Tender For Provn Of Deficient Md Accommodation For Airmen Of Afs Khaneri Hills (Ph-I); 1 NOTE: Schedule ‘A’ Part I to XIV under Ser No. 1.00to 14.00 are prepriced by MES. Bidders shall insert their lumpsum amount in the green coloured field under Col-6 only. 2 Lump sum price worked outfor BUILDINGS/ STRUCTURES as listed in Sch A Part I. 3 Lump sum price worked out for EXCAVATION, EARTH WORK AND SITE CLEARANCE as listed in Sch A Part II 4 Lump sum price worked out for INTERNAL ELECTRIFICATION as listed in Sch A Part III 5 Lump sum price worked out for INTERNAL WATER SUPPLY as listed in Sch A Part IV 6 Lump sum price worked out for SEWAGE DISPOSAL as listed in Sch A Part V 7 Lump sum price worked out for AREA DRAINAGE as listed in Sch A Part VI 8 Lump sum price worked out for ROAD/ PATH as listed in Sch A Part VII 9 Lump sum price worked out for RETURNING WALL as listed in Sch A Part VIII 10 Lump sum price worked out for EXTERNAL ELECTRIFICATION as listed in Sch A Part IX 11 Lump sum price worked out for EXTERNAL WATER SUPPLY as listed in Sch A Part X 12 Lump sum price worked out forLIFT as listed in Sch A Part XI 13 Lump sum price worked out for FIRE FIGHTING SYSTEM as listed in Sch A Part XII 14 Lump sum price worked out for HOT WATER SUPPLYas listed in Sch A Part XIII 15 Lump sum price worked out for LIGHTENING PROTECTION as listed in Sch A Part XIV 16 SCHEDULE A PART - XV MISCELLANEOUS ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 5 signifies this fact only. Bidder shall insert their rates in Green filed under Col-6. 17 SITE CLERANCE & DEVELOPMENT 18 M &L for Surface excavation n.exc30 cm deep and averaging 15cm deep and getting out top layer arqanie soil without disturbing or destroy its texture and remove the same to a location specified and stored properly for relaying after the completion of building work exc 1.50 Km but n exc 5 Km complete all as specified and as directed 19 Relaying the soil excavated in Item no 15 to building site for landscaping and gardening complete all as specified and directed 20 S&F Step-on pedal garbage dust bin plastic body for indoor use in color of 50 litre capacity Red/Blue/Green.Note :-Labelling on dustbin are as follows:a) Green color waste bin :- Bio degradable wasteb) Blue color waste bin :- Reusable/ Recycle waste c)Red color waste bin :- Land Fill waste 21 INTERNAL ELECTRIFICATION 22 S & F Ventilator DSP Metal Domestic Exhaust fan 230mm sweep complete all as specified and directed. Make : Havells Cat part No FHVVEMTDB509 or equivalent in Philips/Orient/Crompton 23 S & F LED light 10 Watt complete all as specified and directed. 24 S & F Bulkenlight 9 Watt complete all as specified and directed. 25 Supply, installation, testing and comminsioning of perforated GI sheet cable tray of size 900mm x 62.5mm x 2.0 mm with necessary angle iron suspension supports, anchor fasteners etc complete max height of suspension shall not exceed 500mm size of tray shall be suitable for laying the above mentioned cablescomplete all as specified and directed. 26 Supply and fix MCBdistribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof DB, SPN 6 way , 240 Volts, earth bar IP 43 protection, flush to wall complete all as specified and directed. 27 Supply and fix MCBdistribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof DB, Vertical Triple pole and netural 8 way , 240 Volts, earth bar IP 43 protection, flush to wall complete all as specified and directed. 28 Supply and Installation of Smart Single Phase Meter of different makes (Not more than 33 % of a particular make) including polycarbonate boxes with transparent cover to view meter display with the following specifications:(a) AC Single Phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 5A-60A, with 3200 impulses per KWh,LED forPhase presence & LED for Relay status, conforming to IS-16444 standard with inbuilt 865-867 MHz 6 Low PAN Mesh Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LCD based display only with compatible IP54 compliant polycarbonate box for outdoor mounting with optical port Provision on meter box. Meter Should support the following data : 15/30 min instantaneous data for Voltage, Current, Power factor, Power, Cumulative energy and frequency, monthly billing data & antitamper features. Load survey data for 45 days with 30 min integration period for kWh, Voltage, Current, frequency etc.Meter should have connect / disconnect functionality operable from prepaid billing software & shall show balance on displayThe meter should support open communication protocol DLMSwith the softwareNote :-(a) It should run the meter in both prepaid and postpaid mode(b) The meters should carry 5 year warranty.(c) OEM shall have own NABL accredited lab for testing meters as per IS 16444 and certification shall be provided during sample approval(d) The meter cost would include DCU/ Gateway and repeater cost for RF commuication meters 29 Supply and Installation of Smart Three Phase Meter of different makes (Not more than 33 % of a particular make) including polycarbonate boxes with transparent cover to view meter display with the following specifications:AC Three Phase Four Wire, Tamper Proof, Static Meter of Class 1.0, 3x240 V, 50 Hz, 10A-60A, with 1600 impulses per KWh & KVArh,LED for Relay status, conforming to IS-16444 standard with inbuilt Cellular or inbuilt 865-867 MHz 6LowPAN Mesh Radio Frequency communication facility with self healing Mesh network with default and on demand display, billing data generation facility, anti-tamper features, Microprocessor and LCD based display only with compatible IP54 compliant polycarbonate box for outdoor mounting with optical port Provision on meter boxMeter Should support the following data : 15/30 min instantaneous data for Voltage, Current, Power factor, Power, Cumulative energy and frequency, monthly billing data & antitamper features. Load survey data for 45 days with 30 min integration period for kWh, Voltage, Current, frequency etc.Meter should have connect / disconnect functionality operable from prepaid billing software & shall show balance on displayThe meter should support open communication protocol DLMSwith the softwareNote :-(a) It should run the meter in both prepaid and postpaid mode(b) The meters should carry 5 year warranty.(c) OEM shall have own NABL accredited lab for testing meters as per IS 16444 and certification shall be provided during sample approval(d) The meter cost would include DCU/ Gateway and repeater cost for RF commuication meters 30 Supply, installation, commissioning and testing indoor type LT wall mounting Bldg panel board of suitable sizefactory made TTA panel, weather, dust & vermin proof indoor, double door, front openable, locking arrangements made out of 2.00 mm thick mild steel CRCA sheet including required comparment for fixing of four (04) Nos single phase smartmeter, MCCB and MCB and porviding glass view for reading of meter and providing rubber/ PVC gasket of suitable size all sides of door, with copper busbar wrapped with PVC tape/ sleeves with maintained the colour code and copper strip/ wire busbar of suitable size to MCCB input and MCCB/ MCB output of suitable length for connection of cable from main busbar, angle iron 50 mm x 50 mm x 5 mm thick supporting frame including applying two coats of powder coated paint over a coat of red oxide zinc chrome primer over exposed external & internal surfacesfor 3 phase 4 wire system 415/ 440 volts grade including internal wiring connections for all outgoing / incomming cable,earthing teminals , danger plate, suitable PCC platform complete all as directed by Engineer-in-Charge. 31 INCOMING : (a) Copper strip busbar of size 30 x 5 mm wrapped with PVC sleeves with maintained the colour code and provision of making holes with Copper nuts, bolts & washers for cable connections including hydrograpic insulators with nuts & bolts at both ends= 04 Nos.(b)MCCBIP 44 and IP 66/67 protection, 4 pole, 415 volts, Lcu=35 KA breaking capacity, rating 250 Amps, adjustable thermal magnetic release including all fixing accessories with both ends spreader links -01 No.(c) Digital voltmeter of range (0-500) volts, flush mounting type of size 100mm x 100mm (4”x4”) square dial with selector switch – 01 No(d)LED Neon indicator lamp (RYB) with holder,230/250 volts,AC -01 set (set of three) Make :- AE/L&TOUTGOING : (a) MCB, Single pole & neutral, 32 amps, 415 volts, ‘C’ curve, 16 KA allcomplete as specified and as directed - 44 Nos (b) Slot for fixing the Single/three phase smart prepaid meter - 45 Nos (Cost of Smart meter cost will be paid seperately under respective itemly) 32 INTERNAL WATER SUPPLY 33 S & F two way bib cock with wall flange quarter turn (flow rate 6Liter per minute) 15 mm dia. complete all as specified and directed Make : Hindware Cat part No F280054GRCP or equivalent in Cera/Jaquar /Kohler 34 S & F Overhead Shower (flow rate 6Liter per minute) Single function Square overhead shower 150x150 mm Flow with Air Effect (ABS Body & Face Plate Chrome Plated) with Rubit Cleaning System 16 mm dia. complete all as specified and directed Make -Cera Cat Part No F7020103AB, or equivalent in Hindware/Jaquar /Kohler 35 S & F Wall Mixer 3 In 1 (flow rate 6 liter per minute) with flange Provision For Overhead Shower with 115mm Long Bend Pipe On Upper Side, Connecting Legs & Wall Flangescomplete all as specified and directed.Make - Cera Cat Part No f2013401,Hindware Cat part No F280016GRCP or equivalent in Jaquar /Kohler 36 S & F Gun-metal, globe or gate valves, of 65 mm Dia bore of pipe with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed 37 S & F of corner glass shelf 12 inch x 12 inch of 8mm thick glass fixed with stainless steel screws on wall complete all as specified and directed. 38 ROAD/ PATH 39 M & L for bituminous macadam50 mm thickness consolidated/ compacted thickness using hot mix plant and mechanical paver with 4% binder (paving bitumen VG-30 grade) content by weight of total mix and 8% of waste plastic by weight of bitumen, rolled and compacted using 8 to 10 tonnes power roller to required camber and gradient complete all as specified and as directed. Note :-(a) The waste plastic should not be PVC sheets or flux sheets, the shredded plastic of size 2-3 mm particle size.(b) Design mix should prepared as per IRC:SP:98-2013. 40 M&L for providing 30mm thick (consolidated thickness) Semi Dense Asphaltic Concrete (SDAC) with 5.50% paving bitumen (VG-30) binder content by weigh to total mix and 8% of waste plastic by weight of bitumen with mechanical paver using, mixed in hot mix plant, rolled and compacted and well rolled and consolidated with 8 to 12 tonne power roller to reqd gradient and camber complete all as specified and directed. Note :- (a) The waste plastic should not be PVC sheets or flux sheets, the shredded plastic of size 2-3 mm particle size.(b) Design mix should prepared as per IRC:SP:98-2013 guideline 41 S&F Cobble Stone100mm x 100mm x 40mm thickwith grey cement and pigment, set, jointed and pointed in neat cement slurry in floors over 25mm thick screed bed or bedding layer of cement mortar 1:6 complete all as specified and directed. 42 Material and labour for providing and painting 2.5 mm thick road marking strip (retro reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser,propane tank heater and profile shoe heater, driven by experienced operator on road surace including all cost of material, labour, T&P, cleaning of road surface of dirt, seals, ils, grease and foreign material etc. complete all as specified and directed. 43 Supply and fix ABS dual directional UV protection reflective panels/ road studs/ cat eyes made of plastic body of size 90x110x17mm fixed to the surface with epoxy adhesive as per manufacturers instruction of specified make or equivalent, Amber, Red or white in colour completeall as specified and directed.Make - 3M 290 series or equivalent as approved by GE. 44 Supply and fix high intensity prismatic dual directional powder coateddelineator having 100mm dia HIP sheet reflector (red/yellow/white) held in strong ABS body mounted over CRC steel tube 47mm dia of 16 gauge sheet support of total height 600mm having flared/welded foot for firm grip to base, HIP reflector and ABS body shall be protected in a welded mesh cage, all steel parts shall be stove enamelled and powder coated and delineator need to be fixed to ground in 200 x 200 x 200 mm concrete block below ground complete all as specified and directed. 45 EXTERNAL ELECTRIFICATION 46 Supply ,Installation, testing and commissioningof copper wounded transformer step up/ step down, outdoor type capacity 250 KVA , 22 KV,3 phase , ISS: 1180(2014) Part-I & Latest , E.E. Level -II , Amendment No 4 , 50 C/S oil immersed , Natuarally cooled ,out door type step down Transformer having a No load Voltage Ratio 22000/433V , Vector group Dyn 11 with plus minus 2.5 plus minus 5% off Circuit Tapping as under taken out on the HT side and connected to 22 KV off circuit Tapping switch , HT winding connected in Delta & LT winding connected in Star and the Neutral brought out & connected to a Separate terminal for earthing with outdoor open porcelain bushing on HV side & cable box on LV side with the temperature rise not excceding 40 degree centrigrade by thermometer in oil and 45 degree centrigrade by resistance & Ambient temp 40 degree centrigrade with first filling of Oil with following (i) fitting and accessories:- (a) First fill of Transformer oil (b) 22 KV off circuit tapping switch (c) Oil conservator tank with drain plug and filling cap.(d) Silica gel dehydrating breather charged with silica gel. (e) Oil level gauge.(f) Oil filter valve.(g) Oil drain valve .(h) Thermometer pocket with thermometer (OTI) .(j) Diagram and rating plate.(k) Two earthing arrangements. (l) lifting lugs. (m) four Bidirectional plain roller.(n)Air vent plug(o) Explosion vent. (p) Barebushing on HV side. (q) Cable box on LV side(r) cooling radiators.(s) C .I rollers. (t) Additional neutral terminal brought out side the LV cable box earthing(ii) Extra fittings :-(a) Oil temp Indicator (OTI) (b) Inspection cover.(iii)Inspection :-Transformer factory inspection carried out by department .and test certificate will be furnished for all routine testincluding oil test. 47 Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) earthed ,with stranded aluminium conductor, 22000 volts grade, of size 3 core 95 sq mm complete all as specified and as directed. 48 Supply, Installation, commissioning in of LT panel board(Outdoor type ) TTA (Total type Assambly) PANELnot less than made out of 3.15 mm thick CRCA sheet vermin proof, including painting with sysnthetic enamelled paint, with colour code PVC sleeves for bus bar, front opened with locking arrangement, closed bus bar chameber, angle iron frame of size 50x50x6mm for skeleton and support embeded in concrete foundation comprising of the following :- (Main Incoming Panel)Incoming :- (a) Aluminium bus bar 400 amps for phase & neutral-01 No (b)Microprocessor based Moulded Case Circuit Breaker 320 Amps, 25 KA(Adjustable Type- 01 Nos (In coming) (c) Microprocessor based Moulded Case circuit breaker 250 Amps, 25 KA - 01 Nos (O/G) (d) Microprocessor based Moulded Case circuit breaker 63 Amps, 25 KA - 02 Nos (O/G) (01 Nos for use & 01 Nos for spare ), (e) MCB SPN 32 AMPS 02 NOS (O/G) (f) Voltmeter 0-500 volts range with selector switch digital type - 01 Set(g) Ammeter 0-100 amps range with selector switch & CT coils - 01 Set (h)Indicator lamp with holder for RYB- 01 Set. 49 Supply,installation, commissioning in of LT panel (Outdoor type ) board not less than made out of 3.15 mm thick CRCA sheet vermin proof, including painting with sysnthetic enamelled paint, TTA type approved with colour code PVC sleeves for bus bar, front opened with locking arrangement, closed bus bar chameber, angle iron frame of size 50x50x6mm for skeleton and support embeded in concrete foundation comprising of the following :- (Existing DG SET 100 KVA ) Incoming :- (a) Aluminium bus bar 250 amps for phase & neutral-01 No (b)MCCB 160 4Amps,- 01 Nos (In coming)(d) Microprocessor based Moulded Case circuit breaker 4 P 100 Amps, 25 KA Adjustable type- 02 Nos (O/G), (e) MCCB 4 P 63AMPS 25 KA -01 NOS (O/G) (f) MCB SPN 32 AMPS -02 NOS (O/G) (G) Voltmeter 0-500 volts range with selector switch digital type - 01 Set(g) Ammeter 0-100 amps range with selector switch & CT coils - 01 Set (h)Indicator lamp with holder for RYB- 01 Set. 50 Supply,installation, commissioning in of LT panel (Outdoor type ) board not less than made out of 3.15 mm thick CRCA sheet vermin proof, including painting with sysnthetic enamelled paint, TTA TYPE with colour code PVC sleeves for bus bar, front opened with locking arrangement, closed bus bar chameber, angle iron frame of size 50x50x6mm for skeleton and support embeded in concrete foundation comprising of the following :- ( for lift and lighting ) Incoming :- (a) Aluminium bus bar 100 amps for phase & neutral-01 No (b)Microprocessor based Moulded Case Circuit Breaker 63 Amps, 16 KA(Adjustable Type- 01 Nos (In coming) (c) Microprocessor based Moulded Case circuit breaker 40 Amps, 10 KA - 04 Nos (O/G) , (d) MCB SPN 32 AMPS 02 NOS (O/G) (e) Voltmeter 0-500 volts range with selector switch digital type - 01 Set(f) Ammeter 0-100 amps range with selector switch & CT coils - 01 Set (g)Indicator lamp with holder for RYB- 01 Set.(h) contactor 3 pole 32 amps -01 Nos (k) Infra red sensor based digital timer switch 16 amps single phase 01 Nos . 51 Supply install commissioning and testing of AutomaticInteligent power factor correction (APFC) Panel for 3 phase 415 volts 50 Hz supply system of capacity60KVAR to improve the power factor from 0.8 to 0.99 / unity automatically with step wise switching facility with floor mountedoutdoor typeweather proof dust / vermin proof CPRI approved powder coated cubicle panel made out of 3.15 mm CRCA sheet and angle iron 40x40x6mm frame factory made fabricated as modular in duly powder coated front openable with locking arrangement of capacity 60 KVAR with suitable cpapacity capacitor(Nearest correction 1 KVAR)with the following accessories Note - Make of capacitor shall be Epcos/ Schneider/ Siemens complete all as specified and as directed. (a) copper bus barsuiatble size of main in commer (b) Incommer MCCB 100 Amps 4 pole 25 KA (c) selector switch auto manual operation (d) Push button for switching ON/ OFF for capacitors (e) ON/OFF status indicators for each capacitors(f) colour coded RYB supply indicator -03 Nos (g) digital Ammeter with selector switch -01 Nos (h) digital volt meter with selector switch -01 Nos (j)APFC controler including all accessories such as CT/PT , timer , add on block , selector switch with time delay fuction for spacing the auto switching ON/ OFF facilities incase of leading / lagging PF auto manual selector switch one set . (k) Panel wiring of 2.5 sqmm one lob Make - MCCB & MCB shall be ABB / Indoasian / Havells 52 Supply and fix cable jointing kit for 22 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Al conductor cable of size95 sq mm complete all as specified and directed. 53 Supply, Installation, testing and commissioning of Ring main unit 22 KV , out door ,630 Amps A , SF 6 , having two incoming isolator and three outgoing breakers rated volatge 22 KV insulation level 50 KV rated current 630 amps having rated short time current 21 KA for 3 second , short circuit breakering current 21 KAearth switch short time withstand current 21 KA , ambient temerature min 25 degree centrigrade , degree of protection IP 67 , SF6 Gas filling pressure at 20 degree centrigrade. Load breaker switch with following components : 630 amps , triple pole ., single Break , 3 position ( ON/OFF,EARTH) Ring Main switches each with independent manual mechanism and fully rated earth switch qty -02 air insulated cable boxes with gland plate suitable for bottom entry of single run of 3 core cable qty 02 upto 300 sqmm qty 02 , Set (03 Nos ) of cable bushing qty 02 . live line indication LED display qty 02 , mimic diagram on front panel complete with status indicators ( ON / OFF, EARTH) qty -02 , fault passage indicator with remote contact -02 , set of right boots NOn touch Proof -02 .VACCUN CIRCUIT BREAKER (VCB) WITH FOLLOWING COMPONENTS . 630 AMPS 21 KA Triple pole Vaccum Circuit breaker with independent manual mechanism and fully rated earth switch with provision for earth cable for earthing Each- 03 , Air insulated cable box with gland plate suiatble for bottom entry of single run of three core suiatble upto 300sqmm Each-03 . over current& earth with digital displays & auxiliary power supply each -03 , set of current transformers for protection circuit mounted on cable bushing ,CT ratio 50/1Amps , 2.5 VA, 10P10 protection Each set of 3 , live line LED indicatorsLED display Each -03 Mimic diagram on front panel complete with status indicators( ON/OFF,EARTH) Each -03 , epoxy mounted low eneegy tripping coil for tripping the circuit breaker in fault condition Each 03 , Local Push to Trip mechanism for emergency trip Each -03 set of potential free contacts for SCADA compatibility Each -03 complete all as specified and directed. 54 M&L for platform for transformer of size 3000mm x 2000mm x 1200mm with brick masonry construction in cement mortar 1:4, PCC (1:4:8) type D-2, 150mm thick as in foundation, PCC (1:2:4) type B-1, 40mm thick as in floor over sub base PCC (1:4:8) type D-2, 75mm thick, brick masonry step on one side to made access to the top of platform including excavation & earth work in any type of soil including15mm plastering to brick masonry in CM 1:4 andapplyingtwo coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and two coats of white wash on plastered surface complete all as specified and directed. 55 Supply onlyRubber mat of 2 meter x 1 meter x 19 mm thick 22KVgrade ISI Markedper approved make complete all as per specified and as directed 56 Supply only Rubber mat of 2 meter x 1 meter x 10 mm thick 11KVgrade ISI Markedper approved make complete all as per specified and as directed 57 Material and Labour for Road cuttingfor crossing cablein any kind ofsoil/rock strata complete all as per specified and as directed 58 Material and Labour for Junction box with fuse provision and suitable connection for three phase incomming cable 3 phase out going cable and single phase connection for light fitting with controlled MCB SP-6 Amps -01 Nos enclosed in thermo plastic in closed shock proof safe complete all as per specified and as directed 59 S & F Copper conductor cable 3 core of size 1.5 Sqmm complete all as per specified and as directed 60 EXTERNAL WATER SUPPLY 61 Supplying, installation, commissioning and testing of centrifugal pump set BEE 5 Star rating, electic motor driven, not less than 7.43 LPS at 65 metre head in load, suitable for pumping raw water, complete all as specified and directed and comprising of the following specifications:-(i) Pump, centrifugal, horizontal, split type not less then 7.43 LPS discharge, at 65 metre head, 1440 RPM having bronze impeller and stainless steel shaft single stage directly coupled with electric motor through flexible copling (ii) Squirrel cage indication motor, TEFC, 3 phase 415 + 10 volts, 50 C/S AC supply 1440 RPM, not less then 10HP directly coupled to centrifugal pump(iii) Common base foundation of ISMC - 100 suitable for installation of above pump set duly drilled holes and painted with two coats of synthetic enamel paint over a coat of red oxide primer(iv) Above ISMC foundation shall be grouted in PCC 1:3:6 type C-2 using 40mm graded aggregate, 30 cm above GL and 15 cm below GL and as per size of common base foundation/ standard Engg practice or as directed by Engineer-in-Charge.(v) Boudrons type pressure gauge 3 dia dial typeMake :- Kirloskar Brothers Ltd / Beacon / KSB / JyotiNote:- Sluice valve and reflux valve, DI pipe and fittings etc. required for suction and delivery and common header etc. shall be measured and paid separately in respective items. 62 Supply and fix gun-metal, globe or gate valves (ISI marked) conforming to IS 9338, 80 mm dia bore with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 63 Material and labour for construction of brick masonry valve pit of internal size 90cm x 90cm x 90cm suitable for gate valves/ sluice valve upto 150 mm including necessary excavation and earth work, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 50mmx50mmx6mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock complete all as specified and directed.Note:- (i) Brick wall shall be 23 cm thick built in cement mortar (1:6)(ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450 mm from top shall be 20 mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds(iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls (iv) PCC coping shall be 15 cm thick in cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC(v) Three coats of white wash to internal surfaces of valve pit shall be provided(vi) Depth of valve pit shall be reckoned from the top of PCC in foundation 64 Material and labour for construction of brick masonry valve pit of internal size 45cm x 45cm x 45cm suitable for gate valves/ sluice valve upto 150 mm including necessary excavation and earth work, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock complete all as specified and directed.Note:- (i) Brick wall shall be 23 cm thick built in cement mortar (1:6)(ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450 mm from top shall be 20 mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds(iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls (iv) PCC coping shall be 15 cm thick in cement concrete (1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC(v) Three coats of white wash to internal surfaces of valve pit shall be provided(vi) Depth of valve pit shall be reckoned from the top of PCC in foundation 65 Supply,installation, commissioning in of LT panel (IN door type ) board not less than 100x100x65 cm made out of 2 mm thick CRCA sheet vermin proof, including painting with sysnthetic enamelled paint, CPRI approved with colour code PVC sleeves for bus bar, front opened with locking arrangement, closed bus bar chameber, angle iron frame of size 50x50x6mm for skeleton and support embeded in concrete foundation comprising of the following :- (Main Incoming Panel)Incoming :- (a) copperbus bar 200 amps for phase & neutral-01 No (b)Microprocessor based Moulded Case Circuit Breaker 63 Amps, 35KA (c)Adjustable Type- 01 Nos (In coming)(O/G) (d) MCCB 4 P 40 AMPS 25 KA -02 NOS(e) MCB SPN 32 Amps -02 Nos(f) Voltmeter 0-500 volts range with selector switch digital type - 01 Set(g) Ammeter 0-100 amps range with selector switch & CT coils - 01 Set (h)Indicator lamp with holder for RYB- 01 Set.(j) Contactor 3 pole 18 Amps-02 No.(j) fully automatic star delta Starter typeFASD having relay of range 09-14 Ampcentrifugalpump set -02 Nos (k) Over load Relay (8-12 Amps -02 Nos (l) Single phase preventor for motor -02 Nos (m) digital timer switch 16 Amp single phase- 01 No. 66 S&F Copper conductor cable 3 core of size 6 Sqmm complete all as specified and directed.Make: Havells/Polycab/Finolex 67 S&F Cast Iron foot valve for 80 mm bore pipe, lift flanged type as per IS-4038 complete all as specified and directed 68 LIFT 69 Suppy, installation, testing, commissioning, putting into operation and final testing of automatic lift of 8 passengers capacity (544 kg) complete in the shaft well and pit constructed including automatic rescue device (ARD), all standard equipments, accessories and control equipments as per manufacturer design, conforming to NBC/ local by laws and fulfilling the following requirements complete all as specified and directed: 70 (i) Type: Passenger lift(ii) Load: As specified elsewhere from 2 passenger to 13 Passenger for 13 Passenger lift and 2 passenger to 8 passenger for 8 passenger lift (For each person standard weight of 68 Kg)(iii) Speed: 1.00 to 1.5 metre/sec(iv) Control: ACV3F, 32 bit microprocessor integrated serial communication control system with RMS (Remote Monitoring System)/ BMS (Building Monitoring System) supporting software(v) Motor/ Machine: Permanent magnetic synchronous gearless motor(vi) Operation: Simplex collective selective with/without lift attendant(vii) Total rise: Near about 48 Mtrs (Approx) 13 stops only(viii) Landing: All floors on the same side(ix) Floor Served:G+11(x) Signals: Digital car position indicator, car travel direction indicator inside car and at all landings, voice annuciator with suitable music shall be provide in the lift car(xi) Shaft size: As per manufacturers design specification, shaft to be constructed separately(xii) Guide rail :As per manufacturers specification(xiii) Lift and car size: As per manufacturers specification(xiv) Car entrance: As per manufacturers specification(xv) Car door: S.S(Stainless steel) Hairline finish centre/ Telescopic opening door with vision panel(xvi) Landing door: S.S(Stainless steel) Hairline finish centre/ Telescopic opening door with vision panel(xvii) Door Operation: Automatic electric power operated door, full height infra red curtain with multiple criss/ cross light beams(xviii) Car interior: S.S (Stainless steel) panel with hair line finish on all sides.(xix) Car floor: Anti skid PVC flooring on heavy duty MS (Mild steel) platform(xx) Car ceiling and lighting: S.S (Stainless steel) finish with aesthetic appearance with LED ceiling lights 71 (xix) Car floor: Anti skid PVC flooring on heavy duty MS (Mild steel) platform(xx) Car ceiling and lighting: S.S (Stainless steel) finish with aesthetic appearance with LED ceiling lights(xxi) Car Ventilation: Pressure fan/ blower fan (Car fan with automatic sleep timer shall be provided)(xxii) Emergency lighting in car: Battery operated emergency lighting in the lift car(xxiii) Intercom system: Battery operated Intercom system in lift car,machine room and ground floor/ control room(xiv) Emergency alarm: Battery operated alarm bell system in lift car and control room/ ground floor(xv) All car panel buttons and all floor switches must be with brail language as per lift act.(xvi) Audio visual indication in the lift car showing overloading shall be provided such that doors are kept open till excess load removed.(xvii) Spring buffer/hydraulic buffers shall be provided.(xviii) Mechanical over speed governor, door key holes in the floor doors shall be provided.(xix) Lift machine hoisting arrangement in the lift machine room and monkey ladder for lift pit should be provided by the lift agency, along with the other steel structure works, foundations for the machines etc.(xx) In the hoist way fascia plate shall be provided.(xxi) Permanent writing in the lift machine room and lift well with proper no. of light point, with fixtures, exhaust fan, plug point and 3 phase 440V power supply shall be made available by the department in the lift shaft, machine room or at desired level(xxii) Car top safety barricade shall be provided 72 (xxiii) ARD (Automatic Rescue Device): Solid state inbuilt automatic rescue device (ARD) for automatic rescue of passengers trapped in the lift car in between floors in the event of power failure. Automatic operation and immediate action in the event of mains failure capable to move the lift to the nearest landing, opens the automatic door of the lift car and floor. Sealed maintenance free battery backup with automatic charging unit and auto changeover device on main failure 73 Note for item No. 59:- Lift of 8 passenger capacity is to be used as passenger lift and as firemen lift to be effective in fire fighting operation. The firemen lift shall have the following requirements.(i) The firemens lift may be used by the occupants in normal times.(ii) The firemens lift shall be provided with a firemen switch. The switch shall be a two position (ON/OFF) switch fixed at the evacuation floor (Normally main entrance floor) for enabling the lift to be put into firemens mode. The switch shall be situated in a glass fronted box with suitable level and fixed adjacent to the lift at the entrance level. When the switch is on, landing call points shall become inoperative and the lift shall be on car control only or on a priority control device. When the switch is off, the lift will return to normal working.(iii) The firemens lift shall be provided with an audio and visual signal in car.(iv) The firemens lift shall have a floor area of minimum 1.43 sqm. It shall have loading capacity of not less than 544kg (8 person lift).(v) The firemens lift shall be provided with power operated (automatic) doors of minimum 0.8 mtr width.(vi) The speed of firemens lift shall be 1 m/s or more such that it can reach the top floor from main floor/ firefighter access level within 1 minute incase of building zoned, the firemens lift shall operate from the lowest served landing to the top most served landing in 1 min. (vii)The words Firemen lift shall be conspicuously displayed in fluorecent paint on the lift landing (viii) All other operation requirements of firemens lift 74 All as per item No. 59 above but lift of 13 passengers capacity (884 kg) 75 FIRE FIGHTING SYSTEM 76 Supply, installation, testing and comminsioning of Common Control Panel suitable for 2 Nos of Electric Motor Driven Hydrant & Sprinkler pump and 01 Nos of Jockey pump with VF drive and soft start will all Protection like over load, under load, dry run etc complete all as specified and directed. 77 Supply, installation, testing and comminsioning of Auto control Panel for Diesel Engine Driven by Fire Pump, complete all as specified and directed. 78 Supply, installation, testing and comminsioning of FRLS, PVC outer sheathed , steel armored, aluminium conductor, 1100V grade power cable and glands etc the cable shall be laid in tray/in conduits, on walls, floor or ceiling etc as required. The rate shall excludes tray and conduits. The minimum size of cable shall be 2 core 1.5 Sqmm complete all as specified and directed. 79 Supply, installation, testing and comminsioning of FRLS, PVC outer sheathed , steel armored, aluminium conductor, 1100V grade power cable and glands etc the cable shall be laid in tray/in conduits, on walls, floor or ceiling etc as required. The rate shall excludes tray and conduits. The minimum size of cable shall be 12 core 1.5 Sqmm complete all as specified and directed. 80 Supply, installation, testing and comminsioning of perforated GI sheet cable tray of size 300mm x50 mm with necessary angle iron suspension supports, anchor fasteners etc complete max height of suspension shall not exceed 500mm size of tray shall be suitable for laying the above mentioned cablescomplete all as specified and directed. 81 Supply, installation, testing and comminsioning of perforated GI sheet cable tray of size 150mm x 50 mm with necessary angle iron suspension supports, anchor fasteners etc complete max height of suspension shall not exceed 500mm size of tray shall be suitable for laying the above mentioned cablescomplete all as specified and directed. 82 Supply, installation, testing and comminsioning of GI earthing strips of 50mmx6mm thick, strip shall be un on floor/ceiling/walls from the equipment to the nearest earth pit shall be executed complete all as specified and directed. 83 Supply, installation, testing and comminsioning of Diesel pump exhaust pipe with super ceramic fiber rope complete all as specified and directed. 84 Supply, fixing, testing & commissioning of butterfly valve (Wafer Type) conforming to IS 13095 class PN 1.6 having SG iron boy and Stainless steel 304 disc, PTFE bush, Nitrile rubber O ring and Carbon steel flow control lever etcall complete as per standard specification and as directed 85 150mm dia 86 100mm dia 87 80mm dia 88 65mm dia 89 Supply, fixing, testing & commissioning of Cast iron Flange ended Foot Valve confirming to IS 4038 having door face seating made out of natural rubber reinforced with special cotton canvas and installing strainer at inlet side etc complete as per standard specification and as directed 90 150mm dia 91 100mm dia 92 Supply, fixing, testing & commissioning of 25mm dia Forged Brass Air release Valve confirming to IS 554, with Polypropylene float, forgedbrass seat and chambr, stainless steel spring, nitrille ring etccomplete as per standard specification and as directed 93 Supply, fixing, testing & commissioning of Anti corrosive treatment for under ground lines with two coats of primer and one coat of 4mm thick readymade Anticorrosive tape complete as per standard specification and as directed 94 Supply, fixing, testing & commissioning of Stainless steel headed ISI marked oblique pattern hydrant landing valves as per IS 5290 with 80mm dia flanged inlet & 63 dia female outlet complete with gun metal capcomplete all as specified and as directed 95 Supply and fix 5 kg capacity MULTI PURPOSE(ABC) type fire extinguisherconforming to IS 15683: 2006, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket/ floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed. Make: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 96 Supply and fix 5 kg capacity DRY CHEMICAL POWDERtype fire extinguisherconforming to IS 2171, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket/ floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed. Make: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 97 Supply and fix 4.5 kg capacity CO2 (Carbon-di-oxide)type fire extinguisherconforming to IS 2171, with initial filling in brand new cylinder with powder coated finish, fitted in gunmetal union, high pressure CO2 gas cartridge, discharge hose, wall mounting bracket/ floor trolley mounting accessories along with suitable signage, etc. complete all as specified and directed. Make: Kanex, Minimax, Aim-EX, Safeguard, Coffco, Variex 98 Supply, installation, testing and comminsioning of 25mm dia Inspection and Testing assembly for sprinkler drain system with thread ended forged bronze valve and sight glass valve with union and necessary fitting complete all as specified and directed. 99 Supply &fixing AUTOGLOW signage in Block/Word/letters of standard sizes in following sentence as given below : 100 FIRE LIFT (Size 4 x 12) 101 EMERGENCY EXIT (Size 4 x 12) 102 FIRE HYDRANT(Size 4 x 12) 103 FIRE HOSE REEL(Size 4 x 12) 104 DCP EXTINGUISHER(Size 8 x 12) 105 CO2 EXTINGUISHER(Size 8 x 12) 106 IN CASE OF FIRE, DO NOT USE LIFT, USE STAIRCASE (8 X 8) 107 FLOW ARROW DIRECTIONS SIGN(8 X 12) 108 FIRE PUMPS NAME & DETAILS OF FLOW CHART 109 OTHER SIGN BOARD AS PER FIRE NORMS 110 Supply, installation, testing and comminsioning of WALL MOUNTED ALARM PANEL with all necessary fitting complete all as specified and directed. 111 Supply, installation, testing and comminsioning of WALL MOUNTED MS SHEET BOX WITH SPEAKER HOOTER SYSTEM with all necessary fitting complete all as specified and directed. 112 Supply, installation, testing and comminsioning of MANUAL CALL POINT WITH HAMMER CHAINwith all necessary fitting complete all as specified and directed. 113 Material and labour forwiring with two runs of 1.5 Sqmmsingle core PVC insulated but unsheathed multi stranded copper conductor FRLSH 1100 volts grade cable drawn through and including PVCconduits heavy duty grade ISI marked 20 mm dia (external) with wall thickness not less than 1.8 mm with conduit accessories complete as specified. Note:All runs of cables and 1 run of conduit shall be measured and paid as one metre length of unit. 114 Supply and fixing DOUBLE AVIATION OBSTLIGHT LED RED with all necessary fitting complete all as specified and directed. 115 LIGHTNING PROTECTION 116 S & F LED red light DIE-CAST aluminimum housing with polycarbonate dome for better illumination with IP-65 protection fixed on wall with clamp by grouting angle iron of size 32x32x6 mm as required complete including suitable size of wiring to the nearest available point complete all as directed . Make : Bajaj Cat Part No BGAV 302 LED and prodect code 110731and Equivalent 117 NOTE : Amount of credit of Rs. 165710.00 for retrieved materials is mentioned in schedule of credit on Srl Page No. 70 of tender documents in pdf form which will be deducted offline while acceptance of tender.
|