Tender For Special Repair To Bldg No P 29 At Ota Gaya; 1 Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. 2 M & L for Reinforced cement concrete (nominal mix) Type B1 1:2:4 (20 mm graded stone aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like completed all as specified and directed. 3 M & L for use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished flat surface of concrete complete all as specified and directed. 4 M&L for Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete. 5 Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. 6 M&L for Cement concrete Type C2 (1:3:6) (40 mm graded aggregate) in foundations, filling,sub base and mass concrete complete.All as specified and directed. 7 Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. 8 M&L for 20mm thick granite slab, machine cut, well polished, bedded in 15mm thick in CM 1:4 as in cooking plaforms & like and jointed with grey cement slurry and pointed with white cement(1:2) using marble dust with admixtures of pigments to match the shade of granite stone including cutting, polishing and rounding of edges etc. complete all as specified and directed. 9 M & L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exc 0.06 Sqm but not exc. 0.16 Sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer with CM (1:4) complete. All as specified and directed. 10 M & L for coloured glazed ceramic tiles in vertical surface7mm thick, area of each tile exc 0.06 Sqm but not exc. 0.20 Sqmset and jointed in neat cement slurry and pointed in white or colour cement to match incl 10mm thick rendering in cement mortar (1:4)as backing for tiles complete all as specified and as directed. 11 M&L for vitrified Ceramic tiles light shed 9-10 mm thick (square/ rectangular) polished, area of each tiles notexceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 15mm thick screed bed or bedding layer with CM (1:4)complete. All as specified and directed. 12 All as per ser item No 11 above but as in vertical surfacesin skirting and dado including rendering/screeding including cement mortar1:4 , 10mm thick complete. 13 M & L Machine cut Kota stone slab flooring 18-22 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing over and including screed bed or bedding layer of mortar 20 mm thick Cement Mortar (1:6) complete. 14 M & L Kota stone slab 15-20 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and incl 10mm thick rendering in cement mortar 1:4 , on fair faces of brick work or concrete surfaces as backing complete.(Note : Work will be carried out as in repair of patches in lieu of existing broken flooring) 15 M & L for Cement concrete type B-0, 1:2:4 (12.5 mm graded aggregate), 25 mm thick in flooring etc complete all specified anddirected 16 M&L for preparation and filling of pitting/cracks (including V groove cutting of cracks/deepening) on surfaces with crack seal and finishing the surfaces as per existing treatment complete all as specified and directed. 17 M&L for repairing of R.C.C projections, chajjias, roofs, facia etc in patches not exceeding 3 Sqm in each patch by necessary preparation, Scarpping, cutting, chiseling, derusting and cleaning exposed reinforcement, surfaces of damaged, loose R.,C.C surfaces and applying one coat of cement slurry and filling the surfaces with cement concrete (1:1.5:3) using 12.5mm graded crushed stone aggregates and finished with cement and sand motar (1:3) using coarse sand and work in patchesincluding necessary form work and applyingtwo coats of finishes to match with the existing surfaces in at any height complete all as specified and directed by Engr-in-charge. 18 S & F thin flexible galvanised steel wire with hexagonal gaps chicken wire mesh about half to one inch dia incl fixing with screws, nails etc complete.All as specified and directed. 19 M&L for cleaning and racking out the joint filling of floor or wall tiles and refilling the same with white or coloured cement to match the existing colour.Complete all as specified and directed. 20 Disconnecting existing PVC water storage tanks of capacity exc 500 ltrs & n exc 1000 ltrs, setting aside (or lowering if required) for laying of APP memberane or repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. Complete all as specified and directed. 21 M & L for providing water proofing treatment over cleaned roof surface with super thermo APP modified polymeric membrane comprising of followings :- (i). Complete removal of existing roof treatment by picking, sweeping clean and washing down with water to remove dust etc from plastered / roof surface / walls and filling the crackes with sealing compound grade A .(ii) Rendering / screed bed 15 mm thick in cement mortor (1:4) mixed with liquid water proofing compound as per manufacturers instructions andfinished the surface fair and even. (iii) Applying evenly a coat of bitumen based primer conforming to IS-3384-1965 @ 0.30 Kg/Sqm.(iv) Applying 3 mm thick APP modified polymeric membrane with non polyster reinforcement of approved make, weight not less than 3.50 Kg/Sqm laid with gas torch and fastedon roof surface with roller. The over laps 100mm and shall be sealed by torch application as per manufacture instructions including vertical surfaces after cutting necessary grooving and making good with PCC 1:2:4 type B-O with sika latex power as per manufacture instructions.(v) Applying two coats of heat resisting paint/solar reflective paint coatingover polymeric membrene. Note :- WPC shall be measured and paid separately. 22 Dismantling of existing sunken treatment including plaster and M & L for water proofing treatment on existing sunken portion with the following specification complete all as specified and directed :-(a) 15 mm thick (average) plaster on sunken floor in CM (1:4) with waterproofing compound as per manufacturer instruction complete all as specified & directed . (b) Apply bituminous primer @0.50 Kkg/Sqm conforming to IS 3384-1965 on prepared surface till the surface is properly impregnated.(c) Apply hot bitumen 85/25 grade @ 1.20 kgs/sqm confirming to IS 702-1988. (d) Laying polymeric water proofing memberae weight not less than 3.0 kgs/sqm as per manufacturer instructions confirming to IS. (e) Apply layer of blown grade bitumen 85/25 @ 1.2 Kgs/Sqm confirming to IS.(f) One spout of 40 mm GI pipe shall be provided in sunken floor and sunken porion shall be filled with lean concrete Type E-2 (1:5:10) using brick aggregate complete. 23 Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. 24 M&L Brick work using old size bricks with sub class B bricks straightor curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as spd and directed. 25 M & L for brick work with sub class B bricks, in half brick thick wall, straight or curved on plan exc 6m mean radius built in CM 1:4 complete. All as specified and directed. 26 Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. Complete all as specified and directed. 27 M & L for rendering 10mm thick internal surfaces on fair faces of brick or concrete surfaces in cement plaster 1:6 and finished even and smooth (without using extra cement) complete all as specified and directed. 28 M&L for rendering 10mmthick in ceiling on brick work or concrete surfaces in CM 1:3, finished even and smooth without using extra cement all as specified and directed. 29 M & L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement plaster 1:4 using WPC 3% by weight of cement (WPC to be measured and paid separately) and finished even and smooth (without using extra cement) completd all as specified and directed 30 Supply Only integral water proofing compound 31 M & L for applying a thin layer of 1.0mm thick white wall care putty over newly plastered surface toprepare the surface even and smooth complete all as specified and directed. 32 M & L for preparation of new plastered/decorated wall surfaces and applying two coats of distempering with oil bound distemperas per manufacturer instruction white or tinted complete all as specified and directed. 33 M & L for preparation of new plastered/decoarated wall surfaces and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed. 34 M&L for two coats of oil bound distemper on newly plastered surfaces of celling including prepration of surfaces complete all as specified and directed. 35 M & L for applying a thin layer of 1.0mm thick Birla white putty/JK white wall care putty on wall surfaces including removal of existing treatment and making the surface uniform and smooth complete all as specified and directed. 36 M & L for Preparation of old decorated surfaces of walls and applying two coats of distempering with oil bound distemper as per manufacturer instructions white or tinted complete all as specified and directed. 37 M & L for Preparation of old decorated surfaces of ceiling and applying one coat of distempering with oil bound distemper as per manufacturer instructions white or tinted complete all as specified and directed. 38 M&L for one coat of exterior weather coat paintwhite or tinted on walls or fascia of roof or chajjas on old decorated prepared plastered/painted surfaces of bldg all as specified & directed. 39 Taking down chowkat or frame with shutter (without taking off shutters from the frames) areaexceeding n exc 1.5 Sq mtr each. Completed all as specified and directed. 40 Taking down chowkhat or frame exc 1.5 sqm but not exc 4.00 sqm (without taking off shutter) and removing to store/taking in safe custody for refixing the same complete all as specified and directed. 41 S & F solid PVC frame of size 50 mm x 47 mm made out of 5 mm single side prelam PVC sheet & edges will be printed to match with prelam sheet rein forced with MS square tube etc. Completed all as specified and directed. 42 S&F factory made solid panel PVC door shutter 30mm (Style) consisting of frame made out of M.S tubes for top and bottom rails M.S frame shall be covered with heat moulded plain colour PVC C channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheets to be fitted in the M.S frame welded/sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in the frame completed all as specified and directed. 43 S & F 100mmButthinges, heavy weight, cold rolled mild steel, and fixed complete. All as specified and directed. 44 S&F 150 mm long aluminium anodised barrel tower bolt and 12 mm dia fixed completed all as specified and directed. 45 S&F 150mm long aluminium anodised handle cast type and fixed D Type completed all as specified and directed. 46 S&Falluminum alloy, anodised, cast type or extruded section, sliding door bolt with hasp & staple (bolt type) with fixing clips and bolts and 250 mm long complete all as specified and directed. 47 S&F anodized aluminium frames with powder coating (minimum thickness of powder coating 50 micron) for sliding doors,windows, ventilators etc with one or more rebates including jointing cleat for fixing etc.complete all as specified and specified directed. 48 S&F anodised aluminium door shutter with powder coating (minimum thickness of powder coating 50 micron) aluminium sections weighing not less than 1.0 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door,anodised aluminium hinges, snap beading, screws,etc complete all as specified and directed. 49 S&F anodised aluminium window(Sliding or side hung shutter) and ventilator shutters, with powder coating (minimum thickness of powder coating 50 micron) side hung/ sliding type without sash bars, aluminium sections weighing not less than 1.0 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21,100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed. 50 S&F Sheet glass 5.5 mm thickness, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each panecompleted all as specified and directed. 51 M&L 6 mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice laminationfixed with screws/beading to timber/aluminium frame work or as required on site including fixing arrangement complete all as specified and directed. 52 S&F galvanised stainless steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised wire staples or screw complete all as specified and directed. 53 S & F 3 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads or rubber beading in squares of any size complete all as specified and directed. 54 S&F 4mm thickfigured glass pin head type and glazing with oil putty or wooden beads or rubber beading in squares n exc 0.50 Sqm each pane complete all as specified and directed. 55 S & F in repair white colour rotational three layer moulded polyethylene water storage tanks (cylinderical vertical with closed top) capacity 1000 Ltrhoisted and fixed in position all as specified and directed. 56 S & F 25mm dia bore ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed. 57 S & F 25mm dia bore CPVC gate valves with handle or wheel head, screwed both ends for pipe and fixed. 58 S & F 20mm dia bore CPVC gate valves with handle or wheel head, screwed both ends for pipe and fixed. 59 Supplying and laying as in repair of CPVC pipes 20mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified or laid in floors concealed or open of any length including taking down or up existing GI tubing & connections all as specified and directed by. 60 Supplying and laying as in repair of CPVC pipes 25mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified or laid in floors concealed or open of any length including taking down or up existing GI tubing & connections all as specified and directed. 61 Supplying and laying as in repair of CPVC pipes 32mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified or laid in floors concealed or open of any length including taking down or up existing GI tubing & connections all as specified and directed. 62 Cutting chases, pinning in, making good to facing where reqd and pointing in CM 1:3 to ends of edges of landing etc and cutting chases for concealed water tubing and making good cutting exc 10 cm but n.exc 20 cm girth.completed all as specified and directed. 63 S & F of 20mm dia Male Brass Threaded Adaptor (MTA/ MBTA)or Female Brass Threaded Adaptor (FTA/ FBTA) complete. 64 S & F of 25mm dia Male Brass Threaded Adaptor (MTA/ MBTA)or Female Brass Threaded Adaptor (FTA/ FBTA) complete. 65 S & F of 32mm dia Male Brass Threaded Adaptor (MTA/ MBTA)or Female Brass Threaded Adaptor (FTA/ FBTA) complete. 66 S & F in repair Vitreous China wash down water closet pan (pedestal pattern), white including fixing bolts, but excuding flushing cistern and flush pipe complete all as specified and directed. 67 S & F as in repair normal closing white Seat Cover forEWC incl all accessories complete all as specified and directed. 68 S & F as in repair 10 litre PVC valveless, syphonic action type, flushing cistern,low level, white, with inlet,ball valve, float and handle including brackets 69 S & F as in repair chromium plated health faucet 15 mm with flexible tube (1.20 to 1.50 mtr chromium plated) provided rubber hose and wall hook etccomplete all as specified and directed 70 S&F in repairs 15mm dia bore stop cock /Angle valves cast copper alloy chromium plated fancy type with long shank & cup complete all as specified and directed. 71 S&Fin repair PVC floor trap size 75/100mm dia out let with grating including connection to waste pipe with cement jointing including taking down existing trap complete all as specified and directed 72 S&F in replacement 32mm dia PVC waste pipe for WHB complete all as specified and directed. 73 S & F in repair 6mm thick looking mirror of 1st quality glass, mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete. completed all as specified and directed. 74 S & F in repair 600mm long brass chromium plated tubular towel rail 20mm dia, D type fixed with rawl plugs in cement mortar 1:3 with MS screws complete all as specified and directed. 75 S & F in repair brass chromium plated soap dish fixed to wall with CP screw complete all as specified and directed. 76 S & F in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 45cm long complete all as specified and directed. 77 S&F 4mm thick superior quality shelves (corner), made of transparenttoughened glass, size 30x30cm complete all as specified anddirected. 78 S & F in repair vitreous China Urinal, Half stall type, white incl providing and fixing plugs, bedding urinal against wall in CM 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixing of flush pipe, grating and union for discharge pipe complete. completed all as specified and directed. 79 S & F in repair 15 mm dia bore fancy type chromium plated bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed. 80 S&F in repair 15 mm dia two way angle valves/Bib taps, cast copper alloy,fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions completed all as specified and directed. completed all as specified and directed. 81 S & F as in repair brass chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union all as specified and directed. 82 S&F as in repair PVC connections 15mm size with PTMT nuts of length 600 mm all as specified and directed. 83 Supply & fix in repair brass chromium plated wall mixer (2/3 hole) with provision for connection to shower rose for mixing hot and cold water screwed down for iron pipes suitable for 15mm bore pipe complete all as specified and directed. 84 Dismantling of wall and ceiling boards, any thickness including cover fillets complete. completed all as specified and directed. 85 S&F in repairs of 4 mm thick HPSC (High Pressure steam cured) pre-primed textured designer board, water resistant, be placed in the grid system all as specified and directed. 86 Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete.completed all as specified and directed. 87 M&L for PVC (SWR) pipessingle socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 110 mm bore of pipe etc complete all as specified and directed. 88 S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints,fixed to walls.Make- Reliance, fnolex,Supreme, Kisan, Prince all as specified and directed. 89 M&L for PVC (SWR) pipessingle socketed, in any length with rubber ring joints, laid in trenches or in floors or walls of 75 mm bore of pipe etc complete all as specified and directed 90 S&F PVC (SWR) bends ISI marked any radius of 110 mm borewithaccess door complete all as specified and directed. 91 S&F PVC (SWR) bends ISI marked any radius of 75 mm borewithaccess door complete all as specified and directed. 92 S & F of PVC (SWR) junction single, (Single T) 110 mm bore equal or unequal with acess door complete all as specified and directed. 93 S & F of PVC (SWR) junction single, (Single T) 75 mm bore equal or unequal with acess door complete all as specified and directed. 94 S & F 110mm bore PVC (SWR) vent cowl with rubber ring joints,fixed to pipes all as specified and as directed. 95 Demolition of cement Concrete(unreinforced)in ground floors and pavings n exc 15 cm thickness (below or above ground level) or as in sunken complete all as specified and directed. 96 M & L PCC 1:3:6, type C-2, 50mm thick as in plinth protection, Surface finished fair and smooth without using extra cement complete all as specified and directed. 97 Taking down copper /aluminium point wiring (light, fan, bell, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, light fitting etc.Removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces ofwalls, floors etc complete all as specified and directed. 98 Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch/Busbar including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed. 99 Taking down carefully copper/aluminium Sub main wiring of any size fromsurface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. 100 Taking down ceiling fan/ exhaust fan/Geysers of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan bladesand deposit to MES store yard of AGE E/M complete for refixing. 101 M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts gradeISI-694 marked drawn through in and including heavy duty, PVC casing caping including all accessories after chasing in wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with inner frame suitable for modular switches,including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable with casing caping as surface to match with existing finish complete all as specified and directed for the following :- 102 (a) One light point controlled by one, one way switch 5 Amps 103 (b) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator 104 (c) One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board. 105 (d)One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad. 106 Description all as per item No 5 here in before butusing 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. 107 S & F modular switch piano flushtype, single pole, one way, and 5/6 Amp single module complete all as specified and directed. 108 S & F modular switch piano flush type, single pole, one way, and 15/16 Amp single module complete all as specified and directed. 109 S & F modular socket outlet multipurpose having provision for 3 pin, 5/6 Amp and 2 pin, 5/6 Amp, 2 module piano flush type complete all as specified and directed. 110 S & F modular socket outlet multipurpose having provision for 3 pin, 15/16 Amp and 3 pin, 5/6 Amp, 2 module piano flush type complete all as specified and directed. 111 S & F for Ceiling rose, surface Bakelite with 3 terminals, ISImarked for batten fitting complete all as specified and directed. 112 S & F modular step type fan regulator 120 watt 2 module suitable for 230 volt 50 Hz AC supply complete all as specified and directed. 113 S & Fmodular white cover plate with frame 3 module 114 S & Fmodular white cover plate with frame 6/8 module 115 S & Fmodular metal flush box for 3 module 116 S & Fmodular metal flush box for 6/8 module 117 M & L forSub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable sizeincluding concealed in wall etcone run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit 118 M & L forSub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 10 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty PVC casing caping and its accessaries ISI marked heavy duty of suitable sizeincluding concealed in wall etcone run of PVC insulated with 10 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire complete all as specified and directed. Note:- Two runs of 10 sqmm cable,one run of 10 sqmm cable and one run of PVC conduit will be measured as one unit 119 S & F for sheet metal enclosure MCBDBTPN8 way Vertical type with 200 Amps suitable for MCCB 125 Amps rated bus bar 415 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed. 120 Supply and fix 4 Pole MCCB 100 to 125 Amp, 50 Hz, 415 V with rupturing capacity 35 KA complete all as specified and directed. 121 S & F for sheet metal enclosure MCBDBSPN8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and directed. 122 S & F for MCB Single pole and neutral rated capacity 32 Amps, 240 Volts breaking capacity 10 KA, C curve complete all specified and as directed. 123 S & Ffor MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, C curve complete allspecified and as directed. 124 Re-fixing of ceiling fans complete with blades, down rods, electronic regulator and accessories complete all as specified and as directed. 125 S & F for energy efficient exhaust fan of 250 mm sweep made of plastic body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan forconnection and making suitable size ofhole to existing brick wall for fan basecompelte all as specifiedand directed.(Note : Cost of suitable opening wall for fixing exhaust fan is deemed to be includedin overall rate quoted). 126 Re-fixing of exhaust fan of 250 mm sweep made of plastic/steel body Ventil Air -DS type complete with louver with bolts nuts and washers size of the bolt 15 cm long 12 mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/0.0076 two core from ceiling rose to exhaust fan forconnection and making suitable size ofhole to existing brick wall for fan basecompelte all as specifiedand directed. 127 Re-fixing of geyser of any capacity complete with fast nut and connection pipe for connection complete all as specifiedand directed. 128 S & F for wall mounted LED tube light fitting 20 watts batten for surface mounted, poly coabonate, high transmissitivity diffuser, high lumen ouputboxtype fitting, 230 volts and intregrated electronic driverconnector block etc with warranty option of 5 years from date of installation complete with all accessories internally pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and as directed. . 129 S & F for Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 for security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35 watts with pre wired andnecessary mounting arrangements and provision of 2.5 sq mm three core copper conductor cable multi stranded from ceiling rose to light fitting including necessary dia GI pipe medium grade bracket 1.5 mtr long bend to required shape with clamps, nut, bolts complete all as specified and directed. 130 M & L for earthing complete with galvanized earth plate electrode 600mmx 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvenised earth lead wire of 4 mm dia by means of nuts, bolts, washes of galvanized iron or steel all as shown in electrical plate No 5 and testing on completion including adequate charcoal dust comman salt necessary excavation & earth work PCC(1:3:6) type C-1 pit with precast RCC Cover slab 40 mm thick in PCC(1:2:4) type B-1 reinforced with 6 mm dia MS bars @ 100 mm c/c both ways with funnel wire mesh and 20 mm dia GI pipe medium grade as watering pipe and connected to earthing point complete all as specified and as directed. 131 Supply and laying & testing and commisioning LT underground cable 1100 volts grade, XLPEinsulated and PVC sheathed heavy duty armoured with multi staranded aluminium conductor laid in pipes, trenches/ducts, on poles etc of sizecomplete all as specified and directed and including taking down existing cable any type. 132 (a) 3.5 core x 95 Sqmm 133 Excavation in trenches not exceeding 1.5 mtrs wide & not exceeding 1.5 mtr in depth in soft or loose soil & getting out complete all as per specified & directed. 134 Returning filling including spreading levelling watering & well Ramming in layers not in Exc 25 cm complete all as spfd & directed. 135 Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. 136 M&L for bricks common burnt sub class B designation for protection of cable complete all as specified and directed. 137 M&L for natural local river sand for cable protection. (Note:- Punned thickness of sand shall be measured and paid) 138 Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed at site.
|