Tender For Provision Of Parking Shed For Cft At Airforce Station Arjan Singh Under Ge (Af) Panagarh; 1 Excavation in trenches, n.exc 1.5m wide and n.exc 1.5m depth for foundation etc. or for shafts, wells, cesspits, manholes, pier hols etc. n. exc 10sqm on plan and getting out in any type of soil complete all as specified and as directed 2 Returning, filling in trenches of any type of soil including spreading, leveling watering and well ramming in layers not exceeding 25 cm thick complete all as specified and as directed 3 Removing of excavated soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and directed. 4 M&L for PCC (1:3:6), type C-2 (using 40mm graded stone aggregates) as in foundation, filling and mass concretecomplete all as specified and directed. 5 M&L for 150mm thick PCC 1:2:4 (nominal mix) type B-1 (using 20mm graded crushed stone aggregates) laid in panels and forming construction joints as in hard standing and parking shed etc. finished even and smooth without using extra cement including filling joints with bitumen and sand mix complete all as specified and directed. 6 M&L for formwork for rough finished concrete surfacesto sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter complete all as specified and directed. 7 M&L for reinforced cement concrete (1:1.5:3) (nominal mix) type B1 (using 20 mm crushed stone aggregates) as infoundationsincluding rafts, footings, foundation beams, plinth beams,bases for asement slabs,under-reamed piles and mass concrete complete all as specified and directed.(Note:-Reinforcement and form work shall be measured and paid on separate item.) 8 M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 9 MM&L for mild steel TMT bars 5mm to 10mm diacut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends as in stirrups, spacers and binders including binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. 10 S &F for structural steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and directed. 11 M&L for Fe-410-W(Gde-E-250) quality - B, rolled mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with bolts embedded in reinforcement ofcomplete all as specified and as directed. 12 S&F for pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mmthick of approved colour having tensile strength 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed. 13 S&F for pre-painted galvalume aluminium zinc coated GI based plain steel sheet 0.50mmthick of approved colour having tensile strength 550 Mpa as in roof covering, eaves board ,ridge, hips, valley gutters, drip and straight flashing cladding ti wall etc.l fixed with self tapping screws including side and end lap as per manufacturer’s instructions complete all as specified and directed. 14 M&L for steel works as in Joist (ISMB), channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) complete all as specified and directed. 15 M&L for preparation of new or previously untreated steel or iron surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of Synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. 16 M&L for point wiring for one light point controlled by one-one way 5/6 amp switchwith 1.5 Sqmm. (nominal area) single core FRLSH,PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor unsheathed in and including non metalic rigid PVCconduit of 20mm dia (Medium grade)complete with all acessories including PVC sunk box ISI marked for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, and 1.5 Sqmm. (nominal area) single core FRLSH, PVC insulated 1100 Volts, grade multi stranded unsheathed copper conductor cable as earth wire upto common earth and connected to earth dolly including making goodthe diturbed surfaces compete all as specified and directed.(Note:-(a) Three run of copper conductor of required size and one run of PVC conduit and accessories measured as one unit and also colour coding of wiring to be followed as red/yellow/blue for phase, black for neutral and green for earth.(b) Quoted rates shall be deemed for conduit & accessories, cover plate and sunken box of suitable size, cutting chases of wall etc. and making good disturbed wall). 17 Description all as per srl item No. 16 above but for one 5 pin, socket outlet, 6 Amps on independent board but not below the switch board of light points in the same verticle plane complete all as specified and directed. 18 S&F for switch modular typeone way 6 Amps 230 volts, with one module, complete all as specified and directed. 19 S&F for socket shuttered modular type6 Amps , 2/3 pin combined, 230 volts, with two module, complete all as specified and directed. 20 S&F for ceiling rose 3 phase, PVC/polycarbonate isolated body surface bakelite2 to 3 terminals fixed to wall/ceiling complete all as specified and directed. 21 M&L for LED Tube light fitting, complete with 1x 20 watts, 220V, AC decorative box type with driver, holder in andincluding LED tube light connection complete prewiredand connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm 3 core and connector block etc and necessary fixing arrangement at any height completeall as specified and directed. (Make :- Havells cat No LHEXACP7IN1W020 or equivalent in Crompton/Philips) 22 M&L for sheet metal enclosure MCB distribution board, Single door (metal) single pole and neutral with IP-43 and IK 09 protection single phase 240 volts 4 way, including suitable size copper bus bar of 200 amp and neutral link fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification completeall as specified and directed. (Note:-MCBs will be measured separately.) 23 M&L for MCB, SPN, 240 volts, 10-40m amps with rupturing capacity 10 KA, C curve, including providing thimble for out going cables complete all as specified and directed. 24 M&L for MCB, SP, 240 volts, 6-32 amps with rupturing capacity 10 KA, C curve, including providing thimble for out going cables complete all as specified and directed. 25 S & F for modular white cover plate with frame, 3 module complete all as specified. 26 M&L for dry sand cushioning to underground cable, provided with a layer 8 cm thick before and 15 cm deep after laying and stretching jointing and testing the cable complete all as specified and as directed.(Note: Punned thickness of sand shall be measured and paid). 27 M&L for brick covering with width equal to length of brick as mechanical protection to cable using sub class ‘B’ bricks laid flat,size 230mm x 115mmx 75mm, complete all as specified and as directed. 28 M&L for 32mm dia galvanized steel tubing (light grade) with complete all fittings such as elbow, unions, nipples, tees, bends, short pieces, connections, check-nuts, caps, plugs, diminishing pieces and flanges etc as in pole, crossing of roads, laid in trenches, fixed on walls for cable protection completeall as specified and directed. 29 Supply,laying, jointing and testing,XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, armoured heavy duty electric cable with aluminium conductor 1100 volts grade of size 10 sqmm 2 core laid in trenches/ on wall, ducts, pipes, on poles and connection with necessary cables lugs, glands, suitable for mild steel saddle clips (were cable laid in ceilings/wall without cable duct) nut bolts complete all as specified and directed.(Note :- Excavation of earth work, removing, returning filling in, sand cushioning, concrete cable cover and protection GI pipe shall be measured and paid separately and length of cable shall be one length unless otherwise as directed by GE).