}

Tender For Rejuvenation And Repair Work Of Residencial Building Type A5 Of Sharda Sahayak Khand 51, Pratapgarh. - Dismantling Existing Plaster Including Disposal Of Refuse As Direction By Engineer-In-Charge With A Distance Of 60 M. 2 Dismantling 1:4:8 L, pratapgarh-Uttar Pradesh

Tender Notice

52092878
Tender For Rejuvenation And Repair Work Of Residencial Building Type A5 Of Sharda Sahayak Khand 51, Pratapgarh. - Dismantling Existing Plaster Including Disposal Of Refuse As Direction By Engineer-In-Charge With A Distance Of 60 M. 2 Dismantling 1:4:8 L
Tender
Indian
Uttar Pradesh
Pratapgarh
07-11-2025

Tender Details

Tender For Rejuvenation And Repair Work Of Residencial Building Type A5 Of Sharda Sahayak Khand 51, Pratapgarh. - Dismantling existing plaster including disposal of refuse as direction by Engineer-in-charge with a distance of 60 M. 2 Dismantling 1:4:8 lime or cement concrete 3 Dismantling R.B. Workincluding stacking of dismantled materials as directionwithin a distance of 60M.as directed by Engineer-in-charge 4 Dismantling lime or cement brick work including stacking of dismantled materials with indistance of 60M.as direction by Engineer-in-charge 5 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 6 Suspended floors, roofs, landings, balconies and access platform., Staircase mid landing 7 Edges of slabs & breaks in floors & walls 8 Extra for additional height in centering, shuttering where ever required with adequate bracing,propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landings, beams and balconies (Plan area to be measured) 9 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars@100kg/cum 10 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work (RCC), using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately).All works above plinth level upto floor V levelConcrete of M25 grade with minium cement concrete of 330 kg/cum 11 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp,of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surfacehacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box bymeans of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of12 mm dia M.S. bar bent to shape as per standard drawing. 12 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 13 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 coarse sand) 14 6 mm cement plaster of mix :1:3 (1 cement: 3 fine sand) 15 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification.Two or more coats on new work 16 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 17 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required(b) Group B 18 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed mediam class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 19 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. b) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 20 Installation, Testing and Commissioning of pre-wired fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling / wall, including connections with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 21 LEDDownlighter(SMD Type)(Systemlumenefficacy≥ 105 < 120 lm/Watt )Supplying, installation, Testing & Commissioning ofLED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322withdriveraspertherequirementwithDriverefficiency>85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 degto40degcentigrade,internalsurgeprotectionof2.5KV withShort&Opencircuit protection ,THD < 10% , P. F.≥0.95,IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%),lifetime(LED,Driver&electricalcircuitary),ofminimum50000 Burning Hours with70% of initial Lumenmaintained tilllife ends , CCT 3000°K /4000°K/ 5700°K / 6000°K / 6500°K (AsperANSIBin), SDCM(StandardDeviationColorMatching)<3, Maximum power consumptionshouldnotmorethan the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Completeinallrespecti/cconnectionswith1.5sqmmFRLS, PVC insulated copper conductor single core cable and earthing etc. as requiredwith Minimum 5 year OEM warranty.System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test reportfromNABLlab forall testingrequiredforLED fixtures as per BISshall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermalmanagement:heatsinkofaluminumhousing such that LED junction temperature shall not rise above 90°CPowdercoateddiecast/Extruded aluminum Body including trima) 12 - 15 Watt

Key Value

Document Fees
INR 766 /-
Tender Value
INR 6.50 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail