}

Tender For Maintenance / Repair / Replacement Of Internal Electrification And Other Allied E/M & B/R Works In Bso Yard, Mt Ge Office Complex, Old Telephone Line, Officers Mess, Np Line, Ngbm, Ogbm OfficerS Married Accn And Other Connected Area Under Age , pune-Maharashtra

Tender Notice

52090005
Tender For Maintenance / Repair / Replacement Of Internal Electrification And Other Allied E/M & B/R Works In Bso Yard, Mt Ge Office Complex, Old Telephone Line, Officers Mess, Np Line, Ngbm, Ogbm OfficerS Married Accn And Other Connected Area Under Age
Tender
Indian
Maharashtra
Pune
22-11-2025

Tender Details

MAINTENANCE / REPAIR / REPLACEMENT OF INTERNAL ELECTRIFICATION AND OTHER ALLIED E/M & B/R WORKS IN BSO YARD, MT GE OFFICE COMPLEX, OLD TELEPHONE LINE, OFFICERS MESS, NP LINE, NGBM, OGBM OFFICERS MARRIED ACCN AND OTHER CONNECTED AREA UNDER AGE E/M-I OF GE SOUTH PUNE; 1 Labour only for repair / maintenance of internal light fitting of any typelike tube lights / wall bracket light fittings / ceiling lights / bulk head light / mirror lights etc in its position, testing all the components / parts, wiring etc, identifying and taking out the defective components like holders, lamps etc complete all as directed by Engr-in-charge. Note:(i). Attending of one number complaint and make it functional, shall be measured as one job.(ii)Spares like capacitor, lamp holder, connector, connection wire etc. replaced against above mentioned item will be measured & paid for separately as S&F under respective items of BOQ.(iii)The contractors representative will report to concerned JE E/M at 0900hrs daily to collect the list of defects and will submit the completion report on following day before 0900hrs to the JE E/M & Engr-In-Charge. 2 (iv) The contractor shall rectify the defects and make the light fittings functional within 24 hours from the time the list of defective lights is handed over to him / his rep by the concerned JE E/M.In case the light fitting is not made functional for whatsoever reason within the specified time limit, an amount of Rs 100/- per such defective light fitting per day will be recovered from the amount due to him through RAR / Final Bill.The contractor shall engage separate team of technicians / repairerwith helperfor each at AICTS, 64 EME BN and other connected area.(v) The contractor shall maintain proper record of repair / maint in a binded compliant register and complaint slip books duly signed by the user and bringing out the details of spares replaced and get it authenticated from concerned JE E/M on daily basis. The contractor shall put up the maint record register to Engineer-in-charge for inspection every Monday or as and when asked for. (vi) The contractor shall maintain sufficient stock of spares / material required for repair / maintenance of light fittings. 3 S&F of Lamp Holder, insulated body, with back plate for batten fitting include complete all as specified and directed. 4 S&F modular fivestep type fan regulatorup to 120W, 2 modulesuitable for existing modularframe complete all as specified and directed. 5 S&F modular switch 10 amps one way one module complete all as specified and directed. 6 S&F modular switch 10 amps two way one module complete all as specified and directed. 7 S&F modular switch piano type 20 amps one way one module with neon indicatorcomplete all as specified and directed. 8 S&F modular Bell Push 6 Amp amps one way one module with neon indicatorcomplete all as specified and directed. 9 S&F modular Socket, 6A - 2/3 pin,2 module complete all as specified and directed. 10 S&F modular Socket, 6/16A - 2/3 pin, 2 module complete all as specified and directed. 11 S&F of 1 module Blanking plates complete all as specifed and directed by Engr-In-Charge. 12 S & Fof switch piano flush type 5 Amps SP one way complete all as specified and directed 13 S & Fof switch piano flush type 15 Amps SP one way complete all as specified and directed 14 S & F ofmodular switch socket combination 6 Amps flush mounted 2/3 pin, multi purpose, 3 module, complete all as specified and directed 15 S & F ofmodular switch socket combination 16 Amps flush mounted 2/3 pin, multi purpose, 3 module, complete all as specified and directed 16 S & F ofswitch socket combination 5/15 Amps flush mounted3/5 pin multi purpose complete all as specified and directed 17 S & F ofswitch socket combination 5/6 Amps flush mounted3/5 pin multi purpose complete all as specified and directed 18 S&F ofsocket outlet, 5/6 Amps flush mounted2-in-1, 3 pin, complete all as specified and directed 19 S&F ofsocket outlet, 5/15 Amps flush mounted2-in-1, 3/5 pin, complete all as specified and directed 20 S&Ffor ceiling rose, 2 to 3 terminals /PVC / Polycarbonate, isolated body complete all as specified and directed 21 S&F offan regulator (socket type) electronic type, five step, suitable for 1200/1400 mm sweep fan as per the sample provided by the Engr-in-charge. 22 S&F of door bell AC 230 volts single phase ding dong type complete all as specified and directed. 23 S&F bell push, flush type 5 Amps complete all as specified and directed. 24 S & F ofswitch socket combination with box 5/6 Amps surface mounted 5 pin multi purpose complete all as specified and directed 25 S & F ofswitch socket combination with box 6/16 Amps flush mounted3/5 pin multi purpose complete all as specified and directed 26 Taking down carefully aluminium / copper point wiring with surface/ concealed PVC conduit or wooden batten ( light, fan, socket, bell or power ) including sunk in cast iron / pressed steel terminal boxes except fitting such as switches, ceiling roses, lamp holders, sockets, regulators, call bells, light fittings of any sketch etc and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engr-in-Charge. 27 M&L for point wiring with 1.5 sq mm copper conductor FRLSH (multi-stranded) PVC insulated ISI marked unsheathed cable and including surface, Non metallic rigid PVC casing capping double lock type / PVC conduit ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unsheathed FRLSH cable size 1.5 sq mm copper conductor as earth wire to common earth dolly including PVC box, modular cover plate with frame suitable for modular type switches, sockets, fan regulator etc for One light/Fan point controlled by one way switch 6 Amps 240 volts, complete all as specified and directed. 28 All as per item no. 26 above but One 3 pin 6 Amps socket out let point on independent board, complete all as specified and directed 29 All as per item no. 26 above but One 3 pin 6 Amps socket out let point on same board, complete all as specified and directed 30 All as per item no. 26 above but One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sq mm size, complete all as specified and directed 31 All as per item no. 26 above but One light point controlled by Two 2-way switches, complete all as specified and directed 32 M&L for point wiring with 2.5 sq mm copper conductor FRLS (multi-strand) PVC insulated ISI marked unsheathed cable and including surface, Non metallic rigid PVC casing capping double lock type ISI marked not less than 25 mm with all fitting & other accessories and also including PVC insulated ISI marked unsheathed FRLS cable size 2.5 sq mm copper conductor as earth wire to common earth dolly including PVC box , modular cover plate with frame suitable for 15 Amps socket and switch outlet power point independent circuit, complete all as specified and directed. 33 M&L for securingloose wiring and repair to point wiring with including necessary rigid non metallic PVC casing caping double lock type/ PVC conduit ISI marked of size not less than 25 mm inclusive all accessories complete as specified and directed. 34 S&F of flexible conduit pipe ivory grey in colour of dia not less than 25 mm rigid non-metallic, exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc, complete all as specified and directed. 35 M&L for sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 1.5 Sqmm, 1100 Volts grade in and including PVC Conduit /casing capingmedium grade not less than 25 mm complete with conduit accessories and copper cable 1.5 sqmm, FRLSH, continuous earth wirecomplete all as specified and directed.Note:- Two runs of 1.5 Sqmm cable with 01 run of 1.5 Sqmm earth wire along with casing caping / conduit shall be measured as one RM 36 M&L for sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 2.5 Sqmm, 1100 Volts grade in and including PVC Conduit /casing capingmedium grade not less than 25 mm complete with conduit accessories and copper cable 2.5 sqmm continuous earth wirecomplete all as specified and directed.Note:- Two runs of 2.5 Sqmm cable with 01 run of 2.5 Sqmm earth wire along with casing caping / conduit shall be measured as one RM 37 M&L for sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 4 Sqmm, 1100 Volts grade in and including PVC Conduit /casing capingmedium grade not less than 25 mm complete with conduit accessories and copper cable 4 sqmm, FRLSH, continuous earth wirecomplete all as specified and directed.Note:- Two runs of 4 Sqmm cable with 01 run of 4 Sqmm earth wire along with casing caping / conduit shall be measured as one RM 38 M&L for sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 6 Sqmm, 1100 Volts grade in and including PVC Conduit /casing capingmedium grade not less than 25 mm complete with conduit accessories and copper cable 6 sqmm, FRLSH continuous earth wirecomplete all as specified and directed.Note:- Two runs of 6 Sqmm cable with 01 run of 6 Sqmm earth wire along with casing caping / conduit shall be measured as one RM 39 M&L for sub main wiring with two single core PVC insulated FRLSH cables with stranded copper conductors 10 Sqmm, 1100 Volts grade in and including PVC Conduit /casing capingmedium grade not less than 25 mm complete with conduit accessories and copper cable 10 sqmm, FRLSH continuous earth wirecomplete all as specified and directed.Note:- Two runs of 10 Sqmm cable with 01 run of 10 Sqmm earth wire along with casing caping / conduit shall be measured as one RM 40 Taking down carefully sub main wiring of any type and size and making good disturbed surfaces , complete all as specified and directed. 41 S&F 1100 volts grade heavy duty cable 4 Sqmm two core PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1.0 m apart including 4mm suspension wire, one twin core cable flat or circular, complete all as specified and directed. 42 S&F in replacement factory made epoxy powder coated Distribution Board TP & N 4way double door (VTPN MCCB DB ) MCCB as In comer, with metal door (IP-43 protection) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockout semi flush to wall and making good disturbed surface and touch up with the same finishes complete all as specified and directedNote:- MCBs/ MCCBs will be measured and paid separately under respective items of BOQ 43 S&F in replacement MCB DB 12 way SPN double door sheet metal enclosure factory made suitable for MCB DBs 240 volts with 200 amp rated bus bar, neutral & earthing link bar, surface mounting complete including taking down the existing DB of any type & size along with its accessories by removing from existing circuits and re-fixing the new DBs and circuits complete as required at site complete as specified and directed by the Engr-in-Charge.Note - MCBs will be measured & paid separately under respective items of BOQ 44 S&F in replacement MCB DB 8 way SPN double door sheet metal enclosure factory made suitable for MCB DBs 240 volts with 200 amp rated bus bar, neutral & earthing link bar, surface mounting complete including taking down the existing DB of any type & size along with its accessories by removing from existing circuits and re-fixing the new DBs and circuits complete as required at site complete as specified and directed by the Engr-in-Charge.Note - MCBs will be measured & paid separately under respective items of BOQ 45 S&F in replacement MCB DB 4 way SPN double door sheet metal enclosure factory made suitable for MCB DBs 240 volts with 200 amp rated bus bar, neutral & earthing link bar, surface mounting complete including taking down the existing DB of any type & size along with its accessories by removing from existing circuits and re-fixing the new DBs and circuits complete as required at site complete as specified and directed by the Engr-in-Charge.Note - MCBs will be measured & paid separately under respective items of BOQ 46 S&F in replacement MCB DB 2 way SPN single door sheet metal enclosure factory made suitable for MCB DBs 240 volts with 200 amp rated bus bar, neutral & earthing link bar, surface mounting complete including taking down the existing DB of any type & size along with its accessories by removing from existing circuits and re-fixing the new DBs and circuits complete as required at site complete as specified and directed by the Engr-in-Charge.Note - MCBs will be measured & paid separately under respective items of BOQ 47 S&F MCCB with rating of 100 Amps, 415 Volts, 3 pole with 16 kA breaking capacity, thermal magnetic adjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity (Icu), MCCBshould be with suitable spreaders and phase barriers for each terminals complete as specified and directed 48 S&F in repairs MCCB with rating of 63 Amps, 415 Volts, 3 pole with 16 kA breaking capacity, thermal magnetic adjustable of overload & short circuit release as per IS-13947 & IEC 60947-2 & the service short circuit breaking capacity (Ics) should be equal to ultimate breaking capcity (Icu), MCCBshould be with suitable spreaders and phase barriers for each terminals complete as specified and directed 49 S&F in replacement of sheet metal enclosures single pole and neutral with a two pin and earth plug and socket complete incluidng with one single pole MCB 20 Amps, 240 volts with all accessaries etc complete all as directed by Engr-in-charge. 50 S&F in replacement metal clad plug top 3 pin, 20 Amps, 230 volts, ISI marked heavy duty suitable for geyser connection cord complete all as specified and directed. 51 S&F in replacement of neon lamp indicator square / round type including taking down old unserviceable neon lamp complete all as specified and directed. 52 M&L for earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to galvanised earth lead wire 4.0mm diafor earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part-I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC (1:2:4, Type B1) as in Pit and RCC 1:2:4, Type B1 as in cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. and disconnecting and taking down existing Earthing of any description complete all as specified and as directed.Note : GI earth wire and GI protection pipe up to 7.50 m length shall be included in unit quoted rates of this item 53 S&F in replacement heating element of capacity 2 KW of any type and shape suitable for existing 25 ltrs capacity geysers as per sample provided by Engr-in-Charge complete all as directed. 54 S&F in replacement of C Curve MCB SP 6-32 Amps working on 240 volts, 50 Hz 10 KA, complete all as specified and as directed. 55 S&F in replacement of C Curve, MCB SPN, 6-32 Amps working on 240 volts, 50 Hz 10 KA, complete all as specified and as directed. 56 S&F in replacement of C Curve MCB SPN 40-63 Amps working on 240 volts, 50 Hz 10 KA, complete all as specified and as directed. 57 S&F in replacement of C Curve MCB TP 25-63 Amps working on 240 volts, 50 Hz 10 KA, complete all as specified and as directed. 58 S&F in replacement of C Curve MCB TPN 40-100 Amps working on 240 volts, 50 Hz 10 KA, complete all as specified and as directed. 59 Taking down ceiling fan / exhaust fan of any sweep for servicing / repairing / maintenance, opening up, identifying and replacing the defective parts, cleaning, greasing etc, re-assembling and hanging up / re-fixing back at its original position, connecting up and testing complete all as directed.Note:- Cost of spares such as capacitors, bearings etc will be measured and paid for separately under respective Item of BOQ as supply only. 60 Supply only bearing No.6201/6202/6203 or any other No matching to the existing size and suitable for ceiling fan/exhaust fan/wall mounted fan, complete all as specified and directed. Make:- SKF or equivalent 61 Supply only capacitor of 2.5 mfd for ceiling fan / exhaust fan, complete all as specified and directed.Make:Tibcon/Epcos/Havells 62 S&F in replacement of aluminum fan blades suitable for heavy duty exhaust fan of any sweep as per the sample complete all as directed by Engr-in-charge 63 M&L for removing of burnt winding of ceiling fan’s motor of celling fan of size 1200/1400mm sweep, and rewinding of the same with super enamelled copper winding wire of suitable gauge or of matching size to the existing wires including all insulating material such as insulation paper sleeve, tape, varnishing etc. and reassembling, testing, transporting back to site and re-fixing to original position complete all as directed by Engineer-in-charge. 64 All as per item no. 62 above but Exhaust fan of 300 mm sweep, complete all as directed by Engineer-in-charge 65 Dismantling and removing rusted louvers (set of 4) and S&F new mild steel louvers duly painted gray colour synthetic enamel paint suitable for 300mm heavy duty exhaust fan along with four number mounting bracket with bolts, nuts washers etc complete all as directed by Engineer-in-charge 66 Supply and fixing of exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 150m including replacing of plywood as per site requirement, complete all as directed by Engineer-in-chargeNote:- Old Exhaust fan will be deposited in MES store yard by the contractor without any extra cost to the Department. 67 Supply and fixing of exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 200m including replacing of plywood as per site requirement, complete all as directed by Engineer-in-chargeNote:- Old Exhaust fan will be deposited in MES store yard by the contractor without any extra cost to the Department. 68 Supply and fixing of exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 250m including replacing of plywood as per site requirement, complete all as directed by Engineer-in-chargeNote:- Old Exhaust fan will be deposited in MES store yard by the contractor without any extra cost to the Department. 69 Supply and fixing of exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, copper winding of sweep 300m including replacing of plywood as per site requirement, complete all as directed by Engineer-in-chargeNote:- Old Exhaust fan will be deposited in MES store yard by the contractor without any extra cost to the Department. 70 S&F PVC unbreakable surface boxes of size 4x4, complete all as specified and directed 71 S&F PVC unbreakable surface boxes of size 6x6, complete all as specified and directed 72 S&F PVC unbreakable surface boxes of size 4x7, complete all as specified and directed 73 S&F PVC unbreakable surface boxes of size 6x8, complete all as specified and directed 74 S&F PVC unbreakable surface boxes of size 8x10, complete all as specified and directed 75 Taking down carefully and re-fixing geyser of any size / make after doing the necessary repair works with necessary fasteners /clamps and making good any disturbed surface complete all as directed by Engr-in-charge 76 S&F in replacement of thermostat and cutout set electronic type, temperature adjustable from 0-80⁰C suitable for geyser of 25 ltrs capacity, complete all as directed by Engr-in-charge. 77 Disconnecting and taking down existing unserviceable geyser of 25 ltrs capacity of any make / brand, carrying over the same to civil workshop for repairing & welding etc.Opening the geyser and dismantling of all parts and taking out inner tank / container, removing dents and making it to shape including welding / brazing to the leakage portion and S&F filling of new glass wool in between inner tank and out casing of geyser. Re-assembling and carrying back to site the geyser and painting to outer casing of geyser with two coats of superior quality synthetic enameled paint after preparation of surfaces and re-fixing to its original location complete all as directed by Engr-in-charge 78 S&F in replacement of NRV valve of size 15mm dia of Brass complete all as specified and directed. 79 Supply & fix in replacement 15/16 Amps plug top, 3 pin,230 V, ISI marked, suitable for geyser connection cord, complete all as specified and as directed 80 S&F in replacement of white cover plate with frame 2 module, complete all as specified and directed by Engr-in-charge. 81 S&F in replacement of white cover plate with frame 3 module, complete all as specified and directed by Engr-in-charge. 82 S&F in replacement of white cover plate with frame 4 module, complete all as specified and directed by Engr-in-charge. 83 S&F in replacement of white cover plate with frame 6 module, complete all as specified and directed by Engr-in-charge. 84 S&F in replacement of white cover plate with frame 8 module, complete all as specified and directed by Engr-in-charge. 85 S&F in replacement of white cover plate with frame 12 module, complete all as specified and directed by Engr-in-charge. 86 S& F in replacement PVC unbreakable surface boxes suitable for modular switches 1 or 2 module, complete all as specified and directed. 87 S& F in replacement PVC unbreakable surface boxes suitable for modular switches 3 module, complete all as specified and directed. 88 S& F in replacement PVC unbreakable surface boxes suitable for modular switches 4 module, complete all as specified and directed. 89 S& F in replacement PVC unbreakable surface boxes suitable for modular switches 6 module, complete all as specified and directed. 90 S& F in replacement PVC unbreakable surface boxes suitable for modular switches 8 module, complete all as specified and directed. 91 S& F in replacement PVC unbreakable surface boxes suitable for modular switches 12 module, complete all as specified and directed. 92 S&F in replacement of 3mm thick white coloured hylam sheet (bakelite) for mounting switches complete all as directed 93 S&F in replacement of GI pipe bracket of 25 mm dia 1.0 m long bend to shape for street light fitting made out of 25 mm dia GI light grade pipe fixed on pole using suitable FI clamp including necessary new nut, bolt and washer complete all as specified and directed 94 Supply and fixing in repair LED building security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics and should have supporting LM 79 & LM 80 test certificate from Government approved NABL accredited Lab with IP 65/66 protection complete all as specified and directed by Engr-in-Charge 95 S&F in replacement of1x10watt,230V , / Min 100 lms/w surface and wall mounted LED batten suitable for mirror light with Aluminium housing, glare free and integrated electronic driverincluding connecting up with twin core twisted flexible copper conductor cable from ceiling rose all as specified and directed by Engr-In- Charge 96 Supply and fixing in replacement round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light minimum 100 lms/w complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed by Engr-in-charge 97 S&F in replacementofrecess type LED ceiling lights 15 W LEDwith ceiling cut out of Ø 170 mm, 6000K recess mounted down lighter with separate replaceable electronic driver including connecting with twin core wire, including cutting the existing false ceiling dia to the required size and also matching to the adjacent false ceiling surfaces carefully complete all as specified and directed. Make:- Luker /Havells / Crompton 98 Supply & fixing in replacement of LED fixture 18 watt surface mounted ceiling light 5700K with diffuser to give glare free light of size 300x300 mm, Min 100 lms/w powder coated CRCA housing with compatible driver complete all as specified & directed by Engr-in-Charge 99 Supply & fix in replacement of LED fixture 36 watt surface mounted ceiling light 5700K with diffuser to give glare free light, Min 100 lms/w powder coated CRCA housing with compatible driver complete all as specified & directed by Engr-in-Charge 100 M&L for painting of ceiling fan of any sweep with two coats of synthetic enamel paint by rubbing / removing the old paint carefully without any damage to the fan or fan blades etc complete all as directed by Engineer-in-charge. 101 M&L for painting of exhaust fan of any sweep with two coats of synthetic enamel paint by rubbing / removing the old paint carefully without any damage to the fan or fan blades etc complete all as directed by Engineer-in-charge. 102 Taking down cement plaster (From any height) from old brick / stone masonry walls etc. including racking out joints, hacking for keys and scrubbing down with water complete all as specified and directed. 103 M & L 15 mm thick rendering in cement mortar 1:6 on fair face of brick work or concrete surfaces, surface finished even and smooth with out using extra cement, complete all as specified and as directed. 104 M&L for preparation of old plastered / decorated wall surfaces by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and appyling one coat of distemper oil emulsion including necessary scafolding and safety measures as required at site complete as specified and as directed by Engr-in-Charge. 105 S&F in replacement Brass chrominum plated connection 15 mm dia 600 mm long (heavy duty) with 2 Nos brass chrominum plated nuts and washer suitable for geysers of 25 ltr capacity complete all as specified and directed by Engr-in-Charge. 106 S&F in repairs FRP, water proof, weather proof, sock proof single phase electric meter box of size 250x250x155 mm with front side glass window, surface mounting type with connected accessories complete all as specified and directed by Engr-in-Charge. 107 S&F in repair FRP, water proof, weather proof, sock proof three phase electric meter box of size min 400x300x200 mm with front side glass window, surface mounting type with connected accessories complete all as specified and directed by Engr-in-Charge. 108 Supply and fixing LED light fitting 1x16 Watt flame proof, CMRI certified recommended for gas/ vapour group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminium hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-Charge. 109 Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. 110 M&L for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed by Engr-in-Charge. 111 Supply and fixing in replacement 2x2 feet, 36 Watts, white powder coated CRCA housing recessed type with in built PIR sensor can detect motion from 5 mtr heightwith high efficiency PMMA diffuser soft glare free light,5700 K, min 100 lms/w complete with drivers, for roof ceiling including connecting up with three core flexible copperconductor cable of suitable size complete all as specified and directed by Engr-in-charge. 112 Supply and fixing in replacement 2x2 feet, white powder coated CRCA housing recessed type with optional pre-set colour temperature or manual adjustments to any CCT in the productivity range 3000K-6500K along with dimming range 10%-100% controlling of the luminaire is possible by wirelessly with app based control & remote control including drivers and remote, for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as speciifed and directed by Engr-in-charge. 113 S&F in replacement Decorative, wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 9 W LED lamp B22 base including 01x9 W LED bulb (warm white) and connecting up with twin core twisted flexible copper conductor cable from ceiling rose complete all as specified and directed by Engr-in-Charge. 114 S&F in replacement 1x12 watt, 230V surface mounted LED downlight , Min 100 lms/w Aesthetically designed ultra sleek downlighters with die cast alumimium housing with high efficiency,CW/WW lightincluding connecting up with twin core twisted flexible copper condctor cable from ceiling rosE complete all as specified and directed by Engr-in-Charge. 115 Supply and fixing in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light, Min 100 lms/wcomplete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in-Charge. 116 Supply and fix in replacement of exhaust fan, steel bodyAC single Phase, 230V of size 300msweep with blades, and frame etc. complete all as specified and directed. 117 S&F in repair for stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed 118 S&F in replacement of LED tube 20 W, 4 feet length, 6500 k, 120 lms/watt glare free, the LED fitting shall be comply with L70810 Voltage range, PH>0.95, THD<10% and should have supporting LM 79 & LM 80 test certificate from Government approved NABL accredited Lab complete all as specified and directed by Engr-in-Charge

Key Value

Document Fees
INR 500 /-
Tender Value
INR 42.21 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail