Tender For General-Chengalai Grama Panchayat-Purchasing Installation Of Generator For Aluvachakari Gas Crematorium-Project No-S0164/26-General Electrical Work - wiring 2 OD43957/2025-2026:Supply, Loading, Conveyance, unloading, and erection of 15 KVA DG Set with Acoustic enclosure as per CPCB 4+norms and as detailed below. 1. Engine- a. Make of engine - Kirloskar, Mahindra, Ashok lyleand, Cumins b. Type of Engine - Diesel Engine. c. No of Cylinders - As per manufactures standard. d. Method of cooling - Water cooled with radiator. e. Aspiration - Naturally Aspirated. f. Design - Suitable for generating set operation. g. Output - Suitable for generating set operation. 2. Standard accessories with Diesel Engine a. Fly wheel. b. Close Coupled. c. Air cleaner. d. Radiator with fan provided with fan guard. e. Fuel Pump. f. Mechanical /Electronic governor. g. Fuel filter. h. Lubricating oil filter. i. Residential type exhaust silencer. j. Battery Charger / Generator. 3. Engine Instrument Panel with the following items. a. Starting switch with key or button and Remote control b. Lubricating oil pressure gauge. c. Water temperature gauge. d. RPM Indicator with hour meter. e. Battery charging ammeter. 4. Safety Controls for Engine a. Battery control (trip) for low lubricating oil pressure. a. Battery control (trip) for high water temperature. 5. Brush less alternator a. Make - Kirloskar/ KEL/Stamford/Crompton/Integrated electric Ltd b. Type - Self exited and self regulated c. Capacity - 15 KVA / 12 KW @ 0.8PF d. System of Voltage - 3Phase, 415V, 4 Wire system. f. Speed - 1500 rpm. g. Frequency - 50Hz. h. Insulation - Class F/H The alternator should confirm to IS 4722/IS13365. Operation and service manual shall be provided 6. Fuel Tank Suitable size fitted (built in type) inside the acoustic enclosure 7. Battery Suitable size fully charged battery with leads and terminals of appropriate AH capacity as per Manufactures required including battery charger. 8. Standard control panel a.32 A 4 Pole MCCB Set at 25 A b. 1No multi function meter suitable for display of current in 3Phases, voltage in 3 Phases, frequency, power factor, KVA, KVAh, KVAr, KVArh, KW etc. c. 1 No separate KWH meter d. Necessary measuring CTs of appropriate ratio and burden for the required meter. d. Instrument fuse/MCB - 2set f. Metallic DNB - 1No g. Solid state phase indication lamp for supply ON/OF with Fuse / MCB protection. 3 OD43975/2025-2026:Supply conveyance installation testing and commissioning 32 A, 4 pole On-Load Change Over Switches In SS Enclosure and giving connection as required 4 2.24.1:Supplying and fixing Cable End Box (Loose Wire Box) (IP 43) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required.For 4 way, Double door TPN MCBDB 5 OD43995/2025-2026:Supply and Providing LED indicators for all voltage ranges - Red, Green, Black, Yellow or Orange Colour 6 2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 7 1.17.5:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 X 1.5 Sq. mm 8 OD43956/2025-2026:Supply of High speed Speed Diesel for test run 9 14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres. 10 14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. 11 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels 12 90.12.5.40:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 10 sq mm 13 90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp 14 90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size 15 9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm) 16 90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm 17 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 18 OD43954/2025-2026:Supply and providing test joint for the earthing system using 2 x 25 x 3 mm GI strip including cutting and bending to shape, drilling necessary holes and fixed to the watering pipe etc as required 19 OD43947/2025-2026:Supply and providing earth lead from the test joint to the earth electrode using 25 x 3 mm GI strips including cutting, drilling necessary holes (in case of strip) and fixing firmly with plate test joint etc as required 20 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) 21 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) 22 90.16.3.9:Supply and clamping the following size of strips on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 X 3 mm GI flat duly painted or heavy duty GI spacer saddles spacing of clamps not exceeding 1 m, making good the damages, colour washing etc. as required ( for horizontal run)25 x 3 mm copper strip 23 OD43952/2025-2026:Supply and providing the 25 x 3mm brass bolt & nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required 24 OD43950/2025-2026:Supply and installation of ABC type fire extinguisher of 6 kg. Capacity complete with initial charges and installation brackets, with ISI mark IS:15222. 25 OD43948/2025-2026:Supply and providing 2 mm thick & 1 m wideelectrical grade chequered type insulation mat to withstand 3.3 KV dielectric strength conforming to IS 15652/06 26 90.3.17.3:Supply, conveyance and erection ofthe following sizes of B class GI pipe in single section for post top lantern of all types on concrete base (excluding charges for concrete base and excavation) and painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer etc. as required.50 mm dia GI pipe 27 OD43953/2025-2026:Supply conveyance fixing corrugated sheet for roofing and other allied works as required 28 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board 29 OD43951/2025-2026:Charges for preparation and submission of documents such as plan,scheme etc for approval of Generator installation from KSELB& KSEB (Excluding CD Charge) 30 OD43974/2025-2026:Statutory Fee and other deposit amount to KSELB & KSEB for approval from the concerned department for generator installation. (LS provision as per the receipt)