miscellaneous works Civil works like wall opening to pass ducts & pipes, plastering & refinishing of the same to the original finish as per the site requirements. Complete job as per instructions of Engineer-in-charge and site requirements and includes cost of materials (including clamps, bends/elbows, nipples, Tee-bends, etc.), labour charges, transportation charges and all other charges and tax. |
| 13 | Providing, Fitting and Testing of Air Curtains at the Main entrance of Blood Bank at GMCH Jammu The Air Curtain should be in a metal casing, strong, fire resistant, simple installation and easy cleaning. They should have double air way deflectors design obtaining an even air stream so that it creates an invisible air barrier over the doorway that prevents the inner cool/warm air from going outside and also prevents insects , dust etc from entering inside the ward. All the Air Curtains have to be fixed on the 8 mm Ply board fitted and hung by sides . The specifications of Air Curtain should be:Material of cabin-- Cold rolled mild steel1. Base Plate- 16 SWG2.Body- 18 SWG 3.Grilles- 20 SWG4. Blower Housing- 20 SWG5. Length- 6’.00” of curtainInterior Finish- Anti Rust treatment with Primer paint, Exterior Finish- HT Paint/Stove painting (Powder Coating), Fans and Motors- The multiple forward curved centrifugal type Aluminum Fan wheels statically and Dynamically balanced driven by extended motor shaft. The job also includes providing and fitting of 4mm sq wire of suitable length to be connected to the main power supplies of each unit, SPN’s- 1 No’s with covers, baton, PVC clamps and gutties etc as per site requirement Complete Job includes cost of Material, Transportation, labour charges and all types of taxes. |
| 14 | Repair and cleaning of ducts of Air conditioning at various locations of Blood Bank of GMCH Jammu by way of removal of vent grilles and diffusers for manual cleaning using industrial-grade HEPA-filtered vacuums, soft-bristle brushes, and compressed air tools to eliminate dust, debris, and other particulate buildup from the visible portions of the duct openings and repair to all the damaged vents as per site requirement so that the air flow reaches the last end duct. All debris collected during the cleaning will be properly contained and disposed of offsite. After cleaning, all vents and will be securely reinstalled and airflow tested to confirm proper operation. A visual inspection and photographic documentation of cleaned vents will be included in the final job report. The job includes replacement of damaged Power coated Aluminium Extruded Grill. Complete job includes cost of material, consumables,labour and all types of taxes etc |
| 15 | Providing and Fitting of 4K HDMI Cable 5 Meter |
| 16 | 55” LED TV 4K for 24x7 Operations with UHD Dimming And Auto Motion PlusMake: Samsung/Sony/Sansui |
| 17 | Supply & Installation of 5 MP IR Fixed network Dome/Bullet Camera- suitable for outdoor operation with following specifications along with accessories required for fitting. 30 meter IR, 1/2.7\" Progressive Scan CMOS Color: 0.0125 Lux @ (F2.0, AGC ON) 0 Lux with IR, Resolution: 2592 × 1944 or better ,WDR should be 120dB or higher, 3.6mm,Mic and Speaker Inbuilt , Camera Shall have IP67 Ingress Protection and CE, FCC, UL, ROHS,CMMI-5 , ,WEEE certificationsMake: Hi Focus/Matrix/Prama |
| 18 | Supply & Installation of 16Channel 2 SATA Network Video Recorder-for encoding and processing the video data at the camera ,then streaming to the NVR Recorder for storage and remote viewing with following specifications and features. NVR Shall Support up to 12 MP or higher,NVR Shall Support 4K (3840 × 2160) ,NVR Shall Support 16-ch playback,TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS ,NVR Shall Support 02 SATA interface. NVR Shall Support up to 16 TB capacity for each HDD,1 RJ-45 10/100/1000 Mbps, NVR shall Support SH.265,H.265+,H.265,H.264 Video Compression, Onvif Compatible,shall have CE, FCC, UL, BIS,ROHS,CMMI-5 ,WEEE certificationsMake: Hi Focus/Matrix/Prama |
| 19 | 4 TB AV HDD Make: Seagate/WD/Toshiba |
| 20 | Providing & fitting of Rack 4U with Glass door and lock Fully loaded conforms to DIN 41494 & IEC 297 , ISO 9001:2015 standards Make: Comrax/ President/APC |
| 21 | Supply & Installation of 8 port GIGA PoE Switch,With 8*10/100/1000Mbps ports1-8 + 2*10/100/1000 ports 9-10 PoE ports, Full Duplex ; 1000 Mbps, ,PoE Power Budget: 96W,Standards: IEEE 802.3, IEEE 802.3u, IEEE 802.3ab IEEE 802.3xl IEEE, Packet Forwarding Rate: 14.88Mbps, 8K Mac address Table, Packet Buffer Size 192KB Make: Hi Focus/Digisol/D-link/Netgear |
| 22 | Providing & fitting of Conduit 25mm along with clamps etc. |
| 23 | Providing/Supply, Installation, Testing & Commissioning of CAT-6 Outdoor cableCat6 4-Pair U/UTP outdoor double-jacketed cable with Frequency range: 1-250 MHz, 23AWG ( 0.55mm) Solid bare Copper conductor, High-density polyethylene(HPDE) color coded as per ANSI/TIA-568 2-D Insulation,Cable core: 4 Twisted ppair held in place by HDPE cross-web separator,Water Resistant: Jacket only,Inner Jacket: LSZH Grey, Outer Diameter:7.0mm nominal,Outer Jacket: UV resistant HDPE for outdoor use, BlackMake: AMP/ Honeywell/Commscope/Comrax |
| 24 | Providing & laying of Power Cable with 3 Core ,2.5 sq.mm ,Copper Make: Finolex/ Havell/ |
| 25 | 1KVA Online UPS with 60 minutes SMF Battery Backup with RACK Make: Elnova/FUJI/APC |
| 26 | Providing and fitting of RJ 45 Jacks which includes Crimping at both the Ends of the Cable |
| 27 | Integration, Testing &Commissioning all the equipments and system for proper functioning Please Enable Macros to View BoQ information |