Repair/Replacement of street lights poles automatic switches connection cables & periodical service repair/ maintenance of DG Sets automatic/ Control panels, alternator, earthing and connected works at electric installations at Baisakhi Grn under GE 859 EWS.; 1 Dismantling and taking up or down old unservieable LT UG Cable of any size complete all as specified and directed. 2 Supply and Laying and connecting with appropriate lugs in replacement XLPE LT cable PVC insulated,heavy duty electric cableswith Aluminum conductors,1100 volts grade of size 10 Sqmm 2 core, laid in trenches/on pole/in pipe /on wall ,using suitable clamps for fixing of cable complete all as specified and directed of following cross-sectional area :- 3 Excavation in trenches, n exc 1.5m wide and m exc 1.5m in depth, for foundation, etc or for shafts, wells, cess-pits, menholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5m in depth and getting out for soft & loose soil. 4 Returning, filling in, including spreading, levelling, waterring and wall ramming in layers not exc 25 cm. for hard/dense soil. 5 Removing excavated material n exc. 50 m and depositing where directed at a layers not exc 25 cm. for hard/dense soil. 6 S&F High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches of size 40 mm 7 M&L for earthing complete with galvanised steel earth plate electrode 60cmX60cmX6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal groundlevel, connected to galvanised earth lead strip 32x6mm by means of volts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-5 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15 mm bore GI medium grade earth lead protection pipe, 50 mm thick RCC 1:2:4 type B-1 cover slab of earth pit reinforced with 8 mm dia TMT bars @ 10 cm C/C both ways and with handle made out of 10 mm dia bars, funnel, strainer,charcoal and testing on completion all as specified and directed.. 8 M&L in replacement GI pipe light grade with all fittings complete grouted in ground all as specified for the 40 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable complete all as specified. 9 M&L in replacement GI pipe light grade with all fittings complete grouted in ground all as specified for the 50 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable complete all as specified. 10 Supply and fix in repair weather proof PVC junction box approved by CPRI street light control box made out of not less than 2mm thick of size 200mm x 140 mm x 95mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No panel mounted connector 4 pole MCB 6A10KA 01No, including connecting up with the electrical connections and fixing and clamping complete and all as directed 11 Taking down unserviceable street light LED fitting/Flood light of any wattage and type from the pole/building of any height including disconnecting the cable connectionsfor repairing of light fittings and refixing in same position all as specified anddirected.Note : 1. Spares shall be measured and paid seperatly under relevent items.2.The cost of replacing of internal connections, screws bolts etc shall deemed to be included in the repair cost. 12 Supply only Electronic Driver for street light/Flood light fitting 25 to 50 Watts 13 Supply and fix Electronic Driver for street light fitting/Flood light fitting60 to 100 watts 14 Supply only LED platefor street light/Flood light fitting 25 to 50 Watts 15 Supply and fix LED plate for street light fitting/Flood light fitting60 to 100 watts 16 Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete. 17 Supply and fixing LED Solar street light fitting 20 Watt including galvanized steel pole of 6M height 50mm dia, in built, lithium ion battery, solar panel, charge controller all-in-one with dusk down sensor complete including taking down old unserviceable Solar street light fittings complete. 18 Supply and fixing in repair LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. 19 Supply and fixing in repair LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. 20 Supply and fixing in repair LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. 21 M<ri glow rope light 18 mtr length, Indian Triclour strip Light in single strip including taking out old unserviceable strip light all as specified and directed.Make : Havells/CG/Bajaj/Phillips 22 M&L for Wiring for circuit/submain wiring 2 x 1.5 sq mm alongwith earth wire 1.5 sqmm with the of FRLS is PVC insulated copper conductor, single core cable in from junction box to street/flood light fitting on pole of any height as required all as specified and directed by engr in charge.Note:-Two run of cable copper conductor and non metallic PVCRigid/ flexiable conduit(20mm dia) shall be measured as one unit length. 23 Material and Labour formaintinance/ Servicing, repair of Diesel Gen Set of capacity 125KVA 1500 RPM at 0.8 pf, 3 phase, 415 Volts, 50 Hz, coupled with water cooled engineincluding dismantling and opening of unserviceable spare partsof the DG set engine and cleaning with replacement of Fuel Filter, By pass filter, lube oil Filter, Air filter and fan belt (Make of these items- Ashok Layland/Crompton Greaves/Kirloskar/Mahindra. Also checking of its all parts for serviceability and replacement of defective parts(Labour cost included) and minor spares required for functioning of DG set and re-assembling complete parts,engine testing on load to the entire satisfaction of Engr-in-Charge. MAKE: Kirloskar /Mahindra/TATA Note :- 1. Servicing of DG Set to be carried out by mechanic of authorised service centre. 2. All major defective/unserviceable spare parts/items reqd for replacementshall be measured and paid separetely under appropriate items as mentioned in following here-in-after. 3. Contractor should provide technical inspection of each DG Set by an engineer of corresponding makeinstalled at site before supplying of material and incorporate the same at the site. 24 All as per item No. 1 but for 30KVA DG set. 25 S & Fand replacement of Airfilter of DG set capacity 125KVA 26 S & Fand replacement of Airfilter of DG set capacity of 30 KVA 27 S & Fand replacement of Fuel Filter of DG set capacity125KVA 28 S & Fand replacement of Fuel Filterof DG set capacity of 30 KVA 29 S & Fand replacement of Engine oil filter of DG set capacity 125KVA 30 S & Fand replacement of Engine oil filter of DG set capacity of 30 KVA 31 S&F Radiator hose pipe set with clamp complete for 30 to 125 KVA DG Set Make:Ashok Layland/Crompton Greaves/Kirloskar/Mahindra/TATA 32 Labour only for attending the complaints of DG set with controlPanel carried out by manufactures authorised mechanic from the servicing centre without any delay for rectifying the defects by carefully opening and check the DG set parts to find out defects if any at site and replace the defected parts from the DG Setfor smooth functioning as directed and specified by the Engr in charge at site (Replacement of parts shall be measured and paid seperately under relevant schedule). 33 Fuel flexible pipe, 1, 1/4 to 3/8 PVC best quality. 34 Indicating Lamp 35 Battery terminal heavy duty of brass. 36 M&L for servicing, cleaning and descaling of radiator assembly by using suitable chemical (MAC solution) and by blower fan and by injecting water in high pressure in water tubings so as to remove all dirts etc in the fins and soldering of puncture tubes to stop leakage and testing of DG Set of 5 to 125 kVA capacity mentioned below here in after as required at site and directed by Engr-in-Charge. 37 M& L for servicing, repair, calibration and testing of fuel injector assembly incl replacement of barrelsplungers cups injector and commissioning the same as required at site of DG Set of following capacity mentioned below here in after complete all as specified and directed by Engr-in-Chargeof 75 to 125 KVA . 38 All as per item ser No 37.00 but of 30 KVA 39 M&L for servicing ,repair and overhauling of self starter 12/24 V DC complete replacement of worn out fields , armature, solenoid and bendex pinion along with carbon brushes etc of DG Set of following capacity mentioned below here in after complete in all respect all as directed.of 75 to 125 KVA 40 All as per item No 39.00 but of 30 KVA 41 M&L for draining out old engine oil from DG Sets and supply and refilling/topup 15W 30/ 5W 15 new engine oil to DG Setscomplete all as specified and directed by engineer in charge( Note The Engine oil shall be supplied by the contractorto be suitable for Baisakhi Climate condition) 42 M&L for draining out old coolant from DG Sets and supply and refilling/topup DAFC 30% new coolant to DG Sets complete all as specified and directed by engineer in charge 43 Supply and filling distriled water for Battery of DG sets complete all as specified and directed by Engr-in-charge.