| 1 | Excavation in trenches in soft/ loose soil n.exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out, complete all as specified and directed. |
| 2 | M&L for cement concrete 1:4:8, type D-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete and sub base of floor complete all as specified and directed. |
| 3 | M&L for Reinforced cement concrete type M 25 (design mix) (20mm graded aggregate) in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc. basement slabs, under-reamed piles and mass concrete, complete all as specified and directed. |
| 4 | M&L for Reinforced cement concrete type M 25 (design mix) (20mm graded aggregate) in columns, pillars, piers, posts and struts, complete all as specified and directed. |
| 5 | M&L for Reinforced cement concrete type M 25 (design mix) (20mm graded aggregate) in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and directed. |
| 6 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter fair finished surface, complete all as specified and directed. |
| 7 | M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions rough finished surfaces of concrete, square, rectangular or polygonal in shape, complete all as specified and directed. |
| 8 | M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, complete all as specified and directed. |
| 9 | Returning, filling in soft/ loose soil including spreading, levelling, watering and well ramming in layers n.exc 25 cm, in any type of soil, complete all as specified and directed. |
| 10 | Removing excavated material exc. 250 m but n. exc. 500 m and depositing where directed, complete all as specified and directed. |
| 11 | M&L for Brick work with fly ash bricks, straight or curved on plan exc 6m mean radius built in CM (1:4), complete all as specified and directed. |
| 12 | M&L for 40mm thick 1:2:4 type B0 damp proof course in horizontal or vertical surfaces including necessary frame work complete all as specified and directed. |
| 13 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 14 | All as per Srl item No.13 above but 5mm dia and over up to and incl 10mm dia as in stirrups, complete all as specified and directed. |
| 15 | M&L for precast cement concrete 1:2:4, type B-0, (using 12.5mm graded stone aggregate), in 35mm thick jallies or louvers including all mouldings complete and set in cement mortar 1:4 complete all as specified and directed. |
| 16 | M&L for 15mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces and finishing surfaces even and smooth without using extra cement complete all as specified and directed. |
| 17 | M&L for PCC 1:3:6 type C-2 (using 20mm graded stone aggregate) as in copping link including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 18 | M&L for preparation of new plastered surfaces of walls and applying finishing walls with acrylic smooth exterior paint of required shade. New work (Two or more coat applied @ 1.67 ltr/ 10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 Sqm, complete all as specified and directed. |
| 19 | M&L for 10mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces complete all as specified and directed. |
| 20 | M&L for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete for Fe 410-W (grade E-250 quality -A), complete all as specified and directed. |
| 21 | S & F 1.60mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, weded to steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required, complete all as specified and directed. |
| 22 | M&L for Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290. grade E-165, complete all as specified and directed. |
| 23 | M&L for two coats of synthetic enamel paint over a coat of red oxide primer incl preparation of steel surfaces complete all as specified and directed. |
| 24 | S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165. |
| 25 | M&L for 20mm thick Granite (of any type) tiles machine cut in skirting/ dado laid over cement screed bedding layer or mortar 15mm layer of mortar 15mm thick for laying floor finishes in CM 1:4 and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing, complete all as specified and directed. |
| 26 | Demolition of reinforced cement concrete of any description & in any position not otherwise described complete all as specified and directed. |
| 27 | Demolition of stone brick masonry built in cement mortar including quoins arches, etc. but exceeding ashlar facing dressed stone work etc. complete all as specified and directed. |
| 28 | Dismantling of plan or corrugated steel sheeting any gauge, thickness, including nainaital or similar pattern roof coverings complete all as specified and directed. |
| 29 | Dismantling wrought iron or mild steel work of any description complete all as specified and directed. |
| 30 | M&L for Point wiring with 1.5 Sqmm (nominal cross sectional area), single core, PVC insulated with multistranded PVC unsheathed FRLSH copper conductor cable in and including rigid non- metallic PVC surface conduit/ surface/ casing capping of suitable size medium grade ISI marked complete, including one continuity earth wire of PVC insulated, unsheathed 1.5 Sqmm (nominal cross sectional area) FRLSH copper conductor connected to all fittings, common earth and connected to earth dolly including modular GI sheet metal/ PVC flush box, covered with modular white cover plate with inner frame suitable for modular switches and blank plates of suitable size all fittings and accessories andmaking good disturbed surface of walls and floors etc. complete all as specified and directed for the following:-Note:- Make of modular GI flush box/PVC box should be same with switch/ socket and type of wiring i.e concealed/ surface/ casing caping will be executed as per site requirement and direction by Engr-in-Charge.(a) One 3 pin, 5/6 Amps socket outlet point on independent board controlled by one, one way 5/6 Amps switch |
| 31 | M&L for Point wiring with 2.5 Sqmm (nominal cross sectional area), single core, PVC insulated with multistranded PVC unsheathed FRLSH copper conductor cable in and including rigid non- metallic PVC concealed conduit/ surface/ casing capping of suitable size medium grade ISI marked complete, including one continuity earth wire of PVC insulated, unsheathed 2.5 Sqmm (nominal cross sectional area) FRLSH copper conductor connected to all fittings, common earth and connected to earth dolly including modular metal flush box, modular cover plate and modular cover frame of suitable size all fittings and accessories and making good disturbed surface of walls and floors etc. complete all as specified and directed for the following:-Note:- Make of modular GI flush box/ PVC box should be same with switch/ socket and type of wiring i.e concealed/ surface/ casing caping will be executed as per site requirement and direction by Engr-in-Charge. |
| 32 | S&F Modular switch 1 way 6 A, 1 module complete all as specified and directed. |
| 33 | S&F Modular socket 6 Amps 2/3 pin combined2 module complete all as specified and directed. |
| 34 | S&F Switch modular type 16 A, 1 module complete all as specified and directed. |
| 35 | S&F Socket modular type multipurposes 6/16 A, 2 module complete all as specified and directed. |
| 36 | M & L for sub main wiring with 02 runs of 4 Sqmm main wire along with 01 run of 04 Sqmm earth wire (green in colour) single core FRLSH PVC insulated, unsheathed, multi-stranded, 1100 volts grade ISI marked copper conductor cable, drawn through and including adequate size rigid non-metallic PVC concealed/ surface conduit (medium grade) wherever necessary with all fittings & accessories including cutting chases for conduits as required, sinking for terminal boxes, making good the same complete all as specified and directed.Note:- Two runs of maincopper conductor, one run of earth wire of same size and one run of PVC conduit shall be measured as one unit length. |
| 37 | S&F of exhaust fan, steel body AC single phase 230 Volt of size 300mm sweep complete with blade, frame and louvers and mesh wire for cover the wall from outside including addition/ alteration of hole wherever necessary and making good disturbed surface, painting to match with existing surfaces. complete all as specified and directed. |
| 38 | S & F for water heater storage type (Geyser) vertical/ Horizental type as per site requirement with inner container of capacity 25 ltrs, electrically operated, AC 230 Volts, BEE 5 star rated, ISI marked including 04 Nos of hold fashner nuts required suitable size fixed in brick wall, hot & cold (upto 3 feet long) water stainless steel geyser connection pipe(two pipe = one set) for Officers JCO\"s and OR Md Accn including making good of disturbed surface to match with existing colour and writting the MES Number with synthetic enamel paint complete all as specied and as directed.Note:- The rate of hot and cold water stainless steel (SS) geyser connection pipe (set) shall be deemed to be included in the quoted rate. |
| 39 | S&F MCB DB SPN 8 way double door with 200 Amps rated bus bar, 230 volts, 50 Hz including necessary provision for inserting the DBs in wall by cutting the brick/ stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed. |
| 40 | S&F 32 Amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) of SPN 32 Ampsand current carrying capacity in the MCB DB complete with connection testing and commissioning. complete all as specified and directed. |
| 41 | S&F MCB Single pole rated capacity 6 to 32 Amps, 240 Volts breaking capacity 10 KA, \"C\" curve complete all as specified and as directed. |