supply installation testing and commissioning Of Newly Boring Of Tube /Well At Nanhey Park.- 1 Lowering & Lifting of sub/sets from bore by taking out double flanged GI Pipes, submersible P/Set, Cable, cutting of rusted nuts and bolts etc. andequirement of damaged D/F GI Pipes, cable, defective pump set etc. as per siteequirement and lowering of sub p/set, sub cable, GI Pipe etc. as required, jointing of cable with pipes and jointing of D/F pipes etc. with nuts bolts and rubber packing etc. The job includes hiring of all T&P, tripod stand, chain pulley block and other material handling equipments, Safety gadgets as required and consumable material ( rubber packing and Nut Bolts) will be arranged by the firm as per site requirement DSR Item Code : 27.1.1 to 27.1.7 2 S/O Submersible P/Set dynamically balanced S Steel impeller mounted on stainless steel shaft with protection sleeve duly fitted with flanged tail piece. The pump will be directly coupled with sq. cage sub. Induction motor of 2900 rpm suitable for operation on 3 phase, 415 volts, 50 c/s AC supply with efficiency 70% at duty point of following duties : 7.5 HP, Discharge 350 to 500 LPM, head 45 mtr to 55 mtr.Make :- BS/SU/Skope/DJB approved makes. 3 S/O PVC insulated PVC sheathedflat submersible cable with plain copper conductorhaving three core 4 sq mm415/1100V (each roll 100 mtr)Make :- Havells/Fort Gloster/ICL/CCI/ICC/Universal/Grandlay/Havells/DJB approved 4 Making/supply of 50mm, 3 mtr long approx double flanged (OD 130mm)GI Pipe,mediumconforming to IS:1239(2004)SWS,B Class having 3 No L-Type brackets duly welded on each side of flange. The flanges having four holes and One cut for cable. Make- TATA/Jindal Hisar 5 MS clamp suitable for holding 50 mm dia GI pipe made from 600x100x12 mm thick MS plate with complete set 6 F/S of MS bore cover suitable for 200mm dia MS Pipe. The bore well be fabricated with MS flat size 50mm width 5mm thickness and MS sheet 18SWG in 2 half pieces i/c suitable clamping arrangement having internal hole as per requirement 7 GI double flanged 90 degree 50 mm dia size bend 8 Supply of 50 mm dia. CI double flanged PN 1.0 NRV without bypass. Make :- IVC/Kirloskar 9 Orifice Assembly 50 mm dia. Complete 10 G.I tail piece 50 mm dia 0.5 mtr. Long with one end threaded & other end flanged having 3 No L-Type brackets duly welded with flange having 4 Nos. hole & cut for cable. 11 Supply of chemical dosing pump complete with 100 liter Capacity PVC dosing media container, injection valve assembly, suction valve assembly PVC tubing & accessories for installation, Capacity:- 4 LPH, Pressure:- 5.5 KG/cm2 Make:- Clomax/Milton roy 12 Installation and commissioning of dosing pumps set with proper wall supporting arrangement to hold the pump set , the work includes providing all pipes and special to supply sodium hypo chloride solution properly to main delivery line by making holes with utmost care and make the systems leak proof and testing on full load during the running of pump 13 Making and supply of MS covering with MS angle iron size 40X40X3 mm as per sit requiremenet and height of frame 5 feet complete four side covered frame cover with ms jali 3y 1 SWG duly welded with cross MS strip size 40X6mm and one side opening with locking arrangement at site , making the frame the duly painted with enamel paint after using red oxide metal primer of size 3ftX2ft and height 6 ft. 14 Fixing of ms socket of required size by drilling/threading/welding and making it leak proof fixing suitable nozzle for injecting chlorine solution at the time of operation of t/well . 15 Supply of sodium hypochlorite solution having 9% to 12% available chhlorine packed in 35 litre disposable PVC jerry can make:- Chopra/PACL/BIS approved. 16 A) OUT DOOR TYPE 7.5 TO 10HP Hut type electrical feeder pillar/metal board of welded construction of size 1370mm x 760mm x 460mm fabricated with 16 SWG M.S. sheet with horizontal and vertical intermediate chamber of suitable size on suitable size insulating board to make the Panel Robust, having double door with 14 SWG S.S hinges along with double locking arrangement with arrangement for mounting of switch gear and electrical energy meter i/c powder coating, Vermin proof having following items. 1. MCCB 63 Amp, 4 Pole-1 No 2.RCCB/ELCB 63 Amp, 4 Pole with earth fault indicator and positive contact indication protecting a circuit automatically 1No 3.Fully automatic star delta starter of 10HP, 3Phase oil immersed type 1No 4.Digital Ampere meter 96mmx96mm square shape of 0-30 Amp range 1No 5.Digital Voltmeter of 96mm x 96 mm square shape of 0-500 Volt range with selector switch 1No 6.LED Indicating lamps with fitting (a set of 3 lamps) 1Set 7.Shunt capacitor of 5 KVAR with three phase isolator 1No 8.Motor Protection Assembly having Earth Leakage protection, Phase sequence corrector, Single phasing protection, Over load protection, High voltage-low voltage protection. 1No 9.Programmable time switch (i.e. RYB Phase & facility to change over from automatic to manual & vice versa) up to 10 H.P.1No 10.Complete wiring of panel board & installation of electrical accessories in the panel with required copper conductor wire & thimbling etc as required. The panel board shall be mounted on the base frame of 600mm height made of 50x50x6mm angle iron frame.Make:-All the insert used in Panel must be of DJB approved makes and should be ISI marked where make of that equipment is not approved. 17 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required 18 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 19 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut,bolt, spring, washer excavation and re-filling etc. as required. 20 Grouting of existing LT Panel with 1:2:4 C:C material. Work includes grouting of both legs with C:C material to provide proper strength. 21 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVS insulated copper conductor single core cable in surface/ recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.DSR 1.1 2022 Group B 22 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.DSR 1.14 2 × 1.5 sq. mm + 1 × 1.5 sq. mm. earth wire 23 2 × 2.5 sq. mm + 1 × 2.5 sq. mm earth wire 24 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.DSR 1.23 20225/6 amps switch 25 3 pin 5/6 A socket outlet 26 15/16 A switch 27 6 pin 15/16 A socket outlet 28 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.DSR 1.30 2022 29 Supply of LED Batten of 20 WattMake :- Orient/Philips/Bajaj/Havells. 30 Installation, testing and commissioning of pre-wired, florescent fitting/ compact florescent fitting of all types, complete with all accessories and tube/ lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.DSR 1.41 2022 31 Supplyof 72Watt LED light.Make of 70 W LED: Bajaj/Crompton/Philips/Havells. 32 Supply of MS Angle of size 50x50x5mm.(for 01 Tube well MS Angle = 12 Kgs) 33 Supply of MS Chequered Sheet of thickness 06 mm.(for 01 Tube well MS Sheet = 27 Kgs) 34 Fabrication/Cutting the MS Chequered Sheet of 06 mm with the help of gas cutter, grinder. 35 Fabrication of MS angle of size 50x50x5 mm frame with the help of gas cutter, welding machine, grinder and making the frame of roof opening of size 2.6 x 2.6 sq. ft. Welding the above MS chequered sheet on the MS angle frame with hinges and handle for opening. 36 Fixing the MS Roof cover on the tube well with C:C material in the ratio 1:2:4 and along with other hardware items required as per site requirement. 37 Painting the complete MS Roof covers first with Primer and then two coats of enamel paint.
|