Providing And Fixing Of Fenders Of Rcc Jetty At Chowra Island 2Nd Call- 1 Supplying and fixing of gaint tyre fenders on the berthing face of the Jetty/Warf, making holes, cutting, bending and fixing of MS plate. GI nipples and langes, washer, wire rope, wire grip, cardium compound and accessories in position as directed by the Engineer in charge including cost of giant type fenders, MS plate, GI nipple and flanges, washer, wire rope, wire grip, cardium compound and accessories cost of transportation charge of all materials to worksite, scaffolding charges, all labour charges, cost of minor tools etc complete. 2 Old used tyre of size 520 mm width 1600 to 1800 mm height 3 Old used tyre of size 290-300 mm width 1075 to 1100 mm height 4 Lifting the giant/mini tyre at the berthing face with the help of crane/forklift for replacing nipple flange, wire rope etc. complete and incluing cost of all labour charges and cost of minor tools etc. complete 5 Demolishing cement concretemanually/ bymechanicalmeans includingdisposalofmaterialwithin 50metresleadasper direction of Engineer - in - charge. 6 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) 7 Providing manpower for up keeping, cleaning and other works related to jetty maintenance including watch and ward of jetties as per the direction of Engineer-in-charge, including cost of all labour charges etc. complete 8 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 9 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size de rived from natural sources) 10 Supply, Testing and Fixing of Hot dipped galvanised steel mooring Ring 32 mm dia with hook at the required locations, level and alignment as directed by nodal officer and as per the approved drawing, including cost of mooring ring, cost of all labour charges, transportation charges and minor tools etc, complete. 11 Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit with modular switch, modular plate suitable GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as reqd. 12 GroupC 13 Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 14 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable inthe existing surface/ recessed steel/ PVC conduit as required. 15 a) 3 x 1.5 sq. mm 16 Installation testing and commissioning ofwall bracket /ceiling fittings of all sizes and shapes containing upto two GLS lamps per fitting, complete with all accessories including connection etc. as required. 17 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. 18 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 19 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. 20 Upto 35 sq. mm 21 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 22 3½ X 25 sq. mm (28mm) 23 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. 24 Above 4.5 metre and upto 6.5 metre 25 Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required. 26 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 27 63 mm dia (OD-63 mm & ID-51 mm nominal) 28 Supplying of integrated LED bulk head luminaire, Murphy 10W wall Lamp LED Oval Shape IP54 Water proof cool white or equvilant. 29 Supplying and fixingof 50W LED street lightIP66 similar toSturlite dysen Cool white 6500Kor its equivalent to ISI standard etc as required. 30 Supplying installation, testing and commissioning of ASHLOK make SEE brand safe earthing electro type-19, 50mm dia length 2 mtrs and inner space to be filled with crystaline conductive mixture including filling up with elelctrodite (Back fill compound ) as reqd for safe earth electrode and providing masonary enclusure with cover plate having locking arrangement etc as reqd. 31 Supplying of metallic street light Octagonal pole of length 6 meters made out of bottom dia 130 mm dia and Top dia 70mm GI pipe with GI single arm for street light fittings including fixing of Sintex SMC box of size 280mm x 180 mm x 60mm inside house 8 pole connector & 6 amps MCB with clamping arrangement for SMC box model No. GSJB 2818 etc. as required. 32 Supplying, installation, testing and commissioning of LT out door feeder box of size 1.20 x 1.0 x 0.4m with 4 legs of 1 mtr made out of MS angle and GI plate having both side opening and locking arrangement and to house the following accessories including making foundation and platform of size 1.5 x 1.5m x 0.3mtr height having space for CT energy meter looking glass and inner earthing, painting of 1 coat of primer and 2 coats of finishing paints with inter connection etc. as required. Fuse carrier 200A, 415V - 03 Nos., Copper Bus bar 200A, 600mm long - 2.76 Kg, Isolator 4 Pole 40A, 415V- 01 No.,Power contactor, 4 Pole AC, 415V 40A - 04 Nos., Moduler timer switch 24 hr (SST*- 30 Min) Cat No.DHTED30016 - 01 No., Toggle switch 2 position AC, 240V - 01 No., PVC Connector 8 way - 01 No., Inter connection with suitable copper cable 33 Supplying of following size ISI marked PVC Shelated/XLPE armoured conductor cable of 1.1Kv grade of 3.5 core, 25 sq mm. Make : havells or its equivalent