}

Tender For Additional / Alternator To P-266 Of 5 Afdc And Provision Of Misc E/M And B/R Services In Various Buildings And Certain Minor Works At Afs Pune Under Ge Af Lohegaon., Pune-Maharashtra

Tender Notice

52282590
Tender For Additional / Alternator To P-266 Of 5 Afdc And Provision Of Misc E/M And B/R Services In Various Buildings And Certain Minor Works At Afs Pune Under Ge Af Lohegaon.
Tender
Indian
Maharashtra
Pune
01-12-2025

Tender Details

Tender For Additional / Alternator To P-266 Of 5 Afdc And Provision Of Misc E/M And B/R Services In Various Buildings And Certain Minor Works At Afs Pune Under Ge Af Lohegaon.; 1 Dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roof covering all as specified and directed. 2 Dismantling timber in fillets rails, posts, rafters, purlins etc over 40 Sqcm in section in unframed work 3 S&F pre painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. 4 S&F pre painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall/Eaves boards, fixed with self tapping screws as specified 5 S & F Rolled Mild Steelroof trusses(framed),trussed ,purlins ,rails and fastenings etc.,confirming to Fe 410 - S including distance pieces, cleats, etc., complete. 6 S & F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering.doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening andfixing complete (Eaves board fixing ) 7 S & F 6mm thick asbestos cement plain building boards fixed to steel frameowrk with screws all as specified and directed ( For Eaves Board). 8 S &F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe 410-w (Gde E-250 quality A) all as specified and directed. 9 M & L for Preparation of newsteel/iron surfaces of any description having width/girth exceeding 10cm and applying two coat of synthetic enamel paintover red oxide primer for material and labour complete all as specified. 10 M & LPCC B1 1:2:4 (12.5mm graded aggregate) for in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed. (Note :- Bed boxes and Coping on wall to fill up the gap) 11 Demolition of Brickwork or stone/boulder masonry/PCC bloack masanory,built in cement motar all as specified and directed. 12 S & F brick work with fly ash bricks,straight or cuved on plan exc 6m mean radius built in CM 1:4all as specified and directed. (Note : 1. For filling the Gap between sheet and wall 2. Clsoing of ventilaots ) 13 Dismantling of Wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified and directed by Engr-in-charge 14 Material and labour for suspended false ceiling usinganodized aluminum snap grid frame work.Including Hanger 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G I flat 40x3mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long complete. Perforated particle board/tiles for insulation and acoustic purposes, 60 x 60 cm size, fixed on snap grid 12mm thick confirming to IS 2095, 2995 Part I fixed with 25mm dry wall screws @ 230 mm C/C with screw driver to match surface attachment. Finally board have to be joined and finished to have a flush look using jointing compound/tape as per manufacturer instruction. With Designing as per direction in two steps complete all as specified and directed by Engineer in Charge. 15 M & L rendering 20mm thick on surface of stone masonary surface in CM 1:4and is to be finished even and smooth with out using extra cement complete all asspecified directed 16 M & L rendering 20mm thick on surface of stone masonary surface in CM 1:6and is to be finished even and smooth with out using extra cement complete all asspecified directed 17 M&L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than than 50gm/litre and UV resistance as per IS 15489:2004 Alkali and fungal resistance, dirt resistance exterior paint or required shade with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @0.9 litre/10 sqm over new surfaces/old surfaces of wall all as specified and directed. 18 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cmdeep and getting out hard dense soil 19 Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting poin 20 Hard coare of broken stone aggregate, of gauge n.exc 60 mm 21 M&L for cement concrete Type D -2 1:4:8 (40 mm graded agg) in foundation fillig/path and mass concrete 22 Formwork to sides of flat concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter 23 M&L Forming Contraction (Dummy) joints 30 mm deep x 10mm wide for plinth protection & similar work , filled with sealing compound Grade A in plinth protection 24 Providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh (Fillets, metal frame work and G.I. wire mesh paid separately) 25 S &F 605 x 605 mm Anodised aluminium snap grid frame work for false ceiling all as specified 26 Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm longand expansion hold fasteners12.5mm dia. 40mm long complete all as specified 27 Dismantling boarding, any description, fixed in any position with nail 28 Taking down cement plaster on brick/stone/concrete surface including wall tiling and hacking out joints hacking for key scrubbing down with water etc complete 29 M&L rendering 15mm thick on surface of concrete surface in CM 1:6and is to be finished even and smooth with out using extra cement complete all asspecified directed 30 Demolition of stone / block masonry built in CM 1:4 31 M&L for precast solid cement concrete block masonry exc 10cm in width built with solid blocks Grade C1 (1:3:6 mix) and set in CM (1:6). 32 Preparing new wall surface, providing and applyingplaster of paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth and applying two coats of oil emulsion 33 Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners withholdfasts and brackets, complete 34 S&F Anodised aluminium powder coated frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified 35 S&F Sheet glass 5.5 mm thick ordinary quality and glazing fixedin aluminium doors squareexc 0.5 sq. m in each pane 36 S&F Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers 37 Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, 38 S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats 39 Demolition of cement concrete (un-reinforced) in ground floors and pavings not exc 15cm thickness (below or above ground level) 40 M & L for 100mm thick PCC type B-2 (1:2:4) using 40mm graded aggbnas in flooring finshed even and smooth w/o using extra cement. 41 M & L for 75mm thick PCC 1:3:6 type C-2 using 40mm graded agg finished even and smooth w/o using extr cement. 42 M & L for nonskid coloured ceramic tiles 7 to 8 mm thick (square/ rectamgular)area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors (Superior/ Premium quality), set and jointed in neat cement slurry and pointed in colour cement to match the shade of tile over and including 15mm thick screed bed in CM (1:6) complete all specified and directed. 43 Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed by Engineer in Charge. 44 M & L fire resistant paint on steel surface over a coat of primer complete alll as specified (Note: The primer is of same material of 1:1 dilution application) 45 S & F of mineral fibre reinforced false ceiling tiles (all height)of size 595X595 mm of approved texture, design and pattern. The tiles should have humidity risistance RH of 99%, Light resistance greater than 85% , thermal conductivity K=0.052-0.057 W/mK, Fire performnce As per (BS476 Pt-6&7) in true horizontallevel suspended on interlocking T-grid of hot dipped all around ganvanisedIron Section of 0.33mm thick (galvanised @ 120GSM)bcomprising of main T runner of 15 X32 mm of length 3000mm, cross T of size 15X32 mm of length 600mm to form grid module of size 600X600 mm suspended from ceiling using galvanised Mild steel item ( galvanised @ 80GSM) 50mm long 8mm outer dia M-6 Dash Fastner, 6mm diameter fully threaded hanger rod upto 1000mm length and L-shped level adjuster of size 85X25X2mm, spaced at 1200 mm center to center along main T, the system should rest on perpfery walls/ partition with the help of GI perimeter wall angle of size 24X24X300mm made of 0.40mm thick sheet, to be fixed to the wall with the help of the plastic rawl plug at 450mm center to center & 40mm long drywall S.S screws. The exposed bottom portion of all y- Sectionused in false ceiling support system shall be prepainted with polyster baked paints, for sll heigth. the work shall be carried outas per specification drawing adn as per the direction of the Engr-in-charge with 16mm thick Bevelled traingular Mineral Fibre faalse ceiling (NRC 0.5 to 0.6)) 46 Taking down and of chowkats or frames exc 1.5 sqm n exc 4 sqm each 47 S & F Anodised aluminium frame powder coated to (minimun thickness of powder coating 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. 48 S & F Anodised aluminium powder coated door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips,ruber neoprene packing, handk=les 2 Nos in each door, hinges, anodises aluminium snap beading screws etc. complete all as specified. 49 Cuting holes exc 150 sqcm but not exc 400 Sqcm into or through brick walls built in cement mortar of any description and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-I as required 50 m&L two coats or Oil Bound distemper on Cement concrete surface over a coat of primer as per the shed directed by the engineer-ncharge, complete all as specified. 51 M&L for treating small articles such as ends of posts, holdfasts etc with tar or coal tar black paint; area exc 0.1 Sqm but n exc 0.5 Sqm each 52 S&F sheet in repairs glass 4.8 mm thick exc 0.5 sqm area ordinary quality and glazing with oil putty/rubber gasket fittings all as specified and directed. 53 M & L in repairs for 12mm Prelaminated particle board, interior grade, prilaminated both side with decorative choice lamination fixed with screws to timber/Aluminium frame work complete all as specified and directed. 54 S&F Rotational moulded polyethlene water storage tanks (cylindrical vergical with closed top) 1000 Ltr capacity hoisted and fixed in position including removal of existing damaged water tanks all as specified in SSR Part I 55 S & F in repairs 20 mmBrass valves ,high pressure,with polythene float and flynut complete,screwed for iron pipe or brass ferrule and fixed 56 S&Fbib tap cast copper alloy chromium plated butterfly handle screwed down screwed for iron pipe completed (15mm dia tap). 57 S&F GI tubingof 15 mm dia medium grade with all fittings & fixed complete to walls and ceiling or laid in floors completeall as specified and as directed by the Engr-in-C. 58 S&F GI tubingof 20mm dia medium grade with all fittings & fixed complete to walls and ceiling or laid in floors completeall as specified and as directed by the Engr-in-C. 59 S&F GI tubingof 25mm dia medium grade with all fittings & fixed complete to walls and ceiling or laid in floors completeall as specified and as directed by the Engr-in-C. 60 S&F25 mm dia gun metal ,globe or gate valves , with iron wheel head , screwed both ends for iron pipe 61 S&F20 mm dia gun metal ,globe or gate valves , with iron wheel head , screwed both ends for iron pipe 62 Dismantling wrought iron or mild steel work of any description not otherwise provided for. 63 S & F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 graded St 240 all as specified and directed.(Eaves Baords) 64 M&L for Providing precast cement concrete (20mm graded stone aggregate) 1:3:6 type C-1 as in solid building blocks 10cm thick setting in cement mortar,1:4 complete, in walls all as specified. 65 Demolition of Brick/precast concrete block/Stone/boulder masonary walling built in cement mortar including all quoins, arches , pillars etc all as specified and as directed 66 M&L TMT bars 10 mm and over cut to length, bent to shape required incl cranking, bending spirally for hoping for columns hooking ends and bindind with ms wire (annealed) not less than 0.9mm dia quality confirming to all as specified 67 M&L form work to soffits of suspended slabs such as roof slab landings and similar works n exc 200mm thick (horizontal or slopping) fair finished surfaces of concrete flat all as specified 68 M&L for reinforced cement concrete M 20 using 20mm crushed stone aggregate as in roof slabs supported on walls surfaces of concrete flat all as specified. 69 M&L for rendering 10mm thick on fair faces of brick work or concrete surface in CM 1:6 and rendering is to be finish even and smooth with out using extra cement. 70 M&L for preperation of new concrete /plastered surface of any description, two coat of plastic emulsion paint over a coat of primer complete all as specified and as directed complete all as specified and as directed. 71 M&L for Powder Coated (Minimum thickness of powdercoating 50 micron)Anodised aluminium frame of standerd section for doors, windows, ventilators and partitions withdoublerebates including joining cleat for fixing etc. complete all as specified 72 S & F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge (For sliding window ) 73 M&L sheet glass 4.0mm thick figured glass, pin head type and glazing with aluminium beeds in square exc 0.50 sqm in each pane complete all as specified and as directed 74 M&L for vetrified ceramic tiles 10mm thick full body(Dark shade/Ultra Charged/Double charged ) (square/rectangular) polished, area of each tilesexc 1.00 sqm in floors over 15mm thick screed bed in CM 1:6 on floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade as specified and as directed. 75 M&L for vetrified ceramic tiles 10mm thick full body(lightshade ) (square/rectangular) polished, area of each tiles not exc 0.36 sqm in floors over 15mm thick screed bed in CM 1:6 on floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade as specified and as directed. 76 S&F for Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediatechannel at 457 mm centre to centre and including Hangers 6 mm dia. G.I. (upto1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I.flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified 77 S&F for 12mm thick Seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish(Frame work for ceiling shall be measured and paid separately) 78 Removal of existing Rifle racks including all fixing stell bolts and cement work all as specified work 79 M&L pre-cast cement concrete(20mm graded crushed stone aggregate) 1:3:6 type C-1 as in block masonery exc 10cm in width with solid block masonery with solid blocks,exc.10cm in width and setting in cement mortar 1:4 all as Specified 80 M&L for Providing precast cement concrete (20mm graded stone aggregate) 1:3:6 type C-1 as in solid building blocks 10cm thick setting in cement mortar,1:4 complete, in walls all as specified. 81 M & L for 25mm thick PCC 1:2:4,type B-0, (using 12.50 mm graded stone aggregate) as in under layer of tile flooring & finishing the surfacesrough to receive screed bed complete as specified and directed. 82 M&L for machine cut mirror polish kota stone slab flooring 20-25mm thick over 15mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including round nosing at corners ,rubbing and mirror polishing complete as specified and as directed. 83 M&L for machine cut mirror polish kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar over 10mm thick cement screed base in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including round nosing at corners ,rubbing and mirror polishing complete as specified and as directed. 84 Fixing and grouting of new steel Rifle racks on the floor including necessary fixing bolts and necessary arrangements of grouting and grouting material all as specified. 85 M&L Hand rails, grills ,Gates ,half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof ,Brackets for Valley gutters ,including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or FE 310-0 86 S&F for Mild steel ,plain black sheet of minimum 0.8mm thickness for Hoods cover for Rolling shutters;cladding to door shutters/Hangar doors ; water tank platforms etc with plain 40mm lap joints or welded/riveted seams including ,bending, turning up, mitred angles , stopped ends,outlets,etc. as required all as sprcified and directed by Engr-in Charge. 87 M&L for Cutting holes in brick/stone walls in mud/cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4Type B-1 as required all as specified and directed by Engineer-in-Charge. 88 Taking down the existing surface batten type point wiring of aluminium for Light, fan, Sockets, power sockets, stair case light pointcomplete with switch socket regulator , bracket fitting etc and making good disturbed surfaces for wall, floors etc as directed by Engr- in charge. including sorting out serviceable and unserviceable light fitting and keep serviceable fitting in safe guard for reuse as required on site. 89 Taking down the sub main wiring of any dia / sq mmon teak wood batten /PVC conduit GI earth wire all as directed. 90 Taking down cearfully byunscrewingthe unserviceable DB Boxes, MCB distribution boards SP & TPN with porcelain cutouts etc all as directed. 91 Material and labour for providing point wiring with two runs of 1.5 Sqmmmulti stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core multi stranded copper conductor FRLS PVC insulated 1100 Volts grade wire for continuous earthing complete in and including PVC casing and capingwith all fittings/fixture etc andsurface typePVC box, cover plate all as specified and directed by Engr-In-Charge.(a) Onelight point controlled by one switch. 92 (b) One 3 pin socket 5 A on independent board. 93 (c) One 3 pin socket 5 A on same board. 94 Material and labour for providing point wiring with two runs of 2.5 Sqmmmulti stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core copper stranded FRLS PVCinsulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping,with all fittings/fixture etc andsurface typeModular , PVC box cover plate, frame all as specified and ndirected by Engr-In-Charge. 95 S & F Sub Main Wiringwith FRLS PVC Insulatedmultistranded copper conductorwires ofsize2x6.0 sq. mm + 1x6.0 sq. mm earth wire in casing caping complete as directed.Note : for Item No 95 One run of phase wire one run of Neutral wire and one run of Earth wireand one run of casing and capping shall be meassured and as one length. 96 S&F sheet metal enclosure with socket plug top , single pole and neutral enclosure with two pin earth plug and socket complete with one MCB SP of capacity 20 Amps.including fixing concealed in wall and making good the disturbed surfacecomplete all as directed 97 Supply and fixing LED lights fitting 1x 22W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. 98 Supply and fixEnergy efficient recess mounted LED panel fitting 36 Watt suitable for 2x2 grid in white colour with high quality diffuser for uniform light & high Efficiency. Made from CRCA sheet, Pre-coated white color. Separate replaceable electronic driver, lumen constant of 5700/6500K colour temperature with current electronic connections as directed 99 S&F MCB SP 240 volt 6 to 32 A C series complete 100 S &F for MCB SPN 40-63 Amps C curve and electric connections with copper thimbles complete all as specified and directed by Engr-in-Charge. 101 Supply and fix Modular switch 1 way 6A, 1 module 102 Supply and fixmodular Socket, 6A - 2/3 pin combined 2 moduler 103 Supply and fixModular switch 1 way 16A, 1 module 104 Supply and fixmodolar Socket 6A/16A - 2/3 pin combined2 module, 105 Supply and fix ceiling rose surface type bakelite/PVC three terminal 65x50mm 106 S & F Modular white cover plate with frame 2 Module 107 S & F Modular white cover plate with frame 3 Module 108 S & F Modular white cover plate with frame4 Module 109 S & F Modular white cover plate with frame 6 Module 110 S & F Modular white cover plate with frame 8 Module 111 Supply, Fixing , Testing and Commissioning of Single phase isolation transformer to be installed at input power supply of L-2 switch,via 16 Amps MCB and with power earthing point specification as follows 1Ph, Capacity 1KVA, Input 230V AC ±10%,Output 230V±10%,50 Hz,cooper wire,work efficiency more than 95%,potential between earth to neutral less than 1 Volt with all standard fitting as per direction of Engineer in charge 112 Supply, Fixing , Testing and Commissioning ofIsolation transformer of capacity 5 KVA, single phase ,50 Hz , Copper wound , Air cooled , class of insulation A ,metallic body duly powder coated designed for input Voltage range 240+-5% and output voltage range 240+-5% ,Ratio 1:1 , indoor , efficiency more than 95 % , Potential difference between neutral to earth less than one volt with all standard fittingsas per direction of Engineer in charge 113 Supply, Fixing , Testing and Commissioningof Three Phase Surge Protector Device to be installed at input power supply of L-2 switch all as specified and directed by Engr-In-Charge 114 S&F wall mounted Industrial grade metal enclosure box made from 3mm thick CRCA sheet consist of following Items:-(a) Panel mounting Industrial grade socket/plug outlet 16 A,IP44(b) SPD ,1.5kv,320A,20kA - 1 Nos(c ) MCB SP 16 A- 1 Nos 115 S&F Vertical double door Distribution board TPN 4 way 125 A rated busbarconsisting ofMCCB. 63 A 18KA - 1 Noincluding fixing on wallsurface and making good the disturbed surfacemaking all nacessary incomming and out going connections using proper size copper thimblescompleteall as required on site all as directed 116 Supply and fixing in replacement sheet metal enclosure with DBs ( grouted in walls) double door type for MCBs 12 ways with 200 Amps 240 volts rated bus bar incl taking down old DB all as specified. 117 Material and labour for taking down serviceable Fire Alarm panel from one location and re-install the same at same /another location including fixing brackets/nut bolts incl testing and commessioning of the same all as specified and directed 118 Material and labour for taking down serviceable Smoke / Heat / Fire detector from one location and re-install the same at same /another location including necessery cable upto Fire alarm panelincl testing and commessioning of the same all as specified and directed 119 Supply and fix adressable smoke Detectors Complying with and type certified to EN-45 type multisensor detector with heat and smoke combination Photoelectric / Optical with base with self built intelligence as per IS: 11360 all as specified. 120 Supply, install, testing and comissioning of adessable break glass manual call pointincluding sunken boxes, with built in monitor module will all acessories and signal indicator complete as per tech specification and shall be UL listed complete. 121 Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,4 core, 1100 Volts grade. 122 Material and labour for taking down serviceable split AC of capaicty upto 2.0 TR from one location and re-install the same at same /another another location including fixing brackets, gas charging, brazing and additional required copper piping incl testing and commessioning of the same all as specified and directed 123 Supply, Install testing and commessioning Single pole and neutral enclosure 240 Volts with a two pin and earth plug and socket complete with one single pole MCB 20 Amp all as specified and directed 124 Material and labour for providing point wiring with two runs of 4 Sqmmmulti stranded copper conductor FRLS PVC insulated single core 1100 volts grade & with one run of 1.5 Sqmm single core copper stranded FRLS PVCinsulated 1100 volts grade wire for continuous earthing complete in and including PVC casing and caping,ISI Marked complet for housing one 15 to 20 A Switch / socketscomplete 125 Supply, Install , Testing and Commissioning of wall mounted enclosure box made from 3mm thick CRCA sheet enclosure consist of following items for 3 Phase 2 AC timer & Controller of Auto switching timer unit suitable for operate 8.75 TR package type AC:-(a) Timer - 1 No(b) Contactor 32 amps - 2 No(c ) Indication lamp - 1 No

Key Value

Document Fees
INR 500 /-
Tender Value
INR 49 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail