Indian Tenders

Tender Notice

TDR 52144532
Tendering Authority Municipal Corporation Of Greater Mumbai
Tender No Sch 8 Needles and Syringes By Tender
Tender ID 2025_MCGM_1235679_1
Tender Brief Corrigendum : Tender For Supply Of Needle & Syringes - Disposable Needle Sterile Length 1/2 Guage – 25 3 Suture Needle, Half Circle Triangular Nos. 2 To 20 (Cutting) 4 Insulated Needle For Use With Peripheral Nerve Stimulator 22G X 2 X 50 Mm. 5 Insulated Needle
City mumbai
State Maharashtra
Document Fees INR 35695 /-
EMD INR 300000.0 /-
Tender Value Refer document
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender For Supply Of Needle & Syringes - Disposable needle sterile Length 1/2 Guage – 25 3 Suture needle, half circle triangular Nos. 2 to 20 (Cutting) 4 Insulated needle for use with peripheral nerve stimulator 22G x 2 x 50 mm. 5 Insulated needle for use with peripheral nerve stimulator22G x 35 mm. 6 Insulated needle for use with peripheral nerve stimulator 24G x 1x 25 mm. 7 Echogent needles for USG guided peripheral nerve blocks 20G / 21G x 100 mm. 8 Echogent needles for USGguided peripheral nerve blocks 22G x 50 mm. 9 Epidural needles 16 & 18 guage 7.5cm to 11cm (Disposable) 10 Epidural needles (long length) 18G (more than 100 mm. length) 11 Sterile Disposable Lancet Size 28-32 (Plastic Lancet Needle Type) 12 Sterile disposable Hypodermic plastic “syringe 20cc, CN.” With Leur Lock 13 Hypodermic Syringes,Disposable sterile, sterile pack,with/withoutLeur Lock, hub 1ml syringe with marking at 0.1 ml 14 Asepto Syringe 100 ml ofheavy plastic barrel and rubber bulb with marking. 15 Bag Arm Rubber with cover for B.P. apparatus, adult size VELCRO.Rubber bag size 13 x 23 cms. 16 Keratome, Size – 2.8 MM, Type-Regular(Ophthalmic), Angle-45 Degrees, Bevel type- Bevel up (pointed)Blade-Stainless steel/Carbon steel,Handle- Polycarbonate, use- Disposable Single Use 17 MVR, Gauge – 23G type-Regular(Ophthalmic), Blade-Stainless steel Handle- Polycarbonate, use- single Disposable use 18 Triple lumen catheter 7.5fr with 14G distal lumen, length-15cm. Kit contain 1 Teflon-coated “J” Nitinol guidewire particularly kink-resistant with guide-Advancer. 1 dilator, 10cm long, 3 injection caps, 3 clamps,1 supplementary fixation wing,1 scalpel, 1 syringe 5 ml, 1 adaptor for pressure transducer, 1 puncture needle 18G, 70mm long with a pre-connected valve to aviod air embolism and blood loss, 18g short IV cannula 19 Double Lumen Subclavian/ Jugular Catheter Kit (Adult)PTFE (Teflon) Cannula Curved OD 2.7/D 11.5Fr-12fr/CHX5.3in. (3.8 mm x 13.5 cm) 6 side holes silicon tube s “clamping extension, clamp” “Luer Lock” Y “connector” with protective caps “Size 12.5, 15 with guide wire” “introducer needle, dialator” 20 3FR Double LUMEN CVC catheter with 60mm Double-lumen polyurethane central venous catheter inserted by seldinger technique, Radio opaque material for catheter, The user should be able to choose from 2 type of introducer, i.e.needle 23G or I.V. cannula 22G, Latex free, The central venous catheter set should Contain: 1 double-lumen polyurethane 3Fr catheter, 1 short I.V. cannula 22G, 1 introducer needle 23G, 1 kink resistant guidewire with soft flexible tip, dilator with cylindrical /pencil point tip, 1 secondary fixation wing, 2 injection Caps, 1 scalpel, 1.5 ml syringe 21 Peripherally placedRadiopaque central Single Lumen Catheter. Guage 14/16 (100%) (Needles Size/Catheter Size) Length - 55cm - 70cm 22 Peripherally placedRadiopaque central Single Lumen Catheter. Guage 18/20 (100%) (Needles Size/Catheter Size) Length30cm - 45cm 23 Fully radiopaque PUR catheter 16G for femoral artery centimeter Marking from 5-15cm, Winged hub forskin fixation, supple distal tip. Kit should Contain 1 PUR catheter with XRO lines,1 puncture needle, 1 “J” guidewire with Wishbone-type guidewire advancer, 1 dilator 24 Radial/femoral arterial PE catheter with antikinking collar & fixation wings,straight guide wire, introducer needle.Catherter size G- 18, Length 10cm 25 Radial/femoral arterial PE catheter 20G, 8cm Puncture needle is fitted with a visualization chamber allowing to confirm that the vessel punctured is an artery (pulsatile movement of the blood). The needle is also fitted with a silicone bloodless system valveto avoid loss of blood during vessel puncture and a funnel hub to facilitate the insertion of the guidewire 26 Peripherally inserted central catheter with guide wire with peelable cannula, made of polyurethane, non-toxic, with radio opaque line throughout the catheter with marking every cm with leurconnector at proximal end of cathetereach packed in sterile peel able pouch.Size - 28G, 1 Fr, 20 cm 27 Peripherally inserted central catheter with guide wire with peelable cannula, made of polyurethane, non-toxic, with radio opaque line throughout the catheter with marking every cm with leurconnector at proximal end of cathetereach packed in sterile peel able pouch.Size - 24 G, 2 Fr, 30 cm 28 Umbilical catheter, single lumen, made of non-toxic, medical grade PVC with smooth round distal tip with radio opaque line throughtout the tube with marking every cm with luer connector at proximal end of catheter each packed in sterile peel able pouch. Size - 3.5 Fr, 30 cm 29 Umbilical catheter, single lumen, made of non-toxic, medical grade PVC with smooth round distal tip with radio opaque line throughtout the tube with marking every cm with luer connector at proximal end of catheter each packed in sterile peel able pouch. Size - 4 Fr, 30 cms 30 Umbilical catheter, single lumen, made of non-toxic, medical grade PVC with smooth round distal tip with radio opaque line throughtout the tube with marking every cm with luer connector at proximal end of catheter each packed in sterile peel able pouch. Size - 5 Fr, 40 cms 31 Straight cannulas with soft tip for vitrectomy gauge -23G, type-Retinal Cannula, Overall length-50 MM,Shaft pattern-Straight, Tip Type-Silicone Tube 32 Catheter continuous peripheral nerve block catheter set 18G x 4 3/8 (1.3 x 100mm OR 110 mm.) (Needle) 20G (0.85 x 1000 mm.) (Catheter) 33 Elastomeric pumps with multirate “1, 2, 3 ml / hr.” Total Valume 100 ml or above 34 Elastomeric pumps with multirate “2, 3, 5 ml / hr.”Total Volume 300 ml or above 35 Elastomeric pumps with multirate “5, 7, 12 ml / hr.” Total Volume 300 ml or above 36 Epidural Catheters with “Filter.0.2µm (Micro meter), flat Sterile” Pack with marking clear cathetar with lateral eyes “at the tip, Luer Lock twist” connector or euivalent Cathetar guide/introducer Catheter Size – 16G 37 Epidural Catheters with “Filter. 0.2µm (Micro meter), flat Sterile” Pack with marking clear cathetar with lateral eyes “at the tip, Luer Lock twist” connector or euivalent Cathetar guide/introducer Catheter Size – 18G 38 Combined Spinal Epidural Needles Spinal epidural set pencilpoint/ Lancet Disposable Spinal needle,sterile pack, 25G-27G/16G-18G Luer lock & transperant hub, Tuohy needle length = 7.5 to 11cms.Spinal needle protrusion by 11 - 14mm with epidural Catheter, filter,Loss of resistancesyringe. 39 Complete Epidural Set (Disposable).Epidural needle, catheter filter & Syringe, Tuohy needle, Catheter with guide & lateral eyes marking gradation at 50-150mm at 10mm & at 200mm. Tuohy needle marking At least 3cms from tip & later on every 1 cm. Filter0.2µm (Micro meter), flat Loss of resistance syringe 10cc. Guage 16 Length75mm – 110mm 40 Complete Epidural Set (Disposable). Epidural needle, catheter filter & Syringe, Tuohy needle,Catheter with guide & lateral eyes marking gradation at 50-150mm at 10mm & at 200mm. Tuohy or eqivalent needle marking at least 3cms from tip & later on every 1 cm. Filter 0.2µm (Micro meter) ,flat Loss of resistance syringe7 to 10cc.Marking Guage 18, Length 75mm - 110mm 41 Complete Epidural Set (Disposable). Epidural needle, catheter (22G-40cm) filter & Syringe, Tuohy or equivalent needle,Catheter with guide & lateral eyes marking gradation at 50-150mm at 10mm & at 200mm.Tuohy needle marking at every 1 cm from Tip& later on every 1 cm. Filter 0.2µm (Micro meter),flat Loss of resistance syringe 7 to 10cc. MarkingGuage 19,Length 50mm 42 Complete Epidural Set (Disposable). Epidural needle, catheter filter & Syringe, Tuohy or eqivalent needle,Catheter with guide & lateral eyes marking gradation at 50-150mm at 10mm & at 200mm.Tuohy needle marking at every 1 cm from Tip& later on every 1 cm. Filter 0.2µm (Micro meter), flat Loss of resistance syringe 7 to 10cc.MarkingGuage20, Length 50 mm 43 Central venous catheter Size - 14/16 cm 44 Sterile disposable hypodermic plastic syringes: 100ccC.N.with Leur lock 45 Triple lumen Central venous catheterization set for children size =4. One 3 lumen catheter set for pediatric central venous cannulation having external diameter of 4 Fr and length 60 mm with side flanges for fixation. Size of three lumen should be 20G, 23G and 23G. Proximal and middle lumen should have flow rate of maximum up to 6.5 ml/min and priming volume of 0.11 ml. Distal lumen should have flow rate of maximum up to 13 ml/min and priming volume of 0.12 ml It should come with a introducer sheath having the following contentsa. One 21 G introducer needle length 38 mmb. One 22 G introducer needle length 25 mmc.one soft tip nitinol or stainless steel or equivalent guide wire of diameterd. One 5 Fr dilator length 60 mme. One 5 ml syringef. Two extra flanges for fixation g. One scalpel # 11 blade 46 Sterile disposable stainless steel SKIN GRAFTING BLADE compatible with Humby/Braithwaite skin grafting handle. 47 4.5 FR Double LUMEN CVC catheter with 60mm. Double-lumen polyurethane central venous catheter inserted by seldinger technique, Radio opaque material for catheter, The user should be able to choose from 2 type of introducer, i.e. needle or I.V. cannula, Latex free, The central venous catheter set should Contain: 1 double-lumen polyurethane 3.5/4.5 Fr catheter, 1 short I.V. cannula, 1 introducer needle, 1 kink resistant guidewire with soft flexible tip, dilator with cylindrical /pencil point tip, 1 secondary fixation wing, 2 injection Caps, 1 scalpel, 1.5 ml syringe4.5 FR-50% , 3.5 FR-50% 48 4 FR Double LUMEN CVC catheter with 60mm. Double-lumen polyurethane central venous catheter inserted by seldinger technique, Radio opaque material for catheter, The user should be able to choose from 2 type of introducer, i.e. needle or I.V. cannula, Latex free, The central venous catheter set should Contain: 1 double-lumen polyurethane 4 Fr catheter, 1 short I.V. cannula, 1 introducer needle, 1 kink resistant guidewire with soft flexible tip, dilator with cylindrical /pencil point tip, 1 secondary fixation wing, 2 injection Caps, 1 scalpel, 1.5 ml syringe 49 Double Lumen Dialysis Femoral Catheter Size - 20cm, 10.0-12 F (Straight/Curved) 50 Dual Lumen Peripherally Inserted Central Catheter, Size – 3.50 to 4.0 F (1.80mm OD) x 55 cm, with internal stiffening stylet/T lock assembly 51 Endoscopic Ultrasound Fine Needle Biopsy (FNB) Device Needle, Size 19G 52 Endoscopic Ultrasound Fine Needle Biopsy (FNB) Device Needle, Size 22G 53 Disposable sterile hypodermic needle with safety shield 18Gfor single use. N Size 18G x 1.5” (1.2x38mm). Made up of stainless steel with puncture protective plastic needle cap. 54 Disposable sterile hypodermic needle with safety shield 23Gfor single use. N Size 23G x 1.5”. Made up of stainless steel with puncture protective plastic needle cap. 55 Triple lumen Central venous catheterization set for children size =3. One 3 lumen catheter set for pediatric central venous cannulation having external diameter of 3 Fr (1.05 mm) and length 60 mm with side flanges for fixation. Proximal and distal lumen should have flow rate of maximum up to 4.4 ml/min and priming volume of 0.09 ml. It should come with a introducer sheath having the following contentsa. One 21 G introducer needle length 38 mmb. One 24 G introducer needle length 19 mmc. One soft tip nitinol or stainless steel or equivalent guide wire of diameter 0.3 mm and length 500 mmd. One 3 Fr dilator length 50 mme. One 3 Fr dilator length 30 mmf. One 5 ml syringeg. Two extra flanges for fixation h. One scalpel # 11 blade 56 Triple lumen Central venous catheterization set for children size =4.5. One 3 lumen catheter set for pediatric central venous cannulation having external diameter of 4.5 Fr (1.5 mm) and length 60 mm with side flanges for fixation. Size of three lumen should be 20G, 23G and 23G. Proximal and middle lumen should have flow rate of maximum up to 6.5 ml/min and priming volume of 0.11 ml. Distal lumen should have flow rate of maximum up to 13 ml/min and priming volume of 0.12 ml It should come with a introducer sheath having the following contentsa. One 21 G introducer needle length 38 mmb. One 22 G introducer needle length 25 mmc. One soft tip nitinol guide wire of diameter 0.46 mm and length 300 mmd. One 5 Fr dilator length 60 mme. One 5 ml syringef. Two extra flanges for fixation g. One scalpel # 11 blade 57 Venous extension tubing with volume capacity of 2ml and length of 1 meter for infusion of IV drugs with three way attatched on one side 58 Ventriculoperitoneal shunt low pressure with 2, 3 and 4 ball valve. Ventricular end with Tantalum tip. Regulating valve contains stainless steel sleeve and balls and a sapphire ball. 59 Ventriculoperitoneal shunt medium pressure with 2, 3 and 4 ball valve. Ventricular end with Tantalum tip. Regulating valve contains stainless steel sleeve and balls and a sapphire ball. 60 Vitrectomy cutter 20 Gauge, 23 Gauge, 25 Gauge (It should be compatible with existing Vitrectomy Machines) 61 Echogenic needle for USG Size - 15cm, 20 G 62 Insulated needles for Peripheral Nerve Stimulation Size - 15cm, 21 / 22 G 63 Sterile Eye pads Size: 2-4 Inches (Diameter) 64 High Flux Dialyzer for Heamodialysis, Surface area 1 m²to 1.4m² made of Polysulphone/Polyether sulphone 65 High Flux Dialyzer for Heamodialysis, Surface area 1.5 m²to 1.8 m² made of Polysulphone/Polyether sulphone

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 27-03-2026 Fresh Critical date Date 17-04-2026
2 10-03-2026 Critical Dates Extension Date 02-04-2026
3 10-03-2026 Critical Dates Extension Date 02-04-2026
4 05-03-2026 New Critical Dates Date 20-03-2026
5 05-03-2026 New Critical Dates Date 20-03-2026
6 05-03-2026 New Critical Dates Date 20-03-2026
7 24-02-2026 Fresh Critical Dates Date 13-03-2026
8 24-02-2026 Fresh Critical Dates Date 13-03-2026
9 24-02-2026 Fresh Critical Dates Date 13-03-2026
10 24-02-2026 Fresh Critical Dates Date 13-03-2026
11 20-02-2026 Critical Dates Revised Date 27-02-2026
12 20-02-2026 Critical Dates Revised Date 27-02-2026
13 20-02-2026 Critical Dates Revised Date 27-02-2026
14 20-02-2026 Critical Dates Revised Date 27-02-2026
15 13-02-2026 Updated Critical Dates Date 27-02-2026
16 13-02-2026 Updated Critical Dates Date 27-02-2026
17 13-02-2026 Updated Critical Dates Date 27-02-2026
18 13-02-2026 Updated Critical Dates Date 27-02-2026
19 06-02-2026 Critical Dates Updates Date 20-02-2026
20 06-02-2026 Critical Dates Updates Date 20-02-2026
21 06-02-2026 Critical Dates Updates Date 20-02-2026
22 06-02-2026 Critical Dates Updates Date 20-02-2026
23 30-01-2026 Critical Dates Updated Date 13-02-2026
24 30-01-2026 Critical Dates Updated Date 13-02-2026
25 30-01-2026 Critical Dates Updated Date 13-02-2026
26 30-01-2026 Critical Dates Updated Date 13-02-2026
27 21-01-2026 Revised Critical Dates Update Date 06-02-2026
28 21-01-2026 Revised Critical Dates Update Date 06-02-2026
29 21-01-2026 Revised Critical Dates Update Date 06-02-2026
30 21-01-2026 Revised Critical Dates Update Date 06-02-2026
31 09-01-2026 Critical Dates Update Date 28-01-2026
32 09-01-2026 Critical Dates Update Date 28-01-2026
33 09-01-2026 Critical Dates Update Date 28-01-2026
34 09-01-2026 Critical Dates Update Date 28-01-2026
35 02-01-2026 Fresh Critical dates Date 16-01-2026
36 02-01-2026 Fresh Critical dates Date 16-01-2026
37 02-01-2026 Fresh Critical dates Date 16-01-2026
38 02-01-2026 Fresh Critical dates Date 16-01-2026
39 24-12-2025 CRITICAL DATES REVISED Date 09-01-2026
40 24-12-2025 CRITICAL DATES REVISED Date 09-01-2026
41 24-12-2025 CRITICAL DATES REVISED Date 09-01-2026
42 24-12-2025 CRITICAL DATES REVISED Date 09-01-2026
43 19-12-2025 changed critical dates Date 02-01-2026
44 19-12-2025 changed critical dates Date 02-01-2026
45 19-12-2025 changed critical dates Date 02-01-2026
46 19-12-2025 changed critical dates Date 02-01-2026
47 12-12-2025 changes in Critical Dates Date 26-12-2025
48 12-12-2025 changes in Critical Dates Date 26-12-2025
49 12-12-2025 changes in Critical Dates Date 26-12-2025
50 12-12-2025 changes in Critical Dates Date 26-12-2025
51 05-12-2025 Critical Dates Date 19-12-2025
52 05-12-2025 Critical Dates Date 19-12-2025
53 05-12-2025 Critical Dates Date 19-12-2025
54 05-12-2025 Critical Dates Date 19-12-2025
55 28-11-2025 Critical Dates changes Date 12-12-2025
56 28-11-2025 Critical Dates changes Date 12-12-2025
57 28-11-2025 Critical Dates changes Date 12-12-2025
58 28-11-2025 Critical Dates changes Date 12-12-2025
59 21-11-2025 Changes in the Critical Dates Date 05-12-2025
60 21-11-2025 Changes in the Critical Dates Date 05-12-2025
61 21-11-2025 Changes in the Critical Dates Date 05-12-2025
62 21-11-2025 Changes in the Critical Dates Date 05-12-2025
63 07-11-2025 Changes in Critical Dates and Prebid Meeting Date 27-11-2025
64 07-11-2025 Changes in Critical Dates and Prebid Meeting Date 27-11-2025
65 07-11-2025 Changes in Critical Dates and Prebid Meeting Date 27-11-2025
66 07-11-2025 Changes in Critical Dates and Prebid Meeting Date 27-11-2025

Key Dates

Publish Date 10-03-2026
Last Date of Bid Submission 02-04-2026
Tender Opening Date 09-04-2026

Contact Information

Company Name Municipal Corporation Of Greater Mumbai
Contact Person Deputy Dean, CPD
Address 566, N M Joshi Marg, Office of Dy. Dean (CPD), Medicine Tender Section, Central Purchase Department, Byculla (W), Mumbai- 400 011.

BOQ Items

Name of Work: Sch VIII (Supply of Needle & Syringes)
Sl. No. Item Description
1Sch VIII (Supply of Needle & Syringes)
2Disposable needle sterile Length 1/2\" Guage – 25
3Suture needle, half circle triangular Nos. 2 to 20 (Cutting)
4Insulated needle for use with peripheral nerve stimulator 22G x 2\" x 50 mm.
5Insulated needle for use with peripheral nerve stimulator22G x 35 mm.
6Insulated needle for use with peripheral nerve stimulator 24G x 1\"x 25 mm.
7Echogent needles for USG guided peripheral nerve blocks 20G / 21G x 100 mm.
8Echogent needles for USGguided peripheral nerve blocks 22G x 50 mm.
9Epidural needles 16 & 18 guage 7.5cm to 11cm (Disposable)
10Epidural needles (long length) 18G (more than 100 mm. length)
11Sterile Disposable Lancet Size 28-32 (Plastic Lancet Needle Type)
12Sterile disposable Hypodermic plastic “syringe 20cc, CN.” With Leur Lock
13Hypodermic Syringes,Disposable sterile, sterile pack,with/withoutLeur Lock, hub 1ml syringe with marking at 0.1 ml
14Asepto Syringe 100 ml ofheavy plastic barrel and rubber bulb with marking.
15Bag Arm Rubber with cover for B.P. apparatus, adult size VELCRO.Rubber bag size 13 x 23 cms.
16Keratome, Size – 2.8 MM, Type-Regular(Ophthalmic), Angle-45 Degrees, Bevel type- Bevel up (pointed)Blade-Stainless steel/Carbon steel,Handle- Polycarbonate, use- Disposable Single Use
17MVR, Gauge – 23G type-Regular(Ophthalmic), Blade-Stainless steel Handle- Polycarbonate, use- single Disposable use
18Triple lumen catheter 7.5fr with 14G distal lumen, length-15cm. Kit contain 1 Teflon-coated “J” Nitinol guidewire particularly kink-resistant with guide-Advancer. 1 dilator, 10cm long, 3 injection caps, 3 clamps,1 supplementary fixation wing,1 scalpel, 1 syringe 5 ml, 1 adaptor for pressure transducer, 1 puncture needle 18G, 70mm long with a pre-connected valve to aviod air embolism and blood loss, 18g short IV cannula
19Double Lumen Subclavian/ Jugular Catheter Kit (Adult)PTFE (Teflon) Cannula Curved OD 2.7/D 11.5Fr-12fr/CHX5.3in. (3.8 mm x 13.5 cm) 6 side holes silicon tube s “clamping extension, clamp” “Luer Lock” \"Y\" “connector” with protective caps “Size 12.5, 15 with guide wire” “introducer needle, dialator”
203FR Double LUMEN CVC catheter with 60mm Double-lumen polyurethane central venous catheter inserted by seldinger technique, Radio opaque material for catheter, The user should be able to choose from 2 type of introducer, i.e.needle 23G or I.V. cannula 22G, Latex free, The central venous catheter set should Contain: 1 double-lumen polyurethane 3Fr catheter, 1 short I.V. cannula 22G, 1 introducer needle 23G, 1 kink resistant guidewire with soft flexible tip, dilator with cylindrical /pencil point tip, 1 secondary fixation wing, 2 injection Caps, 1 scalpel, 1.5 ml syringe
21Peripherally placedRadiopaque central Single Lumen Catheter. Guage 14/16 (100%) (Needles Size/Catheter Size) Length - 55cm - 70cm
22Peripherally placedRadiopaque central Single Lumen Catheter. Guage 18/20 (100%) (Needles Size/Catheter Size) Length30cm - 45cm
23Fully radiopaque PUR catheter 16G for femoral artery centimeter Marking from 5-15cm, Winged hub forskin fixation, supple distal tip. Kit should Contain 1 PUR catheter with XRO lines,1 puncture needle, 1 “J” guidewire with Wishbone-type guidewire advancer, 1 dilator
24Radial/femoral arterial PE catheter with antikinking collar & fixation wings,straight guide wire, introducer needle.Catherter size G- 18, Length 10cm
25Radial/femoral arterial PE catheter 20G, 8cm Puncture needle is fitted with a visualization chamber allowing to confirm that the vessel punctured is an artery (pulsatile movement of the blood). The needle is also fitted with a silicone bloodless system valveto avoid loss of blood during vessel puncture and a funnel hub to facilitate the insertion of the guidewire
26Peripherally inserted central catheter with guide wire with peelable cannula, made of polyurethane, non-toxic, with radio opaque line throughout the catheter with marking every cm with leurconnector at proximal end of cathetereach packed in sterile peel able pouch.Size - 28G, 1 Fr, 20 cm
27Peripherally inserted central catheter with guide wire with peelable cannula, made of polyurethane, non-toxic, with radio opaque line throughout the catheter with marking every cm with leurconnector at proximal end of cathetereach packed in sterile peel able pouch.Size - 24 G, 2 Fr, 30 cm
28Umbilical catheter, single lumen, made of non-toxic, medical grade PVC with smooth round distal tip with radio opaque line throughtout the tube with marking every cm with luer connector at proximal end of catheter each packed in sterile peel able pouch. Size - 3.5 Fr, 30 cm
29Umbilical catheter, single lumen, made of non-toxic, medical grade PVC with smooth round distal tip with radio opaque line throughtout the tube with marking every cm with luer connector at proximal end of catheter each packed in sterile peel able pouch. Size - 4 Fr, 30 cms
30Umbilical catheter, single lumen, made of non-toxic, medical grade PVC with smooth round distal tip with radio opaque line throughtout the tube with marking every cm with luer connector at proximal end of catheter each packed in sterile peel able pouch. Size - 5 Fr, 40 cms
31Straight cannulas with soft tip for vitrectomy gauge -23G, type-Retinal Cannula, Overall length-50 MM,Shaft pattern-Straight, Tip Type-Silicone Tube
32Catheter continuous peripheral nerve block catheter set 18G x 4 3/8 \" (1.3 x 100mm OR 110 mm.) (Needle) 20G (0.85 x 1000 mm.) (Catheter)
33Elastomeric pumps with multirate “1, 2, 3 ml / hr.” Total Valume 100 ml or above
34Elastomeric pumps with multirate “2, 3, 5 ml / hr.”Total Volume 300 ml or above
35Elastomeric pumps with multirate “5, 7, 12 ml / hr.” Total Volume 300 ml or above
36Epidural Catheters with “Filter.0.2µm (Micro meter), flat Sterile” Pack with marking clear cathetar with lateral eyes “at the tip, Luer Lock twist” connector or euivalent Cathetar guide/introducer Catheter Size – 16G
37Epidural Catheters with “Filter. 0.2µm (Micro meter), flat Sterile” Pack with marking clear cathetar with lateral eyes “at the tip, Luer Lock twist” connector or euivalent Cathetar guide/introducer Catheter Size – 18G
38Combined Spinal Epidural Needles Spinal epidural set pencilpoint/ Lancet Disposable Spinal needle,sterile pack, 25G-27G/16G-18G Luer lock & transperant hub, Tuohy needle length = 7.5 to 11cms.Spinal needle protrusion by 11 - 14mm with epidural Catheter, filter,Loss of resistancesyringe.
39Complete Epidural Set (Disposable).Epidural needle, catheter filter & Syringe, Tuohy needle, Catheter with guide & lateral eyes marking gradation at 50-150mm at 10mm & at 200mm. Tuohy needle marking At least 3cms from tip & later on every 1 cm. Filter0.2µm (Micro meter), flat Loss of resistance syringe 10cc. Guage 16 Length75mm – 110mm
40Complete Epidural Set (Disposable). Epidural needle, catheter filter & Syringe, Tuohy needle,Catheter with guide & lateral eyes marking gradation at 50-150mm at 10mm & at 200mm. Tuohy or eqivalent needle marking at least 3cms from tip & later on every 1 cm. Filter 0.2µm (Micro meter) ,flat Loss of resistance syringe7 to 10cc.Marking Guage 18, Length 75mm - 110mm
41Complete Epidural Set (Disposable). Epidural needle, catheter (22G-40cm) filter & Syringe, Tuohy or equivalent needle,Catheter with guide & lateral eyes marking gradation at 50-150mm at 10mm & at 200mm.Tuohy needle marking at every 1 cm from Tip& later on every 1 cm. Filter 0.2µm (Micro meter),flat Loss of resistance syringe 7 to 10cc. MarkingGuage 19,Length 50mm
42Complete Epidural Set (Disposable). Epidural needle, catheter filter & Syringe, Tuohy or eqivalent needle,Catheter with guide & lateral eyes marking gradation at 50-150mm at 10mm & at 200mm.Tuohy needle marking at every 1 cm from Tip& later on every 1 cm. Filter 0.2µm (Micro meter), flat Loss of resistance syringe 7 to 10cc.MarkingGuage20, Length 50 mm
43Central venous catheter Size - 14/16 cm
44Sterile disposable hypodermic plastic syringes: 100ccC.N.with Leur lock
45Triple lumen Central venous catheterization set for children size =4. One 3 lumen catheter set for pediatric central venous cannulation having external diameter of 4 Fr and length 60 mm with side flanges for fixation. Size of three lumen should be 20G, 23G and 23G. Proximal and middle lumen should have flow rate of maximum up to 6.5 ml/min and priming volume of 0.11 ml. Distal lumen should have flow rate of maximum up to 13 ml/min and priming volume of 0.12 ml It should come with a introducer sheath having the following contentsa. One 21 G introducer needle length 38 mmb. One 22 G introducer needle length 25 mmc.one soft tip nitinol or stainless steel or equivalent guide wire of diameterd. One 5 Fr dilator length 60 mme. One 5 ml syringef. Two extra flanges for fixation g. One scalpel # 11 blade
46Sterile disposable stainless steel SKIN GRAFTING BLADE compatible with Humby/Braithwaite skin grafting handle.
474.5 FR Double LUMEN CVC catheter with 60mm. Double-lumen polyurethane central venous catheter inserted by seldinger technique, Radio opaque material for catheter, The user should be able to choose from 2 type of introducer, i.e. needle or I.V. cannula, Latex free, The central venous catheter set should Contain: 1 double-lumen polyurethane 3.5/4.5 Fr catheter, 1 short I.V. cannula, 1 introducer needle, 1 kink resistant guidewire with soft flexible tip, dilator with cylindrical /pencil point tip, 1 secondary fixation wing, 2 injection Caps, 1 scalpel, 1.5 ml syringe4.5 FR-50% , 3.5 FR-50%
484 FR Double LUMEN CVC catheter with 60mm. Double-lumen polyurethane central venous catheter inserted by seldinger technique, Radio opaque material for catheter, The user should be able to choose from 2 type of introducer, i.e. needle or I.V. cannula, Latex free, The central venous catheter set should Contain: 1 double-lumen polyurethane 4 Fr catheter, 1 short I.V. cannula, 1 introducer needle, 1 kink resistant guidewire with soft flexible tip, dilator with cylindrical /pencil point tip, 1 secondary fixation wing, 2 injection Caps, 1 scalpel, 1.5 ml syringe
49Double Lumen Dialysis Femoral Catheter Size - 20cm, 10.0-12 F (Straight/Curved)
50Dual Lumen Peripherally Inserted Central Catheter, Size – 3.50 to 4.0 F (1.80mm OD) x 55 cm, with internal stiffening stylet/T lock assembly
51Endoscopic Ultrasound Fine Needle Biopsy (FNB) Device Needle, Size 19G
52Endoscopic Ultrasound Fine Needle Biopsy (FNB) Device Needle, Size 22G
53Disposable sterile hypodermic needle with safety shield 18Gfor single use. N Size 18G x 1.5” (1.2x38mm). Made up of stainless steel with puncture protective plastic needle cap.
54Disposable sterile hypodermic needle with safety shield 23Gfor single use. N Size 23G x 1.5”. Made up of stainless steel with puncture protective plastic needle cap.
55Triple lumen Central venous catheterization set for children size =3. One 3 lumen catheter set for pediatric central venous cannulation having external diameter of 3 Fr (1.05 mm) and length 60 mm with side flanges for fixation. Proximal and distal lumen should have flow rate of maximum up to 4.4 ml/min and priming volume of 0.09 ml. It should come with a introducer sheath having the following contentsa. One 21 G introducer needle length 38 mmb. One 24 G introducer needle length 19 mmc. One soft tip nitinol or stainless steel or equivalent guide wire of diameter 0.3 mm and length 500 mmd. One 3 Fr dilator length 50 mme. One 3 Fr dilator length 30 mmf. One 5 ml syringeg. Two extra flanges for fixation h. One scalpel # 11 blade
56Triple lumen Central venous catheterization set for children size =4.5. One 3 lumen catheter set for pediatric central venous cannulation having external diameter of 4.5 Fr (1.5 mm) and length 60 mm with side flanges for fixation. Size of three lumen should be 20G, 23G and 23G. Proximal and middle lumen should have flow rate of maximum up to 6.5 ml/min and priming volume of 0.11 ml. Distal lumen should have flow rate of maximum up to 13 ml/min and priming volume of 0.12 ml It should come with a introducer sheath having the following contentsa. One 21 G introducer needle length 38 mmb. One 22 G introducer needle length 25 mmc. One soft tip nitinol guide wire of diameter 0.46 mm and length 300 mmd. One 5 Fr dilator length 60 mme. One 5 ml syringef. Two extra flanges for fixation g. One scalpel # 11 blade
57Venous extension tubing with volume capacity of 2ml and length of 1 meter for infusion of IV drugs with three way attatched on one side
58Ventriculoperitoneal shunt low pressure with 2, 3 and 4 ball valve. Ventricular end with Tantalum tip. Regulating valve contains stainless steel sleeve and balls and a sapphire ball.
59Ventriculoperitoneal shunt medium pressure with 2, 3 and 4 ball valve. Ventricular end with Tantalum tip. Regulating valve contains stainless steel sleeve and balls and a sapphire ball.
60Vitrectomy cutter 20 Gauge, 23 Gauge, 25 Gauge (It should be compatible with existing Vitrectomy Machines)
61Echogenic needle for USG Size - 15cm, 20 G
62Insulated needles for Peripheral Nerve Stimulation Size - 15cm, 21 / 22 G
63Sterile Eye pads Size: 2-4 Inches (Diameter)
64High Flux Dialyzer for Heamodialysis, Surface area 1 m²to 1.4m² made of Polysulphone/Polyether sulphone
65High Flux Dialyzer for Heamodialysis, Surface area 1.5 m²to 1.8 m² made of Polysulphone/Polyether sulphone

Other Detail

Information Source https://mahatenders.gov.in
Download FileName File Description File Size
Download Tendernotice_1.pdf Tender Documents 0 KB
Download 0c8c180a-efe3-4a67-8cfd-07a39847b571.html Tender Documents 0 KB
Download BOQ_2138117.xls Tender Documents 0 KB
Download SCH8MANUALmerged.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.