}

Tender For Repair Maintenance Of Damaged Wornout Ci Gi Pipe Lines And Allied Works For Raksha Vihar Area Under Gei R And D Kanpur, kanpur-Uttar Pradesh

Tender Notice

52089580
Tender For Repair Maintenance Of Damaged Wornout Ci Gi Pipe Lines And Allied Works For Raksha Vihar Area Under Gei R And D Kanpur
Tender
Indian
Uttar Pradesh
Kanpur
22-11-2025

Tender Details

Tender For Repair Maintenance Of Damaged Wornout Ci Gi Pipe Lines And Allied Works For Raksha Vihar Area Under Gei R And D Kanpur; 1 Excavation in trenches, for laying of pipe line not exceeding 1.5 mtr wide and not exceeding 1.5 meter in depth and getting out in soft/ loose soil complete all as specified and as directed. 2 Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soft/ loose soil complete all as specified and directed. 3 Removing excavated material in soft/ loose soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting pointcomplete all as specified and directed. 4 M&L for cutting of PCC/Hard standing/WBM road not exceeding 30 cm in depth not exceeding 60 cm in width for passing of GI/CI pipes all as specified and directed .Note : Making good with PCC shall be measured and paid separetely under respective item. 5 M&L for cement concrete(1:2:4) type B-0 using 12.50 mm graded granite stone aggregate for repairing to disturded surfaces complete all as directed. 6 Taking up cast iron water mains 150 mm bore (including all fittings) with spigot and socket ends and lead joints, including burning out joints and recovering lead complete all as specified and as directed. 7 All as per Item No 6.00 above but 100 mm bore. 8 All as per Item No 6.00 above but 80 mm bore. 9 M&L for cast iron pipes in replacement 150 mm bore with with spigot and socket ends centrifugally cast, class LA, ISI marked in any length laid in trenches including rubber gaskets and insulation material complete all as specified and directed. 10 All as per Item No 9.00 above but 100 mm bore. 11 All as per Item No 9.00 above but 80 mm bore. 12 M&L for replacement of cast iron special fittings such as bends (any type, radius and angle) tapers any type, (straight bend, increasing, decreasing or double socket etc) Tee pieces single branch.Y junction double branch cross (all sockets or socket and spigot) collers, caps and plugs for upto 150 mm bore in mm all as specified and directed. 13 M&L for replacement ofconnecting pieces one end flanged and other socket or spigot and bell mouth pieces one end flanged other end tapering as bell mouth for upto 150 mm bore all as specified and as directed 14 M&L for replacement of gland packing of sluice valveof suitable size 80 mm to 200 mm bore including nut ,bolt and washer complete. 15 Material & Labour to repair leakages through lead joints from existing CI pipe, fittings, tee, bends tail pieces, connecting pieces etc by using previously usedand additionalrun lead , spun yarn including caulking to make the joints water tight including excavation works as required complete all as specified and directed for the following bore pipe line :- 150 mm bore pipe 16 All as per Item No 15.00 above but 100 mm bore pipe. 17 All as per Item No 15.00 above but 80 mm bore pipe. 18 Attendingof day to day complaints of external water supply of any floor and all nature i.e. leakage in water pipe lines ,fittings /fixture , no water supply including all type of complaint noted in complaint register all complaints slips received from the complaint cell and deposit the complaint slip after reactification and obtained signature of users with necessary T & Pwith experianced trade man with GI fittings i.e. elbow, tee, reducer, union, long screw socket, nipple ,plug etccomplete all as directed . Note : The complaint shall be attended and defect shall be rectified with in 24 hrs commencing from the date and time of notifying the complaint failing which a penalty @ Rs 100 per complaint per day shall be recovered from BIll. 19 Taking up/ down of following bores of steel tubing and connections from excavated trenches and building up to tripple storey with due care from site complete all as specified and directed :- 15 mm nominal bore 20 All as per Item No 19.00 above but 20 mm nominal bore. 21 All as per Item No 19.00 above but 25 mm nominal bore. 22 All as per Item No 19.00 above but 40 mm nominal bore. 23 All as per Item No 19.00 above but 50 mm nominal bore. 24 Supply & Fixing for replacement of following bore of GI tube medium grade/ ISI marked complete with all fittings (such as bends, elow, tees, connectors, caps, plugs, unions etc) including cutting, screwing as required and fixed to wall or roof or laid in plinth protection floor including fixing wall hooks,cutting through wall, floors etc and making good the disturbed surface with cement mrtar 1:3 after fixing the tubes complete all as specified and directed :- 15 mm nominal bore 25 All as per Item No 24.00 above but 20 mm nominal bore. 26 Supply & Fixing for replacement of following bore of GI tube medium grade/ ISI marked complete with all fittings (such as bends, elow, tees, connectors, caps, plugs, unions etc) including cutting, screwing as required laid in trenchescomplete all as specified and directed :- 25 mm nominal bore 27 All as per Item No 26.00 above but 40 mm nominal bore. 28 All as per Item No 26.00 above but 50 mm nominal bore. 29 Re-fixingold steel tubingand connection in new or oldposition in trenches/wall/ ceiling/ floors etc with using all new fittings complete including making good the disturbed portion as per existing pattern (PCC, road, path etc) as directed of sizes:- 15mm bore. 30 All as per item No 29.00 but size 20mm bore. 31 All as per item No 29.00 but size 25mm bore. 32 All as per item No 29.00 but size 40mm bore. 33 All as per item No 29.00 but size 50mm bore. 34 Supply and replacement of Bib tap 15 mm size ISI markedstandard of PTMT any colour high pressure screwed for iron pipes and fixed. 35 Material and Labour for brick masonry valve pit chamber of size 1200mm x 1200mm x 1200 mm (internal) complete with PCC (1:3:6) type C-2 for foundation, brick work in Cement Mortar (1:6), 15 mm thick plastering in Cement Mortar (1:4) (internally) including 6.0 mm thick MS plate covering and angle iron frame of suitable size for covering plate including coping, 100 mm thick, PCC flooring in 1:2:4 type B-1 and two coats of synthetic enamel paint over a coat of red oxide primer includingpreparation of surfaces with locking arrangement complete all as specified and directed. 36 All as per item No. 35.00 above but for valve pit of size 1000mm x 1000mm x 1000 mm (internal). 37 All as per item No. 35.00 above but for valve pit of size 800mm x 800mm x 800 mm (internal). 38 Supply & Fixed in replacement Gun metal Gate valve with iron wheel head conforming to IS : 778/ 1984, Class-1, Screwed both end as per IS: 554 Parallel, ISI marked including taking out the worn out/ old GI gate valve complete all as specified and directed suitable for 50mm Dia bore 39 All as per item No 38.00but size 40 mmbore. 40 All as per item No 38.00but size 25 mmbore. 41 All as per item No 38.00but size 20 mmbore. 42 All as per item No 38.00but size 15 mmbore. 43 Supply & fix in replacement of cast iron non-return valve 150 mm dia ISI marked with CML Noincluding nut, bolt, washer and rubber packing complete all as specified. 44 Supply and fix in replacement/ installation and testing of cast iron sluice valve,heavy duty class-I, ISI marked, conforming to I S 14846, long body type, pressure type PN-1.6,flanged ends and drilled having brass steel spindle with iron head wheel at the top complete with and including nuts, bolts, washer, rubber gasket and jointing complete all as specified and directed of following sizes:- 80mm bore 45 All as per item No 44.00but size 100mm bore. 46 All as per item No 44.00but size 150mm bore. 47 All as per item No 44.00but size 200mm bore. 48 Supply, installation, testing & Commissioning LT panel board of suitable shapeand size as approved by GE for 3 phase, 4 wire, 415 Volts, AC, 50 Hz supply, Outdoor cubical type, dust and vermin proof, pedestal mounting type suitable for Outdoor applications having suitable shape/ size canopy on top, made out of 3.15 mm thick CRCA steel sheet with using 40mm x 40mm x 5mm angle iron frame and supports,CPRI approved, duly finished with powder coated using two coats of synthetic enamel paint of approved colour over a coat of red oxide primer all over steel surfaces complete with separate Compartment of suitable shape and size with shutter and locking arrangement for each switchgear and including PCC work for fixing panel legsand bus bar of aluminium conductor suitable shape and sizeof busbar350 amps rating including fixing cables with the panelusing new lugs and glands of suitable size, separate cable alley for outgoing cables includingfollowing switchgear & controls :-- (i) Incoming :-(a) MCCB, 200 Amps, 4 pole, 415 Volts, AC supply,having breaking capacity Icu 35 KA, with adjustable load setting-01 Nos (b) Ammeter three phase, digital electronic type, size of 96 mm X 96mm, rating of 0 – 450 Amps,and in built selector switchand 3 current transformer of suitable ratio and capacity -1 Nos.(c) Indicating lamps LED typefor three phases- Qty 1 set of 3 Nos (RYB) (d)Voltmeter, three phase, (0-500V) range digital electronic type with in built selector switch - 1 nos(ii) Outgoing :- (a) MCCB,125 Amps, 4 pole, 415 Volts, AC supply,having breaking capacity Icu 25 KA - 1 Nos. (b) MCCB 63 Amps, 4 pole, 415 Volts, AC supply,having breaking capacity Icu 25 KA - 1 Nos(c) Spare compartment - 1 nos 49 M&L for earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground and earth pit not less than 2.25 mtr deep below ground leveland top edge of the plate not less than 1.5 Mtr deep below ground level surrrounded with adequate qty of char coal dus tmixed with salt to a packed thickness not less than 15 Cm on all sides of earth plate including excavation, earth work returning filling in ,removal, connectedto GI strip 25x4 mm as earthing lead withnut bolts etc and connected to earthing test pointincluding GI pipe watering light grade with CI funnel and wire mesh and PCC 1:2:4 type B-1 as in pit chamber and RCC pit cover 50 mm thick precast RCC 1:2:4 type B-1 duly re-enforced with MS bar 6mm dia @ 150mm C/C both way with 10 mm dia lifting handles, all as described in electric plate No. 3 of SSR part-I complete all as specified and directed.

Key Value

Document Fees
INR 500 /-
Tender Value
INR 13 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail