On-grid Electrification of Households under DA-JGUA in District Rajouri (UT of Jammu and Kashmir) for JPDCL under the Revamped Reforms-based and Results-linked, Distribution Sector Scheme (RDSS)=- 1 8 Mtr. Long Pole (ST-410 SP15) 2 9 Mtr. Long Pole(ST-410 SP33) 3 11 Mtr. Long Pole(ST-410 SP56) 4 30 mm² ACSR Conductor 5 50 mm² ACSR Conductor 6 11/0.433-0.250KV;50Hz,25 KVA Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment. 7 11/0.433-0.250KV;50Hz, 63 KVA Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment with xternally fitted MCCB with cable box and 4x4 Mtrs. suitable cable of ratings. Aluminium wound upto 200kVA, Copper wound for 250kVA or higher kVA ratings) 8 LT Distribution Box for 25 kVA DTR withMCCB for incomer & Outgoing Circuits 9 LT Distribution Box for 63 kVA DTR withMCCB for incomer & Outgoing Circuits 10 Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type 11 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type 12 11 kV Horn GapFuse Set 3 Phase 200A 13 GI V cross-arm with top Bracket including clamp 14 GI Channel X-arm including clamps and braces 15 GI Channel/Angle/Flat of sizes including clamps 16 Galvanized Nuts and Bolts 17 PG Clamps for 50 mm² ACSR Conductor 18 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm 19 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm 20 25 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type 21 70 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type 22 GI Rod 20mm 2.5 mtr long through GI Strip. 23 Earthing of substation --Excavation ofearth pit of dia650 mm & depth 3000 mm, installation ofEarthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. 24 Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete 25 Danger Plates with Clamps 26 Anti-Climbing Device with Clamps 27 Red Oxide 28 Aluminium Paint 29 Aluminium Jointing Sleeves 30 GI U-Clamps for Shackle Insulators 31 16kN Polymer Shackle Insulators 32 LT Line Spacers 33 32/63 amps TPN Switch Disconnector Fuse Unit 34 Sundry items like aluminium lugs, Jumpers, binding Tape, 35 Wedge Connectors / PG Clamps 36 3-Ø, 4-Wire Trivector Meter with CT 37 Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole 38 Cement bottoming 1:2:4 mix as per REC standards .5cum /pole 39 GI Barbed Wire for Anti Climbing Device
|