Tender For Capacity Augmentation Of Hpre Plant; 1 Dismantling of existing 2 nos. 115 M3 MS tanks with glass wool insulation, 1 no. 18 M3 MSFRP tank with all accessories. Details a per Sl No 1 in BOQ 2 Fabrication and supply of 60 M3 MS conical bottom tanks with agitator along with all accessories.Details as per Sl No 2 in BOQ 3 Fabrication and supply of 30 M3 MS conical bottom tanks with agitator along with all accessories. Details as per Sl No 3 in BOQ 4 Fabrication and supply of 30 M3 MS conical bottom tanks with grid plates, agitator along with all accessories. Details as per Sl No 4 in BOQ 5 Fabrication and supply of 1.5 M3 MS conical bottom tanks with agitator along with all accessories. Details as per Sl No 5 in BOQ 6 Supply, installation, commissioning and performance testing of ODS pump 4 size as per attached technical specification and scope of work. Details as per Sl No 6 in BOQ 7 Design, Fabrication, Inspection, Supply, Transportation, unloading at site, Erection, Installation, commissioning & Performance testing of Vertical bottom discharge type automatic Centrifuge of discharge capacity 350-400 Kg/batch for Cerrous carbonate with accessories including Hydraulic Power Pack, electrical accessories, Instruments with PLC system, Control valves complete with cabling, electrification etc. Details as per Sl No 7 in BOQ 8 Fabrication, supply & installation of FRP Flash mixer of 30 m3/hr capacity for effluent treatment at ETP as per attached technical specification and scope of work. Details as per Sl No 8 in BOQ 9 Supply and installation of Microprocessor based UV/VIS Spectrophotometer (True Double beam UV visible Spectrophotometer sealed & quartz coated with Czerny- Turner monochromatic) as per technical specification along with required software and computer.Details as per Sl No 9 in BOQ 10 Obtaining PESO license for dismantling existing diesel storage tank and changing to new diesel storage tank.Details as per Sl No 10 in BOQ 11 60 cum MS tank foundation . Details as per Sl No 11 in BOQ 12 30 cum MS tank foundation . Details as per Sl No 12 in BOQ 13 Construction of Lean to shed b/w Nd Pr godown & SEP. Details as per Sl No 13 in BOQ 14 Construction of Lean to shed at Northern side b/w REP-II & SEP. Details as per Sl No 14 in BOQ 15 Construction of structural steel shed b/w pilot plant & REP-II Details as per Sl No 15 in BOQ 16 Construction of RE Chloride storage cum dissolution shed. Details as per Sl No 16 in BOQ 17 Construction of underground treated effluent collection pit. Details as per Sl No 17 in BOQ 18 Demolishing RCC structures such as floor slabs, old tank / equipment foundation, roads, columns, beams, slabs etc., any other RCC concrete elements at all levels & heights manually or by mechanical means using a chain-driven excavator machine / jaw crusher into small pieces etc. Details as per Sl No 18 in BOQ 19 Demolition of RCC portal frame structure, underground structures etc., using electrically operated diamond wire saws for horizontal slicing and diamond wall saws for vertical slicing to cut the structure into small pieces. etc. Details as per Sl No 19 in BOQ 20 Engaging concrete cutter 2 feet dia (approx) using diamond wheel suit to existing site condition for cutting of RCC slab/floor, roads (concrete & bitumen) of 200 to 300mm thickness including necessary scaffolding,platform, labour charges etc to carry out the complete work etc. Details as per Sl No 20 in BOQ 21 Dismantling, chipping, removal of plain cement concrete / rubble masonry / soling / brick masonry etc., using portable heavy-duty concrete breaker machine/ jag hammer or manually including cutting of re-bars using grinder/gas cutter & removing of all debris generated. The waste generated during the work etc.Details as per Sl No 21 in BOQ 22 Dismantling and removing existing all type of roof sheets (Asbestos Cement, metallic ,FRP, Polycarbonate sheets ,PVC) roofing & cladding including ridges & roof bolts, screws using all necessary tools, equipment, scaffoldingetc. Details as per Sl No 22 in BOQ 23 Dismantling and removal of existing FRP (Fiber Reinforced Plastic) / UPVC rainwater gutter, including all necessary supports, clamps, brackets and accessories without damage to the surrounding structure etc.Details as per Sl No 23 in BOQ 24 Dismantling of MS structural by appropriate cutting method (cold cutting/gas cutting etc.) The work includes cutting, removing of MS structural like columns, beam, rafters, purlins, bracings, platform, staircase, etc. Details as per Sl No 24 in BOQ 25 Earthwork excavation for tank foundation, columns, effluent collection pit by mechanical means & as directed, in all classes of soil up to a depth of about 5 m from the existing ground level & asrequired to suit site conditions including removing all waste materials, vegetation, trees,scrapsetc.Details as per Sl No 25 in BOQ 26 Providing MS sheet piles with a 5mm profile and 55cm width and at a depth of 6m. The sheet piles will be supported with horizontal ISMB 200 or ISMB 300 beams at the top and vertical support will be provided with mechanical equipment such as the chain driven excavator of suitable capacity and back hoe loaders.Details as per Sl No 26 in BOQ 27 Providing and laying GSB 200mm thick (approx) over the existing surface as directed by EIC including levelling and consolidation to form a compact surface by pouring water, compacting with vibratory rollers and well consolidated properly etc. Details as per Sl No 27 in BOQ 28 Providing and laying in position plain cement concrete of mix 1:3:6 (1 part cement, 3 parts coarse sand, and 6 parts graded broken stone aggregate of 40–20 mm nominal size) for tank foundations, columns, plinths or other locations etc.Details as per Sl No 28 in BOQ 29 Providing and laying a polythene sheet of 200 micron (800 gauge) thickness as a single piece to the full width of the proposed treated effluent collection pit, with proper overlaps of approximately 30 cm. Measurement will be taken for the laid area only, excluding overlaps. Details as per Sl No 29 in BOQ 30 Supply and laying of reinforcement high-yield strength deformed (HYSD) bars of Fe 500 grade, including cutting to required sizes, bending, placing in position, and binding with 18/20 gauge black annealed or GI tying wire. Details as per Sl No 30 in BOQ 31 8 mm dia bar - drilling length of 100-120mm,10 mm dia bar - drilling length of 100-120mm,12 mm dia bar - drilling length of 120-140mm,16 mm dia bar - drilling length of 160-180mm.Details as per Sl No 31 in BOQ 32 Providing & laying of Reinforced Cement Concrete RCC for raft foundation, footings, columns, beams, slabs, floors, all proposed RCC elements (M30 Grade as per IS 456) with minimum cement content of 380 kg/m3 of concrete by using 20-12 mm downgraded stones, machine mixed, mechanically vibrated,consolidated, curing, including usage of quality material as approved, cost, conveyance, lead, lift of all materials, labour, necessary scaffoldingetc. Details as per Sl No 32 in BOQ 33 Providing & laying of Reinforced Cement Concrete RCC (M-25 Grade as per IS 456) for pit/sump, dyke wall, floor screed concrete etc.Details as per Sl No 33 in BOQ 34 Providing shuttering/formwork using plywood with sufficient wooden runners or MS sheets, with adequate strength to withstand the all type of load, by providing props, supports, or span supports during compaction of concrete with a mechanical vibrator for RCC structure such as raft foundation,walls, beams, columns, footings, tank foundation etc. Details as per Sl No 34 in BOQ 35 Providing masonry work using solid concrete block of standard size of 30cm x 20cm x 15cm / 30cm x 20cm x 10cm in superstructure above plinth level upto floor V level in cement mortar 1:5 (1 Cement: 5 coarse sand) including raking out joints, finishing to proper lines & levels, chipping the existing floor concrete surface for necessary bonding, curing etc. Details as per Sl No 35 in BOQ 36 Providing Plastering in CM 1:4, 12 mm thick average in new and existing masonry structure wherever required, mixing & application of mortar etc. Details as per Sl No 36 in BOQ 37 Supply, fabrication & erection of MS structural supports such as columns, rafters, tie beams, purlins, wind bracing, cross bracing, roof supports, side cladding angles, louvers, supporting cleats, stiffeners, battens, joint plates, monkey ladder, staircase and other supports using all type of structural steel sections such as angles, beams, channels, plates or built-up sections, etc. Details as per Sl No 37 in BOQ 38 Providing high-tensile MS rods of 20mm dia for intermediate sag rods between roof purlins with threading of 100mm at both ends, to reduce sagging and lateral movement of MS purlins, including supply of specified, providing nuts, washers etc. Details as per Sl No 38 in BOQ 39 Supply, providing, laying and fixing of industrial profile PVC roof sheet 1.9mm thick white colour, (overall width of 1063mm and crest height of 40mm with centre to centre crest of 250mm), etc. Details as per Sl No 39 in BOQ 40 Supply and installation of UPVC gutter of size of about 320X250mm of length 3m each for diverting rainwater from roof and a weight 3kg per meter with a holding capacity of 52 liter/metreetc. Details as per Sl No 40 in BOQ 41 Supply & fixing PVC pipe of 140mm dia or nearest, 4 kg/cm2 pressure rating for rain water down take from roof gutter through side cladding sheet, barge board (roof sheet) including suitable specials such as bends, tees, elbows etc.Details as per Sl No 41 in BOQ 42 Supply & fixing MS bolts & nut of 25-32mm dia for RCC tank foundations, columns with washer plate with 800mm length & about 175mm thread as per the spacing given in detailed engineering drawing etc.Details as per Sl No 42 in BOQ 43 Providing non-shrinkage cementitious grout 50 mm thick at the top of column footings/ tank foundations or at locations. Details as per Sl No 43 in BOQ 44 Providing and applying paint on the exterior surfaces of the proposed locations as directed by the Engineer-in-Charge (EIC), including masonry walls, RCC columns, beams, sunshades, roof slabs, and other areas within the factory premises. Details as per Sl No 44 in BOQ 45 Supply and applying paint on the interior surfaces of the proposed locations as directed by the Engineer-in-Charge (EIC), including masonry walls, RCC columns, beams, ceilings, and roof slabs. Details as per Sl No 45 in BOQ 46 Providing and finishing the concrete floor surface at the proposed locations as directed by the Engineer-in-Charge (EIC), using a power trowel machine to achieve a smooth finish, proper line & level etc. Details as per Sl No 46 in BOQ 47 Providing & applying 2 coats of coal tar epoxy paint in underground collection pit using approved brand & shade, application as per manufacturer’s recommendations including cost & conveyance of all materials, labour, necessary scaffolding, working platform, staging etc. Details as per Sl No 47 in BOQ 48 Providing & laying PVC/rubber water stopper 150 mm wide, 6 mm thick at all construction joints, fixing in proper line & level, including cost, conveyance of materials, labour etc. Details as per Sl No 48 in BOQ 49 Supplying water proofing compound of approved make for mixing in cement mortar as per manufacturer recommendation and as directed by EIC, including cost & conveyance of material, labour charges etc.Details as per Sl No 49 in BOQ 50 Providing FRP Lining with three layers or more chopped strand matting of 450 grams/m2 (GSM) in bisphenol resin to minimumthickness of 3.0mm and One layer of surface matting after proper surface preparation includingapplication of one coat of resin before laying of first layerof glass fiber mat. .Details as per Sl No 50 in BOQ 51 Providing & sealing with ‘cold applied bituminous caulking compound with mineralfillers’ (tar plastic of STP or equivalent) atjunction of RCC & PCC works, 75-100 mmwide, 20 mm thick approx, surfaces to leakproof including cost, conveyance, labour etc.Details as per Sl No 51 in BOQ 52 Providing heavy duty PU screed lining, 5mm average thick, over the existing concrete floor area using approved brand & shade of materials as per manufacturer recommendations etc. Details as per Sl No. 52 in BOQ 53 Supply and fix 600 mm diameter powder-coated aluminium wind-driven turbo roof extractor, installed on the roof using an FRP base matching the profile of the 2 mm thick roofing sheet..Details as per Sl No. 53 in BOQ 54 Fabrication, supply, and fixing of powder-coated aluminium casement/fixed windows having an outer frame size of approximately 60 mm × 50 mm with a thickness of 1.6 mm (or nearest available section) etc. Details as per Sl No. 54 in BOQ 55 Fabrication, supply & fixing of UPVC window (casement) of outer frame size 60mm x 60mm (approx), thickness-1.1mm or nearest, width of shutter- 60cm or equally divide the existing opening length, heavy duty rail/track, 5mm thick clear toughened glass, fixing the windows using screws/anchor bolts, handle, beading to air tight closure using EPDM gasket etc.Details as per Sl No. 55 in BOQ 56 Supply & fixing fully furnished pre hung WPC door for operator & office rooms, both side plain vertical grain with matching PVC wrapped WPC jamb of 100mm x 45mm width with front side architrave back side trackers etc.Details as per Sl No. 56 in BOQ 57 Providing & fixing good quality vitrified tiles of 600mmx600mm or 600mmx1200mm, 8mm thickness double charged, anti-skid, anti-strain & scratch resistant at all levels, etc. Details as per Sl No. 57 in BOQ 58 Engaging a core cutting machine for making holes of 25 mm to 200 mm diameter cores using a diamond core cutter machine to a depth of 300 to 500mm for drainage holes, pipelines, cable lines, down-take pipes, etc. Details as per Sl No. 58 in BOQ 59 MCC – ReCl3 Neutralization Tanks:4P, 400A, MCCB as incomer, 20HP Star-Delta starter - 2 No. with 63A SFU etc.Details as per Sl No. 59 in BOQ 60 MCC - Iron Elimination Tanks:4P, 400A, MCCB as incomer, 20HP Star-Delta starter -4 No. with 63A SFU etc. Details as per Sl No. 60 in BOQ 61 MCC – ReCl3 Dissolution tanks:4P, 125A, MCCB as incomer, 20HP Star-Delta starter -2 No, 7.5 HP DOL starter etc.Details as per Sl No. 61 in BOQ 62 Supply of 12 Way PDB with 125A MCCB as incomer and 32 A MCBs as outgoing. Details as per Sl No. 62 in BOQ 63 Supply of 18 Way LDB with 63A, 2P ELCB as incomer and 6 A MCBs as outgoing. Details as per Sl No. 63 in BOQ 64 Supply of 3.5C x 185 Sq.mm Al conductor XLPE Armoured Cable. Details as per Sl No. 64 in BOQ 65 Supply of 3.5C x 70 Sq.mm Al conductor XLPE Armoured Cable. Details as per Sl No. 65 in BOQ 66 Supply of 4C x 4 Sq.mm Cu conductor XLPE Armoured Cable. Details as per Sl No. 66 in BOQ 67 Supply of 4C x 2.5 Sq.mm Cu conductor XLPE Armoured Cable. Details as per Sl No. 67 in BOQ 68 Supply of 4C x 1.5 Sq.mm Cu conductor XLPE Armoured Cable. Details as per Sl No. 68 in BOQ 69 Supply of Single compression cable gland suitable for 3.5C x185 Sq.mm Al conductor XLPE Armoured Cable.Details as per Sl No. 69 in BOQ 70 Supply of Single compression cable gland suitable for 3.5C x 70 Sq.mm Al conductor XLPE Armoured Cable.Details as per Sl No. 70 in BOQ 71 Supply of Single compression cable gland suitable for 4C x 4 Sq.mm Cu conductor XLPE Armoured Cable.Details as per Sl No. 71 in BOQ 72 Supply of Single compression cable gland suitable for 4C x 2.5 Sq.mm Cu conductor XLPE Armoured Cable. Details as per Sl No. 72 in BOQ 73 Supply of Single compression cable gland suitable for 4C x 1.5 Sq.mm Cu conductor XLPE Armoured Cable. Details as per Sl No. 73 in BOQ 74 Supply of Al crimping socket (185 Sq.mm). Details as per Sl No. 74 in BOQ 75 Supply of Al crimping socket (90 Sq.mm). Details as per Sl No. 75 in BOQ 76 Supply of Al crimping socket (70 Sq.mm). Details as per Sl No. 76 in BOQ 77 Supply of Al crimping socket (35 Sq.mm). Details as per Sl No. 77 in BOQ 78 Supply of Cu crimping socket (4 Sq.mm). Details as per Sl No. 78 in BOQ 79 Supply of Cu crimping socket (2.5 Sq.mm). Details as per Sl No. 79 in BOQ 80 Supply of Cu crimping socket (1.5 Sq.mm). Details as per Sl No. 80 in BOQ 81 Supply of Cu crimping socket (1 Sq.mm). Details as per Sl No. 81 in BOQ 82 Supply of earth strip 25 x 3mm. Details as per Sl No. 82 in BOQ 83 Supply of earth strip 4 Sq. mm insulated copper wire. Details as per Sl No. 83 in BOQ 84 Supply of LED lights. .Details as per Sl No. 84 in BOQ 85 Supply of FRP cable Tray. Details as per Sl No. 85 in BOQ 86 Supply of M S Flat 40 x 6 mm. Details as per Sl No. 86 in BOQ 87 Supply of M S Angle 40 x 40 x 6 mm. Details as per Sl No. 87 in BOQ 88 Supply of 30 mm heavy duty MS Pipe.Details as per Sl No. 88 in BOQ 89 Supply of 450mm heavy duty exhaust fan.Details as per Sl No. 89 in BOQ 90 Supply of 90 x 90 mm anticorrosive PVC junction Box.Details as per Sl No. 90 in BOQ 91 Supply of magnetic flow meter.Details as per Sl No. 91 in BOQ 92 Supply of variable area flow meter.Details as per Sl No. 92 in BOQ 93 Supply of Radar Level Transmitter.Details as per Sl No. 93 in BOQ 94 Supply of 12 pair control cable.Details as per Sl No. 94 in BOQ 95 Supply of 12 core control cable.Details as per Sl No. 95 in BOQ 96 Supply of 2 pair control cable.Details as per Sl No. 96 in BOQ 97 Supply of PVC gland (PG gland) suitable for 12 pair control cable.Details as per Sl No. 97 in BOQ 98 Supply of PVC gland (PG gland) suitable for 12 core control cable.Details as per Sl No. 98 in BOQ 99 Supply of PVC gland (PG gland) suitable for 2 pair control cable. Details as per Sl No. 99 in BOQ 100 Supply of 300 x 300 x 210 mm Junction Box.Details as per Sl No. 100 in BOQ 101 Supply of instrumentation shut off valve.Details as per Sl No. 101 in BOQ 102 Supply of Induction Motor 20 HP, 1500RPM Synchronous speed, Flange Mount.Details as per Sl No. 102 in BOQ 103 Supply of Induction Motor 20 HP, 1000RPM Synchronous speed, Base Mount.Details as per Sl No. 103 in BOQ 104 Supply of Induction Motor 20 HP, 1000RPM Synchronous speed, Flange Mount.Details as per Sl No. 104 in BOQ 105 Supply of Induction Motor 15 HP, 1500RPM Synchronous speed, Flange Mount.Details as per Sl No. 105 in BOQ 106 Supply of Induction Motor 15 HP, 1500RPM Synchronous speed, base Mount.Details as per Sl No. 106 in BOQ 107 Supply of Induction Motor 10 HP, 1500RPM Synchronous speed, base Mount. Details as per Sl No. 107 in BOQ 108 Supply of Induction Motor 7.5 HP, 3000RPM Synchronous speed, base Mount .Details as per Sl No. 108 in BOQ 109 Supply of Induction Motor 7.5 HP, 1500RPM Synchronous speed, base Mount.Details as per Sl No. 109 in BOQ 110 Supply of Induction Motor 5 HP, 3000RPM Synchronous speed, flange Mount.Details as per Sl No. 110 in BOQ 111 Supply of Induction Motor 5 HP, 3000RPM Synchronous speed, base Mount.Details as per Sl No. 111 in BOQ 112 Supply of Induction Motor 3HP, 300RPM Synchronous speed, flange Mount. Details as per Sl No. 112 in BOQ 113 Supply of Induction Motor 3 HP, 3000RPM Synchronous speed, base Mount. Details as per Sl No. 113 in BOQ 114 Supply of Induction Motor 2 HP, 3000RPM Synchronous speed, base Mount.Details as per Sl No. 114 in BOQ 115 Supply of Induction Motor 1 HP, 3000RPM Synchronous speed, base Mount. Details as per Sl No. 115 in BOQ 116 Supply of Induction Motor 1 HP, 1500RPM Synchronous speed, base Mount. Details as per Sl No. 116 in BOQ 117 Installation and Commissioning of Rittal/BCH make MCC panel having size :4500mm x 2200mm x 450mm MCC - ReCl₂ Neutralization Tanks.Details as per Sl No 117 in BOQ 118 Installation and Commissioning of Rittal/BCH make MCC panel having size : 3600mm x 2200mm x 450mm MCC - Iron Elimination Tanks.Details as per Sl No 118 in BOQ 119 Installation and Commissioning of Rittal/BCH make MCC panel having size :2100mm x 1900mm x 450mm MCC – ReCl₂ Dissolution tanks. Details as per Sl No 119 in BOQ 120 Installation and commissioning of 12 Way PDB with 125A MCCB as incomer and 32 A MCBs as outgoing.Details as per Sl No 120 in BOQ 121 Supply Installation and commissioning of 18 Way LDB with 63A, 4P ELCB as incomer and 6 A MCBs as outgoing.Details as per Sl No 121 in BOQ 122 Fabrication of cable tray supports, light fixing supports, exhaust fan fixing supports, DB fixing frames etc.Details as per Sl No 122 in BOQ 123 Surface preparation and painting of cable tray supports, light fixing supports, exhaust fan fixing supports, DB fixing frames etc.Details as per Sl No 123 in BOQ 124 Laying/fixing of FRP cable tray.Details as per Sl No 124 in BOQ 125 Laying and dressing of 3.5C x 185 Sq.mm Al conductor Armoured Cable.Details as per Sl No 125 in BOQ 126 Laying and dressing of 3.5C x 70 Sq.mm Al conductor Armoured Cable.Details as per Sl No 126 in BOQ 127 Laying and dressing of 4C x 4 Sq.mm Cu conductor Armoured Cable.Details as per Sl No 127 in BOQ 128 Laying and dressing of 4C x 2.5 Sq.mm Cu conductor Armoured Cable.Details as per Sl No 128 in BOQ 129 Laying and dressing of 4C x 1.5 Sq.mm Cu conductor Armoured Cable. Details as per Sl No 129 in BOQ 130 Termination of 3.5C x 185 Sq.mm Al conductor XLPE Armoured Cable.Details as per Sl No 130 in BOQ 131 Termination of 3.5C x 70 Sq.mm Al conductor XLPE Armoured Cable.Details as per Sl No 131 in BOQ 132 Termination of 4C x 4 Sq.mm Cu conductor XLPE Armoured Cable.Details as per Sl No 132 in BOQ 133 Termination of 4C x 2.5 Sq.mm Cu conductor XLPE Armoured Cable.Details as per Sl No 133 in BOQ 134 Termination of 4C x 1.5 Sq.mm Cu conductor XLPE Armoured Cable.Details as per Sl No 134 in BOQ 135 Installation and charging of LED light points.Details as per Sl No 135 in BOQ 136 Fixing and installation of Installation 90 x 90 mm anticorrosive PVC junction Box.Details as per Sl No 136 in BOQ 137 Fixing and installation of Heavy duty exhaust fans.Details as per Sl No 137 in BOQ 138 Laying and termination 25 x 3 mm earth copper strip.Details as per Sl No 138 in BOQ 139 Laying and termination 4 Sq. mm earth copper wire.Details as per Sl No 139 in BOQ 140 Laying and dressing of 12 pair 1 Sq.mm Control armoured cable.Details as per Sl No 140 in BOQ 141 Laying and dressing of 12 core 1 Sq.mm Control armoured cable.Details as per Sl No 141 in BOQ 142 Laying and dressing of 1 pair 1 Sq.mm Control armoured cable.Details as per Sl No 142 in BOQ 143 Termination of 12 pair 1 Sq.mm Control armoured cable.Details as per Sl No 143 in BOQ 144 Termination of 12 core 1 Sq.mm Control armoured cable.Details as per Sl No 144 in BOQ 145 Termination of 12 pair 1 Sq.mm Control armoured cable.Details as per Sl No 145 in BOQ 146 Installation of shut of valve.Details as per Sl No 146 in BOQ 147 Supply of MS Structural Steel confirming to IS 2062:2011 or latest such as Angles, I-Beams, Channels, Flats, etc. Details as per Sl No 147 in BOQ 148 Supply of HDPE Pipe 40mm OD, IS 4984:1995 or latest, PN10, Material Grade PE 80- In straight length of 5 to 6 metres along with the HDPE Fittings.Details as per Sl No 148 in BOQ 149 Supply of HDPE Pipe 50mm OD, IS 4984:1995 or latest, PN10, Material Grade PE 80- In straight length of 5 to 6 metres along with the HDPE Fittings.Details as per Sl No 149 in BOQ 150 Supply of HDPE Pipe 63mm OD, IS 4984:1995 or latest, PN10, Material Grade PE 80- In straight length of 5 to 6 metres along with the HDPE Fittings.Details as per Sl No 150 in BOQ 151 Supply of Pipe HDPE 75mm OD, IS 4984:1995 or latest, PN10, Material Grade PE 80- In straight length of 5 to 6 metres along with the HDPE Fittings.Details as per Sl No 151 in BOQ 152 Supply of Pipe HDPE 90mm OD, IS 4984:1995 or latest, PN10, Material Grade PE 80- In straight length of 5 to 6 metres along with the HDPE Fittings.Details as per Sl No 152 in BOQ 153 Supply of Pipe HDPE 150mm OD, IS 4984:1995 or latest, PN10, Material Grade PE 80- In straight length of 5 to 6 metres along with the HDPE Fittings.Details as per Sl No 153 in BOQ 154 Supply of PP Ball Valve 32mm. Details as per Sl No 154 in BOQ 155 Supply of PP Ball Valve 40mm.Details as per Sl No 155 in BOQ 156 Supply of PP Ball Valve 50mm.Details as per Sl No 156 in BOQ 157 Supply of PP Ball Valve 65mm.Details as per Sl No 157 in BOQ 158 Supply ofPP Ball Valve 80mm.Details as per Sl No 158 in BOQ 159 Supply of PP Ball Valve 100mm.Details as per Sl No 159 in BOQ 160 Supply of Carbon Steel Gate Valve, 6 inch.Details as per Sl No 160 in BOQ 161 Supply of Non-Metallic Horizontal Centrifugal Pump of Capacity: 15cu.m./hr, Head: 21m.Details as per Sl No 161 in BOQ 162 Supply of Non-Metallic Horizontal Centrifugal Pump of Capacity: 20cu.m./hr, Head: 30m.Details as per Sl No 162 in BOQ 163 Supply of 4” ODS pump. Details as per Sl No 163 in BOQ 164 Supply of Non Metallic Vertical Sump Pump. Details as per Sl No 164 in BOQ 165 Supply of Cast Iron Submersible Pump. Details as per Sl No 165 in BOQ 166 Supply of 2Ton Wire Rope Electric hoist with Trolley.Details as per Sl No 166 in BOQ 167 Supply of 2Ton Wire Rope EOT Crane. Details as per Sl No 167 in BOQ 168 Supply of Chemical Resistant Wooden Chequered Board of 18mm thick. Details as per Sl No 168 in BOQ 169 Supply of Tube Axial Fan with Duct. Details as per Sl No 169 in BOQ 170 Supply of FRP Duct in Isophthalic resin, 5mm thick for fume exhaust. Details as per Sl No 170 in BOQ 171 Supply of Rubber Lined Diaphragm Valve of size 4 inch. Details as per Sl No 171 in BOQ 172 Fabrication, Erection and Painting of MS Working Platform and Structures for Monorail for installation of Electric Hoist and EOT Crane, Centrifuge, Tanks, Tube Axial Fans along with step ladders, handrails, etc.Details as per Sl No 172 in BOQ 173 Laying of HDPE pipelines and fittings along with valves on the Pipe racks . Details as per Sl No 173 in BOQ 174 Fixing PP Ball Valves and Cast Iron Gate Valves as per the process layout.Details as per Sl No 174 in BOQ 175 Installation and Commissioning of Centrifugal Pumps, ODS pumps, Submersible pumps, Vertical Sump Pump and Electric hoists as per the Process Layout.Details as per Sl No 175 in BOQ 176 Installation and Commissioning of EOT crane of 2 ton capacity.Details as per Sl No 176 in BOQ 177 Installation and Commissioning of 3 nos. of Tube Axial Fan along with the ducts as per the sit condition and as per the instruction of EIC.Details as per Sl No 177 in BOQ 178 Installation of Exhaust Duct FRP lined from newly installed MSFRP tanks to the existing Main FRP Duct.Details as per Sl No 178 in BOQ 179 Fixing of Wooden Chequered Board in the newly fabricated MS Working Platform.Details as per Sl No 179 in BOQ 180 Installation of Rubber Lined Diaphragm Valve of size 4 inch. Details as per Sl No 180 in BOQ