| 1 | Wiring for light / fan / exhaust fan / call bell point with 2 x1.5 sq. mm pvc insulated Copper conductor cable (FR) in pvc casing and capping complete with 6/10 amps modular type switch, cover plate, surface modular switch board including connection etc as required:- |
| 2 | Short Point :- |
| 3 | Medium Point :- |
| 4 | Long Point :- |
| 5 | Providing and fixing of 3 pin 5/6 amps plug point withpianotype 5/6ampsswitch andsocketincludingconnectionwith 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) onswitch board, earthing the 3rd pin etc. as required:- |
| 6 | Providing and fixing of 3/6 pin15/16 amps plug point withpianotype 15/16ampsswitch andsocketincludingconnectionwith 2x2.5 sq. mm PVC insulated Copper conductor cable (FR) onswitch board, earthing the 3rd pin etc. as required:- |
| 7 | Providing and fixing of 3 pin 6/10 amps plug point withmodulartype 6/10ampsswitch andsocketincludingconnectionwith 2x1.5 sq. mm PVC insulated Copper conductor cable (FR) on surface modularswitch board, earthing the 3rd pin etc. as required. |
| 8 | Providing and fixing of 3/6 pin 16/20 amps plug point withmodulartype 16/20ampsswitch andsocketincludingconnectionwith 2x2.5 sq. mm PVC insulated Copper conductor cable(FR) on surface modular switch board, earthing the 3rd pin etc. as required. |
| 9 | Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required. |
| 10 | 2 x 1.5 sq.mm:- |
| 11 | 2 x 2.5 sq.mm:- |
| 12 | 2 x 4 sq.mm:- |
| 13 | 2 X 6 sq mm |
| 14 | 4 X 10 sq mm |
| 15 | Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:- |
| 16 | 1 X 1.5 sq mm |
| 17 | 1 X 2.5 sq mm |
| 18 | 2 x 2.5 sq.mm:- |
| 19 | 2 x 4 sq.mm:- |
| 20 | 2 x 6 sq.mm:- |
| 21 | Earthing with 40 mm dia G.I. Earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top CI cover plate size 12\"x 12\" having locking arrangement including CC work, holes on earth pipe etc. as required. |
| 22 | Extra for using salt (5 kg) and charcoal (94kg) for pipe earth ectrode as required. |
| 23 | Proving and fixing / drawing of 4.06 mm dia (8 SWG) G.I. wire on surface or in existing G.I/ PVC/ Polythene pipe for loop earthing as required. |
| 24 | Providng and laying 15mm dia(medium gauge) G.I. pipe for drawing of4.06mm (8SWG) dia G.I./ Copper wire forearth connection from earth electrodes etc as required. |
| 25 | Supply and fixing of 25mm x 5mm G.I strip on walls/ floor of the building for horizontal/ vertical network including necessary spacers and porcelain insulators at regular intervals. |
| 26 | Supply and fixing of the following sizes GIprongwith necessary nuts & bolts etc as required grouted on roof for Lightning protection. |
| 27 | G.I Prong 450 mm long |
| 28 | Supplying & fixing of 1200 mm sweep white color AC ceilingfan capacitor typedouble ball bearing complete with 300 mm down rod,canopies,shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm PVC insulated Copper conductor cable(FR)(ISI marked, BEE 1star/minimum service value 4.0 m3/min/W) |
| 29 | Supplying and fixing of 20 mm dia extra down rod (GI Pipe Medium Guage) with necessary hole for installation of ceiling fan as required. |
| 30 | Supplying and fixing of the following modular accessories including necessary connection etc. as required. |
| 31 | Bell push SP (1M) :- |
| 32 | 5 step fan regulator (2M):- |
| 33 | Supplying and fixing of the following electrical accessories including necessary connection etc. as required. |
| 34 | Musical call bell |
| 35 | 32 amps DP kit kat switch:- |
| 36 | Supplying and fixing of the following sizes wooden switch boards with 3mm thick bakelite cover etc. as required. |
| 37 | 102mm x 178mm (4\" X 7\") :- |
| 38 | 54mm x 300mm (10\" X 12\") :- |
| 39 | Supplying and installation of Switch disconnector fuse unit (main switch) of the following ratings with all accessories including necessary connection etc. as required:- |
| 40 | 32 amps 240 volts DP main switch (rewireable):- |
| 41 | 32 amps 415 volts TPN main switch (rewireable):- |
| 42 | 63 amps 415 volts TPN main switch (rewireable):- |
| 43 | Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:- |
| 44 | 63 amps 415 volts four strip Copper busbar chamber 6 ways of size (455 mm x 330 mm x 120 mm):- |
| 45 | 32 amps 415 volts four strip Copper busbar chamber 4 ways of size (300 mm x 240 mm x 80 mm):- |
| 46 | Supplying and installation of fuse unit kitkat/HRC/HBC of the following ratings in existing main switch/panel board including necessary connection etc as required:- |
| 47 | 63 amps kitkat porcelain fuse unit with base(rewireable):- |
| 48 | Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connectionas required. |
| 49 | 2 way SPN MCB DB (single door):- |
| 50 | (2+6) / 8way SPN MCB DB (double door):- |
| 51 | (2+10)/12 waySPN MCB DB (Double Door) |
| 52 | Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connectionas required: |
| 53 | 6 to 32 amps SP MCB |
| 54 | 6 to 32 amps DP MCB |
| 55 | Supplying & installation of Isolators of following ratings in the existing MCB DB in/c connection etc as rwequired: |
| 56 | 40 amps DP Isolator |
| 57 | Supplying and fixing of following surface/recess mounted LED luminaries in powder coated die cast housing complete with high efficiency polycarbonate diffuser and necessary connection etc.as required (with 50000 burning hours and minimum lumen output of 100 lm/watt): |
| 58 | Surface mounted integrated 20 watt LED batten with polycarbonate diffuser:- |
| 59 | Recessed round/Square shaped 12 watt LED downlight with integral driver and high quality polycarbonate diffuser:- |
| 60 | Supplying and fixing of following luminaries complete withnecessary accessories and connection etc. as required (Commercial lighting fixtures with 50,000 burning hours):- |
| 61 | Box type double FTL fittings of CRCA steel sheet housing complete with 2 nos. 36/40 W FTL,electronic ballast and high quality reflector cover: - |
| 62 | Bulk head fittings with frosted/clear glass suitable for GLS or retrofit CFL/LED (without lamp) : - |
| 63 | Supplying and fixing of following LED Tubes, retrofit bulbs/lamps for LED luminaries including necessary connection etc. as required:- |
| 64 | 9 watt LED retrofit lamp with polycarbonate body and aluminium heatsink :- |
| 65 | Supplying and fixing of following outdoor LED luminaries in powder coated die cast housing complete with heat resistant tempered glass/diffuser including necessary connection etc. as required (50000 burning hours and minimum lumen output of 100 lm/watt):- |
| 66 | 45 watt LED street light fixture with integral driver and secondary lens (IP 66):- |
| 67 | Supplying & installation of 300 mm sweep metalic body exhaust fan including connection etc as required:- |
| 68 | Supplying & installation of shutter for 225/230/300 mm sweep metalic body exhaust fan in the existing hole as required:- |
| 69 | Supplying of ‘U’ clamp made with 40mm x 6 mm MS flat and fixing with necessary fasten nuts including painting etc as required. |
| 70 | Supplying and fixing of MS frame made of (25mm x 25mm x 5mm) MS angle with necessary support by (40mm x 6mm) MS flat and 12 mm thick marine plywood on top, grouted on wall with 4 noslegs (25mmx25mmx5mm MS angle20 cm long) finishedwith red oxide and 2 coat synthetic enamel paintincluding necessary cc work, mending the damages & painting etc as required: |
| 71 | Supplying and fixing of the following PVC conduit (medium gauge) with all accessories on slab/recessed on wall etc as required. |
| 72 | 25 mm dia. |
| 73 | Supplying & fixing of G.I. pipe (medium gauge) bracket fabricated at suitable angle for fixing of outdoor light on wall/ RCC base with necessary MS clamp, nut, bolt etc as required:- |
| 74 | 40 mm dia. |
| 75 | Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required |
| 76 | 3 core 4 sq mm |
| 77 | Drawing of armoured/un-armoured cable with proper saddling etc as required:- |
| 78 | Dismantaling existing electrical equipments and accesssories |