Indian Tenders

Tender Notice

TDR 49767979
Tendering Authority Indian Institute Of Technology
Tender No IITKGP/CD/P/PS/25-26/02
Tender ID 2025_IITKG_864054_1
Tender Brief Corrigendum : Tender For Design, Site Preparation, Supply, Installation, Testing, Commissioning, And Amc Services Of Basic Infrastructure For The Establishment Of A Data Center At Centre For Computational And Data Sciences (Ccds), Iit Kharagpur , A. Particulars(Su
City kharagpur
State West Bengal
Document Fees INR 2500 /-
EMD INR 4000000.0 /-
Tender Value INR 12 Crore /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Design, Site Preparation, Supply, Installation, Testing, Commissioning, And Amc Services Of Basic Infrastructure For The Establishment Of A Data Center At Centre For Computational And Data Sciences (Ccds), Iit Kharagpur , A. Particulars(Supply) (Price Per Unit In Rs. To Be Entered In The Sl No. 5 And Gst Amount (Per Unit) To Be Entered In Rs. In Sl No. 6) , Civil Works For All Partitions, Fire Rated Glass Works, Doors, False Floor, Road Cutting And Making Good, Building Front Tile Removing Excavation And Filling Up Any Support System, External Wall, Wire Mesh Boundary, Paver Blocks, Wall Breaking And Finishing, External Panel Room. , False Flooring Works (Dc & Electrical Room), Steps & Ramps, Civil And Gypsum Partition, Glass Wall Partitions, Fire Doors, Ante Room, Battery Room Civil Works (Breaking And Finishing Walls), Painting, Finishing, Signages, Branding Works. Grilles/ Tiles Etc. As Required. , Adiabatic Dry Cooler System Along With Pump, Tank, Piping, Controls Panel, Vfd, Pid Controller, Instrumentation As Per P & Id, Adiabatic Tank Etc., Make Up Water , Air Cooled Chiller Plant With Control Panel, Chiller Plant Manager, Auto Restart Feature For Chillers On Restoration Of Power/ Failure Mode, Associated Sensors, Controllers Control Cablings Etc. Pumps, Vfds, Piping Buffer Tanks, Pressurization System, Chemical Dozing System , Chilled Water Pahu With Control Panel, Auto Changeovers, Auto Restart Feature , Chilled Water Rdhx For Data Center Area Along With Flexible Pipes & Controls , Self-Contained Floor Mounted Refrigeration Dehumidifier Derated For 22Oc Operations With Associated Sensors, Controllers Etc. , Ups System With Isolation Transformers For 500Kva And With Incoming And Outgoing Panels As Per Sld. , Ups System With In Built Isolation Transformers For 50Kva With Outgoing Panels As Per Sld. , Li Ion Battery Pack With 10 Minutes Back Up At End Of Life For 500Kva It Loads With 5 Years Warranty , Smf Vrla Battery For Non-It Loads With 15 Minute Back Up , Modification Of Existing Electrical Panels, And Sitc Of Panels And Rest Of Electrical Works As Per Sld. 2 Incoming Panels, 4 Outgoing Panels And Additional Non It Distribution Panel As Required. , End Feed Systems, Bus Ways, Hot Swappable Tap Off Boxes/ Plug In Boxes With 3 X 32A & 1 X16a Iec 60309 Female Receptacles In Each Of 9 Tap Off (2 Spare) Boxes. (Alternative Design May Be Considered To Suit Site/ Bus Ways), 5 Tap Off Boxes (1 Spare) Each With 2 X 40A Plug Ins With Isolators. , Electrical Work As Lighting System Emergency And External Raw Power Lighting, Pump & Dry Cooler Panel Along With Cabling Etc. Earthing Systems With Earth Pits Cable Trays/ Racks/ Etc. Smoke Exhaust System. , I Bms System With Sensors, Cabling, Racks, Computers, Etc. , 800 X 1400Mm/ 1300Mm Racks With Intelligent Pdus With Leveling Etc. Suitable Of 2 Source Power Connections From Top And Provision For Rdhx Installation, Including 2 Sets Of Power Cabling With Connectors To Connect From Tap Off Boxes To Pdu. , Diesel Generator Sets With Day Tanks And Self Standing & Supported Chimneys, Earthing, Fuel Management System, Cabling, Synchronizing Panel, Battery With Chargers, Self Starting, Ats Panel, Fuel Flow Meters And Run Hours With Bms Compatibility For Data Logging. , 2 Years Warrantee For Performance And Workmanship Along With Consumables. , O&M: Deployment Of Onsite Bms, Mep Operators And Supervisor As Per Annexure-K , B. Particulars (Installation) (Price Per Unit In Rs. To Be Entered In The Sl No. 5 And Gst Amount (Per Unit) To Be Entered In Rs. In Sl No. 6) , Civil Works For All Partitions, Fire Rated Glass Works, Doors, False Floor, Road Cutting And Making Good, Building Front Tile Removing Excavation And Filling Up Any Support System, External Wall, Wire Mesh Boundary, Paver Blocks, Wall Breaking And Finishing, External Panel Room. , False Flooring Works (Dc & Electrical Room), Steps & Ramps, Civil And Gypsum Partition, Glass Wall Partitions, Fire Doors, Ante Room, Battery Room Civil Works (Breaking And Finishing Walls), Painting, Finishing, Signages, Branding Works. Grilles/ Tiles Etc. As Required. , Adiabatic Dry Cooler System Along With Pump, Tank, Piping, Controls Panel, Vfd, Pid Controller, Instrumentation As Per P & Id, Adiabatic Tank Etc., Make Up Water , Air Cooled Chiller Plant With Control Panel, Chiller Plant Manager, Auto Restart Feature For Chillers On Restoration Of Power/ Failure Mode, Associated Sensors, Controllers Control Cablings Etc. Pumps, Vfds, Piping Buffer Tanks, Pressurization System, Chemical Dozing System , Chilled Water Pahu With Control Panel, Auto Changeovers, Auto Restart Feature , Chilled Water Rdhx For Data Center Area Along With Flexible Pipes & Controls , Self-Contained Floor Mounted Refrigeration Dehumidifier Derated For 22Oc Operations With Associated Sensors, Controllers Etc. , Ups System With Isolation Transformers For 500Kva And With Incoming And Outgoing Panels As Per Sld. , Ups System With In Built Isolation Transformers For 50Kva With Outgoing Panels As Per Sld. , Li Ion Battery Pack With 10 Minutes Back Up At End Of Life For 500Kva It Loads With 5 Years Warranty , Smf Vrla Battery For Non-It Loads With 15 Minute Back Up , Modification Of Existing Electrical Panels, And Sitc Of Panels And Rest Of Electrical Works As Per Sld. 2 Incoming Panels, 4 Outgoing Panels And Additional Non It Distribution Panel As Required. , End Feed Systems, Bus Ways, Hot Swappable Tap Off Boxes/ Plug In Boxes With 3 X 32A & 1 X16a Iec 60309 Female Receptacles In Each Of 9 Tap Off (2 Spare) Boxes. (Alternative Design May Be Considered To Suit Site/ Bus Ways), 5 Tap Off Boxes (1 Spare) Each With 2 X 40A Plug Ins With Isolators. , Electrical Work As Lighting System Emergency And External Raw Power Lighting, Pump & Dry Cooler Panel Along With Cabling Etc. Earthing Systems With Earth Pits Cable Trays/ Racks/ Etc. Smoke Exhaust System. , I Bms System With Sensors, Cabling, Racks, Computers, Etc. , 800 X 1400Mm/ 1300Mm Racks With Intelligent Pdus With Leveling Etc. Suitable Of 2 Source Power Connections From Top And Provision For Rdhx Installation, Including 2 Sets Of Power Cabling With Connectors To Connect From Tap Off Boxes To Pdu. , Diesel Generator Sets With Day Tanks And Self Standing & Supported Chimneys, Earthing, Fuel Management System, Cabling, Synchronizing Panel, Battery With Chargers, Self Starting, Ats Panel, Fuel Flow Meters And Run Hours With Bms Compatibility For Data Logging. , 2 Years Warrantee For Performance And Workmanship Along With Consumables. , O&M: Deployment Of Onsite Bms, Mep Operators And Supervisor As Per Annexure-K , C. Additional Items (Price Per Unit In Rs. To Be Entered In The Sl No. 5 And Gst Amount (Per Unit) To Be Entered In Rs. In Sl No. 6. These Items Will Also Be Considered For Computing L1) , Comprehensive Annual Maintenance Contract -Year-3 , Comprehensive Annual Maintenance Contract -Year-4 , Comprehensive Annual Maintenance Contract -Year-5 , Operation And Maintenance –Year-3 , Operation And Maintenance –Year-4 , Operation And Maintenance –Year-5

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 23-06-2025 Corrigendum 1 Technical Bid 21-07-2025
2 26-06-2025 Corrigendum 2 Date 21-07-2025

Key Dates

Publish Date 26-06-2025
Last Date of Bid Submission 21-07-2025
Tender Opening Date 22-07-2025

Contact Information

Company Name Indian Institute Of Technology
Contact Person HEAD, Centre for Computational and Data Sciences
Address Centre for Computational and Data Sciences (CCDS), IIT Kharagpur, 721302, West Bengal

Other Detail

Information Source https://eprocure.gov.in/eprocure/app
Download FileName File Description File Size
Download 12a4ba18-74a6-47d8-a7f6-39ff2c5d6cec.html Tender Documents 0 KB
Download BOQ_908405.xls Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB