Tender For Provision Of Squad Post At Jat Regimental Centre Bareilly Cantt Under Ge (West) Bareilly; 2 Construction of toilet block at short range site complete all as specified and as shown of drawing 3 Construction of toilet block at IT area site complete all as specified and as shown of drawing 4 Construction of toilet block at Mooltan Coy TRG Ground site complete all as specified and as shown of drawing 5 Construction of Squad post 6 Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out soft/loose soil complete all as specified and directed. 7 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes,pier holes,in soft/loose soil n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/ loose soil complete all as specified and directed. 8 M&L for PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in in foundations, filling and mass concrete complete all as specified and directed. 9 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.complete all as specified and directed. 10 Removing excavated material (soil) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. 11 M&L for RCC M-25 (design mix) (using 20 mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 12 Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, rough finished surfaces of concrete complete all as specified and directed . 13 M&L for RCC M-25 (design mix) (using 20 mm graded stone aggregate) as in Columns, pillars, piers, posts and struts complete all as specified and directed. 14 Formwork to sides of rough finished surfaces of concrete pillars, posts, struts, piers, columns and stanchions complete all as specified and directed. 15 M&L for mild steel TMT bars10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 16 M&L for Mild steel bars 5 mm dia and over upto and including 10mm dia stirrups, spacers and binders cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and bindingwith and including mild steel wire(annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 17 M&L for brickwork with fly ash old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed. 18 M&L for 15 mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces and finishing the surface even and smooth without using extra cement complete all as specified and directed. 19 S&F Steel Hollow section truss etc including special shaped washers etc complete using induction butt welded tubes confirming to IS-4923 : 1997 (reaffirmed 2009) grade YST – 310 including a coat of zinc chrome primer before fabrication complete all as specified and directed. Note : - (i) Please refer sketch P for fabrication and eraction of truss. (ii) Truss should be designed for wind speed as applicable at Bareilly Station. 20 M & L for 125 mm dia bore ms hollow pipe medium grade thickness 4.85 mm for single stainchain, built up of one beam or channel sectionwith gusset plate, caps, bases splices and other connection conforming to IS-1161: 1979 (grade E-250) quality –A complete all as specified. 21 S&F mild steel bolts. purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. Exc 30cm long diameter of neck exc 12 mm but n 20 mm complete all as specified and directed. 22 M&L for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. 23 M&L for pre-painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof ridge to wall, fixed with self tapping screws complete all as specified and directed. 24 M&L for broken stone or boulder Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. 25 S&Ffor 100 mm thick PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in sub base of floor etc complete all as specified and directed. 26 M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base 15 mm thick in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. 27 M&L for granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed. 28 M&L for 75 mm thick PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) and finishing surface even and smooth without using extra cement as in plinth protection etc complete all as specified and directed. 29 M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint over one coat of alkali resistant primer complete all as specified and directed. 30 M&L for preparation of new steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. 31 SCHEDULE A PART II (INTERNAL WATER SUPPLY) for details refer Sch A in pdf folder 32 SCHEDULE A PART III A (INTERNAL ELECTRIC SUPPLY) for details refer pdf folder 33 SCHEDULE A PART III B (INTERNAL ELECTRIC SUPPLY) 34 S&F 9 watt LED bulb, 230 volt, 50 Hz complete all as specified and directed. 35 SCHEDULE A PART IV (EXTERNAL WATER SUPPLY) for details refer pdf folder 36 SCHEDULE A PART V A (EXTERNAL ELECTRIFICATION) for details refer pdf folder 37 SCHEDULE A PART V B (EXTERNAL ELECTRIFICATION) 38 Cutting of floor/ wall/road/ footpath for removal of LT U/G cable of any size/ description and making good the same as per existing specification after relaying the same or new cable complete all as specified and directed. 39 Supply, install, commissioning and testing of outdoor type LT panel board, cubical type, sloping canopy top roof, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 600 mm x 900 mm x 300 mm, CPRI approved with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive offour numbers aluminium bus bar of 200 amps capacity (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland), and two numbers Danger Notice Plate (of size 20 cm x15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle iron 50 x 50 x 6 mm with 450mm legs with PCC complete all as specified and directed by the Engr-in-Charge including supply and fixing of the following accessories :-(a) MCCB with thermal-magnetic release of cap 63 Amp, FP, 50 Hz, 25 KA with spreader terminals - 01 Nos (I/C).(b) MCCB with thermal-magnetic release of cap 63 Amp, FP, 50 Hz, 25 KA with spreader terminals - 01 Nos (O/G).(c) MCB SPN 63 Amps, 240 volts, 50 Hz -1 No(d) Digital Amp Meter with selector switch -1 No(d) Digital Volt Meter with selector switch -1 No(f) LED type indication lamp RYB-1 set.(set of 03)(g) CTs 63/5A - 03 Nos 40 Supply, install, commissioning and testing of outdoor type LT panel board, cubical type, sloping canopy top roof, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 600 mm x 900 mm x 300 mm, CPRI approved with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive offour numbers aluminium bus bar of 200 amps capacity (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland), and two numbers Danger Notice Plate (of size 20 cm x15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle iron 50 x 50 x 6 mm with 450mm legs with PCC complete all as specified and directed by the Engr-in-Charge including supply and fixing of the following accessories :- (a) MCCB with thermal-magnetic release of capacity 40 Amp, FP, 50 Hz, 25 KA with spreader terminals - 01 Nos (I/C).(b) MCB SPN 32 Amps, 240 volts, 50 hz - 12 Nos(c) Digital Amp Meter with selector switch -1 No(d) Digital Volt Meter with selector switch -1 No(e) LED type indication lamp RYB-1 set.(set of 03)(f) CTs 40/5A - 03 Nos 41 Supply, install, commissioning and testing of outdoor type LT panel board, cubical type, sloping canopy top roof, dust and vermin proof, made out of 3.15 mm thick CRCA sheet of size 600 mm x 900 mm x 300 mm, CPRI approved with front and back openable door (with locking arrangement) and making compartment for each MCCB/change over switch separately, duly painted with two coats of powder coated paint over a coat of red oxide zinc chrome primer inclusive offour numbers aluminium bus bar of 200 amps capacity (of adequate length), for three phase and neutral system, fixed over and including 4 nos insulators, pre-wired with PVC insulated stranded copper conductor (of adequate size), all incoming / outgoing connection to be made with copper lugs and copper strips, with provision of cable entry and exit at mid portion of the panel board (with cable gland), and two numbers Danger Notice Plate (of size 20 cm x15 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour, fixed with MS angle iron 50 x 50 x 6 mm with 450mm legs with PCC complete all as specified and directed by the Engr-in-Charge including supply and fixing of the following accessories :-(a) MCCB with thermal-magnetic release of capacity 40 Amp, FP, 50 Hz, 25 KA with spreader terminals - 01 Nos (I/C).(b) Digital Amp Meter with selector switch -1 No(c) Digital Volt Meter with selector switch -1 No(d) LED type indication lamp RYB-1 set.(set of 03)(e) CTs 40/5A - 03 Nos 42 SCHEDULE A PART VI (ROAD/ PATH/ CULVERT) for details refer pdf folder 43 SCHEDULE A PART VII A (SEWAGE DISPOSAL)for details refer pdf folder 44 SCHEDULE A PART VII B (SEWAGE DISPOSAL) 45 M&L for construction of Septic Tank for 25 users including necessary earth work in excavation in any type of Soil, plain cement concrete 1:2:4 type B2 (using 40 mm graded crushed stone aggregate) as in foundation , brick work in cement mortar 1:4, RCC M-25 (design mix) as in slab cover including Cast iron Circular man hole cover, 15 mm thick plaster in cement sand mortar in 1:4 on wall, vent shaft, sludge chamber, formwork to sides and soffits, 150 mm dia SGSW pipe of type SP 1as per IS as inlet & outlet pipes upto 3 m from outer face of wall, CI vent pipe, sludge chamber, RCC baffle wall, returning filling & removal etc, complete all as shown on drawings & as specified. Drg No : HQ CE Northern Zone Drg No.- TD/217 Sht No - 1/7 to 7/7 dated 25/11/1968 Revised on 08/08/1981 and true copy dated on 20 Dec 2004. 46 M&L for construction of soakage well for 2.40 m dia (internal dia) & 3 m effective depth including necessary excavation in earthwork in any type of soil, plain cement concrete 1:3:6 type C2 (using 40 mm graded crushed stone aggregate) as in foundation, brickwork in cement moratar 1:4 in wall & honey combed brick wall, RCC M-25 (design mix) as in slab cover including precast cover slab having 8 mm dia TMT bar reinforced, plain cement concrete band and dwarf wall, formwork to sides and soffits of RCC slab & filling with brick bats loose filling complete all as specified and shown in drawings. Drg No : HQ CE LKO Zone Drg No.- TD/576 Sht No - 1/1 to 1/2 dated 16/06/1989. 47 SCHEDULE A PART VIII (SITE CLEARANCE) for details refer pdf folder