Creation of 63KVA Sub station along with HT/LT Network at BALSHAMA NEAR ASHWANI KUMAR HOUSE W.NO. 02UNDER SSY GRANT 2025-26 2Creation of 63KVA S/stn along with HT/LT Network at BALSHAMA NEAR VIJAY KUMAR HOUSE W.NO. 03 UNDER SSY GRANTS 2025-263. Creation of 63KVA S/stn along with HT/LT Network at BADWAIN MOH BHAKER W.NO. 06 UNDER SSY GRANTS2025-264.Creation of 63KVA S/stn along with HT/LT Network at MAJOR YRS SHARMA MOH W.NO. 06 MARCHOLA UNDER SSY GRANTS 2025-26 - 1 Creation of 63KVA S/stn along with HT/LT Network at BALSHAMA NEAR ASHWANI KUMAR HOUSE W.NO. 02UNDER SSY GRANT 2025-26 2 SITC OF HT Line 3 S.T Pole 8 mtrs long (410-SP15) 4 Galvanisied Channel cross-armincluding clamps and braces. 5 30 mm2 ACSR Weasel Conductor 6 11 kv Pin insulators with pins (10KN) 7 11 kv Disc insulators with fittings (45 KN) 8 Galvansied Nuts and Bolts of sorts 9 SITC OF SUB STATION 10 S.T Pole 8 mtrs long (410-SP15) 11 Surge Arrester Station Type9KV, 10 kA (Polymer Type) 12 11 KV Horn Gap Set, 3 Phase, 200 Amp 13 11 KV Link Set 14 Channel/Flate/Angle in shape of fabricatedX-arms, Top bracket, Angle braces, clamps etc. 15 GI Stay sets complete with 50*8mm stay clamp ,guy insulator(2 nos.),anchor plate(200*200*6mm),nut-bolts,turn -buckles(2 nos.),1.8m long,16mm diameter solid GS stay rod and 7/3.15 mm dia GI stranded wire complete. 16 PVC insulated stranded conductor FRLS type 1.1kv GradeCable 120mm sq with Thimbles 17 11 kv Pin insulators with pins (10KN) 18 11 kv Disc insulators with fittings (45 KN) 19 Nuts and Bolts of sorts 20 Earthing of Sub-station ,excavation of earth pit of dia 650mm and depth 3000mm,installation of earthing pipe of 40mm nominal bore and 4mm wall thickness and length 2.5 mtr.long as per IS 1239.GI strip for neutrl earthing of size 25 mm*3 mm for connection of transformer body ,G.O set and lightening arrestor as per IS 2629/85,GI nuts and bolts ,refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover.(Specification as per cost data) 21 Sundry Items/POL 22 SITC OF LT Line 23 S.T Pole 8 mtrs long (410-SP15) 24 30 mm2 ACSR Weasel Conductor 25 Shakle Insulator(16KN) 26 Mukky Clamps 27 Nuts and Bolts of sorts 28 Creation of 63KVA S/stn along with HT/LT Network at BALSHAMA NEAR VIJAY KUMAR HOUSE W.NO. 03 UNDER SSY GRANTS 29 SITC OF HT Line 30 S.T Pole 8 mtrs long (410-SP15) 31 Galvanisied Channel cross-armincluding clamps and braces. 32 30 mm2 ACSR Weasel Conductor 33 11 kv Pin insulators with pins (10KN) 34 11 kv Disc insulators with fittings (45 KN) 35 Galvansied Nuts and Bolts of sorts 36 SITC OF SUB STATION 37 S.T Pole 8 mtrs long (410-SP15) 38 Surge Arrester Station Type9KV, 10 kA (Polymer Type) 39 11 KV Horn Gap Set, 3 Phase, 200 Amp 40 11 KV Link Set 41 Channel/Flate/Angle in shape of fabricatedX-arms, Top bracket, Angle braces, clamps etc. 42 GI Stay sets complete with 50*8mm stay clamp ,guy insulator(2 nos.),anchor plate(200*200*6mm),nut-bolts,turn -buckles(2 nos.),1.8m long,16mm diameter solid GS stay rod and 7/3.15 mm dia GI stranded wire complete. 43 PVC insulated stranded conductor FRLS type 1.1kv GradeCable 120mm sq with Thimbles 44 11 kv Pin insulators with pins (10KN) 45 11 kv Disc insulators with fittings (45 KN) 46 Nuts and Bolts of sorts 47 Earthing of Sub-station ,excavation of earth pit of dia 650mm and depth 3000mm,installation of earthing pipe of 40mm nominal bore and 4mm wall thickness and length 2.5 mtr.long as per IS 1239.GI strip for neutrl earthing of size 25 mm*3 mm for connection of transformer body ,G.O set and lightening arrestor as per IS 2629/85,GI nuts and bolts ,refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover.(Specification as per cost data) 48 Sundry Items/POL 49 SITC OF LT Line 50 S.T Pole 8 mtrs long (410-SP15) 51 30 mm2 ACSR Weasel Conductor 52 Shakle Insulator(16KN) 53 Mukky Clamps 54 Nuts and Bolts of sorts 55 Creation of 63KVA S/stn along with HT/LT Network at BADWAIN MOH BHAKER W.NO. 06 UNDER SSY GRANTS 56 SITC OF HT Line 57 S.T Pole 8 mtrs long (410-SP15) 58 Galvanisied Channel cross-armincluding clamps and braces. 59 30 mm2 ACSR Weasel Conductor 60 11 kv Pin insulators with pins (10KN) 61 11 kv Disc insulators with fittings (45 KN) 62 Galvansied Nuts and Bolts of sorts 63 SITC OF SUB STATION 64 S.T Pole 8 mtrs long (410-SP15) 65 Surge Arrester Station Type9KV, 10 kA (Polymer Type) 66 11 KV Horn Gap Set, 3 Phase, 200 Amp 67 11 KV Link Set 68 Channel/Flate/Angle in shape of fabricatedX-arms, Top bracket, Angle braces, clamps etc. 69 GI Stay sets complete with 50*8mm stay clamp ,guy insulator(2 nos.),anchor plate(200*200*6mm),nut-bolts,turn -buckles(2 nos.),1.8m long,16mm diameter solid GS stay rod and 7/3.15 mm dia GI stranded wire complete. 70 PVC insulated stranded conductor FRLS type 1.1kv GradeCable 120mm sq with Thimbles 71 11 kv Pin insulators with pins (10KN) 72 11 kv Disc insulators with fittings (45 KN) 73 Nuts and Bolts of sorts 74 Earthing of Sub-station ,excavation of earth pit of dia 650mm and depth 3000mm,installation of earthing pipe of 40mm nominal bore and 4mm wall thickness and length 2.5 mtr.long as per IS 1239.GI strip for neutrl earthing of size 25 mm*3 mm for connection of transformer body ,G.O set and lightening arrestor as per IS 2629/85,GI nuts and bolts ,refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover.(Specification as per cost data) 75 Sundry Items/POL 76 SITC OF LT Line 77 S.T Pole 8 mtrs long (410-SP15) 78 30 mm2 ACSR Weasel Conductor 79 Shakle Insulator(16KN) 80 Mukky Clamps 81 Nuts and Bolts of sorts 82 Creation of 63KVA S/stn along with HT/LT Network at MAJOR YRS SHARMA MOH W.NO. 06 MARCHOLA UNDER SSY GRANTS 83 SITC OF HT Line 84 S.T Pole 8 mtrs long (410-SP15) 85 Galvanisied Channel cross-armincluding clamps and braces. 86 30 mm2 ACSR Weasel Conductor 87 11 kv Pin insulators with pins (10KN) 88 11 kv Disc insulators with fittings (45 KN) 89 Galvansied Nuts and Bolts of sorts 90 SITC OF SUB STATION 91 S.T Pole 8 mtrs long (410-SP15) 92 Surge Arrester Station Type9KV, 10 kA (Polymer Type) 93 11 KV Horn Gap Set, 3 Phase, 200 Amp 94 11 KV Link Set 95 Channel/Flate/Angle in shape of fabricatedX-arms, Top bracket, Angle braces, clamps etc. 96 GI Stay sets complete with 50*8mm stay clamp ,guy insulator(2 nos.),anchor plate(200*200*6mm),nut-bolts,turn -buckles(2 nos.),1.8m long,16mm diameter solid GS stay rod and 7/3.15 mm dia GI stranded wire complete. 97 PVC insulated stranded conductor FRLS type 1.1kv GradeCable 120mm sq with Thimbles 98 11 kv Pin insulators with pins (10KN) 99 11 kv Disc insulators with fittings (45 KN) 100 Nuts and Bolts of sorts 101 Earthing of Sub-station ,excavation of earth pit of dia 650mm and depth 3000mm,installation of earthing pipe of 40mm nominal bore and 4mm wall thickness and length 2.5 mtr.long as per IS 1239.GI strip for neutrl earthing of size 25 mm*3 mm for connection of transformer body ,G.O set and lightening arrestor as per IS 2629/85,GI nuts and bolts ,refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover.(Specification as per cost data) 102 Sundry Items/POL 103 SITC OF LT Line 104 S.T Pole 8 mtrs long (410-SP15) 105 30 mm2 ACSR Weasel Conductor 106 Shakle Insulator(16KN) 107 Mukky Clamps 108 Nuts and Bolts of sorts 109 MISC 110 Providing of computriised single diagram of the complete work depicting all vital items including landmark (size of sheet 24X24 inch) 111 Providing of geo tagged coloured photographs of all the vital items of the work including name plate of Transformer(size of photograph 4X6 inch)