Tender For Cleaning And Maintenance Of Sewage Lines Under Age B R M At Faridkot Mil Stn; 1 M&L for cleaning of existing sewage lines upto & including200 mm dia at any depth by rodding /mechanically by jetting machine as required at site from manhole and well finishing after cleaning including getting out sludge if any and liquid materials from connecting manholes deposited in lines, removing the solid and sludge to any distance place outside the defence land at their own cost and cost of removal shall be included in the quoted rates complete all as specified and directed by Engineer-in-Charge.Note : Quoted rates shall deemed to be included for cleaning all manholes of measured sewage line 2 All as per Srl item No 01 here-in-before but exceeding 200 mm dia and not exceeding 450mm dia of pipe 3 M&L for cleaning of existing drain pipes upto & including300 mm dia at any depth by rodding /mechanically as required at site from manhole and well finishing after cleaning including getting out sludge if any and liquid materials from connecting manholes deposited in lines removing the solid and sludge to any distance place outside the defence land at their own cost and cost of removal shall be included in the quoted rates complete all as specified and directed by Engineer-in-Charge.Note : Rates to be quoted for Scattered pockets atMuktsar and Nathewala 4 M&L for Cleaning of Manhole upto 2m depth after plugging the sewage line by de-sludging of manhole/septic tank and removal of sludge outside defence land complete all as specified and directed by Engineer-in-Charge 5 M&L for Cleaning of Manhole from 2.0m to 4.0m depth after plugging the sewage line by de-sludging of manhole/septic tank and removal of sludge outside defence land complete all as specified and directed by Engineer-in-Charge 6 Cleaning & de-slugging by mechanical means i.e. by Honeysuckers : mechanical sewage cleaning trucks/tractor etc., removing sludge from the sump well/ septic tank/soakage pits/manholes etc., of any capacity and any depth, in foul condition including all necessary T&P required for removal of sludge and solid contents to be dispose off outside defence land complete all as specified and directed by Engineer-in-Charge.Note : Rates are to be included for Scattered pocketsMuktsar and Nathewala 7 Removing blockages including cleaning of CI pipes/SWSG pipes from kitchen/bath/wash hand basin /urinal/WC of any length upto gully trap incl cleaning of floor traps upto and including 1st manhole by rodding/choke remover manually or otherwise including refixing of oval access door covers complete all as specified and directed by Engineer-in-Charge.Note : Quoted rates for 01 Job shall deemed to be included for cleaning all blockage of 01 quarter / 01 toilet block in OTM accn 8 Dismantling and disconnecting existing PVC /CI soil waste/vent pipe 100/75 mmbore fixed to wall, laid in trenches incl all fittings & accessories and removing to MES store complete all as specified 9 S&F 110 mm bore of pipe PVC (SWR) pipes heavy grade single socket in any length with rubber ring joint fixed to walls with MS clamps or laid in trenches complete all as specified and directed. 10 S&F 75 mm bore of pipe PVC (SWR) pipes heavy grade single socket in any length with rubber ring joint fixed to walls with MS clamps or laid in trenches complete all as specified and directed. 11 S&F in repair 110 mm bore PVC (SWR) bends heavy grade of any radius with or without access door as reqd and fixed to PVC pipes complete all as specified and directed. 12 S&F in repair 75 mm bore PVC (SWR) bends heavy grade of any radius with or without access door as reqd and fixed to PVC pipes complete all as specified and directed. 13 S&F in repair 110 mm bore PVC (SWR) junction (T) heavy grade with or without access door as reqd and fixed to PVC pipes complete all as specified and directed. 14 S&F in repair 75 mm bore PVC (SWR) junction (T) heavy grade with or without access door as reqd and fixed to PVC pipes complete all as specified and directed. 15 S&F in repair 110 mm bore PVC (SWR) branch piece heavy grade with or without access door as reqd and fixed to PVC pipes complete all as specified and directed. 16 S&F in repair 75 mm bore PVC (SWR) branch piece heavy grade with or without access door as reqd and fixed to PVC pipes complete all as specified and directed. 17 S&F 75mm dia of long body PVC Floor trap with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B1 in repair completeall as specified. 18 S&F for 100 mm dia of long body PVCP or S trap including jointing to waste pipe fixed in cement concrete 1:2:4 type B1 in repair completeall as specified. 19 S&F 100mm dia Cast Iron soil waste & vent pipes in any length with or without ears, with cement joints fixed to walls with MS clamps or laid in trenches completeall as specified 20 S&F 75mm dia Cast Iron soil waste & vent pipes in any length with or without ears, with cement joints fixed to walls with MS clamps or laid in trenches completeall as specified 21 S&F in repair 100 bore, CI bends (any radius), diminishing pieces or tapers (large bore measured) with oval access door as in repairs complete all as specified 22 S&F in repair 75 bore, CI bends (any radius), diminishing pieces or tapers (large bore measured) with oval access door as in repairs complete all as specified 23 S&F in repair 100 bore, CI Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches as in repairs complete all as specified and directed. 24 S&F in repair 75 bore, CI Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches as in repairs complete all as specified and directed. 25 M&L in repairs CI Floor trap long neck 75 mm dia, with stainless steel grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4) etc fixed in repairs & making floor good as per adjacent finishes completeall as specified 26 S&F Vitreous china squatting pan Orrisa pattern, size 580x440mm white with integral foot rests including necessary lime concrete and to flushing pipe, antisyphonage pipe etc. with flush pipe PVC 32mm dia and 100mm bore cast iron P or S trap long neck for connecting WC to branch piece with cement joints, fixed in repairs complete all as specified 27 S&F in repair Vitreous china wash down water closet pan (pedestal pattern), white including PVC seat cover complete all as specified and directed 28 Demolition and breaking up drain pipe (Salt glazed stoneware/AC or Reinforced concrete) 150 mm dia set in cement mortar including demolition of haunching concrete and disposal of rubbish to low lying area within station complete all as specified & directed by Engineer-in-Charge 29 Demolition and breaking up drain pipe (Salt glazed stoneware/AC or Reinforced concrete) 200 mm dia set in cement mortar including demolition of haunching concrete and disposal of rubbish to low lying area within station complete all as specified & directed by Engineer-in-Charge 30 Demolition and breaking up drain pipe (Salt glazed stoneware/AC or Reinforced concrete) 300 mm dia set in cement mortar including demolition of haunching concrete and disposal of rubbish to low lying area within station complete all as specified & directed by Engineer-in-Charge 31 S&F Reinforced concrete pipes class NP-2 laid, jointed and tested complete with collar of size 150mm(internal dia) in foul condition all as specified and directed by Engineer-in-Charge. 32 S&F Reinforced concrete pipes class NP-2 laid, jointed and tested complete with collar of size 200mm(internal dia) in foul condition all as specified and directed by Engineer-in-Charge. 33 S&F Reinforced concrete pipes class NP-2 laid, jointed and tested complete with collar of size 300mm(internal dia) in foul condition all as specified and directed by Engineer-in-Charge. 34 S&F DWC HDPE pipe 300 mm dia (minimum wall thickness 2 mm) Stiffness Class SN 8 , along with necessaryjointing materials collars/ couplers/ tees / union/ socket rings etclaid, jointed and tested complete as per IS16098 Part 2 specifications and as directed by Engineer-in-Charge. 35 M&L for 100mm thick Concrete bed to 150mm drain pipes including forming cradles; in cement concrete 1:4:8 type D2 complete all as specified and directed. 36 M&L for 150mm thick Concrete bed to 200mm drain pipes including forming cradles; in cement concrete 1:4:8 type D2 complete all as specified and directed. 37 M&L for 150mm thick Concrete bed to 300mm drain pipes including forming cradles; in cement concrete 1:4:8 type D2 complete all as specified and directed. 38 M&L for PCC 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as in coping, benching of manholes, including necessary formwork, weathering, slightly rounded or chamfered angles complete all as specified and directed 39 M&L for extra for forming fair finish to drain or channel exc 15cm but n.exc 30cm in width or girth complete all as specified & directed 40 Excavation in trenches not exc. 1.5 meter wide and not exc. 1.5 meter in depth in foul condition for foundation etc and getting out in soft/loose soil in foul condition complete all as specified and directed by Engineer-in-Charge.Note : Necessary dewatering of water shall be included in the unit rate of item 41 All as per Srl item No 40 here-in-before but exc.1.5 m andnot exc. 3.00 m in depthcomplete all as specified and directed by Engineer-in-Charge 42 Returning, filling in including spreading leveling watering and well ramming in layers not exc 25cm in soft /loose soil complete all as specified and directed by Engineer-in-Charge. 43 Removing excavated material or surplus soil not exc 250 meter and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge. 44 Demolition of cement concrete (unreinforced) as in ground floors and pavings, manhole bedding, drain bedding, road etc not exceeding 15cm thickness (below or above ground level) of sewer lines and disposal of rubbish to low lying area within station complete all as specified and directed by Engineer-in-Charge. 45 M&L for cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) as infoundation filling and mass concrete complete all asspecified and directed by Engineer-in-Charge. 46 M&L for Pre cast cement concrete 1:2:4 type B-I using 20mm graded stone aggregate set in CM 1:6 as in Manhole cover including all necessary formwork and placing where directed complete all as specified 47 S&F MS TMT Bars of 8mm to 10mm dia, cut to length, bent to shape requiredincluding cranking, bindingspirally for hooping for columns hooking ends and bindingwithand including MS wire (annealed) not less than 0.9 mm dia or securing with clipall as specified 48 S&F in repairSFRC (Steel fibre Reinforcement concrete cover & frame ) MD-20, conforming to IS-12592, graded rectangular clear opening 560X560x 90 mmthick and fixed over manholeand make good of manhole complete all as specified and directed 49 S&F in repairSFRC (Steel fibre Reinforcement concrete cover & frame ) MD-20, conforming to IS-12592, graded circular clear opening 560 mm , 90 mm thick and fixed over manholeand make good of manhole complete all as specified and directed 50 Demolition ofbrick work or stone boulder masonary, built in cement mortar or cement lime mortar including all quoins, pillars etc in any position and stacking them and disposing off the unserviceable material and rubbish complete all as specified and directed by Engineer-in-Charge. 51 M&Lfor brick work with oldsize fly ash bricks, straight or covered on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed by Engineer-in-Charge 52 All as per Srl item No 51 here-in-before but except fly ash bricks complete all as specified and directed by Engineer-in-Charge 53 Taking down cement plaster on brick or stone walls, etc. including raking outjoints, hacking for key, scrubbing down with water, etc. complete as specified and directed. 54 M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge 55 M&L for Dismantling terrazzo/ glazed tiles as in floor/ skirting/ dado including cement mortar bedding ( but not backing ) complete all as specified. 56 S&F Non skid ceramic tiles 7 to 8 mm in patches thick (coloured tiles) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, as in floors set and jointed in neat cement slurry and pointed in coloured cement to match the coloured tiles over and including 15mm thick screed bed or bedding layer of CM 1:4 complete all as specified as directed by Engr-in- Charge 57 M&L for Cutting into existing manholes for connecting new line, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required for 150mm dia up to 300mm dia complete all as specified and directed