| 1 | Earthing with GI Earth pipe 4.5longx40mm dia i/c accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etcwith charcoal or coke and salt complete as required. |
| 2 | Providing and fixing 25mm x 5mm GI strip on surface or in recess for connections etc as reqd |
| 3 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm |
| 4 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm |
| 5 | LED Flood Light, powder coated pressure die cast aluminum (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).100 Watt |
| 6 | Supplying and fixing following sizes of insulated steel flexible safety rope for holding submersible pump set i/c clips etc complete as reqd.(a)10mm |
| 7 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting andcutting, jointing etc..in the existing trenchcomplete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 8 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 9 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) 63 amps |
| 10 | Supply of PVC sheathed XLPE insulated copper conductor armoured control cable of 1.1KV grade as per IS 7098/1988 of 6C*2.5 Sq mm as reqd |
| 11 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.(a) 2x2.5 sq. mm |
| 12 | Supply of XLPEinsulated and PVC Sheathed Al conductor armoured cables conforming to IS-7098 (Part-I)/1976 as required.2x 6 sqmm |
| 13 | Supply and fixing ofHot press sheet mouldedcompound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proofpole window door suitable for 12M semi high mast pole etc as reqd. |
| 14 | Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size 25mmx75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh including MV danger plate and grounding the protection system in suitable quality of CC etc as reqd. |
| 15 | Providing and Fixing of Stainless steel name plate of size 6x8 sq inch made of 20 gauge sheet including engraved name of area representative duly painted along with SS clamp nut bolt etc as required. |
| 16 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 17 | Shifting of one number of 12 Mtr Semi high mast light systemwith its accessories and reinstallation ,testing ,Commissioningthe same on suitableRCC (1:2:4) shallow foundation of size 1m(L) X 1m (wide) and 2 Mtr deep i/c excavation of earth providing cutting bending and placing in position reinforcement of cold twisted bar of 12 mm -2100 long(approx) -16 nos and reinforcement of cold twisted bar of 8 mm-3700 mm (approx)- 13 nos (with 150 mm spacing) as required with Positioning of foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for the high mast Considering the safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material plate as reqd suitable for12 meterpoles. |