Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Dismantaling & Demolishing. |
| 2 | Demolishing cement concrete with Stone/ Brick bats manually/ by mechanical means including disposal of material within College campus lead as per direction of Engineer - in - charge. |
| 3 | (a) Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 4 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within College campus lead as per direction of Engineer - in- charge. Note:- While demolishing work, vendor should take all safety mearsure bykeepingsand bags, horizontla and vertical M.S. props for supporting and M.S. Jali above the floor and cover doors, windows, Electrical Switch board & Smart board with ply board & Polysheet as per dirction of EIC so that the demolishing work effect does not harm our existing under floor & roof. - No extra payment will be made for this protection work. |
| 5 | Extra for cutting reinforcement bars manually / by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineer-in-charge. |
| 6 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, all loads including all lifts involved. Note:- Malba quantity is equal to dismantled material/items. No factor will be calculated in MB) |
| 7 | Earth Work. |
| 8 | Providing Pest Control and Anti-Termite Treatment by appointing a specialised agency as per the secifications mentioned by the bureau of indian standards and agencies specfications (whichever is higher), for general civil, plumbing/ drainage and timber/ carpentary works, gypsum related work, including a 10-Year Guarantee Bond under suitable undertaking on stamp paper etc., complete as directed.(Mode of measurement to be on carpet floor-area & Double height area to taken only one time .) |
| 9 | Concrete Work. |
| 10 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centring, shuttering and finishing : |
| 11 | (a) 1:2:4 (1 Cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 12 | Providing and laying of piecesof Autoclaved Aerated Concrete blocks in sunken portion as per direction Engineer-in-Charge. |
| 13 | Reinforced Cement Concrete Work. |
| 14 | Reinforced cement concrete work in walls (any thickness), slab & beam including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level excluding cost of centering, shuttering, finishing and reinforcement: Cement Make:- ULTRATECH,JK,AMBUJA, BIRLA, ACC . |
| 15 | (a) 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size). |
| 16 | Providing and laying in position machine batched / machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.(Note :- Cement content considered in this item is @ 350 kg/cum. Excess/less cement used as per design mix is not payable/recoverable separately) Note:- Batch plant will be approved by Architect. |
| 17 | (b) All works up to floor V level. |
| 18 | (b-1)Concrete of M 25 grade with minimum cement content of 330 kg /cum |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form forup to 9.0 metres. Height with water proof ply 12mm thick. |
| 20 | (a) Columns, Pillars, Piers, Abutments, Posts and Struts. |
| 21 | (b) Edges of slabs and breaks in floors and walls. |
| 22 | (c)Under 20 cm wide |
| 23 | (c-1) Weather shade, Chajjas, corbels etc., including edges. |
| 24 | (d) Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12mm thick. |
| 25 | (e) Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12mm thick. |
| 26 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Make:- Tata, Sail. |
| 27 | (a) Thermo-Mechanically Treated bars. |
| 28 | Brick Work. |
| 29 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level including exposed brick work with making horizontal and vertical grooves 10 mm wide 12 mm deep all shapes and sizes in : |
| 30 | (a) Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 31 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. |
| 32 | (a) Cement mortar 1:4 (1 cement :4 coarse sand) |
| 33 | Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry. |
| 34 | Providing and laying autoclaved aerated Concrete blocks masonry with 150mm to 300 mm thick with Grade 1 AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer in-Charge.(The payment of RCC band and reinforcement shall be made for separately). |
| 35 | Granite / Marble Work. |
| 36 | Providing and fixing 18mm thick gang saw cut mirror polished premoulded and prepolished) machine cut for kitchen platforms, vanity counters, window sills, facias, flooring and similar locations of required any size of approved shade, colour and texture laid over 20mm thick base cement mortar 1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing,all type of moulding (full or half round) and polishing to edges to give high gloss finish etc. complete at all levels. Basic Price :- Rs.300/-Sqft. |
| 37 | (a) Granite of any colour, shade & of any size. (sample approved by Principal/ Architect) |
| 38 | Providing edge moulding (full round) to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. |
| 39 | (a) Granite work. |
| 40 | Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 41 | Providing and fixing Ist quality vitrified wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades of any sizeas approved by Engineer-in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete. Make:- Kajeria, Somany, Asain, Orient. Basic Rate :- 65/Sqft. |
| 42 | Aluminium work. |
| 43 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters including all SS fittings Like sliding door bolt, Hinges, tower bolt, motich lock, handle & door stopper as per Direction Engineer-in-Charge. |
| 44 | (a) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 45 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). |
| 46 | Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured) : |
| 47 | (a) Rectangular or square. |
| 48 | Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : |
| 49 | (a) 2nd class teak wood |
| 50 | (a-1) 50x12 mm |
| 51 | Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S including cost of adhesive of approved quality. Make:- Merino, Century, Greenlam. |
| 52 | (a) 1.5 mm thick. |
| 53 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : |
| 54 | (a) Float glass panes |
| 55 | (a-1) 4 mm thick glass pane .Make:- Modi. |
| 56 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including the cost of dash fastener/ Hold Fast(4 nos. on each side), necessary filling up the gaps at junctionsi.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket & silcone for gap between frame & wall area)etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling to be paid for separately) : Make: Jindal, handalco, Mahvir. |
| 57 | (a) For fixed portion |
| 58 | (a-1) Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 59 | (b) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately). |
| 60 | (b-1)Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 61 | Supply and installation of aluminium powder coated threetrack sliding type windows With safety grills with the all necessary locking arrangement of size 1200mmx 1800mm x 80mm with 16 gauge with one fix glazed ventilatoras per Drawing inclosed as per CPWD specification in existing puff panel wall / cement board partition wall of porta cabin at Ground floor& First Floor faculty department Rooms after making opening in existing puff wallas per direction of EIC. The thickness ofglass of 5.5 mm fixed with EPDM rubber/ Neoprene Gasket. |
| 62 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. |
| 63 | a) Pre-laminated particle board with decorative lamination on both sides. |
| 64 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): Make:- Saint gobind, Modi. |
| 65 | (a) With float glass panes of 5.50 mm thickness |
| 66 | Providing and fixing Powder coated aluminium grill of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). |
| 67 | Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : |
| 68 | (a) 125x64x2.50 mm |
| 69 | (b) 100x60x2.50 mm |
| 70 | Providing and fixing S.S. sliding door bolts ISI marked with nuts and screws etc. complete : |
| 71 | (a) 300x16 mm |
| 72 | Providing and fixing S.S. tower bolts ISI marked with necessary screws etc. complete : |
| 73 | (b) 250x10 mm |
| 74 | (c) 200x10 mm |
| 75 | (d) 150x10 mm |
| 76 | (e) 100x10 mm |
| 77 | Providing and fixing S.S. handles ISI marked with necessary screws etc. complete : |
| 78 | (a) 125 mm |
| 79 | (b) 100 mm |
| 80 | Providing and fixing S.S. hanging floor door stopper ISI marked with necessary screws etc. complete. |
| 81 | (a) Twin rubber stopper |
| 82 | Providing and fixing S.S. casement stays ISI marked with necessary screws etc. complete. |
| 83 | Steel Work. |
| 84 | Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs, beams during laying including painting the exposed portion of loop, all as per standard design complete. |
| 85 | Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 86 | (a) In gratings, frames, guard bar, ladder, railings, Grills, brackets, gates and similar works. Make:- Jindal, Tata. |
| 87 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. (for payment purpose only weight of stainless steel members shall be considered including fixing accessories such as nuts, bolts, fasteners etc.) |
| 88 | Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 40x40x5 mm, joints mitred and welded by angle iron 40x40x5 mm or 35x5mm / 40x5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener/ Hold Fast (4 nos. on each side), including fixing of necessary butt hinges and screws, dash fastener , Hold Fast and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. |
| 89 | Flooring Work. |
| 90 | Providing and laying full body vitrified floor tilesin different sizes (thickness to be specified by the manufacturer) with water absorption\"s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. (Make -Somany/ Kajaria/ Asian/Orient). Basic Rate :- 75/-Sqft. |
| 91 | Providing and laying non- skid vitirified tiles in different sizes (thickness to be specified by manufacturer) with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make in all colours & shade in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.(For Toilet Block) (Make -Somany/ Kajaria/ Asian/Orient). Basic Rate :- 75/-Sqft. |
| 92 | Providing and laying Tactile tile (for vision impaired persons as per standards) of size 300mmx300mmx15mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc.complete as per direction of Engineer-in-Charge. (Make -Somany/ Kajaria/ Asian/Orient) |
| 93 | Providing and laying Heavy Duty vitrified floor tiles (Stone Grade)Size of Tile 600x600 mm having thickness 16mm with 08mm thick joint ( with PVC Spacer) with water absorption\"s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand)complete. including the cost of Grout of joint & spacer. (Make -Somany/ Pavit/ Kajaria/ Asian/Nitco) (The Basic Price Rs. 125/- sqft) |
| 94 | Roofing. |
| 95 | Providing and fixing on wall facePVC rain water pipes conforming to IS : 13592 Type A including Tee, Band, coupler, Grating & jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. |
| 96 | (a) 110 mm |
| 97 | (a) 160 mm |
| 98 | Providing and fixing Metal Tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metalgrid of hot dipped galvanized steel sections (galvanized @ 120gsm/sqm, both side inclusive) consisting of main T\" runner withsuitably spaced joints to get required length and of size 24x38mm\" joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross \"T\" of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main \"T\" at 600mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. |
| 99 | Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 x mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-charge. |
| 100 | GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5mm thick with 8mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. |
| 101 | Finishing. |
| 102 | 6 mm cement plaster of mix : |
| 103 | 1:3 (1 cement: 3 fine sand) |
| 104 | 12 mm cement plaster of mix :of all height. |
| 105 | (a) 1:4 (1 cement: 4 fine sand) |
| 106 | 15 mm cement plasterof all height on rough side of single or half brick wall of mix : includingwater proofing material in cement plaster work in proportion recommended by the manufacturers of all height. |
| 107 | (a) 1:4 (1 cement: 4 fine sand) |
| 108 | Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement: 3 fine sand) :of all height |
| 109 | (a) Flush / Ruled/ Struck or weathered pointing. |
| 110 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade of all height. |
| 111 | (a)Old & New work (two or more coats) over and including water thinnable priming coat with cement primer. |
| 112 | Finishing walls with Acrylic Smooth exterior paint of required shade :of all height. |
| 113 | (a) Old & New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
| 114 | Providing and applying two coats of fire retardant paint on cleaned wood/ply surface @ 3.5 sqm per litre per coat including preparation of base surface as per recommendations of manufacturer to make the surface fire retardant of all height. |
| 115 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete of all height. |
| 116 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : of all height. |
| 117 | (a) One or more coats. |
| 118 | Sanitary Installations. |
| 119 | Providingandfixingwhitevitreouschinapedestaltypeor wall hung watercloset (European type) with seat and lid,(sample Approved by college) 10 litre low level white vitreous china flushingcistern&C.P.flushbendwithfittings&C.I.brackets,40mm flushbend,overflowarrangementwithspecialsofstandardmakeand mosquitoproofcouplingofapprovedmunicipaldesigncomplete including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Make:-Hindware, Cera, Jaquar, Somany. |
| 120 | (a) W.C. pan with ISI marked white solid plastic seat and lid. |
| 121 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap,(sample Approved by college) 10 litre low level white P.V.C. flushing cisternincluding flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests.Make:-Hindware, Cera, Jaquar, Somany. |
| 122 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mmwithwhitePVCautomaticflushingcistern,(sample Approved by college) with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps(allinC.P.brass)withwastefittingasperIS:2556,C.I.trap withoutletgratingandothercouplingsinC.P.brassincludingpainting offittingsandcuttingandmakinggoodthewallsandfloorswherever required : Make:-Hindware , Cera, Jaquar, Somany. |
| 123 | (a) Single halfstall urinal with5litre P.V.C. automatic flushing cistern |
| 124 | Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. |
| 125 | Providing and fixing wash basin above/ under counter or wall hung with C.I. brackets, 32 mm C.P. brass waste of standard pattern,including ,waste coupling, jalli, connection & painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Flat back under counter/ above counter / without counter ( pedistal) Wash Basin size600x400 mmMake:-Hindware, Cera, Jaquar, Somany. |
| 126 | Providing and fixing S.S. Waste Coupling 32mm Size Full Thread completewith jalli for wash basinsinkapproved quality . Make:-Hindware, Cera, Jaquar, Somany. |
| 127 | Providing & Fixingfollowing toilet accessories complete including extension nipple & making hole in granite counter & r.c.c slab, & wall tile as per following detail :-Make:-Hindware, Cera, Jaquar, Somany, Kohlar. |
| 128 | (a) Concealed stopcock with long sleeve sliding cap(Basic rate Rs.700/-) |
| 129 | (b) Angular stop valve with wall flange ( Basic rate Rs. 750/-) |
| 130 | (c) 15 mm diameter small body bib cock wit extension nipple(Basic rate Rs. 500/-) |
| 131 | (d) Bottle Trap (Basic rate Rs. 650/-) |
| 132 | (e) Health Faucet / Jet (Basic rate Rs. 600/-) |
| 133 | (f) Towel Ring / cloth hager /clip |
| 134 | (g) CP Ext Pcs of required length as per site condition. |
| 135 | (h) Trap Jali - 5\" dia ( SS 304 grade) |
| 136 | (i) P/F CP brass swan neck wash basin mixer of 12\" height fixed to existing counter basin |
| 137 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 138 | (a) Flexible pipe - 40 mm dia |
| 139 | Providing and fixing mirror of superior glass (of approved quality) fixed on 6mm thk ply fixed on wall and of required shape and size with S.S. Stud & Bevel edge of approved make as per Direction Engineer-In-Charge.Make:- Saint Gobin, Modi. |
| 140 | (a) Rectangular shape |
| 141 | Urinal Modesty Panel:- Size:- 450mm x 900mm including all Accessories:-design & color scheme will be approeved by college principal. Make: Merino, Greenlam. |
| 142 | \"Providing & fixing Ringfit / Pasting Type uPVC (Type-B) conventional system for Soil, Waste & Rain Water including cost of Coupler, Bend, Tee, Single Y, Vent Cowl, End cap, coolar, terminal guard,Clip, ClampM.S. Holder-bat clamps & testing of joints complete including the cost of cutting holes and making good the wall/RCC area , etc as per direction of Engineer in Charge. Make - Astral / Supreme / Prince / Prakash |
| 143 | (a) 75 mm dia |
| 144 | (a-1) Pipe |
| 145 | (b)110 mm dia |
| 146 | (b-1) Pipe |
| 147 | Water Supply. |
| 148 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes cost ofjointing of pipes, cutting of holes in brick work/rcc area & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall Make : Supreme, Prakash, Polycab, Astral. |
| 149 | (a) 15 mm nominal outer dia .Pipes. |
| 150 | (b) 20 mm nominal outer dia .Pipes. |
| 151 | (c) 25 mm nominal outer dia .Pipes. |
| 152 | (d) 32 mm nominal outer dia .Pipes. |
| 153 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases, cutting of holes in brick work/rcc areaand making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. -Make : Supreme, Prakash, Polycab , Astral . |
| 154 | (a) 15 mm nominal outer dia .Pipes. |
| 155 | (b) 20 mm nominal outer dia .Pipes. |
| 156 | (c) 25 mm nominal outer dia .Pipes. |
| 157 | (d) 32 mm nominal outer dia .Pipes. |
| 158 | Making connection of CPVC / G. I. distribution branch with CPVC / G. I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :Make : Supreme, Prakash, Polycab, Astral . |
| 159 | (a) 20 to 40 mm nominal bore |
| 160 | (b) 50 to 80 mm nominal bore |
| 161 | Cutting holes up to 30x30 cm in walls/RCC slab/RCC beams including making good the same: |
| 162 | (a) With common burnt clay F.P.S. (non modular) bricks. |
| 163 | Cutting holes up to 15x15cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including finishing complete so as to make it leak proof. |
| 164 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Make: Sintex, Supreme, Finolex |
| 165 | DRAINAGE. |
| 166 | Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round all size pipes including bed concrete as per standard design: |
| 167 | Stucture Repair. |
| 168 | Chipping of existing unsound/weak concrete with plaster material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge Note:- While Chipping vendor should take all safety mearsure bykeepingsand bags, propsand MS Gali above the floor and cover doors, windows, Electrical Switch board & Smart board so that the Chipping work effect does not harm our existing under floor & roof , if required. No extra payment will be made for this protection work. |
| 169 | (a) Above 50mm to 75mm thickness (Beams Bottom & Top surface) |
| 170 | (b) up to 50mm thickness (Exiting roof slab & beams side) |
| 171 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge. |
| 172 | Bars up to 12 mm diameter |
| 173 | Bars above 12 mm diameter |
| 174 | Supplying and applying anti corrosive treatment with two component Zinc rich epoxy primer after cleaning the reinforcement including thecost of removing of rust from barsincluding the cost of anti corosive paint as per technical specification on exposed reinforcement as well as newly provided reinforcement and mesh. The rate shall include all material, labour, plant and machinery, tools and tackles, preparation of surface as per technical specification, for all leads and lifts- complete. Approved Brands: BASF / Fosroc /Huntsman / Sika Cleaning reinforcement of total rust by tapping and using mechanical wire brush or any other suitable way to give it a totally rust free finished steel surface (Mode of measurement - chipping surface area with exposed reinforcement) |
| 175 | Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm up to 200mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-In- Charge. |
| 176 | a) Up to and including 12mm dia. |
| 177 | Providing & fixing shear connectors of 12mm dia steel up to 150mm length with sika Anchor Fix -3+ / Mungo/ Fisher Fisv 390/ Hilti RE -500 Epoxy resin RCC members including power drilling, cleaning of holes, insertion of epoxy, placing shear connector in position to ensure the bond as per manufactire recommendation complete as per site requirment and direction of Engineer or Architect. |
| 178 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC by mixing high dispersion SBR latex like Master Emco SBR 2 of BASF with white cement in the ratio of 2:3, The mixing should be done to lump free consistency for the bond coat and the screed/mortar should be applied once the bond coat is tacky.Master Emco SBR2 of BASF or Nittobond SBR-2 (Latex) of Fosroc or Equivalent. |
| 179 | (a) Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make |
| 180 | Cleaning of exposed concrete surface of sticking material including loose and foreign material by sand blasting with coarse sand followed by and including cleaning with oil free air blast as per direction of Engineer in charge. |
| 181 | Making of hole size of 152 mm diameter upto a depth of required depth withelectrical diamond corecuttingmachineinPCC / RCCbeams, slabs, floors etc. (1.0M c/c) wherever required at locations instructed by engineer-in-charge, taking out the cut core including all labours, tools and tackles complete including making hole in the slab / flooring to facilitate fixing of the frame of core cutting machine as per the site condition, marking the levels, makingand placing wooden templates etc. if required including removal of of anchor bolt after coring as per required. |
| 182 | Micro Concreting:Providing and laying ready to use non shrink. Cementious free flow micro concrete for the structural members e.g. columns, pillars, piers, beams slab Jacketting etc. of compressive strength >= 50 Mpa ( 28 days) according to ASTM C 109 of approved make and manufacture complete as per direction of Engineer- in - charge for replacing the carbonate part of concrete and repairingthe damaged surface of concete after fix the form work across the profile of damaged structural element or area. Pour the free flow non shrink Cementious free flow micro concrete mix in the form work. Cast-in-situ or any other suitable technique may be used to apply the concreteat all floor and all height including the cost of making holes in existing RCC slab @1.0mm c/c, if required, for pouring concrete in shuttering mould of jackett, centering, shuttering & including the cost ofsmooth surface finishing . Make: Renderock RG of Fosroc/ SikaRep Microcrete - 4 of Sika.Note:- Providing and erecting steel props (braced at centre and supported a continuous 2\"x3\"wooden runner, double height scaffolding system, resting on wedge and block minimum capacity 3 Ton) to support the structure provisionally during repair and jacketing etc. and maintaining them in position till required as directed by the Engineer-in-charge. ( no payment will be paid for props double height scaffolding system etc work). Make : Sikka, Dr. Fixitit, Fosroc as pproved by EIC/Architect) |
| 183 | (a) Micro Concreting Thick up to 100mm |
| 184 | Providing and laying of light weight foam concrete in sunken area of maximum density 800kg/cum including pumping of concrete to site of laying all lead & lift all height as per direction Engineer-in-Charge of approved mae:- |
| 185 | Providing and erecting steel props (braced at centre and supported a continuous 2\"x3\"wooden runner, resting on wedge and block minimum capacity 3 Ton) to support the existing structure provisionally during Retrofitting, repair & jacketing period/ duration etc. and maintaining them in position till required as directed by the Engineer-in-charge. |
| 186 | (a) upto 4.50 M height |
| 187 | Centering, shuttering & scaffolding where ever required for structural strengthening &protection work with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, up toheight of 9.0 m,will be remain till the strengthening work completed) |
| 188 | (a) Suspended floors, roofs, landing, floor, beams and balconies (single Plan area of double height of Auditorium to be measured of any height ). |
| 189 | Rebarring Connection System The work includes following:(i) Making hole for rebar in concrete / masonry surface of required dia and depth as required at site by using HILTI or any other equivalent make drilling tools.(ii) The holes should be blown out using compressed, oil free air. Extension tubes and air nozzles directing the air to the hole walls should be used, if holes are deeper more than 250mm with special designed BOSCH or any other equivalent Blower. Deeper holes more than 250mm should as well be brushed by machine brushing using steel brushes and brush extensions(iii) Insert chemical compound HY150 / Hilti RE- 500, HY 200 / Hilti RE-500, Re-100, or equivalent with special designed guns.(iv) Placing of the rebars should be inserted into the hole with a slight rotary motion after injecting the rebarring chemicals. Rate shall include all charges for above operations including double height scaffolding system , packers and preparation of surface, cost of necessary chemical / foil as per manufactures specification and necessary tools and equipments including removal of debris from the site all complete as directed by Engineer-in-Charge.Make:- Hiliti, Bosch, Fischer. |
| 190 | a) 12 mm dia rebar with 14 mm dia 75mm deep hole |
| 191 | b) 16 mm dia rebar with 17.5 mm dia 1000mm deep hole |
| 192 | c) 20 mm dia rebar with 24 mm dia hole |
| 193 | 12 to 18mm cement plaster of Mix: |
| 194 | a) 1:1:2(1 cement:1 sand:2 fine sand) |
| 195 | Providing & supplying the one component, polymer midified cementitious Anti-corrosive primer ( having the techanical parameters mentioned in material specifcations) formulated t pe dual protection of a polymeric barrier and an integral corrosion-inhibting system, to the existing steel & additional steel provided before patching of damaged areas, using suitable tools and equipment inclusive of Material, Manpower and Equipment. BASF Master Emaco P 130/fosroc Nitoprime Zincrich / sika Rustoff 100 or other equivalent. |
| 196 | Waterproofing. |
| 197 | Providing and laying water proofing treatment on roofs of slabs by applying water proofing compound consisting of applying: a) after surface preparation, first layer of slurry of Dr. Fixit Fastflax @ 0.06 sqm / kg. b) laying second layer of Fibre glass cloth. Overlaps of joints of fibre cloth should not be less than 10 cm as per direction Engineer - In - Incharge. |
| 198 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm. of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls up to 300mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls up to 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. |
| 199 | d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : (NOTE:- only terrace floor area will be measured for this item) |
| 200 | With average thickness of 120mm and minimum thickness at khurra as 65 mm. |
| 201 | Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of : i) Ist course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per sqm of area. iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm.) |
| 202 | Electrical Works |
| 203 | ELECTRICAL & GENERAL ILLUMINATION SYSTEM |
| 204 | PointWiring |
| 205 | Point wiring rates are inclusive of 2.5 sq mm FRLS PVC insulated stranded copper conductor FRLS wires for submain circuit and 1.5 sq mm insulated looping and earth wire. All wire should be FRLS |
| 206 | (a) Wiring for light point /call bell point with 1.5 Sq.mm FRLS PVC insultated copper conductor multistrand wire in surface/recessed PVC conduit,with modular switch, modular plate, suitable size GI box and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor multistand copper wire etc. as required. Wire Make: -Havells ,KK kable, Polycab, Finolex. Conduit Make:- Supreme, Prakash, Setia, Switch. Make:- Anchor Roma, North West, Norsis. |
| 207 | Loop Point Wiring for light point /fan point/exhaust fan point/call bell point with 1.5 Sq.mm FRLS PVC insultated copper conductor multistrand wire in surface/recessed PVC conduit,and earthing the point with 1.5 sq.mm.FRLS PVC insulated copper conductor multistand copper wire etc. as required.Wire Make: Havells ,K K kable, Polycab, Finolex. Conduit Make:- Supreme, Prakash, Setia.Make:- Anchor Roma, North West, Norsis. |
| 208 | Wiring for Ceiling fan points with 1.5 Sq.mm FRLS PVC insulated copper conductor wires in concealed P.V.C.conduits in ceiling / walls as directed including providing Hexagonal fan Box, and electronic fan regulator 5 A switch, 5 sided G.I. Boxes for housing the regulator, switch and earthing complete as required. Wire Make: Havells, K K Kable, Polycab, Finolex. |
| 209 | Wiring for exhaust Fan/ wall Fan points with 2.5 sq.mm FRLS PVC insulated stranded copper conductor wires in concealed P.V.C.conduits in False Ceiling/ Wall / Ceiling as directed including providing 6 amps flush type switches 6 amps 3 pin socket near exhaust fan/wall fan, 5 sided G.I. boxes for housing switches and 6 amps 3 pin socket outlet and earthing and complete as required. wire Make: Havells, K K Kable, Polycab, Finolex. Conduit Make:- Supreme, Prakash, Setia,Make:- Anchor Roma, North West, Norsis. |
| 210 | Wiring for 16 amps power outlet points with 4 sq.mm FRLS PVC insulated stranded copper conductor wires in concealed/recessed P.V.C.conduit as directed including providing 16 amps flush type switch and 6 pin socket with cover plate 5 sided G.I. outlet boxes for switches and socket and earthing the third pin with 4.0sq mm PVC stranded copper wire complete as required (Only one outlet shall be connected on each circuit)Wire Wire Make: Havells ,K K kable, Polycab, Finolex.Conduit Make:- Supreme, Prakash, Setia. switch Make:- Anchor Roma, North West, Norsis. |
| 211 | Wiring for 5 amps light plug outlets with 1.5 sq.mm FRLS PVC insulated stranded copper conductor wires in P.V.C.Conduits in ceiling/walls/floor as directed including providing 6 amps flush type 5 pin socket and 6 amps switch with cover plate, 5 sided G.I boxes for housing switches, sockets and earthing complete as required. (for general areas) Wire Make: Havells, K K Kable, Polycab, Finolex. Conduit Make:- Supreme, Prakash, Setia. switch Make:- Anchor Roma, North West, Norsis. |
| 212 | Wiring for 5 amps light plug outlets with 2.5 sq.mm FRLS PVC insulated stranded copper conductor wires with earth wire inP.V.C.Conduits in ceiling/walls/floor as directed including providing 2nos. 6 amps flush type 5 pin socket and 1no. 6 amps switch with cover plate, 5 sided G.I boxes for housing switches, sockets and earthing complete as required.Make: Havells, K K Kable, Polycab, Finolex .Conduit Make:- Supreme, Prakash, Setia. Switch Make:- Anchor Roma, North West, Legrand. |
| 213 | Conduiting and wiring for Tele, Computer & T.V. system. |
| 214 | Providing and fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.Conduit Make:- Supreme, Prakash, Setia. |
| 215 | (a) 25 mm |
| 216 | (b) 32 mm |
| 217 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductorwire in surface/recessed PVC conduit as required as directed by EIC of College. Wire Make: Havells ,k k kable, Polycab, Finolex. |
| 218 | a) 2 x 2.5 sq.mm + 1 x 2.5 sq. mm earth wire |
| 219 | a) 2 x 2.5 sq.mm + 1 x 2.5 sq. mm earth wire |
| 220 | Providing and fixing in position suitable 1.6 mm thick G.I. outlet box with 2 Nos RJ - 45 for Data/ voiceoutlet including crimplingwith all fixing accessories as required. |
| 221 | Supply and Laying including numbering / ferruling of wire (8 digit) and the continuity test for each cableofCat 6 - Telephone / Data cable in existing G. I. Channel / conduit. |
| 222 | Supply and fixing of 1.6 mm thick G.I Box along with RG 11 TV Co axial socket with Cover Plate for TV Outlets |
| 223 | Supply drawing connecting testing and commissioning of TV Coaxial cable RG 59 in existing conduit for CCTV System |
| 224 | Supplying and fixing of lighting fixtures |
| 225 | Supplying, installation testing & commissioning of following Lighting fixtures complete. (Make :- Philips, Bajaj, Usha, Wipro, Ankur, siska as per approved material list) |
| 226 | (a) Round Surface light/recesseLed Light 22 watts including all fixture as per approved material list |
| 227 | (b) 4\" long LED surface tube Light as per approved material list |
| 228 | (c) Ceiling Fan (1400 mm ) dia 1400 RPMBLDCwithstep Regulator switch as per approved material list |
| 229 | (d) Exhaust Fan (300 mm ) Heavy Dutywith G.I. Louvers as per approved material list |
| 230 | (e) Extra over Item No. (c) for providing 900 mm hanging rod in place of 300 mm hanging rod as per approved material list |
| 231 | (f) Extra over for providing 900 mm hanging rod arrangement for Light Fixtures. as per approved material list |
| 232 | (g) Mirror Light 11W complete fixing and providing as per approved material list. |
| 233 | (h) 2\"x2\" square LED Light 20 watt (Conceal or surface mounted) as per approved material list |
| 234 | Earthing |
| 235 | Providing and fixing in position the following copper strips and wires including providing all fixing accessories and effecting proper connections |
| 236 | (a) Copper Flat 50 mm x5 mm |
| 237 | (b) GI Flat 50 mm x 5 mm |
| 238 | (c) GI Flat 25mm x 5 mm |
| 239 | (d) Copper Flat 25mm x 5 mm |
| 240 | (e) GI Wire 8 SWG |
| 241 | Providing, laying, testing and commissioning of 600 x 600 x 6.3 mm thick GI electrode, with 2 no. 50 X 5 mm GI strips from earth electrode to inspection chamber, 50 mm dia medium class GI pipe, CI funnel with 20 gauge GI wire mesh, masonry chamber 450 x 450 mm with 3 concrete base CI / Heavy duty chequered plate manhole cover with frame painted with bitumastic paint and packing with mixtures of charcoal and common salt around plate electrode including digging of pit upto permanent moisture level but not less than 3 meter. |
| 242 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 243 | Distribution boards |
| 244 | Light & Power Distribution Board |
| 245 | (a) Supply and installation of sheet metal enclosed double door 12 Way TPN DB, each phase consisting of 12 Nos. 10/20 AMP SP MCB’s and controlled by one number 63 Amps DP MCB. ELCB on each phase. Make:- Hager, Legrand,L& T |
| 246 | Cables, pipe & cable tray |
| 247 | Supplying and laying of the following sizes of 1100 Volts grade PVC insulated copper conductor wires in Suitable Size of MS conduit including and termination for DB Sub mainMake: Havells, K K kable, Polycab, Finolex. |
| 248 | (b) 4 x 10 + 2 x 6 sq. mmPVC insulated stranded copperconductor wires |
| 249 | (c) 4 x 16 mm + 2x 6 PVC insulated stranded copperconductor wires |
| 250 | (d) 4 x 25 + 2 x 6 sq. mm PVC insulated stranded copperconductor wires |
| 251 | Supply & installation of underfloor raceways of powder coated CRCA Mild Steel with cover of following sizes inclusive of cutting, chasing & refinish with cement plaster in PCC/IPS flooring |
| 252 | (a) 100 mm x 38 mm x 2 mm thick |
| 253 | (b) 50 mm x 38 mm x 2 mm thick |
| 254 | Supply & Installation under-floor junction boxes fabricated from 14 gauge CRCA Mild steel, duly epoxy painted / powder coated after 7 tank processes, with screwed recessedtop covers, screwed plates on four sides, of the following sizes, as per specifications. |
| 255 | (a) 200 mm x 200 mm x 40 mm |
| 256 | (b) 150 mm x 150 mm x 40 mm |
| 257 | Design manufacture , supply and fixing in position the cable trays of the following sizes for supporting 1.1 KV grade armoured/unarmoured aluminium /copper conductor cables. Fabricate the cable trays from perforated 1.6/2mm thick M.S. CRCA sheet duly galvanised with expansion coupler plates duly galvanised,with bolts, washer and nuts. Knock out holes for cable connections as per approved design. The tray should comply with the specification of NEC (National Electric Codes) and NEMA (National Electric Manufacturers Association). The steel should be as per IS:226 and galvanising as per IS :2629/BS 729/ASTM 123.The rate shall also include for supporting steel , fish plates , fixing accessories , nuts bolts, supporting down rods,dash fastener, cutting the RCC etc. complete as required. |
| 258 | (a) 150 mm wide x 40 mm x 2.0 mm thick |
| 259 | (b) 300 mm wide x 40 mm x 2.0 mm thick |
| 260 | VRV Air conditioning Works. |
| 261 | VARIABLE REFRIGERANT VOLUME SYSTEM |
| 262 | OUTDOOR UNITS- HEAT PUMPS |
| 263 | Supply of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.2 and IEER not less than 7.9 |
| 264 | The ODU shall have lownoisecondenserfans with extrenal static pressure of the outdoor unit shall be more then75Patoavoidhotairrecirculation,auto addresssetting,autocheckfunctionfor connection error and complete with indoor and outdoor unitswith individual controller and withfittingsetc.The compressor and VRV/VRF Outdoor make should be same. For enhanced energy savings the COP of each refrigerant circuitsystemmentionedbelowshallbe7.50 minimum at 50% load, at AHRI Condition in cooling mode.The unit shall also have feature to automaticallymodulatetheevaporative temperature between 6 deg C to 11 deg C with respecttoloadforbettercomfortandenergy efficiency. (Unit shall deliver atleast 87% of mentioned nominal capacity @ 52 Deg C). The Unit should have free phase technology so that unit can work in case of phase reversal also without tripping of units. |
| 265 | Make: Daikin, Mitsuibishi, General |
| 266 | Outdoor Units - Heating & cooling both |
| 267 | ODU - 24HP Heat Pump VRV ALPHA Series RXYQ24BRY16 |
| 268 | DGT Joints |
| 269 | Supply ofvariable refrigerant volume modular slim type indoor units comprising of EEV & all accessories as per the specifications. The indoor units shallbe suitabletowork on cooling as well as heating mode. The indoor units shallbesuitableforoperationon 220 ±6%volts, 50Hz, 1 phaseAC power supply. |
| 270 | 1.5 TR FXAQ50ARVE6 HI-WALL UNITS |
| 271 | 2.0 TR FXAQ63ARVE6 HI-WALL UNITS |
| 272 | SITC ofcorded/wire remote e controller for Hi-wall alongwith fixing on the wall wih wooden box enclser fwith locking arragement. |
| 273 | SITC Refrigerant Headers/Refnutfor Indoor units |
| 274 | Supplying ofmastercordless remote controller for Hi-wall along with IR Receiver |
| 275 | Inverter based VRVSystem |
| 276 | Installation, testing and commissioning of following indoor and outdoor units, fittings remote controls |
| 277 | Outdoor Units |
| 278 | ODU - 24HP Heat Pump VRV ALPHA |
| 279 | Installation Installation, testing and commissioning of VRV INDOOR Units |
| 280 | Hi-Wall Units |
| 281 | Refrigerant Piping for VRV system |
| 282 | Providing and fixing in position of Interconnectingrefrigerantpipe work with (13 mm thick) closed cell elastomeric nitrile rubber tubular insulation betweeneach set of indoor & outdoor units as perspecifications, all pipinginsidethe buildingshallbe properlysupported with MS hanger |
| 283 | 6.3 mm with 13 mm Insulation |
| 284 | 9.5 mm with 13 mm Insulation |
| 285 | 12.7 mm with 13 mm Insulation |
| 286 | 15.8 mm with 13 mm Insulation |
| 287 | 19.1 mm with 13 mm Insulation |
| 288 | 22.2 mm with 13 mm Insulation |
| 289 | 28.6 mm with 13 mm Insulation |
| 290 | Transmission cable |
| 291 | Supply, Installation, testing and commissioning of communication cable of size 2C x 1.5 sqmm in pvc conduit between indoor & outdoor units & Corded remote wire for indoor units |
| 292 | Providing and fixing in position the following heavy duty UPVC pipes for condensate drain cut to required lengths and installed in position the necessary elbows, tees & reducers. |
| 293 | 25 mm dia |
| 294 | 32 mm dia |
| 295 | 40 mm dia |
| 296 | MS outdoor frames |
| 297 | Providing and fixing of heavy duty MS channel stand for outdoor units with 2 coats of primer & paint |
| 298 | Installation and gas charging - first charge refrigerant (R-410A or equivalent) with lubricating oil including extra top up for VRV system. |
| 299 | Charges for Loading, unloading & shiftting of all outdoor units to Terrace. |
| 300 | Electrical Panel |
| 301 | Supply & fixing, testing & commissioning of double door, outdoor type IP-54 floor mounted electrical distribution panel made of 2mm thick CRCA sheet 3mm thick gland plate, with 400A aluminium busbar duly power coated complete with PCC foundation & MS angle base frame (150 mm above ground & 150 mm below ground) voltmeter ammeters, indicating lamps, selector switches, etc as reqd. comprising of the following.(Panel shall be CPRI approved) |
| 302 | INCOMING |
| 303 | 125A 4P Adjustable MCCB 25 kA, 415 volts, 50Hz, with door interlocking with all connected accessories |
| 304 | 1 no. 0-500 Amp. Ammeter with selector switch. |
| 305 | 1 no. Volt meter with selector switch |
| 306 | 0-500volts.3 nos. RYB Led indication lamps. |
| 307 | OUTGOING |
| 308 | 63A 4P Adjustable MCCB 4 Nos |
| 309 | 63A 4P MCB - 3 nos. for indoor units D.B |
| 310 | Supply & fixing, testing & commissioning of Distribution box for Indoor units with 4Pole 3 phase 63A incoming MCB & 12 nos. 16 Amp single phase MCB in each distribution box |
| 311 | Supply, Installation, TestingandCommissioning of isolator box with three pole 63Amp MCB near each ODU unit |
| 312 | Supply of XLPE insulated Copper conductor, 1.1 KV grade cable of following size complete as required. |
| 313 | 4C x 16 Sq mm, Copper Armoured power cable for outdoor units from isolator box to outdoor unit |
| 314 | 3C x 2.5sqmm, Copper Flexible for IDUs |
| 315 | 4C x 50 sqmm Aluminium armoured cable from Main electrical panel to isolator/MCB box near Outdoor unit |
| 316 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 317 | 4 X 16 sq. mm (25mm) |
| 318 | 4 X 50 sq. mm (57mm) |
| 319 | Providing and fixing GI perforated cable tray with cover for copper piping near outdoor units & cable tray without cover for indoor units where the copper pipe will run in open area |
| 320 | 300mm x 70mm x 1.6mm thick with cover for outdoor units |
| 321 | 200mm x 70mm x 1.6mm thick without cover for indoor units |
| 322 | Providing and fixing 8 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 323 | Isolator with weather proof box |
| 324 | (a) 63A |
| 325 | (b) 32A |
| 326 | Shifting & Liftingof existing VRV air-conditioning out door unit of capacity 16 HP eachwith its Electrical panel &M.S. Stand from Second floor roof to proposed Third floor roof Including the cost of additional copper piping requied withrequired copper armed wire, gas filling, vacumming an commissioning with necessary repair work required like pcb, panel, ciruit, etc required after shifting. (Note:- Contractor should visit the site before quoting). |
| 327 | SITC Isolator Switches With Metal Enclosure For Outdoor Units |
| 328 | (a) 40 A TPN isolator switch for equipments with sheet metal enclosure, rain protection etc. as required to suit the site condition. (Enclosure shall be suitable for out door installation.) |
| 329 | (b) 32 A TPN isolator switch for equipments with sheet metal enclosure, rain protection etc. as required to suit the site condition. (Enclosure shall be suitable for out door installation.) |
| 330 | Additional works in Main panel. |
| 331 | (a) Out Going |
| 332 | (a-1) SITC 1 No. 400 A TPN MCCB (35 kA) suitable to receive 3.5C x 185 sq mm AYFY Cable .(Note:- Including disconnecting the existing & coneecting the new cable). |
| 333 | CCTV Works. |
| 334 | SITC CP PLUS 4MP Full HD IP Network Dome camera:Image Sensor: 4 MP CMOS, Max. outputs 4MP(2688×1520)@50fps/60fps, Instastream/H.265/Smart H.264+/H.264 coding,3.6mm fixed lens, Day/Night Mode: Auto/Color/BW (Black and White), Operating Condition: -40° C to 60° C (-40° F to 140° F), Humidity 90% or less (no condensation), Power Supply: 12 VDC ± 25% or PoE .Make:- CP Plus, Bosch, Hikvision, Dahua, D-link. |
| 335 | SITC CP PLUS 4MP Full HD IP Network Bullet camera: Image Sensor: 4 MP CMOS, Max. outputs 4MP(2688×1520)@50fps/60fps, Instastream/H.265/Smart H.264+/H.264 coding,3.6mm fixed lens, Day/Night Mode: Auto/Color/BW (Black and White), Operating Condition: -40° C to 60° C (-40° F to 140° F), Humidity 90% or less (no condensation), Power Supply: 12 VDC ± 25% or PoE .Make:-CP Plus, Bosch, Hikvision, Dahua, D-link. |
| 336 | SITC Hikvision 32 Channel NVR:Up to 32-ch IP camera inputs, H.265+/H.265/H.264+/H.264 video formats, 1 HDMI and 1 VGA interfaces, both interfaces support independent video output, 1 HDMI and 1 VGA interfaces, both interfaces support independent video output, 2SATA port. Make:- CP Plus, Bosch, Hikvision, Dahua, D-link. |
| 337 | SITC Hard Disk 6 TB Seagate. Make:-Skyhawk / WD Purple |
| 338 | SITC PoE switch CP PLUS / DLINK 8+2. Make:-Gigabit |
| 339 | SITC PoE switch CP PLUS / DLINK 16+2 Make:-Gigabit |
| 340 | SITC Gigabit Ethernet Switch 8 port 10/100/1000 Mbps Dlink |
| 341 | SITC Wire Cat6 Dlink Unarmored (100% copper) |
| 342 | SITC Connectors Video & Power with CCTV junction box |
| 343 | SITC Network Enclosure Rack with PDU & Fan for PoE switch & NVR |
| 344 | Laying of Data/camera cable in PVC conduit (inlcuding the cost of PVC pipe) of required dia.Pipe as approved by EIC. |
| 345 | Accessories:- Consumable accessories LIKE Cable tie, tape, screws, nails, fastners, steel wire etc. required in complete camera work installation . |
| 346 | SITC HDMI Extension & USB extension for display at Principal room |
| 347 | Providing and fixing of following sizes of PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 25mm Conduit Make:- Supreme, Prakash, Setia, AKG, Polypack. |
| 348 | Supply, Drawing, Connecting, Testing and Commissioningwith laying of TV Co-axial cable RG 59 in conduit for CCTV System. Including the cost of connection with main controller of college. |
| 349 | FIRE FIGHTING SYSTEM. |
| 350 | Providing, laying, testing & commissioning of \"C\" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : |
| 351 | a) 80 mm dia |
| 352 | b) 100 mm dia |
| 353 | Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : |
| 354 | b) 100 mm dia |
| 355 | Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : |
| 356 | a) 80 mm dia |
| 357 | b) 100 mm dia |
| 358 | c) 150mm dia |
| 359 | Supplying and fixing First Aid Hose Reel, wall mounting swinging type completewith drum & bracket of MS construction, spray painted in Post office Red, confirming to IS : 884/1995 with upto date ammendments, complete with the following as required. |
| 360 | Furniture. |
| 361 | Providing & laying Student Desk of Width 1800mm ( 6\"0\") having Top (1800mm x350 mm), Seat (1800mm x 300mm), Back (1800mm x 230mm) & Book Shelf ( 1800mm x 250mm) in 22mm thick Teak wood and 14 gauge M.S. frame of 35mm x 35mm square pipe. The design is approved by EIC/Architect.Make:- Rockworth, Godrej, Wipro, wesource. |
| 362 | Providing, making and fixing Tables for Delgates for Rooms ofSizes (600mm x 1800mm x 750mm) in 19 mm thick HDHMR Board and 150 mm high cable alley on table top for Data(3Nos.) & Electrical (6Nos.) with modoular switch- socket including box, Face plate, wire ( 2.5 sqmm & cat 6) with SITC . Make necessary cutouts for electrical and data cables wherever required. Provide groove patties, mouldings etc. as per drawings. The teak wood mouldings and lippings on edges to be finished in melamine polish as per instructions. The tabletop, sides and the front portions, inner sides of the table is to be finished with 1 mm thick laminate of approved shade and quality. |
| 363 | Rooms Chair: Providing & Supplying ergonomically comfortable and aesthetically designed medium back chair. The back is made of Polypropylene and upholstered with breathable fabric tapestry. The seat is made of 12mm thick wooden ply & PU foam density 40+/-2 kg/m3 upholster with fabric tapestry. Seat and back joint by HRC sheet cover with PP below. Armrests are made of polypropylene and cantilever shape frame is made of CRCA metal pipe dia. 28.5mm x 2mm thick duly epoxy powder coated with 40-50 micron thickness. Seat Size depth-18\" width-19\" and back height -17\". Overall height 35\". Whole CRCA metal frame quality to meet desired strength and rigidity. Make:- Rockworth, Space wood, Godrej, HNI, Wipro, wesource. |
| 364 | Providing making and fixing Teacher table of 1200mm (L) x 750mm (D) x 750mm (H), in 18 mm thick HDHRM Board.The table top, sides and the front portions, inner sides of the table and drawers is to be finished with 1 mm thick laminate of approved shade and quality. Provide 1no. drawer and storage with shelves with front openble shutter at under table cupboards as per design. The drawer will have bottom of 6 mm and sides of 12 mm HDHRM board & Drawer run on S.S. sliding channe of approved make. Table top should have necessary cutouts for electrical and data cables wherever required. Provide groove, lipping, mouldings etc. as per drawings. The teak wood mouldings and lippings on edges to be finished in melamine polish as per instructions. Provide & fixing of necessary hardware like SS.hinges, magnetic ball catcher, s.s. sliding Channel, S.S.handles & 3 nos. locks. |
| 365 | Over Head Wall Storage: |
| 366 | Providing & fixing over Head Wall Storage cabinets in position as per drawing enclosed. The cabinets shall be 16” deep and out of 18 mm HDHMR board. The back and the shutters shall be made out of 18 mm HDHRM board respectively. Shelves to be provided as per requirements inside as per design/approval. All the external and internal surfaces including the edges shall be finished with 1 mm thick laminate. One Open shelves of 8\" wide along the length of storage is to be also provided under the over head storageAll the necessary fittings like SS hinges, magnetic ball catcher, locking arrangement, ss handles tower bolts etc. are to be provided and are to be provided as per direction of Engineer-in-Charge / Architect. (Front area is measured for payment) |
| 367 | High Wall Storage: |
| 368 | Providing & fixing High Wall storage Cabinets in position as per drawing enclosed. The cabinets shall be 22” deep and out of 19 mm HDHRM board. The back and the shutters shall be made out of 18 mm HDHRM board respectively. 18 mm thk HDHMR board Shelves to be provided as per requirements inside as per design. All the external and internal surfaces including the edges shall be finished with 1 mm thick laminate. All the necessary fittings like SS hinges, magnetic ball catcher, locking arrangement, ss handles ( 4\"),tower bolts etc. are to be provided and are to be provided as per direction of Engineer-in-Charge / Architect. |
| 369 | Providing making and fixing of shelves / partitions. All the shelves / partitions to made out of 19 mm HDHRM board with external surface including the edges laminated with of approved shade of 1 mm thick laminate as per direction of Engineer-in-Charge / Architect. |
| 370 | Providing making and fixing table of following sizes in 18 mm thick HDHMR Board as per drawing enclosed. Provide drawers and storage cupboards as per design under the table; provide a centrally placed keyboard drawer wherever required below the main tabletop. All the drawers to have bottom of 6 mm and sides of 12 mm HDHRM board. Make necessary cutouts for electrical and data cables wherever required. Provide groove patties, mouldings etc. as per drawings. The teak wood mouldings and lippings on edges to be finished in melamine polish as per instructions. The tabletop, sides and the front portions, inner sides of the table and drawers is to be finished with 1 mm thick laminate of approved shade and quality. All the drawers to have bottom of 6 mm and sides of 12 mm HDHMR board and are to be provided with channels and locks as specified. Provide the necessary hardware like hinges, magnetic ball catcher handles. |
| 371 | a) Computer work stations600 mm wide 750mm high with space for CPU and 150 mm high cable alley on table top |
| 372 | Providing & fixing Center Table of Six 1200mm (L)X 2400 mm(W) X 750mm (H) , in 18mm thick HDHRM Board. The table top, side and Frame of center table is made up of 18 mm thick HDHRM board finished with 1 mm thick laminate. All edges is finhed with teak wood leaping or 2mm thick edge moulding as directed by EIC of College.SS. Fitting Make:- JINDAL, OZONE, DORMAHDHRMBoard Make:- ACTION tesa, Century, Greenply. Laminate Make:-Merino, Greenlam, Century & Durian. |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail