Tender For Construction Of Stop Dam Chl Apollo Indore Road Chamber.; 1 Earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means / manual means (exceeding 30cm in depth.) including ramming of bottom, dressing of sides, disposal of excavated earth including of all lift and lead upto 50m. Disposed earth to be levelled and neatly dressed. sor no. 18.2.1/227 2 All kinds of ordinary soil 9.50 x2.60 x0.30 = 7.41 3 Ordinary rock9.50 x2.60 x1.50 = 37.05 4 Providing and laying in position Plain cement concrete (PCC) of specified grade excluding the cost of centering and shutteringCement concrete grade M-20 (Nominal Mix) with 20 mm maximum size of stone aggregate 9.50 x2.60 x0.10 = 2.47sor no. 18.14.3/229 5 Providing and laying in position machine batched and machine mixed , and machine vibrated design mix reinforced cement concrete of M-25 grade mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batch using approved mix design , for reinforced cement concrete work including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement including Admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. Upto Plinth level7 x (2.60 +0.60 )/2 x 4.50 = 50.4Deduction for gate1 nos. x 12.15 = 12.1550.4 - 12.15 = 38.25sor no. 18.16.1/230 6 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding upto floor level including cost of binding wire, wastage and over laps upto 12mm horizontal/ inclined position of reinforcement bars in slab and beams, plinth, chajjas, lintels, upto 4.5m vertical length of reinforcement in wall columns (over laps shall be provided as per requirement of IS : 13920; IS 456 & SP : 34) etc. complete Thermo-Mechanically Treated bars. (Fe 500 D or more) sor no. 18.23.4/231 7 Manufacturing and supply of specials made out of M.S. steel plate or HR coil conforming to IS 3589-2001 or its latest revision/amendment, 5mm to 6mm thick plate in shapes and sizes required as per site conditions including cost of steel plate & other electrical & mechanical material, including Submerged Arc welded, including cost of transportation, loading and unloading complete approved by Engineer-in-Charge. (This is applicable only when standard special are not available).1 nos x (i/c frame) 180 kg = 180 kgsor no. 19.8/241 8 Pumping out to remove the sewers blockage by using suitable pump sets operated by generators, whole assembly mounted on four wheel trailer/ pickup van including diesel and labour charges etcsor no. 17.28.1/222
|