Tender For External Electrification Work At Sector-8 Avadh Vihar Yojna Lucknow - H.T. Work 2 S/Erection of 11 KV section Double pole structure (Riser) made of following types of supports duly grouted in 1:4:8 cement concrete (1 cement, 4 coarse sand and 8 grit of 20mm nominal size) Plinthed, Plastered and painted in the same manner as already specified for respective supports with one nos. channels of size 100x50mm and 75x40mm M.S. channel and 2 Nos. bracing of angle iron size 65x65x6mm 3M length fixed with packing piece and bolt and nuts as required including cost of material, labour and T & P required for proper completion of work as per direction of E/I. 3 11 Mts. long410 SP-55 4 Supply of following size 3 Core 11 KVH.T. cable standered compacted circular Al. conductor screen with Extruded Semi conducting compound, XLPE insulated in copper Tape, cores laid up to innersheath of PVC, Galvanised Steel Strip Armoured & overall sheathed cable confirming to IS 7098 (Part-2) 2011 with upto date Ammendmentscomplete in all respect as per Direction of E/I.Make (Polycab/ Gloster/KEI/Finolex /Universal/ Havells) 5 120 Sqmm 3 Core 6 300 Sqmm 3 Core 7 Supply and jointing of 11 KV jointing kit (Heat Sink) per XLPE cable including cost of all material Labour and T & P as per proper completion of work as per direction of E/I. Make (Raychem/3M /Densons) as per DSR 2022 S.No. 10.5.4 8 120 Sqmm 3core Outdoor 9 300 Sqmm 3core Outdoor 10 Supply of HDPE pipe upto PN-6 working pressure Rating material Grade PE-80 Nominal dia (OD) 110 mm 6.50 mm thicknesscomplete in all respect as per relevants I.S. Technicals specification. 11 Supply of HDPE pipe upto PN-6 working pressure Rating material Grade PE-80 Nominal dia (OD) 160 mm 9.50 mm thicknesscomplete in all respect as per relevants I.S. Technicals specification. 12 Drilling of Road Parallely & Road Crossing at a depth of 2 to 3 Mtr. as required & laying charges of cable & 160mm Dia HDPE Pipe complete with all material, labour, Drilling machine & required T&P etc. required for proper completion of work as per Direction of E/I. 13 S/F of following type of G.I. pipe B class for cable clamped with supports by 3 Nos. clamps made of 20x3mm M.S. flat and suitable size of nut bolt and washer required for proper completion of work as per direction of E/I. Make(TATA/SAIL/JINDAL) 14 80 mm dia 15 100 mm dia 16 Making suitable earthing of ST poles with 2.5Mts. long 20mm dia M.S. rod with 7/16 SWGG.S. wire in 15mm dia 2Mtr. long G.I. pipe duly clamped with 3 nos clampes and binding on poles including cost of labour & T & P etc. required for proper completion of work. 17 S/F of danger board (H.T.) size 200x250 mm at suitable height of pole as per direction of E/I 18 S/F of barbed wire (1.5kg) duly clamped with 20x3mm M.S. flats at both ends on steel poles at suitable height as per direction of E/I. 19 S/F of cable route marker made of 1:2:4 R.C.C. Block size 1000x400x10 mm grouted with 1:3:6 cement stone grit coarse sand 30cm below G.L. with painting numbering & marking etc. complete with all required material T&P etc. complete in all respects as per direction of E/I. 20 Supply, Installation, Testing and Commissioning of 11KV, 800Amp,18.4 KA/3 Sec , Floor rolling type, Horizontal Isolation & Horizontal Draw-out type as per IS 13118, IEC 62271-200. Vacuum Circuit Breaker should have 3 Nos. fully encapsulated Vacuum Bottels of Same manufacturer as a Circuit breaker, continuous rated Copperbusbars and droppers, Motorized spring charging mechanism (230V AC) with integral spring charging handle for manual spring charging associated Shunt Type Trip & Close Coils (24V DC). 21 11KV OUTGOING VCB PANEL : 22 Current Transformers :1 set of 3 Nos. Single Phase, 11KV, 200/100/5+5 Core 1 : Class 5P10, 5VA, Core 2 : Class 0.5, 5VA 23 Accessories : TNC Switch, Panel Space Heater, Push Button Trip Circuit Healthy Check, Panel illumination lamp with switch, 3 Pin Plug with Socket of 15Amp., Local & Remote Switch, Emergency Trip Button, AC & DC control circuit through MCB, Auxiliary Contacts (6 NO + 6 NC), Anti Pumping Device. 24 Indications : LED Type Indications for R - Y - B Phase, Breaker On/OFF, Spring Charged, Trip Circuit Healthy, Breaker Trip, Breaker Test / Service Position, AC & DC Healthy 25 Metering Instruments : 1 No. Tri-vector Meter (Acc. Cl. 0.5) of L&T/Secure make , 1 No. Digital Voltmeter (Acc. Cl. 0.5) of Rishabh, AE & Elmeasure make, 1 No. Digital Ammeter (Acc. Cl. 0.5) of Rishabh, AE & Elmeasure make 26 Protection & Auxiliary Relays : 27 1 No. Numerical 3 Over Current +1 Earth Fault (50/51/50N/51N) Relay providing Over Current ( Low Set : 5%-200%/ High Set: 50% -1600% in steps of 1%), Earth Fault (Low Set: 5%-200% / High Set: 50%-1600% in Steps of 1%) 28 1 No. Trip Circuit Supervision Relay 29 1 No. High Speed Master Trip Relay. 30 Standard features should include provision for connecting atleast one run of outgoing cables, Test Terminal Block for protection circuit. Panel fabrication shall preferably be made from structure made from AluZinc/GI sheets to prevent corrosion and rusting., safety shutters, continuous rated Close & Trip coils.VI, VCB & Panel should be of same make. Control circuit shall operate on 24V DC except Spring Charging Motor & Space Heater which shall operate on 230V AC. 31 Fabrication of adaptor panel incl. alteration/couple and matching bus bar required at site with existing panel is deemed to be included in quoted rate. Make:- ABB/Schneider/Siemens/as per direction of E/I. 32 Supply and Burring of Safe Earthing Electrode T-39 (Hot Dip Galvainised)Length up to 3000 mm, outer pipe 76 mminner dia 38mmterminal Dia 12 mm, outer GI Pipe of SWG and inner GI Pipe of 12 SWG with Hot Dip Galvanisation up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square CI frame with hinged cover & masonary housing ( from electrode terminal to switch board, cost of 25x3 G.I. Strip will be extra) UPPWD SOR-2018 item no. 725 (D) 33 Supply & Laying of 25mm x 3mm G.I. Strip from Earth Electrode directly in the ground as required complete in all respect as per PWD SOR 2018 S.No. 716 34 LT & Transformation 35 Supply and Erection of Double Pole Structure made of following types of support duly grouted in 1:4:8 cement concrete (1 cement, 4 coarse sand and 8 grit of 20mm nominal size) plinthed, plastered & painted in the same manner as already specified for respective supports sutable for plinth mounted type substation with different types of M.S. Channel and angle iron duly fabricated for disc fittings D.O. fuse set, TPMO ladder stand projecting outside dropper and bracings , including cost of all material, labour and T & P required for proper completion of work as per drawing and direction of E/I. 36 With 11 Mts. long 410 SP 55 S.T. Pole 37 Supply and Erection of 11 KV TPMO set complete in all respects ( as per Specification No. 21) 38 Supply and Erection of 11 KVD.O. fuse set complete in all respects. ( as per Specification No. 22) 39 Supply and fixing of H.T./L.T. jumpering and connections on double pole/four pole, lightning arrestor and transformer. The rates include the cost of all materials, labour and T & P etc. required for proper completion work. 40 Supply Installation, Testing and commissioning of 11 /0.433 KV Transformer of following capacity as per BIS 1180-2014 Standard. The rates also including loading unloading local carriage and T & P charges etc. 41 250 KVA, 11/0.433KV (Level-1) 42 400 KVA, 11/0.433KV (Level-1) 43 Supply, installation, testing and commissioning of Outdoor Type,dust and vermin proof weather proof with rain canopy on four sideswith locking arrangement, 800A/630A ACB L.T Panel Fabricated out of 2.0mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer in charge after proper sheet treatment process of sheet steel. All indicating lights shall be LED type and all wiring shall be done from PVC Insulated copper flexible wire. The panel shall be completed in all respect and shall consist of following material.Incomer: 630AF.P Manual Fixed type A.C.B with Metering (ie Ameter with ASS, Voltmeter with VSS) along with, Phase Indicating Lights, CT,Control MCB etc. -1 Set Panel will have suitable rating (1Amp/Sqmm) of Aluminium Bas bar for Proper Temination of Cables. ( minimum 400 sqmm6 nos )All bus bars shall be insulated with coloured heat shrinkable PVC sleeved. All bus bar supports shall be non hygroscopic DMC/SMC supports. 44 800/630 A 45 S/F of lightening arrestor set (3 Nos.) suitable for mounting on steel supports complete with all materials, labour and T & P required of proper completion of work as per direction of E/I. 46 Supply & Erection of TPN Distribution Pillar Fabricated with Wire Clad Dust and Vermin Proof as per Drawing consisting suitable size of Copper Bus Bar 60 x10mm or Equivalent sectional area consisting Henleys Pattern fuse unit set complete as follows, Metallic Pillar shall be made of 14 SWG MS Sheet on frame of angle Iron size 35x35x5mm Duly painted with 2 Coat of approved paint over rust resisting primer both side locking arrangement and handle & Danger Board complete with suitable masonary plate-form for mounting the pillar. The Pillar shall have earthing terminals as per Direction of E/I. 47 Incoming : Two (2) Nos. 300 Amp.Fuse unit 48 Outgoing : Four (4) Nos. 300 Amp.Fuse unit 49 Supply & Erection of TPN Distribution Pillar Fabricated with Wire Clad Dust and Vermin Proof as per Drawing consisting suitable size of Copper Bus Bar 60 x10mm or Equivalent sectional area consisting Henleys Pattern fuse unit set complete as follows, Metallic Pillar shall be made of 14 SWG MS Sheet on frame of angle Iron size 35x35x5mm Duly painted with 2 Coat of approved paint over rust resisting primer both side locking arrangement and handle & Danger Board complete with suitable masonary plate-form for mounting the pillar. The Pillar shall have earthing terminals as per Direction of E/I. 50 Incoming : Two (2) Nos. 500 Amp.Fuse unit 51 Outgoing : Six (6) Nos. 300 Amp.Fuse unit 52 Supply Intallation testing and commissioning of 300Asub Feeder Pillar. The Feeder Pillar shall be fabricated outof 2.0mm thick CRCA sheet steel, painted with Powder coated paint of shade as per the direction of EngineerIn‐Charge after proper sheet treatment process of sheet steel. The Busbar of Panel shall be of High gradeElectrical grade High Conductive Aluminum alloy of appropriate cross section as per rating. The calculation ofcontinuous rating of Bus Bar shall be submitted. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted on proper interval to ensure bear the jerks of shortCircuit as fault level require. The Fault level of Panel shall be 50kA for 1sec. The Feeder Pillar shall be dust & Vermin Proof ,weather proof, rain canopy all four sides ,locking arrangements with Degree pf Protection IP : 55.The Feeder Pillar shall be completed in all respect and shall consist of following material.Incomer : 300A Kit Kat type Fuse Unit – 3 Set with Neutral Bus BarOutgoing: Suitable Bus Bar only with Provision to connect atleast 30 Nos. Outgoing Cables . up to3.5 core 35sqmm size 53 Construction of fencing plinth of following sizes in Ist class brick work including plaster and providing flat bricks soling and pointing the same with 1:2 cement and fine sand mortar over 75mm thick cement concreting in the ratio 1:6:12 in open space of the cage as per direction of E/I and drawing. 54 6x4x0.23m for Substation 55 2x3x0.23m for Subfeeder Pillar 56 Supply of fixing of 2.45M. High cage fabricated with 3.0mm thick expanded metal/wire mesh of equivalent weight fixed on 50x50x6mm angle iron frame having vertical members spaced at 1.0M to 1.25M. and horizontal members spaced at 1.20M the vetical members shall be grouted in ground and horizontal members in the wall to a depth of 300mm with ends folded. The cage shall have 1000x2000mm size single leaf door with locking arrangement having door frame fabricated with 35x35x5mm angle iron and 3mm expanded metal wire mesh of equivalent weight duly fixed with the cage member. The cage shall have nut bolt arrangement for opening the sides by providing tees 45x20cm of angle iron size 50x50x6mm as per direction of E/I. It shall be painted with red oxide primer and synthetic enamelled paint as per direction of E/I. including all materials, labour and T & P for proper completion of work.PWD SOR 2018 SI No. 1142 57 Supply and burring of Safe Earthing Electrode T-39 ( Hot Dip Galvanized) Length up to 3000mm, outer Dia 76 mm inner 38 mm, terminal Dia 12mm, outer G.I. Pipe of 16 SWG & Inner G.I. Pipe 12 SWG with Hot Dip Galvanization upto 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm Square C.I. Frame with hinged cover & masonry housing.( from ElectrodeTerminal to switch board, cost of 25 x 3 G.I. Strip will be extra)As per PWD SOR-2018 S.I. No.-725 (D)Make: As approved in U.P. P.W.D., & C.P.R.I. Certified 58 Supply & Laying of 25mm x 3mm G.I. Strip from Earth Electrode directly in the ground as required complete in all respect as per PWD SOR 2018 S.No. 716 59 Construction of plinth for Transformer size 2.0x1.25x1.0 Complete With all materials, labour and T & P required for proper completion of work as per specification drawing and direction of E/I. 60 Supply of following size of Al. conductor XLPE Insulated, Cores Laid up, PVC Innersheathed, Armouredwith Galvanised Al. Strip Extruded PVC Type ST2 Outer Sheathed, 650V/1100 Volt Grade as per IS 7098 (Part I) 1988 With up to date Ammendments Make Polycab/Gloster /Finolex /Universal /KEI /Havells 61 120 Sqmm 3½ core 62 Supply and Laying of following Size of Aluminium Conductor PVC Insulated armoured served sheathed cable 1100 Volt grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top as directed by Engieer in Charge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth conductor by clamps etc as per PWD SOR 2024 S.No. 20a.1.18 & 20a.1.20 (Without GST Rate 2324.00x0.8475=1970.00 and 3376.00x0.8475=2861.00) 63 240 Sqmm 3½ core 64 400 Sqmm 3½ core 65 Supply and fixing of palm or pin copper tin plated cable socket (lugs) to the cable leads insulating with tape and making connections etc. complete in all respects as per PWD SOR 2018 SI No. 504 (h), (j), (m) & ( o) 66 70 Sqmm 67 120 Sqmm 68 240 Sqmm 69 400 Sqmm 70 Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouribg of the cable shall be properly connected with the earth as per direction of Engineer-Incharge. as per PWD SOR 2018 S.No. 503 (o)(r) & (t) 71 120 Sqmm 3½ core 72 240 Sqmm 3½ core 73 400 Sqmm 3½ core 74 Supply of HDPE pipe upto PN-6 working pressure Rating material Grade PE-80 Nominal dia (OD) 110 mm 6.50 mm thicknesscomplete in all respect as per relevants I.S. Technicals specification. 75 Digging & Refilling of Same Trench Parallel to Road at a depth of 1.5 Mtr. as required & laying charges of cable & different size HDPE Pipe (PN-6 PE 80 Grade) complete with all material, labour and T&P etc. required for proper completion of work as per Direction of E/I. 76 S/F of danger board (H.T.) size 200x250 mm at suitable height of pole as per direction of E/I 77 Construction of brick masonary service connection chamber of 0.45x0.45x0.60m high of 23 cm thick wallwith coverin cement mortar (1 cement: 4 coarse sand) R.C.C top slamb with 1:2:4 mix(1 cement:2 coarse sand: 4 graded stone aggregate 20mm, nominal size) foundation concrete in 1:6:12 (1 cement:6 coarse sand and 12 graded stone aggregate 40 mm nominal size) inside blastering 12mm thick with 1:4 cement & Coarse sand) finished with floating coat of neat cement complete inside size 0.45x0.45x0.60m with class 150 Brick. 78 Street Light 79 Supply & fixing of 9 mtr. GI Octagonal Pole of approved make (top dia 70 mm, Bottom dia 155 mm and base plate 16 mm thick) having 3 mm thickness with single arm bracket length of 1 mtr length in 1:2:4 RCC Foundation bolt including the cost of foundation, excavation & back filling and Required T&P complete in all respect. UP PWD SOR 2024 SI No-21.2.4 Make Bajaj/Vallmont/RRISPAT CONSOUL (Without GST Rate 30046.00x0.8475=25464.00) 80 Supply & fixing of 7 mtr. GI Octagonal Pole of approved make (top dia 70 mm, Bottom dia 130 mm and base plate 12 mm thick) having 3 mm thickness with single arm bracket length of 1 mtr length in 1:2:4 RCC Foundation bolt including the cost of foundation, excavation & back filling and Required T&P complete in all respect. UP PWD SOR 2024 SI No-21.2 Make Bajaj/Vallmont/RRISPAT CONSOUL (Without GST Rate 21657.00x0.8475=18354.00) 81 Supply and fixing of LED Street Light Fitting with mandatory driver set having die cast aluminium body with toughend glass/UV stabilized PC Cover and lenses suitable for 75 Watt to 90 Watt and Confirming to IP 66, and IK07 and above protection having company LOGO Engraved complete in all respect including Labour. 9000-10800 system lumens, High Power LED with lenses, 120 Lm/W, PF>0.95, THD<10% at full load, CRI>70, Potted driver set in Metal housing (Not Circuitory) phase to phase protection at 440V & >300V auto cut and re-start feature, 4 KV internal surge protection with 5 years warrantee.CAT-AAA PWD SOR 2024 SI No-23.16 Make Havells/Polycab/Philips/Jaquar (Without GST Rate 10124.00x0.8475=8580.00) 82 Supply and fixing of LED Street Light Fitting with mandatory driver set having die cast aluminium body with toughend glass/UV stabilized PC Cover and lenses suitable for 45 Watt to 50 Watt and Confirming to IP 66, and IK07 and above protection having company LOGO Engraved complete in all respect including Labour. 5400-6000 system lumens, High Power LED with lenses, 120 Lm/W, PF>0.95, THD<10% at full load, CRI>70, Potted driver set in Metal housing (Not Circuitory) phase to phase protection at 440V & >300V over voltage auto cut and re-start feature, 4 KV internal surge protection with 5 years warrantee.CAT-AAA PWD SOR 2024 SI No-23.14 Make Havells/Polycab/Philips/Jaquar (Without GST Rate 5055.00x0.8475=4284.00) 83 S/F of following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contractors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect UPPWDSOR 2018 SI No-807 84 40 A TPN 85 Making suitable earthing of PCC/ST poles with 2.5Mts. long 20mm dia M.S. rod with 7/16 SWGG.S. wire in 15mm dia 2Mtr. long G.I. pipe duly clamped with 3 nos clampes and binding on poles including cost of labour & T & P etc. required for proper completion of work. 86 Supply and burring of Safe Earthing Electrode T-39 Zn-Zinc Coated, Length 3000mm, outer pipe 76.3mm x 3.2 inner pipe 42.4mm x 2.6mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonry housing. (From electrode terminal to switch board, cost of 25 x 3 G.I. Strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified.UPPWD SOR-2018 item no. 726 (D) 87 Supply & Laying of 25mm x 3mm G.I. Strip from Earth Electrode directly in the ground as required complete in all respect as per PWD SOR 2018 S.No. 716 88 Supply and Laying of following Size of Aluminium Conductor PVC Insulated armoured served sheathed cable 1100 Volt grade at a depth of 750mm below ground level over a cushion of 75mm thick sand all around and protected with burnt bricks on sides and on top as directed by Engieer in Charge complete in all respect including excavation and refilling and crossing the road, cable should run through 140mm dia hume pipe and in case of air like catenary it shall be hanged with the help of G.I. wire, clipped at several places as per direction of E/I for proper completion of work. The armouring of the cable shall be properly connected with the earth conductor by clamps etc as per PWD SOR 2024 S.No. 20a.1.9 & 20a.1.11 Make Polycab/Gloster/Finolex /Universal /KEI /Havells (Without GST Rate 618.00x0.8475=524.00 and 724.00x0.8475=614.00) 89 16 Sqmm 4 Core 90 35 Sqmm 3.5 Core