Indian Tenders

Tender Notice

TDR 49930154
Tendering Authority Municipal Corporation Aurangabad
Tender No CSMC/Dy.Eng/Building/2025/123
Tender ID 2025_AMCA_1195871_1
Tender Brief Tender For Construction And Development Of Working Women Hostel At Kanchanwadi Chhatrapati Sambhajinagar
City Aurangabad
State Maharashtra
Document Fees INR 5900 /-
EMD INR 847208.0 /-
Tender Value INR 16.94 Crore /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Construction And Development Of Working Women Hostel At Kanchanwadi Chhatrapati Sambhajinagar- 1 Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) 2 Excavation for foundation in Hard murum including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 to 3.0m.) By Mechanical Means 3 Excavation for foundation in earth, soils of all types, sand,gravel and soft murum, including removing the excavated material upto a distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5m to 3.0m) By Mechanical Means 4 Excavation for foundation in Hard-rock by blasting including trimming and leveling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the building area including dewatering and back filling with available earth/murum watering, ramming etc. complete. (Lift from 1.5m To 3.0 m) By Mechanical Means 5 Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steelcentering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 6 Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) treatment by treating the backfill in immediate contact with foundation at the rate of 5 litres of emulsion concentrate of 1.0 percent of clorophyrifos per One Square Metre of vertical surface area covering 10 years guarantee on bond paper. 7 Filling in plinth and floors with approved excavated material in 15cm. to 20cm. Layers including watering and compacting etc. complete 8 Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced Cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/- with ponding test etc complete. (excluding Cement concrete 1:3:6 base concrete) 9 Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. 10 Providing and laying Cast in situ/Ready Mix cement concrete in M15 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 11 Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite/quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 12 Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 13 Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 14 Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 15 Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) 16 Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. 17 Filling in plinth and floors with contractorsmaterial/brought from outside and approved by Engineer inchargein layers of 15 cmto 20 cm including watering and compaction etc.complete. 18 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete. 19 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints,watering and scaffolding etc. Complete 20 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 mm diameter / 2 hoop iron strips 25 mm X 1.6 mm placed at every third course, properly bent and bonded at ends scaffolding, racking out joints and watering etc. complete. 21 Providing and fixing precast R.C.C. frames of door/windows/ ventilators of c/s 125mm X 50mm with 2 bars of 8mm dia. Of steel as r/f . In half brick wall 22 Providing and fixing solid core flush door shutter in single leaf 32 mm thick decorative type of exterior grade as per detailed drawings approved face veneers 3 mm thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. 23 Providing and fixing mild steel grill work for windows, ventilators, etc. 15 Kilogram/Square Metre as per drawing including fixtures necessary welding and painting with one coat of anticorrosive paint and two coats of oil painting complete. 24 Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (Without mechanical gear) 25 Providing and fixing in position (as per 1868 / 1982) Alluminium sliding window of three tracks with rectangular pipe 95 x 38.10 x 0.90 mm at weight 0.637 Kilogram/One Running Metre. with window frame bottom track section 92 x 31.75 x 1.30 mm at weight 1.070 Kilogram/One Running Metre.. Top and side track section 92 x 31.75 x 1.30 mm at weight 0.933 Kilogram/Running metre. The shutter should be of bearing bottom 40 x 18 x 1.25 mm at weight 0.417 Kilogram/One Running Metre. Inter locking section 40 x 18 x 1.10 mm at weight 0.469 Kilogram/Running metre. and handle and top section 40 x 18 x 1.25 mm at weight 0.417 Kilogram/Running metre. As per detailed drawings and as directed by Engineerincharge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 mm thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With colour Anodising with box. 26 Providing internal cement plaster 12mm thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc 27 Providing internal cement plaster 20mm thick in Single coats in cement mortar 1:5 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc.complete 28 Providing rough cast cement plaster externally in two coats to concrete, brick or stone masonry surfaces in all positions with base coat of 12 to 15 mm thick in C.M. 1:4 and rough cast treatment 12mm thick in proportion 1:1 1/2:3 including scaffolding and fourteen days curing complete. 29 Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. 30 Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. 31 Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. 32 Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or a directed etc. complete. 33 Providing and fixing screw down for 20 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete 34 Providing and fixing 100 mm dia. chromium plated brass showers rose to 15mm dia. supply pipe including necessary bend and socket complete 35 Providing and fixing H.D.P container one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow pipe inclusive of all tanks capacity above 1000 to 20,000 litres 36 Providing and fixing European type white glazed earthenware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the outside face of wall 10 litre enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 mm dia. UPVC flush pipe with fittings and clamps ,20 mm dia.UPVC overflow pipe ,mosquito proof couplings G.I. chain and pulley,with water Jet and fitting including cutting and making good to the walls and floors testing etc. complete.(prior approval of sample and brand by Ex. Engineer is necessary before use) 37 Providing and fixing Orissa type white glazed earthenware 575 mm water closet pan including S trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etc. complete. 38 Providing and fixing C.P. wall mixer with provision for overhead shower with 115mm long bend pipe and wall flange of approved make including necessary sockets/union nut etc. complete 39 Providing and fixing white glazed earthenware Wash Hand Basin of 55cm. x 40 cm. size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connections including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. 40 Providing and fixing 10cm C.I. Nahani Trap including C.I. grating bend and piece of C.I. pipe upto the outside face of the wall complete. 41 Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete 42 Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. 43 Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete 44 Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. 45 Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. 46 Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. I. cover of 75Kilogramwith lid and frame fixed in cement concrete 47 Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (MJP-SSR- 2023-24, Bd A1/259) 48 Lift 0 to 1.5 M Cum 140.00 140.00 Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-incharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (MJP-SSR- 2023-24, Bd-A-2/259) 49 Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-incharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (MJP-SSR- 2023-24, Bd-A-4/259) 50 Providing ISI standard stoneware pipes including all taxes inspectin charges, railway freight, unloading, transoport, stacking,complete.150mm dia. SWG pipe 51 Louvering and jointing in proper grade, alignment standard stoneware pipes with cement joint 1:6 C.M. proportion including unloading, transoport, stacking, necessary excavation and jointing complete. 150mm dia. SWG pipe 52 Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete 53 Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. (SSR.Item no. 35.21) 54 Providing and applying interior wall finish luster of approved make on internal wall surface as detailed below Scrapping the surface with emery paper and wipe clean wall primer with brush with mineral turpentine with brush 8 to 10% and oil 15 to 20% with roller and allowing to dry for a period 6 to 8 hours. wall putty with appropriate proportion of water allowing to dry for period 4 to 6 hours. Scrapping with Emery paper 180 and wipe clean. Applyingwall primer with brush with mineral turpentine 8 to 10% and oil 15 to 20% with roller Scrapping Emery paper 320 and wipe clean, interior wall finish luster 1st coat with brush/rubber/spray with mineral turpentine 7 to 9% and Oil with roller 19 to 21% After 8 hours of activity Applying 2nd coat or wall finish Lustre with mineral turpentine 7 to 9 % with brush and Oil with roller 19 to 21% after allowing dry for the period of 6 to 8 hours activity. (With prior approval of S.E.) 55 Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. 56 Providing and applying two coats of exterior weather shield paint of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plaster surface, applying primer coat, scaffolding if necessary, and watering the surface for two days etc complete. 57 Transportation of surplus material from work site to any disposal place as directed by Er.incharge eith a lead of 5km including and stacking completed. 58 Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing/moulding the sharp edges wherever necessary, curing, etc. complete. 59 Providing structural steel work in hollow section of various thickness and sizes in square, rectanular and round shape from 25mm to 450mm section as per IS 4923 YST 310 Grade produced from iron ore and blast furnace route etc. as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position, making riveted/bolted/ welded connections and painting complete. 60 Providing and fixing colour coated Zincalume ( R ) AZ150 ( min 150 gms/sq.mt. total on each side ) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 mm Base Metal Thickness ( BMT ) (0.5 mm TCT ), Hi- strength steel with min.550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% aluminium 43.4% zinc 1.6% silicon) with COLORBOND ( R ) steel quality super durable polyester paint coat ( with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surfaceand nominal 10 um reverse coat on back surface. Profile sheet shall have nom. 950-1050 mm effective cover width and nominal 25-30 mm deep ribs with subtle square fluting in the five pan at nominal 180-250 mm center-to-center. The end rib shall be designed for anti-capillary groove. and return leg. The feed material should have coil manufacturers product details marked a regular interval. Including fasteners with min. fastened with min. 25 um Zinc-Tin alloy coated,Hex head, self-drilling screw etc. complete. (weight of profile 61 Providing water proof bedding for flooring of Bath and WC 25 mm thick in C.M. 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 year guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete 62 Providing and fixing mild steel grill railing 20 Kilogram/sq.m with teak wood hand rail of size 75mm x 60 mm.and sill of 75mm.x 25 mm.and newel posts for staircases, including fabricating, fix-tures, erecting, painting the grill work with one coat of anticorrosive paint and two coats of oil painting with approved colour and polishing the sill, hand rail and the newel post with french polish 63 Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in C.M.1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with C.M.1:3 admixed with approved water proofing compound and finally top finishing with average 20 mm. thick layers of same mortar added with jute fiber at 1Kilogramper bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300mm x 300 mm. making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rs. 500/- including ponding test etc. complete. 64 Providing, applying, fabricating and fixing panel of aluminium composite panel cladding in approved shape made out of 4 mm thick ACP sheet material consisting of 3mm thick FR grade mineral core following NBC part IV Fire and life safety (having 2 hours fire resistance in accordance to ASTM E119-12 and BS476 part 6 and 7 class O) sandwitched between two aluminium sheets (each 0.5 mm thick of AA 5005/AA3105 grade) The aluminium composite panel cladding sheet shall be coil coated with kynar 500 based PVDF/Lumiflon based fluropolymer resin (having 70:30 ratio of PVDF and acrylic) coating of approved colour and sg=hade on top face and polymer (service) coating of bottom face as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicon sealent, backer rods etc. overall weight of the ACP shall not be less than 7.5 Kilogram/ One Square Metre) 65 Providing and preparing kitchen otta up to 75 cm width, made up from 30 mm thick and 75 cm high vertical support for kadppa at 1 m. c/c of 25 mm thick both side polished kadappa middle shelf and bottom of 20 mm thick one side polished kadappa with facia patti of 20 x 50 mm kadappa including all material labour cutting fixing with cement mortar and araldite curing polished and cleaning etc. complete. 66 Providing and fixing heavy duty inter locking concrete Coloured paving blocks of 80 mm thickness of having a strength of 300 Kilogram/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc.complete 67 Providing and fixing 15 mm thick eco-friendly densified edge calcium silicate false ceiling of approved texture of size 595mm x 595mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanising at @12 gm/sq.m including both sides) consisting of main T runner suitably spaced at joints to get required length and size 24X38mm. made from 0.33mm thick (minimum) sheet, spaced 1200mm center to center and cross T of size 24X28mm made of 0.33mm thick(minimum ) sheet to be interlocked at the middle of the 1200x600 mm panel to form the grid of size 600x600mm resting on periphery walls/partitions on a perimeter wall angle precoated steel of size 24x24x3000 made of 0.4 mm thick (minimum) sheet with the help of all plugs at 450mm and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture (spintone/cosmos/hexa) in the grid, including light fittings, fixtures, smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling using 12.5mm dia. And 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanized steel levels clips of size 85x30x0.8mm, spaced at 1200mm center to center along main T bottom exposed with 24mm of all T-sections shall be prepainted with polyester baked paint, for all heights, as per specifications, drawings etc. complete.(currently this item should be used only for VIP cabins) 68 Providing and fixing mild steel grill gate as per the detailed drawing including hinges, locking arrangements and painting in three coats of oil paint of approved colour and shade etc. complete.(weight 18 Kilogram. to 20 Kilogram. Per Sq.m.) Spec.One Number: As directed by Engineer- in-charge. 69 Providing and erecting Y type barbed wire fencing with seven rows of wire with 2.45 mm dia G.I. pipe ( Rezan/ concentiDeleted ire 0.75 mm dia ) with hot dip and G.I. coated hooks as per drawing supported on M.S. angle 50 x 50 x 6 mm at 2.5 mtr. c/c including fixing and fastening with wire, painting M.S. angles with one coat of red lead primer and two coat of oil paint etc. complete. 70 Providing and laying in-situ M40 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver,compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method ( excluding reinforcement) approved by Engineer-in-charge. 71 Single Bed @ 2025LX 1000DX 650HProviding and fixing Single Bed of Size 2025Lx1000Dx650H with matress and pillow.Understructure: - The legs are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2 mm. The legs should have corner brackets welded to it at two levels. The corner brackets are made of 2mm thick CRCA having a L shaped structure to join the side panels and headboard to the leg. Three nos. of Horizontal stiffeners are provided at equal intervals. The stiffeners are made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. The middle Horizontal Stiffener has a leg attached to it to transfer the load to the ground and add to the strength and stability of the complete structure. This leg is also made of Square tube of size 25 x 25mm made out of MS with a thickness of 1.2mm. All Metal components to undergo 7 tank treatment process and should be powder coated to the thickness of minimum 50 Microns DFT.Side Panel: - The side panels are made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The overall width of the side panel is 150mm. The side panels have 18mm thick prelam particle board Baton running for required length to add rigidity to the structure. Head Board :- The head board is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 650mm. Foot Board :- The foot board is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The head board size to be considered as 1000 x 450mm.Bed Base: - The Bed Base is made up of 12mm thick Prelam Particle Board with both side laminate 72 Bed Side Table @ 400LX 400DX 415HProviding and Fixing Bed Side Table of size 400LX 400DX 415H The bed side unit is made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The bed side table has one drawer and one shelf. The shelf is made of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding 73 Wardrobe with Mirror @ 900LX 600DX 1965HProviding and Fixing Wardrobe with Mirror of size 900LX 600DX 1965H The wardrobe side panels and doors are made up of 18mm thick Prelam Particle Board with both side decorative laminate. All exposed edges are sealed with 2mm thick PVC edge Banding. The shelves are made of 18mm thick Prelam Particle Board with decorative laminate on both sides. The top is made of 36mm prelam particle board with decorative laminate on both sides. (18mm Prelam Particle board and 18mm batons on all sides to achieve 36mm overall thickness). The exposed edges of the top are sealed with 2mm thick PVC edge Banding. The top most part of the wardrobe has an aluminum hanger rod of EBCO make. One drawer of size 400(W) x 150(H) x 450 (D) made of 18mm thick prelam Particle Board has been considered. The drawer will have a multipurpose lock of EBCO premium make. The wardrobe handles are Satin SS finish of 160mm pitch. The wardrobe has a multipurpose lock of EBCO make. All hinges considered are Hettich make. Necessary good quality hardwares have been considered as required. 74 Providing & Arrangemnt of Mid Back, ECO CTS Mechanism , Fixed Armrest , Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Fabric Upholstery 75 NOMAD Interactive Screen: Providing and Fixing NOMAD Interactive Screen with storage. Specification size : 1260L X 500D X 1800H. Prior approval of Engineer in charge in necessary. 76 Providing & Arrangemnt of MId Back, Normal SyncroMechanism, Fixed Armrest, Gaslift for Seat height adjustment, Standard 5-prong/Nylon Base with Leather Upholstery. 77 Café Chrome 6 Seater Canteen tableSpecification : 1800L x 900D x 750H. Prelam Hydroshield Top with MS Understructure in Chrome finish 78 Tango Cafeteria Chair* Stackable Chairs* Without Arms* One Moulded Unbreakable Chair* Available Colors - White, Black, Green, Yellow, Red. 79 Double Bed (Compact 2 Nos.) Specification : 1980L X 900D X 450-750HMade inPrelam board with understorage 80 Full Height Steel Storage @ 750Lx450Dx2100HTProviding and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 4 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns as as per drawing. 81 Sofa Set 3+1+1Providing & fixing Sofa Set 3+1+1 Brown and Cream leather DIMENSION Length: 182.5 (cms) Breadth (cms): 100 (cms)Height (cms): 100 (cms) Weight (Kilograms): 66 (Kilogram) Seating Capacity: Five Seat 82 4 Seater Dining TableSpecification : 800L x 800D x 750H.Prelam Hydroshield Top 83 Stool for Lab and Class-IVProviding and fixing 4 legged Lab stool, Legs made of 16 Guage 45 MM Outer dimension MS Pipe, Duly painted, With a 304 Grade Stainless steel 12 inch wide seat with a 1 inch collar, Height adjustment via a screw. as per design and drawing and instructions of Engineer in charge. 84 Providing & Fixing Curviliner Workstation @ 1500/1500Lx600/600Dx750HT Providing & Fixing Curviliner Workstation @ 1500/1500Lx600/600Dx750HT, Curvilinear Table Top @ 1500/1500Lx600/600D :- TOP to be made of 25 mm thick Prelaminated particle board with PVC edge band, GABLE END to be made of 25 mm thick Prelaminated particle board with PVC edge band, KEYBOARD TRAY (WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, along with 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. 3 Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board. 85 Providing & Arrangemnt of High Back, Synchronized Mechanism with Multiple Locking, Adjustable Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery. 86 Providing & Arrangemnt of High Back Chair - TILT MECHANISM WITH MULTILOCKING, HIGH DENSITY CUSHION ON SEAT COMPOSITE LEATHER WITH METALLIC SILVER FINISH BASE AND ARMS WITH P.U.CASTORS GASLIFT FOR HEIGHT ADJUSTMENT. 87 Multiple Compartment Lockers @ 1140Lx 457D x 1830 mm. Ht. Providing and fixing Multiple Compartment Lockers @ 1140Lx 457D x 1830 mm. Ht. with 12 Compartments, Complete body & shutter made of CRCA Sheet with powder coated finish as per approved color. 88 Public Seating Chair. - 3 SeaterProviding and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish. 89 12 Seater Reading Table for Library @3600Lx1200Dx750HTProviding and Fixing 12 Seater Reading Table for Liberary @ 3600Lx1200Dx750HT Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Gable Ends : made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine.Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine. 90 Alluminium foldable ladder for store Providing & Fixing Foldable Alluminum Ladder 1500 mm. Ht. 91 Library Area Table @ 1350Lx750Dx750HTProviding & Fixing of FREE STANDING TABLE @ 1350Lx750Dx 750HT:- TOP to be made of 25 mm thick Prelaminated particle board with PVC edge band, BENT LEG to be CHROME FINISH as per drawing. 92 CHILDREN TRIANGLE TABLESize: 1300L x 1300LX1300L x 400H Specifications Table Top: 25mm thick Pre laminate particle board with 2mm PVC edge lipping on all exposed edges Support: End Legs: MS powder coated PERFORM 50 X 50 Leg with support beam. Intermediate Legs: MS Powder coated 60X40mm legs And Support Leg on Fixed Pedestal and supporting MS cross beams (40X20 mm) 93 CHILDREN CHAIR Size:400LX 400L Specifications Table Top: 25mm thick Pre laminate particle board with 2mm PVC edge lipping on all exposed edges Support: End Legs: MS powder coated PERFORM 50 X 50 Leg with support beam. Intermediate Legs: MS Powder coated 60X40mm legs And Support Leg on Fixed Pedestal and supporting MS cross beams (40X20 mm) 94 CHILDREN SHELF Size:2560LX 400D SpecificationsTable Top: 25mm thick Pre laminate particle board with 2mm PVC edge lipping on all exposed edges Support:End Legs: MS powder coated PERFORM 50 X 50 Leg with support beam. Intermediate Legs: MS Powder coated 60X40mm legs And Support Leg on Fixed Pedestal and supporting MS cross beams (40X20 mm) 95 Executives Table @ 1800Lx900Dx750HTProviding & Fixing of Table @ 1800Lx900Dx750HT - TOP & GABLE END to be made of Membrane finish with soft water fall edges & curved panel & Decorated Anodized section MODESTY PANEL to be made of 18 mm thick Prelaminated particle board with PVC edge band as per drawing. 96 CHILDREN CRIB Size:1000LX 650D SpecificationsTable Top: 25mm thick Pre laminate particle board with 2mm PVC edge lipping on all exposed edges Support: End Legs: MS powder coated PERFORM 50 X 50 Leg with support beam. Intermediate Legs: MS Powder coated 60X40mm legs And Support Leg on Fixed Pedestal and supporting MS cross beams (40X20 mm) 97 Supplying anderectingPVCtrunking (PVCcasing-n-capping)ofsize25 mm with accessorieson wall/ceiling as per specification No: WG-MA/CON. 98 Supplying anderectingPVCtrunking (PVCcasing-n-capping)ofsize32 mm with accessorieson wall/ceiling as per specification No: WG-MA/CON. 99 Supplying and erecting PVCboxtrunking ofsize50x50 mm. with accessorieson wall/ceiling as per specification No: WG-MA/BOX(1-2-11) 100 Supplying and erecting mains with 2x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW(1-3-1) 101 Supplying and erecting green colour earthing with 1x 1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW(1-3-1) 102 Supplying and erecting mains with 2x2.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(1-3-2) 103 Supplying and erecting green colour earthing with 1x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(1-3-2) 104 Supplying and erecting mains with 4x 4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(1-3-3) 105 Supplying and erecting green colour earthing with 1x 4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(1-3-3) 106 Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW 107 Supplying and erecting mains with 4x 6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(1-3-4) 108 Supplying and erecting green colour earthing with 1x 6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(1-3-4) 109 Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.(1-6-1) 110 Supplying and erecting modular type switch 16Aduly erected on provided plate and box with wiring connections complete.(1-6-2) 111 Supplying and erecting modular type 3 pin 6Amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete.(1-6-10) 112 Supplying and erecting modular type 3 pin 6 / 16Amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete.(1-6-11) 113 Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.(1-6-23) 114 Supplying and erecting modular type blanking plate one module, duly erected on provided plate & box.(1-6-24) 115 Supplying and erecting PVC Surface modular switch box with double mounting plate for 3module duly erected. 116 Supplying and erecting PVC Surface modular switch box with double mounting plate for 6module duly erected. 117 Supplying and erecting PVC Surface modular switch box with double mounting plate for 12module duly erected. 118 Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthingand required accessories as per specification No: WG-PW/SW 119 Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthingand required accessories as per specification No: WG-PW/SW 120 Wiring for plug on board withSwitch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW(1-7-26) 121 Supplying and erectingLED square / circular Max. 25 W down lighter/ Panel Light having pressure die-cast aluminium housing,polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50,including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 122 Supplying and erectingLEDPanel Light(600mm X 600mm) Max. 30 Whaving CRCA powder coated housing,polystyrene diffuser havingsystem lumens output of Min. 3600 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 123 Supplying and erecting bulk head LED fittingmax. 10Wwith high transitivity diffuser withsystem lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg.,THD<10%,p.f. >0.95, operating range of140-260V, in built surge protection of 2.5 kV, Life class of50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.(2-1-15) 124 Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12Wwith high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%,THD<10%,p.f. >0.95, operating range of200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty.(2-1-16) 125 Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22Wwith high transitivity diffuser withsystem lumens output ofMin.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%,THD<10%,p.f. >0.95, operating range of200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. 126 Supplying and erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt,CRI>80, CCT of 6500K and THD<=20% havinguseful life of minimum 25000 hrs. with overheating protection with 2 years warranty.(2-1-22) 127 Supplying and erecting ding dong / electronic musical type call bell with heavy duty coilsuitable to operate on 230V A.C. supply erected on polished double wooden block/sunmica block of suitable size.(2-3-13) 128 Supplying and erecting Electronic type cordlesscallbell erected on T.W.board havingportablebellpush working on 9V D.C. battery and(effective range upto 45 meter) bell on 250 V A.C. supply.(2-3-15) 129 Supplying and erecting integrated LED Highbay Fitting70W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics,having system lumens output of Min.10000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-240V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L50B50 , including driver complete with 3 Year warranty as per specification NoFG-ODF/FLS2. 130 Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected, complete.2(-10-13) 131 Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% without IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF(2-10-22) 132 Supplying & fixing anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 133 Supplying and erecting ‘B’ class G.I .pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.(2-11-6) 134 Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. AP-WCR/WC(3-3-9) 135 Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200)(3-5-1) 136 Supplying, installing, testing and commissioning of3 kVA capacity online pure sine wave with backup time of 1 hrs. PWM & IGBT based UPS with 0.9 to unity output pf, single phase input & 1 phase output complete with all protectionsas per specification no. AP-UPS(3-7-3) 137 Supplying and erecting 12V/26Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete.(3-8-9) 138 Providing and erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware.(7-11-6) 139 Providing and erecting hot dipped galvanised ladder type cable traymanufactured from 16 SWG (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware.(7-11-8) 140 Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP(9-1-1) 141 Supplying, erectingandmarking SPMCB 6A to 32A, C-serieswith rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB(5-3-2) 142 Supplying, erectingandmarking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB(5-3-3) 143 Supplying, erectingandmarking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB(5-3-10) 144 Supplying, erectingandmarking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB(5-3-11) 145 Supplying and erecting triplepole and neutral distribution board (TPNDB),SPMCB of 4 ways/phase(12 poles), with door,1.2mm thickness, surface/flush mounted, IP 43 protection on iron/GIframe (horizontal busbar type) as per specification no. SW-SWR/MCBDB(5-4-1) 146 Supplying&erectingtriplepoleand neutral distribution board (TPNDB), SP/TP MCBs total 8 ways /24 poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB 147 Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole/4 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), withdoor, 1.2mm thickness, surface/flush mounted, on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 148 Supplying and erecting single pole and neutral distributionboard (SPNDB), with 2 ways for incoming and 10 ways (10 poles) for outgoing SP MCBs,with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW SWR/MCBDB(5-4-9) 149 Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.(5-4-13) 150 Supplying, erecting & commissioning 4 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB 151 Supplying, Erecting and Commissioning of4 pole RCCB 40A, electromagnetictype with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB(5-6-5) 152 Supplying, fixing, and commissioning 2 pole, RCBO 6/10/16/20/25A,with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO(5-6-9) 153 Providing and erecting 4 Pole MCCB,100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB(5-5-1) 154 Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 155 Providing and erecting 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB(5-5-4) 156 Supplying and erecting metal work in CRCA sheet including Iron work for supportswith fabrication ofboxes,panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete.(6-1-1) 157 Supplying and erecting iron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority.(6-1-19) 158 Supplying and erecting self-locking arrangement with keys in duplicate, made of brass of grade 1 compliance to IS 729-1979 duly erected, flush with surface of panel / cupboard(6-1-20) 159 Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity 99.9% aluminium purity with E91E Grade as per IS 5082 & Current Density 0.8 A per sq. mm. with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCP-BB 160 Supplying and erecting panelmountingtypedigital ammeterhavingthreeandhalfdigitLEDdisplay, externalCToperated,calibratedfor suitable to operate on 500V, 0 to 1000Ahaving accuracy class of 0.5, AC supply with necessary PVC wire leads and lugs andmounting hardware on provided panel complete with calibration certificate from manufacturer.(6-3-7) 161 Supplying and erecting panelmountingtypedigital voltmeterhavingthreeandhalfdigitLEDdisplay, calibrated for 0 to 750V AC suitable to operate on 500V having accuracy class of 0.5,AC supplywithnecessaryPVCwireleadsandlugsand mountinghardwareonprovidedpanelcompletewith calibration certificate from manufacturer.(6-3-8) 162 Supplying and erecting AC Three Phase Four wire Multifunction Energy Meter of Rating 10 - 60A, Class 1.0 with din rail / Panelmounting to measures and displayparameters with RS485 Modbus communication port. mounting whole current operated meter to measures and display V, I,kWh, KVAh, KW, KVA, P.F, THD, RS 485 Communication port. Electrical parameters shall be available on com port with their mapping address open for third party software(6-3-19) 163 Supplying and erecting selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box / panel and duly connecting with necessary PVC wire leads and lugs. 164 Supplying and erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on providedbox / panelwith necessary material, wiring & connections etc.(6-5-5) 165 Supplying and erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.(6-5-6) 166 Supplying and erecting 50 kVAr,3 phase, 50 Hz., Power contactors Derated for microprocessor APFC controller with MPP / APP type capacitor with 525 Vand having minimum overcurrent capacity of 1.8 In,peak inrush current capacity 300 Inand minimum life 150000 hours with , consisting of suitable steps of MPP / APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection, as per specification no CP-ED/APFC 167 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core10sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 168 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core25sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 169 Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core35sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL (7-1-31) 170 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 95sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 171 Supplying and erecting modular type telephone socket one gang with safety shutter, duly erected on provided plate and box with wiring connections complete(1-6-15) 172 Supplying & erecting20 pair telephone copper cable 0.5 mm dia. with high density polyethylene insulation, polyester taped, Nylon Rip Cord & grey colour sheathed with FR PVC, conforming to ITD specification S/WS 113C laid in provided PVC casing capping/conduit as perspecification No. WG-TW 173 Supplying & erecting 50 pair, 0.5 mm dia. jelly filled armoured telephonecopper cable with poly-al laminate moisture barrier, polythene sheathed, G.S.Tape armoured polythene jacketed havinglaid in provided trench as per specification No. WG-TW 174 Supplying, erecting & commissioningMDF Box 50x50 pairs made from min. 1.5mm thick MS sheet as per specification no. WG-TW 175 Supplying, erecting & commissioning 20 pairs FR junction box with moulded plastic enclosure as per specification no. WG-TW 176 Supplying, erecting & commissioning 10 pair module for connection & disconnection of telephone cable as per specification no. WG-TW(1-9-18) 177 Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of6 x 32 extensions suitable upto 96 extensions complete. 178 Supplying, Erecting and Commissioning ofpush button telephone instrument desk top/wall mount with caller ID & Speaker unit as per specification complete.(1-9-29) 179 Supplying, Erecting and Commissioning ofIP telephone instrument as per specification complete.(1-9-30) 180 Supplying and erecting unbreakable concealed typemodular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.(1-6-34) 181 Supplying and erecting 20m HDMI cord low voltage grademinimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete. 182 Supplying and installingcat-6 cable suitable for networking as per specification no. WG-COC/NC(1-10-1) 183 Supplying and erecting LSZH armoured multimode Optical Fibre Cable with 24 fibres, core dia 50/125 µm (OM4) suitable up to 10 GBPS ethernet distance at 850 nm of wavelength, on wall/ceiling or laid in provided pipe/trench as per specification No. WG-COC/OFC 184 Supplying and fixing1 m length, UTP patch cord of enhanced Cat 6 type with 4-connector channel, performance test report as per ANSI/TIA-568.2-Din position as per specification No. WG-COC/PC(1-10-17) 185 Supplying and fixing3 m UTP patch cord of enhanced Cat 6 type with 4-connector channel, performance test report as per ANSI/TIA-568.2-Din position as per specification No. WG-COC/PC(1-10-20) 186 Supplying, fixing, and configuring24 ports with 4 (SFP+) port, ethernet managed switch with web view/CLI, 6KV surge protection on ethernet port and console port for management in provided rack as per specification no. WG-NWC/GBS(1-11-4) 187 Supplying, fixing, and configuring broadband ADSL router with all accessories, on provided rack as per specification No. WG-NWC/ADSL 188 Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.(1-12-1) 189 Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO 190 Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP 191 Supplying and fixing9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK(1-12-18) 192 Supplying, installing, testing and commissioning of Commercial Heat pump, having dimension: 1020 x 846 x 1840 (mm), Input power: 6.02 kW, 400 V, 3 Ph, 50 Hz, Output power: 19.8 kW having hot water temperature range 35°C to 52°C and ambient temperature range for max. efficiency 7°C to 43°C, centrally controlled operation, operational noise level: 65 dBA with necessary accessories complete with 5 years ON-SITE warranty. 193 Supplying, installation and testing and commissioning of storage type Mild Steel mixing water tank of capacity 5000 ltrs. tested to a pressure of 8 kg/cm2, insulated with 50 mm thick rock wool with wire mesh around and cladded with 26 SWG aluminium of dish end type with working pressure of 6 kg/cm2, fabricatedwith 6 mm thick plate and dished ends with 8 mm thick plates complete with man hole cover, inner side of the tank coated with FRP coating of 3 mm thickness withstand temperature of 90°C provided with collars of 2 BSP forprovision toinstall6 numbers of electrical heating coils if required with thermal sensors for automatic operation and integrated into the electrical circuits of the circulation pumps and the heat pump with safety valve drain, inlet and outlet nozzle, pressure gauge with all necessary accessories complete. 194 Supplying,erecting, testing and commissioning of10kW, 3 x 3.3 KW AC Electric Vehicle charger (suitable for 2/3/4 wheeler) havingminimum IK08/IP 54 Protection suitable for three phase, 415V AC, 50Hzincoming and 3 nos. output as per IEC 60309 industrial sockets having capacity of output current of 16A 240V ACat each socket with 3.5TFT touch screen for human interface & LED Light for status indication and metering for measurement of consumed energy having metering accuracy +/-1%, one hour battery backup for communication, emergency push stop button and having short circuit, over & under voltage, overload, over temperature, earth leakage protection and enclosure made of minimum 1.5mmduly RAL7035 Coated M.S, Erected oniron/GI frame on provided cement concrete foundation complete with one year on site warranty, confirming toIS 17017 Series as per specification. 195 Supplyinganderecting Biometric Access Control System working on 230V A.C. supply with resetting arrangement complete erected 196 Supplying, erectingandmarking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB(5-3-11) 197 Supplying, fixing, and commissioning MCB type change over switch 4 pole, 40A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR / MCBCOS(5-3-25) 198 Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.(5-4-13) 199 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core6sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL(7-1-27) 200 Supplying and erecting G.I. pipe‘A’ class 40 mmdia.erectedfor enclosingXLPEarmouredcable on wall/poleas per specification no. CB-CE(7-6-2) 201 Supplying and laying (including excavation)of suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugatedpipes(DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete.(7-6-9) 202 Providing earthing with galvanizediron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. covercomplete with all materials, testing & recording the results asper specification no. EA-EP(9-1-3) 203 Providing pipetype earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rodcomplete with all materials testing and recording the results as per specification no. EA-EP(9-1-4) 204 Supplying and erecting minimum Three & above star rated submersible pump set of 2.25 KW/3 HP with 415 V, 50 c/s AC supply suitable for 100 mm dia. borewell suitable for 60 to 170 LPM discharge at 97 to 30 m head & discharge & delivery pipe of Size-40 mm diameter with a necessary H type clamps as per specification No. WP-SMP 205 Supplying and erecting minimum Three & above star rated submersiblepump set suitable for erection on open well of 3.75 KW/5 HP with 415 V 50c/s. A.C. supply, having delivery head from 43 to 11m and discharge from 120 to 840 litres. per minute & pipe of Suction 65mm / Delivery 50 mmdiameter erected with necessary H type clamps as per specification No. WP-OSP(12-3-2) 206 Supplying and erecting D.O.L Starter suitable for 415 V, 3 phase 50 cycles with no volt coil and overload elementwith necessary materials and connected to supply up to 7.5 H.P.(12-4-2) 207 Supplying and erecting flat flexible 3 core 2.5 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.(12-4-8) 208 Supplying and erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.(12-4-9) 209 Supplying and erecting Water level controller 230/415 V, A.C. , Four way under ground & Over head tank operation only.(12-4-15) 210 Supplying and erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc .(12-4-17) 211 Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete.(16-1-5) 212 Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (pole muffing or any other purpose).(16-3-7) 213 Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete as per specification no. CW-PLB/GP.(16-5-6) 214 Supplying and erecting high density polythene pipe ISI mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected tojet/submersible pump with required material complete.(16-5-18) 215 Supplying and erecting 50 mm dia. gun metal sluice valve at position with necessary materials complete.(16-6-15) 216 Supplying and erecting non return valve 50 mm dia in position made of gun metal complete.(16-6-21) 217 Providing and erecting 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB(5-5-4) 218 Supplying, installation, testing and commissioning extendable/non-extendable indoor type 11 kV, 630A,load break switch, compliant to IEC 62271 -100, 200 and 102, on provided MS channels/trench/foundations per specification no SW-HTS / LBS 219 Supplying and erecting GI sheet 1.6mm (16 SWG) caution board of size 250 x 200 mm duly painted with red oxide and enamel paint in Marathi, Hindi and English erected at position for HV/EHV (11000 Volts) installation with compliance to IS 2551-1982(6-1-16) 220 Supplying,erecting,testing and commissioning 11KV HT metering cubical (compact / vertical type) approved by MSEDCL / licensee fabricated with 2 mm (14 SWG) M.S. sheets with supporting angle, painted with powder coating / epoxy paintof required shade, copper bus bar size 25 x 6 mm, heavy duty mechanical lock, with counter meter for measuring no of times the opening of meter door, top side cover (CT, PT cover) interlock with meter door, epoxy casted 3 nos. CT having required ratio between 50/5A to 200/5A, VA 10 or 15, Class 0.2S, epoxy casted 3 nos. PT having ratio 11000/V3/110/V3 VA 50, Class 0.2 suitable for provided trivector meter, andprovision for incoming and outgoing cables complete duly tested by licensee with necessary test certificatesand erected on provided plinth/ cc foundation. 221 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core300 sq. mm. aluminiumconductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 222 Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(E), 3 x 150 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT 223 Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT 224 Providing and erecting Heat shrinkable outdoor termination kit for 11 kV ( E ) XLPE HT cable 3x120 to 185 sq. mm. with necessary material as per specification no. CB-JT/HT 225 Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. 226 Supplying and erecting rolled steel joist (girder) pole 100 x 116 mm (23 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ(8-1-13) (11 mtr x 2 Pole =22) 227 Supplying and erecting single pole cut point channel set of for 11kV HT OH line two channel of size 100x50x6mm 1.6m long having stud angle of size 50x50x6mm 1.5m long with necessary clamps, nut bolts etc. complete as per drawing.(8-3-17) 228 Supplying and erecting porcelain disc type insulator 45KN with necessary hardware suitable for 11kV line, complete as per specification no. OH-INS/DI 229 Supplying and erecting porcelain pin type insulator with GI pin suitable for 11kV line, complete asper specification no. OH-INS/PN 230 Supplying and erecting distribution class, 11 kV thyrite type lightening arrester with nut bolts, on provided MS channel as per specification no. OH-INS/LA 231 Supplying and erecting pole clamp made from 50x6mm MS flat for pole or pipe, post erected with 15mm bolts and nuts duly painted with one coat of red oxide and two coats of aluminium paint complete. 232 Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP(9- 1-1) 233 Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clampsfixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.(9-2-3) 234 Supplying, installing, testing & commissioning 3 phase,11/0.433 kV,50 Hz., 250 kVA, Mineral oil immersed and naturally cooledoutdoor type, Copper wound, without gas cushioning , hermetically Sealedtransformer, delta/star connected with additional neutral brought out on load side, temperature rise should not Exceed 45℃ by thermometer in oil and 50℃ by the resistance methodin winding at full load rating, with HV tapping (with off load tap changer) off load +5 to -10 in steps of 2.5%, having 7 number of tap positions , with standard accessories complete with test certificate with losses below 980 Watts at 50% load, 2930 Watts at 100%load as perIS:1180 (part 1) : 2014 , with necessary permissions of Electrical Inspector, as per specification no SS- TR-SL 235 Supplying and erecting11 kV outdoor type gang operated airbreak,triple pole switch 400 A capacitywith3postpin type insulator per phase, mounted in horizontalor vertical position with necessary channels on providedcrossarmwithadequate length of C class G.l. pipe for operating handle erectedonextendedsquareshaft. Theoperatinghandle provided with lock and key at suitable heightfrom ground level with necessary clamp. 236 Supplying and erecting, 11 kV outdoor type drop out fuse with insulator complete with fuse holders, fusebarrelwithmetalfitting,fuse elementmounted onM.S.channel with working currentof15A capacity complete erected on provided cross arm. 237 Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG(10-6-18) 238 Supplying and erecting 50 x 50 x 6 mm angle iron as cornersupport 2m long fixed at the middle ofthefencing frame and the otherside inclined at 30 degree angle, in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminium paint complete.(10-6-19) 239 Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation, and painted complete as per specification no SS-AS/DLD(10-6-20) 240 Supplying & erecting barbed wire two ply with 12 SWG ply and 12 SWG barb with a gap between two bars of 75 mm. firmly fixed on provided angle supports with necessary materials complete. (6.044 meters/kg.). 241 Providing printed instruction chart for treating persons suffering from electric shock, printedinEnglish & Marathi and duly laminated complete.(10-6-22) 242 Providing pair ofdulytestedrubber hand glovesas per IS :47705suitable forworking up to 22 kV supply complete.(10-6-23) 243 Supplying standardfirst aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage (Band-Aid) adhesive tape for medicinal use, scissors, anti-septic solution, etc. (All above contents shall be of standard makes)(10-6-24) 244 Supplying and fixingPVC synthetic elastomerelectrically insulating matwith class C insulation conforming to IS: 15652 – 2006 tested having 3mm thickness up to 33 kV 245 Supplying shock proof leather safety shoes of electrical grade of standard size as IS :11226, 14544duly tested, with necessary test certificate from manufacturer.(10-6-28) 246 Supplying and spreading stone metal 25 mm size for 100 mm depth above the ground level complete. 247 Excavating hard murum / stone metal roadby chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site as required complete.(16-1-6) 248 Makingtransformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm. thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12 mm thick including watering etc complete. 249 Makingcement concrete foundation including excavation(60 x 60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal,45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete. (for above 9 m poles)(16-3-4) 250 Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (pole muffing or any other purpose).(16-3-7) 251 MSEDCL Charges 252 Providing and erecting 4 Pole MCCB 415V, 400A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure /panel as per specification no. SW-SWR/MCCB(5-5-4) 253 Supplying and erecting SS enclosure for MCCB suitable for above 250 A up to 800A MCCB.(5-11-19) 254 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core300 sq. mm. aluminiumconductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 255 Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete. 256 Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP(9-1-1) 257 Supplying, erecting, testing and commissioning of diesel generating set with alternator of 250 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply,a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 42.30 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 425 Ltr etc. on provided M20 Grade CC Foundation and obtaining necessary approval from Electrical Inspectoras per specification no. GEN-DG 258 Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 200 kVA up to 250 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. 259 Excavating hard murum / stone metal roadby chiselling for preparing pit for poles stay or earth plates or for laying cables, pipes & clearing the site by removing debris & making the site as required complete.(16-1-6) 260 Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (pole muffing or any other purpose).(16-3-7) 261 Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi strandedcopper Industrial cable for voltage grade up to 1.1 kV(1-3-14) 262 Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2. 263 Supplying and erecting three phase, 415V, street light control panel up to the max load of 6kW, TPN MCB 40A,powder coated CRCA 14 SWG sheet, outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up,auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation, with overcurrent, short circuit, earth fault protectionon provided iron frame / CC foundation.(5-2-5) 264 Supplying, erectingandmarking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kAin provided distribution board as per specification no. SW-SWR/MCB(5-3-1) 265 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core6sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 266 Supplying and laying (including excavation)of suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugatedpipes(DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete.(7-6-9) 267 Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL 268 Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT(8-2-21) 269 Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT 270 Providing earthing with galvanizediron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. covercomplete with all materials, testing & recording the results asper specification no. EA-EP(9-1-3) 271 Providing pipetype earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rodcomplete with all materials testing and recording the results as per specification no. EA-EP(9-1-4) 272 Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clampsfixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.(9-2-3) 273 MakingM- 20 grade reinforced cement concretefoundation by considering the safe soil bearing capacity at site as 10 T/sq.mat 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole). 274 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core10sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 275 Supplying, installation, testing and commissioning of booster fire pump[BP] suitable for water discharge of 900 LPM at 35 m head driven by electric motor 415 volts, 3 phase 50 Hz, AC supply of7.5 kW or of suitable kW capacityfor manual/automatic operation and consisting of following :(a) Horizontal/vertical type, single/multi stage, centrifugal casing pump of cast iron body & bronze/CI impeller with stainless steel shaft (SS410 grade), mechanical seal conforming to IS 1520.(b) Squirrel cage induction motor, TEFC, synchronous speed 3000 RPM, suitable for operation onwith IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325.(c) M.S. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(d)Erected on provided suitable size cement concretefoundation duly plastered with anti vibration pads with perfect aligning, properlevelling complete pump set with accessories duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete, as per specification no. FF-MFP/BP 276 Supplying and erectingG.I. pipe‘C’ class ERW25 mm dia with necessary fittings complete asper specification no. FF-PP 277 Supplying and erectingG.I. pipe‘C’ class ERW50 mm dia with necessary fittings complete asper specification no. FF-PP 278 Supplying and erectingG.I. pipe‘C’ class ERW65 mm dia with necessary fittings complete asper specification no. FF-PP 279 Supplying and erectingG.I. pipe‘C’ class ERW75/80 mm dia with necessary fittings complete asper specification no. FF-PP 280 Supplying and erecting G.I. pipe‘C’ class ERW100 mm dia with necessary fittings complete asper specification no. FF-PP(13-6-6) 281 Supplying and erecting G.I. pipe‘C’ class ERW150 mm dia with necessary fittings complete asper specification no. FF-PP(13-6-7) 282 Providing G.I. pipe‘C’ class ERW200 mm dia with necessary fittings complete asper specification no. FF-PP(13-6-8) 283 Providing coating of bitumen paint &4mm thick wrapping for underground 150 mm ring main of fire fighting system.(13-6-10) 284 Supplying and erecting 100 mm dia cast iron foot valve ball type/flap typewith strainer for negative suction complete asper specification no. FF-VL/FV(13-7-2) 285 Supplying and erecting 100mm dia.castiron double flange sluicevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/SV(13-7-14) 286 Supplying and erecting 150mm dia.castiron double flange sluicevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/SV(13-7-15) 287 Supplyinganderecting200mm dia.castiron double flange sluicevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/SV 288 Supplying and erecting 100 mm diacast iron double flange NRV complete with PN16 pressure rating, asper specification no. FF-VL/NRV(13-7-24) 289 Supplying and erecting 25 mmdiagunmetal gatevalvecomplete with PN16 pressure rating, asper specification no. FF-VL/GV(13-7-32) 290 Supplying and erecting stainless steel single outlethydrantvalve fitted with necessary accessories complete asper specification no. FF-VL/HV(13-7-35) 291 Supplying and installingone piece moulded HDPE / fibre water tank for negative suction only, having capacity 1000litres fitted with necessary accessories complete asper specification no. FF-FFA/PT(13-8-1) 292 Supplying and installingwall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose)along with necessary accessories complete asper specification no. FF-FFA/HV(13-8-2) 293 Supplying and erecting 63mm dia, reinforced rubber lined (R.R.L.) hose pipe,15m inlength, fitted with necessary accessories complete asper specification no. FF-FFA/RRL(13-8-4) 294 Supplying and erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzlecomplete as per specifications no. FF-FFA/NZ(13-8-8) 295 Supplying and erecting fire brigade header ( Siamese connection )of 150 mm dia, for supplying water in fire tank complete asper specification no. FF-FA/FMC(13-8-11) 296 Supplying and erecting 300 mm dia 1.5min heightair vessel / tankfabricated from min 5mm thick M.S. sheet complete asper specification no. FF-FFA/ACT(13-8-12) 297 Supplying and erecting 20/25mm dia gun metal air release cock, with necessary G.I.coupling to be fitted on top of air vessel or on wet riser complete asper specification no. FF-FFA/ARV(13-8-13) 298 Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I. pipe, elbow etc. complete asper specification no. FF-FFA/PG(13-8-14) 299 Supplying and erecting 12/15 mm dia pressureswitchwith provided isolationvalve,G.I. nipple, elbow, etc complete asper specification no. FF-FFA/PS(13-8-15) 300 Supplying and erecting brass orifice plate having 6 mm. thickness, 140 mm outer diawith required diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP(13-8-16) 301 Supplying and erecting M.S./CRCA cabinet for housing single hydrant valveof size ( 400 x 400 x 400)mm or hose pipe boxof size (600 x 600 x 200)mm made from min. 1.5 mm thick CRCA sheet with angle iron work of min. of size (25 x 25 x 4) mmhaving front doors with viewing glass of size (200x150) mmandlockingarrangement with necessary fixingmaterialsuch as rubber biddingetc. dulypainted in post box red colour( Code 538 of IS 5)(13-8-18) 302 Supplying and erecting M.S./CRCA cabinet forhousing FireBrigade / SIEMESE connections (size 1250 x 400 x 300 mm.) made from 16 SWG sheet andangleiron 25 mm. x 25 mm. x 4 mm. having front doors with viewing glass (8 x 6) andlocking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour( Code 538 of IS 5)(13-8-19) 303 Supplying, erecting, testing and commissioning of quartzoid bulb sprinkler, 15 mm (½) dia. NBCM Body chrome finished, 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR. 304 Supplying, erecting, testing and commissioning ofvane type water flow detector75/80 mm dia. with1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4)Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes.(13-12-2) 305 Supplying and erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete.(13-15-1) 306 Supplying, installing, testing and commissioning ofmanual call point (Pill box) with break glass push button andflip abort switch or agent release switch in metal enclosure complete asper specification no. FF-FAAS/MCP(13-9-7) 307 Supplying, installing, testing and commissioning ofhooters having high (100dB @ 1m) and low (94dB @ 1m) volume setting, group addressing facility allowing multiple sounders to be activated with CRCA enclosure complete asper specification no. FF-FAAS/HTR(13-9-8) 308 Supplying, installing, testing and commissioning ofFRLSXLPE armouredcable 2 core1.5 sq.mm. copper conductorcomplete erected on wall/ ceiling complete asper specification no. CB-LT/CU(13-9-10) 309 Supplying, installing, testing and commissioning of2 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories , 16x2CharacterLCDDisplay, provision for zone wise contact and beep sound alarm, suitable to operate on 120-220 V AC,0 - 49 Deg C,93 ± 2 Percentage RH (non- condensing) at 32± 2 Deg C complete asper specification no. FF-FAAS/FACP(13-9-14) 310 Supplying, erecting, testing and commissioning of120 W amplifiersuitable to operate on 230VoltsA.C. / 12VoltsD.C. supply complete asper specification no. FF-PA/AFR(13-11-1) 311 Supplying, erecting, testing and commissioning of15 to 30 Watts soundcolumn or ceiling mounted complete asper specification no. FF-PA/SOC(13-11-2) 312 Supplying, erecting, testing and commissioning ofstand mounted/handheld type wired microphone having 2 mV/Pa sensitivity, impedance level limit 300 ohms and 50 - 16000 Hz suitable to operate in -10 deg C to +55 deg C with min. 7 metreshielded cable and 3 Pin Professional XLR Connector, stereo jack complete asper specification no.FF-PA/MIC(13-11-3) 313 Supplying, erecting, testing and commissioning ofrust free microphone floor stand of chrome plating/powder coating or S.S. material , 500 mm to 1500 mmheight and sturdy mechanism ensuring trouble free movement complete.(13-11-4) 314 Supplying, erecting, testing and commissioning ofrust free microphone table stand of chrome plating/powder coating or S.S. material,up to 500 mm height and suitable base for sturdy mechanism ensuring trouble free movement complete.(13-11-5) 315 Supplying, erecting, testing and commissioning of2 core shielded cable complete asper specification no.FF-PA/MCC(13-11-6) 316 Supplying, erecting, testing and commissioning of1.5 sq. mm speaker wire complete.(13-11-10) 317 Supplying, installation, testing and commissioning of 220/250Volts, single phase, 50 Hz Siren of 3.25 km range (Diametrical),horizontaldoublemountingtype of0.5 HP 6000 RPMon C. C.foundation complete as per specification no. SRN-AS/SM 318 Supplying and erecting ABC powder type fire exitinguisher as per IS: 13849/15683 of 6 kg capacity with necessary clamp for erection on wall (Non-CSR) 319 Supplying and Installation auto glow (Viewing up to 15 Mtr length) fire signages in PVC/Vinyl 4/6 mm thick sheet or as per sample approved by client viz fire doors, fire hose box, fire & electrical safety etc. Size 300 mm X 100 mmas per IS 12349-1988 320 Supplying and Installation auto glow (Viewing up to 15 Mtr length) fir signages in PVC/Vinyl 4/6 mm thick sheet or as per sample approved by client viz fire doors, fire hose box, fire & electrical safety etc. Size 450 mm X 100 mm as per IS 12349-1988 321 Providing and fixing of Emergency Exit Lights LED Beam-II with exit high glow LED White lamps working on battery 12 V 7.6 Ah for duration 4-5 hours (approx) wattage of LED lamp is 26 watt each 2 Nos. of lamp total wattage 52 Watts Weight of unit will be 5.4 kg input voltage 220 V AC 50 Hz Output Volatge 12 V DC the outer cabinet is powder coated, for safety purpose DC & AC fuse system is given in unit as per IS 9583-1981 322 Supplying and erectingHMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. 323 Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC. 324 Supplying and erecting 20mm dia. corrugated flexiblepolypropylene conduit 325 Supplying and erecting 10m HDMI cord low voltage grademinimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete.. 326 Supplying and installingcat-6 cable suitable for networking as per specification no. WG-COC/NC 327 Supplying, fixing, and configuring 24 ports, POE switch in provided rack as perspecification No. WG-NWC/ENS(1-11-3) 328 Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC. 329 Supplying and fixing POE adaptor to provide DC supply to ethernet devices as per specification No. WG-NAS/PEA 330 Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 500x600x500 mm) as per specification No. WG-NAS/RAK 331 Supplying, erecting, testing and commissioning of single phase input & 1 phase output 1 kVA capacity online pure sine wave UPS, with backup time of 1 hrs. PWM & IGBT based,with 0.8 to unity output pf complete with all protections as per specification no. AP-UPS 332 Supplying and erecting 12V/100Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete.(3-8-12) 333 Supplying & erecting of High definition 4/5 Megapixel IP IR Dome Camerawith following featuresImage Sensor : minimum 1/2.8 Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520Video Compression : H.264, H.265 or higher, at least Three individuallyconfigurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View :2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129°4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102°6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65°Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White,0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain,white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D DigitalNoise Reduction, Automatic White Balance, Automatic Gain Control, BacklightCompensation, Highlight Compensation.Events : Privacy Masking, Motion detection, Scene change detection, Facecapture, Video tampering, audio exception detection, Region entrance detection,Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X,digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed,FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP,SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour,SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalentBIS/TECH/STQC or any indian standards as applicable, CE, FCC certified.duly erected in position on wall/ceiling/false ceiling/provided pole (mountingheight not more than 5 meter) etc with all accessories etc complete as perspecification no. CCTV-CAM. 334 Supplying & erecting of High definition 4/5 Megapixel IP IR Bullet Camerawith following featuresImage Sensor : minimum 1/2.8 Progressive Scan CMOS, Video Resolution : minimum 2592 x 1520Video Compression : H.264, H.265 or higher, at least Three individuallyconfigurable stream, Frame rate : minimum 25 fps at all resolutions, WDR : minimum 120 dB Wide Dynamic Range, ONVIF profile conformant, minimum IR distance : 50m, Lens Type : 2.8/4/6 mm Lens, fixed focal, Field of View :2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129°4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102°6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65°Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White,0.0 Lux (IR) Night Vision Distance minimum IR - 50m. Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°. Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant. Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone. minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain,white balance. Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D DigitalNoise Reduction, Automatic White Balance, Automatic Gain Control, BacklightCompensation, Highlight Compensation.Events : Privacy Masking, Motion detection, Scene change detection, Facecapture, Video tampering, audio exception detection, Region entrance detection,Region exiting detection. Operating temperature ( -30 to 60° C ) . Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X,digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed,FTP disabled. Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP,SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour,SNMP and Secure shell (SSH) supported protocol. RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalentBIS/TECH/STQC or any indian standards as applicable, CE, FCC certified.duly erected in position on wall/ceiling/false ceiling/provided pole (mountingheight not more than 5 meter) etc with all accessories etc complete as perspecification no. CCTV-CAM 335 Supplying, installing, testing & commissioning of 64/80 Ch Network VideoRecorder (NVR), suitable connect Min. 64 IP Cameras, up to 5 MegapixelResolution, with HDMI 1/VGA 1 and HDMI 2/VGA 2 outputs provided,Atleast one HDMI output of 4K resolution, atleast one VGA output with outputup to 1920 × 1080,Support H.265 or higher, H.264, MJPEG,Supports Redundant Dual Power,Incoming Bandwidth 320 Mbps with minimum 8 SATA Hard Disks, ANRTechnology,8 SATA interfaces for 8 HDDs and capacity of each HDD up to 8TB,minimum 02 USB port, Alarm I/O 16/4, RJ-45 10/100/ 1000 Mbps selfadaptiveEthernet interface,support multi brand network Cameras,ONVIF conformance,Multiple network monitoring: Web viewer .support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS,iSCSI, UPnP™, HTTPS.RoHS, UL, CE, FCC certified.duly erected in provided U Rack with wiring connections, tagging andprogramming etc. complete as per specificationss no. CCTV-NVR 336 Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Portof NVR, interface transfer rate 6 GB/S, maximum sustained transfer rate 210MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64,Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected inposition in provided NVR as per specification no. CCTV-HDD 337 Supplying & erecting 43 professional LED display with 1920*1080 (FullHD) Display, suitable for 16/32 channel NVR and following featuresBrightness: minimum 500 Cd/m2Contrast Ratio: minimum 1000:1Viewing angle: 178/178 deg.Response time: maximum 8 msInputs: HDMI, VGA, BNC,USB, Audio In, Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle dulyerected on wall or table top with standard accessories like wall mount stand andwiring connections etc. complete as per specifications no. CCTV-MON 338 Supplying and erecting HMS PVC conduitFRLS grade 20 mm dia. with PVC accessorieson wall / ceiling as per specification No: WG-MA/CON(1-2-3) 339 Supplying and erecting mains with 2x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW(1-3-5) 340 Supplying, installing, testing and commissioning of15 kWp ON-GRID Solar PV System / Plant consisting Solar PV Poly Crystalline Panel (335 Wp X 45 Nos.) and Solar ON-GRID Inverter of similar capacity (THD<3%) with interconnectingwires / cables up to solar ON GRIDinverter, proper base plate, canopy box to house Inverter and necessary accessories i.e. ACDB/ DCDB , MCB etc. wiring up to solar Inverter in casing and capping, display board, sign board, two distinct earthing, lightning arrester, liaisoning charges, remote monitoring system with maintaining card/chip for 5 yearsincluding net charges for RMS System, complete up to net meter installation and export to the grid with 5 year ON-SITE warranty and fully comprehensive maintenance contract as per Specification no. ESD-RT-ONG(4-5-4) 341 Supplying and erecting switch disconnector fuse (SDF) switch 415V up to 63A, open execution, four pole AC23 A rated with terminal shrouds on both sides and phase barriers along with telescopic shaft for depth adjustments and door interlock and padlock complying to IS/IEC 60947-3 Part-1/3HRC - DIN type fuse,insulation voltage 1000 Vfor enclosing in panel with rotary handle for ON / OFF operation (without HRC fuse)(5-1-17) 342 Supplying and erecting porcelain/epoxy bus bar support complete erected in provided M.S. box for 100A(5-10-26) 343 Supplying and erecting iron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority.(6-1-19) 344 Supplying and erecting static energy meter with 3 x 240V 50 Hz. AC supply 10 to 60 A, ISI mark,accuracy class 1.0 with backlit LCD display, (Measuring and display Trivector, V, I, kW, PF, Hz, Last month history of kWh andMD in kW) with special features like TOD, Tamper logging, Optical Communication Port & Display in absence of Power &with transparent hinge type box completeerectedonpolished teak woodboardduly wiredwithrequiredsizeof weather proofPVC wires duly testedby electric supply company.(6-3-3) 345 SupplyinganderectingAC three phase HT CT multifunctionnet meterDLMS compliance of accuracy class 0.5, 3x 63.5V, 50Hz,with backlitLCD display, optical port& RS 232 port( measures import kWh, kVAh, export kWh, kVAh, net kWh, kVAh, V, I, kW, 6 months history of energy, load survey, TOD, tamper detection & logging, power ON/OFF events, instantaneous parameters of rating 1/5A with display in absence of power)with wiring connections and mountinghardwareonprovidedpanelscompletewith calibration certificate from manufacturer. 346 Supplying, installtion & marking of surge arrestor/ surge protection device at the sub main distribution board after the incoming breaker of type 2 tested forImax 40 kAfor three phase and neutralwith compliance to IEC 61643-11 as per specification no. CP-SPD(6-6-6) 347 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 70sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL(7-1-33) 348 Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP(9-1-1) 349 Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results asper specification no. EA-EP(9-1-2) 350 Supplying and erecting aluminium strip of high purity required sizes used for earthing on wall and/or any other purpose with necessaryaluminiumclampsfixed on wall painted with bituminous paint with joints required as per specification no EA-EP.(9-2-1) 351 Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clampsfixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.(9-2-3) 352 Supplying and erecting conventionalspike typeair termination suitable to carry lightning stroke made up of heavy gauge40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipeerected on provided foundation complete.(9-3-1) 353 Making cement concretefoundationin 1:3:6 cement concrete,(20 to 25) mm. stone metal duly plastered with necessary curing forcomplete. (pole muffing or any other purpose).(16-3-7) 354 Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.(1-6-1) 355 Supplying and erecting modular type switch 16Aduly erected on provided plate and box with wiring connections complete.(1-6-2) 356 Supplying and erecting modular type 3 pin 6 / 16Amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete.(1-6-11) 357 Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected.(1-6-29) 358 Supplying and erecting bulk head LED fittingmax. 10Wwith high transitivity diffuser withsystem lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg.,THD<10%,p.f. >0.95, operating range of140-260V, in built surge protection of 2.5 kV, Life class of50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.(2-1-15) 359 Supplying, erectingandmarking DPMCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB(5-3-7) 360 Supplying, erectingandmarking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kAin provided distribution board as per specification no. SW-SWR/MCB(5-3-13) 361 Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.(5-4-13) 362 Supplying, fixing, and commissioning 2 pole, RCBO 6/10/16/20/25A,with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO(5-6-9) 363 Supplying, fixing, and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indicationas per specification no SW-RCCB/RCBO(5-6-13) 364 Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 4 sq mm copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU(7-2-9) 365 Supplying, erecting & terminating FRLS XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU(7-2-33) 366 Supplying, installing & testing maintenance free earthing comprising of Electrode of 17.2 mm diameterLow Carbon Steel with 250 micronmolecular copper bonded earthing rod ofLength 3malong with 25 kg Carbonbased environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI(9-1-5) 367 Supplying and erecting annealed bare copper wireof high purity of required sizesused forearthing onwall with necessarycopperclampsfixedon wall/cable/conduitwithscrews complete.(9-2-4) 368 SITC of Electric Traction Passenger Lift with · Rated capacity :- 8 Passenger/544Kg· Floors :- B+G+8 floor (10 Stops/10 Landings)· Travel :- 21 to 32 mtrs· Location of Lift Machine:- MR/MRL· Rated speed :- 1.5mps VS· Car/Landing door clear opening of 800 mm wide x 2000 mmhigh· Clear Car size of 1300 mm wide x 1100 mm deep x 2250mm high· Lift shaft available having clear size of .1900 mm wide x 1900 mmdeep, 1500 mm Pit depth, 4250 mm Overhead.· Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift carinterior design shall be done as per the directions of engineer in charge. (CSR Item no.17.1.13) 369 SITC of Electric Traction Passenger cum Stretcher/Hospital Liftwith · Rated capacity :- 15 Passenger/1020Kg· Floors :- B+G+8 floor (10 Stops/10 Landings)· Travel :- 21 to 32 mtrs· Location of Lift Machine:- MR/MRL [applicable for PassengerLift with MRL only & Stretcher/Hospital Lift with MR & MRL]· Rated speed :- 1.5mps VS· Car/Landing door clear opening of 800/900/1000 mm wide x2000mm high· Clear Car size of 1000 mm wide x 2400 mm deep x 2250mm high· Lift shaft available having clear size of 1800 mm wide x 3000 mmdeep,1500 mm Pit depth, 4250 mm Overhead· Doors type :- COPO/TOPO Doors with frame made from SS 304 gradesolid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landingdoors with SS door architraves/frames The lift doors shall have minimum 1hour fire rating (with submission of necessary valid test certificate issuedby NABL accredited or Independent test laboratory).· Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of1.5mm, thick with hairline finish with frame made from MS girders, bracing ofadequate size with minimum safety factor of 5, with Toe Guard Apron, withnecessary false ceiling with adequate LED lights, blower/fan for ventilation & SSchequered plate flooring, handrails, mirror, emergency light etc. The lift carinterior design shall be done as per the directions of engineer in charge. (CSR Item no.17.1.17) 370 For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOPs with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travellingcables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. 371 For Lift having 1000mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOPs with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travellingcables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete. 372 Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC(1-1-9) 373 Supplying and erecting mains with 2x2.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(1-3-2) 374 Supplying and erecting green colour earthing with 1x 2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(1-3-2) 375 Supplying, installing, testing & commissioning split type variable speed invertertechnology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0TR to 1.2TRcapacity having ISEER minimum 5.00suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC 376 Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete. 377 Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigeranthaving 22SWG thickness and inner dia/size 16mm complete. 378 Supplying, erecting, testing and commissioning of 10HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. 379 Supplying, erecting, testing and commissioning of 12HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000m operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. 380 Supplying, erecting, testing and commissioning of 14HP, VRF/VRV air conditioning system outdoor unit (ODU) complies type-IV OEM standards working on HFC refrigerant R410A or other required/suitable green equivalent refrigerant, for minimum cooling capacity as delivering 100% capacity at 47° C, non stop cooling even at 56° C and coefficient of performance (COP) 3.00 to 4.00, modular type vertical hot air discharge suitable for longer piping range upto 1000 metre operation in cooling mode with inverter/digital VRF/VRV technology microprocessor based control compressor starter/control panel with scroll compressor, air cooled copper condenser coil of suitable shape for increasing maximum heat transfer area, rain protection cover, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V±10%, 50 Hz, 3 phase power supply (all suitable for high ambient conditions), internal copper refrigerant piping, internal wiring and refrigerant, etc. all housed in powder coated weather proof cabinet complete. 381 Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 0.6TR - 0.8TR ( 229 to 358 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anti-corrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete. 382 Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 1.3TR (421 cfm) to 1.7TR (586 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anticorrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete. 383 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact/standard size) of nominal cooling capacity 2.0TR (618 cfm) to 2.3TR (671 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. 384 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 2.6TR (918 cfm) to 2.8TR ( 1100 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. 385 Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette room/indoor unit (IDU-compact / standard size) of nominal cooling capacity 3.0TR (1100 cfm) to 3.2TR (1165 cfm) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. IDU with drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anti corrosive coating suitable for coastal area in all respects suitable to operate on 1-phase, 230V, 50Hz, AC supply complete. The unit consisting with any additional refrigerant and oil charge as per requirement during installation. 386 Supplying and erecting circular flexible/rigid PVC pipe duct of size 100mm dia, 4mm thickness with required couplers, reducers, T-joints, Y-joints elbows and necessary supports etc. with sealing with provided control/air flow regulating valves / dampers, filters at position complete. 387 Supplying and erecting circular flexible/rigid PVC pipe duct of size 150mm dia, 4mm thickness with required couplers, reducers, T-joints, Y-joints elbows and necessary supports etc. with sealing with provided control/air flow regulating valves/dampers, filters at position complete. 388 Supplying, erecting, testing and commissioning centralised programmable remote control panel (HMI) touch manager controls minimum 16 system of 64 ODUs can be controlled and up to 992 IDUs can be individually mounted and controlled indoor units having colour min 200mm size LCD touch panel, yearly schedule, power proportional distribution function, temperature limitation, history function complete erected on wall integrated with provided fire alarm system. 389 Supplying and installation of high pressure grade required size copper connection Y or T- Joints/refnet complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV/VRF air conditioning system. 390 supplying, laying/fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 28.6mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations with OEM standards of VRV/VRF air conditioning system complete. 391 supplying, laying/fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 22.2mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiation with OEM standards of VRV/VRF air conditioning system complete. 392 supplying, laying/fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 19.1mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. 393 Supplying, laying / fixing, testing and commissioning of ofappropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.(3-11-94) 394 Supplying, laying / fixing, testing and commissioning of ofappropriate nominal refrigerant copper pipe of 12.7mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.(3-11-95) 395 Supplying, laying / fixing, testing and commissioning of ofappropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.(3-11-96) 396 supplying, laying/fixing, testing and commissioning ofappropriate nominal refrigerant copper pipe of 6.4mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete. 397 Supplying, erecting, testing & commissioning fresh air intake system, ductable circular inline/cabint exhaust air fan inlet unit having 5000 cfm capacity with maintaining the static pressure minimum 65mm suitable to operate on 1 phase, 230V, 50Hz, A.C. supply complete.With fabrication and iron work. 398 Supplying, erecting, testing & commissioning fresh air intake system, ductable circular inline/cabint exhaust air fan inlet unit having 3000 cfm capacity with maintaining the static pressure minimum 65mm suitable to operate on 1 phase, 230V, 50Hz, A.C. supply complete.With fabrication and iron work. 399 Supplying, erecting, testing & commissioning fresh air intake system, ductable circular inline/cabint exhaust air fan inlet unit having 2500 cfm capacity with maintaining the static pressure minimum 65mm suitable to operate on 1 phase, 230V, 50Hz, A.C. supply complete.With fabrication and iron work. 400 Supplying, erecting, testing & commissioning fresh air intake system, ductable circular inline/cabint exhaust air fan inlet unit having 1000 cfm capacity with maintaining the static pressure minimum 65mm suitable to operate on 1 phase, 230V, 50Hz, A.C. supply complete.With fabrication and iron work. 401 Supplying & erecting tile type modular diffuser made from aluminium sheet with powder coated matching to the ceiling shade for provided supply and return air complete. 402 Supplying and erectingelastomeric nitrile rubber / foam tube type sleeves forcoating and insulating on provided PVC / copper pipes having 9 mm thickness and inner diameter / sizes 28 mm for solar water heater/AC system. 403 Supplying and erecting 25/32 mm (ID/OD) Chlorinated polyvinyl chloride pipe (CPVC), thickness 3.2 mm conforming to IS 15778 (CTS Series)with necessary CPVC fittings and solvent cement for Solar Water Heater System as per specification No. ESD-HWP/CPVC 404 Supplying and erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.(5-4-13) 405 Supplying, fixing, and commissioning 2 pole, RCBO 6/10/16/20/25A,with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO(5-6-9) 406 Supplying, fixing and commissioning 4 pole RCBO 32/40A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection,with 30/100/300 mA sensitivity and short circuit and earth leakage trip indicationas per specification no SW-RCCB/RCBO 407 Supplying and erecting GI sheet 0.6 mm (24 SWG) having zinc coating of 120 microns withgalvanization process compliance to IS 2629:1985 tobeused for fabricationofboxespanelboardsetc. including cutting, bending, drilling, welding, riveting etc. and paintingwithone coat of red leadpaint and 2 coats of enamel paint.(6-1-2) 408 Supplying and erecting GI sheet 0.8 mm (22 SWG) having zinc coating of 120 microns withgalvanization process compliance to IS 2629:1985 tobeused for fabricationofboxespanelboardsetc. including cutting, bending, drilling, welding, riveting etc. and paintingwithone coat of red leadpaint and 2 coats of enamel paint.(6-1-3) 409 Supplying and erectingGI sheet 1.25 mm (18 SWG)having zinc coating of 350 microns withgalvanization process compliance to IS 2629:1985 tobeused for fabricationofboxespanelboardsetc. including cutting, bending, drilling, welding, riveting etc. and paintingwithone coat of red leadpaint and 2 coats of enamel paint. 410 Supplying and erecting iron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority.(6-1-19) 411 Supplying, erecting& terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core6 sq. mm. copperconductor completeerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU 412 Supplying, erecting& terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core10 sq. mm. copperconductorcompleteerected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipeas per specification no. CB-LT/CU

Key Dates

Publish Date 30-06-2025
Last Date of Bid Submission 07-07-2025
Tender Opening Date 10-07-2025

Contact Information

Company Name Municipal Corporation Aurangabad
Contact Person EXECUTIVE ENGINEER
Address TOWN HALL, CHHATRAPATI SAMBHAJINAGAR

Other Detail

Information Source https://mahatenders.gov.in
Download FileName File Description File Size
Download cb34f49e-0f33-4095-b888-fa3b413315ca.html Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Download TENDERDOCUMENTKANCHANWADI.pdf Tender Documents 0 KB
Download BOQ_2071853.xls Tender Documents 0 KB
Download DRAWINGKACHANWADI.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.