Indian Tenders

Tender Notice

TDR 49295373
Tendering Authority Jodhpur Vidyut Vitaran Nigam Limited
Tender No NIT No. 04/2025-2026
Tender ID 2025_JdVVN_471852_9
Tender Brief Corrigendum : Tender For Construction Of 01 Nos. Of Toilet Block And Other Basic Amenities Under Falna Division. - 1 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (Not Exceeding 1.5 M In Width Or 10
City falna
State Rajasthan
Document Fees INR 590 /-
EMD INR 12400.0 /-
Tender Value INR 6.20 Lakhs /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Tender For Construction Of 01 Nos. Of Toilet Block And Other Basic Amenities Under Falna Division. - 1 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils(B-44/1.8) 2 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size). (B-54/3.1.6) 3 Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). (B-69/6.1.6) 4 Random Rubble stone masonry with hard stone in superstructure aboveplinth level and upto five levelabove 30cm. thick walls in : Cement Mortar 1:6 ( 1-Cement : 6-Sand). Add extra for Wall upto 30cm. and less thickness. (B-69/6.2.6+6.3.4) 5 Supplying and fixing Soorsagar Bhura or Equivalent ashlar sills, lintels and dassa, bearing, bed & top surface made perfenctly even, jambs, skirting steps etc. rough dressed: Upto 15 cm. thick (6.27.1) 6 Supplying and fixing stone lintels/bed plates of approvedquarryroughdressedincement mortar 1:4 : Upto 15 Cm thick (6.18.1) 7 Stone slab roofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both sides in cement sand mortar 1:4,with ceiling pointing in cement sand mortar 1 : 3 complete as per specification and instruction of Engineer In Charge Add extra for subsequent story (10.16.1) 8 Stone slab roofing on ground floor with fine grained stone slab from approved quarry including filling of joints of parapet and slab on both sides in cement sand mortar 1:4,with ceiling pointing in cement sand mortar 1 : 3 complete as per specification and instruction of Engineer In Charge(10.16) 9 Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering.M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). (B-55/3.2.4) 10 Providing & laying broken glazed titles on roof ( broken glazed tilesnot less than 9 Kg/Sqm) on top of hot bitumen @ 1.7 Kg/Sqm. (1.40 Kg ofVG-40 (30/40 )grade and 0.30 Kg/Sqm. OfVG-10 (80/100) grade) and joints filled with cement mortar 1 :2 (1 cement:2 marble dust mixed with water proofing compund all complete as per direction of Engineer-in-charge. (B-109/10.24) 11 Supplying and fixing ashlar stone chhajja 5 to 7 cm. thick all exposed surface fully fine dressed, weather dripped includin 75x75mm. Cement batta (1:2:4) between chhajja & wall (single piece upto 1:2m length) :(A) Red Ashlar one line dressedB- 6.42.3[A] 12 Supplying and fixing in walls machine cut and polished stone shelves, tands andin CM 1:3 with machine cut edges :Kota stone minimum 30mm thick. B-6.17.3 13 Providing and fixing steel glazed window frame made out of 80x40 mm hollow sheet section of 16 gauge thickness, joint mitred weldedand grinded including hold fast of steel lugs 13mm x 3mm and 15 Cm long embedded in C Cblock 15 x 10 x 10 Cm of 1:3:6 nominal concrete and including fixing of pivoted hinges of superior quality, window shutters made out of 50 x 25.0 mm hollow steel section 15 mm paitam of 18 gauge thickness, joint mitred and grinded including 10mm x 10mm square bars welded to framefor paitam fixing float glass 4mm thickpanes with glazing clips and metal sash putty andfixing of shutters frames peg stay, U shape handle 100 mm long, tower bolts 100 mm long of steel powder coated superior quality including fixing and jointing with frame hinges priming coat with steel primer complete in all respect as per direction of Engineer-in –charge Window openable (9.28.1) 14 Supplying and fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20x3mm with suitable screw at not exceeding 150mm distance. (B-102/9.26) 15 Providing and fixing Square bars or other flat welded to window, ventilatiors etc. (B-102/9.27) 16 Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :(A)25mm thick (B-139/12.3.1) 17 (C)6 mm thick cement plaster to ceiling of mix1:3 (1cement : 3-fine sand) (B-139/12.5) 18 Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish :25 mm thick. (B-139/12.2.1) 19 Plaster on new surface on walls in cement sand mortar 1:6 including racking of joint etc. complete fine finish :20mm thick (B-139/12.3.2) 20 Providing & fixing precast cement concrete coping 1:2:4 mix 50 mm thick complete as per specification :--50mm-- (B-56/3.8) 21 Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. (B- /9.5) 22 Providing and fixing external grade board solid core single leaf flush door shutters ISI 2202-67 marked using Phenol formal dehyderesinin glue both sides with approved steel fittings complete as per annexure A: 30 mm thick . Commercial Veneer both side (B-93/8.13.2.1) 23 Kota stone slab flooring 25 mm thick over 20 mm (average) thickbase laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4 coarse sand) For area of each slab from 2001 to 5000 Sq.Cm (B-132/11.18.2) 24 (B) Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete For area of each slab upto 2001Sqcm (B-132/11.19.1) 25 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar)./7.12 26 Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirmingto IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4).7.13 27 White washing with lime to give an even shade including all scafforlding: New work (three or more coats):(12.34.1) 28 Finishing wall with water proofing cement paint of approved brand and manufacture and or required shadetogive an even shade including all scaffolding:New work (Two or more coats applied @ 3.84 kg/10 sqm). 12.41.1 29 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : Two or more coats on new work (B-146/ 12.46.1) 30 Providing and fixing 1mm thick M.S. sheet garrage door shutters with frame of 40 x 40 x 6mm. angle iron 3mm M.S. gusset plates at the junction and corners including all fittings and applying a coat of approved steel primer : (Excluding cost of frames)Using flats 30 x 6mm for diagonal braces and central cross piece./9.12.2 31 A) Half brick masonry in Superstructure , above plinth level upto floor Vlevelusing bricks of designation 75Cement mortar 1 : 6 (1 cement : 6 coarse sand) (B-66/5.8.3) 32 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, making of lines or groove etc complete but excluding the cost of nosing of steps etc. complete. 75mmthickwith20mmthicknominalsizeaggregate. (B-128/11.3.2) 33 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2coarse sand : 4 stone aggregate 10mm and down gauge) includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :(B-109/10.22) 34 Finishing with neat cement (punning). (B-140/12.7) 35 P & F Indian type white glazed vitreous china 1st quality W.C. orissa pan (IS :2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor: Size 580mmx440mm. /1.2.2 36 P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall :Size 510mmx400mm/1.36.2 37 P & F G.I. pipes (Internal Work) with G.I. fittings (IS: 1239 Mark) & MS clamps including cutting and making good the walls and floors:B Class (a) 15 mm dia nominal bore (2.1.1) 38 (b) 25mm dia nominal bore (2.1.3) 39 P & F G.I. pipes (Extranal Work) with G.I. fittings (IS: 1239 Mark) & MS clamps including cutting and making good the walls and floors:B Class (a) 15 mm dia nominal bore (2.2.1) 40 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make:Brass 400 gm,15mm nominal bore./2.7.1 41 P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Wash basin, Gyser etc. C.P. Inlet connection 15mm.Brass (IS : 8931 marked) S-2.12.1 42 P & F 15 mm. Dia Connection Pipe of approved quality/make:PVC pipe with C.P. Brass nuts upto length. 450 mm. (2.13.3) 43 P & F Flush Cock/Flush Valve (IS: 9758 Mark) for WC of approved quality make: Brass / Gun metel Half-turn wt. 1 kg. of approved quality/ make, 25 mm nominal bore (2.14.9) 44 P & F Full-way Value (IS: 778 Mark) or wheet valve of approved make. (A) Gun - metal 25 mm nominal bore.(2.15.3) 45 (B) Gun - metal 15 mm nominal bore.(2.15.1) 46 P & F PVC Storege Tank ISI Marked (IS : 12701) indicating the BIS license No.), of approved make with cover, 25 mm dia 1 M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design:500 ltr. capacity (2.26.3) 47 P & F UPVC SWR. pipes grade B for sciland wast discharge system (IS :13592-1992 marked) of approved makeA) 75 mm dia (3.44.1) 48 B)110mm dia(3.44.2) 49 P & F UPVC SWR. pipes grade B for sciland wast discharge system (IS :13592-1992 marked) of approved make. (A) 110 mm dia vent cowel ( 3.45.30) 50 (B) 110 mm dia Tee with door ( 3.45.17) 51 (C) 110 mm dia bend (3.45.4 ) 52 Construction of manhole in all type of soil inner size 90 X 60 Cm. 300 mm thick masonry in CM 1:6, 10 Cm. thick cement concrete 1:5:10 in foundation, 20 mm thick inside plaster in CM 1:6, finished with floating neat cement, 50mm thick M-15 grade C.C. flooring, making channels, 80mm thick stone slab covering with 40mm thick M-15 grade C.C. flooring, Cement cover with frame of 450mm dia, earthwork etc. complete as per design including disposal of surplus earth within 50 mtr. lead.Depth up to 0.5 M /3.19.1 53 Construction of soakage well in all type of soil 300mm thick dry masonry, top and bottom 300mm course in CM 1:6, 80mm thick stone slab, jointing of slab in CM 1:3, Ralthal, Kharanja, 40mm thick M-15 grade C.C. flooring, earthwork complete as per approved drawing including disposal of earth within a lead of 50 mtr. : Size 240 cm. dia outside & 240 Cm. depth . (3.22.3) 54 Making connection to G I main to Distibution i/c all fitting upto 25 mm dia ( 2.3.1) 55 P&F looking mirror of PVC frame ofappd make ( Atul or eq ) oval shape size 500x400 mm (1.45.1 ) 56 Providing and fixing Towel rail of ring of approved quality/ makeC.P. Brass Towel rail C.P. brass towel rail with bracket 600 x20mm./1.47.4 57 Construction of Cement concrete chamber 125mm dia:Stainless Steel Sheet Grating/3.39.4 58 P & F lst quality WVC Urinal (IS:2556 mark) with 25mm dia G.I. waste pipe, dome waste couplings, concealed iron brackets or screws etc complete.Flat Back (small) size 456x355x265mm. S-1.14.1 59 P&F Marble Urinal Partition slab both sides polished of approved design cut from marble size 900x600mm.Makrana `Adanga` or Raj Nagar 1St Quality White or Andhi Indo-Italian marble.S-1.16.3 60 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR E-1.1 (A) short poing (upt 3 mtr.) (1.1.1) 61 (B) Medium point (Upto 6.0 Mtr.)(1.1.2) 62 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR On board E- 1.3.1 63 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR2 x 2.5 sq. mm. + 1x1.5sqmm E- 4.1.7 64 (B) 2x4.0 sq. mm + 1x 2.5 sq mm ( E-4.1.14) 65 Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular box of 1.2 mm thick with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16 amp. socket outlet (IS:1293) making connection , testing , etc. as required. For specification ofWiring accessories refer ChapterE - 07related item & For additional technical parameters of product / work refer Annexure A attached with this BSR E-7.37 66 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR ,6 A to 32 A rating(E-6.1.1.2) 67 Providing & Fixing of 240/415 V isolatorISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage,true contact i ndication,Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting,minimum phase termination capacity of 35sq.mm.IP 20 contact protection and fitted in existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR Double pole isolator 30 A / 40 A rating(E-6.2.1.1) 68 SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 0.5 HP, 1-Ø, (3 - 18)Mtr, (100-26) LPME- 21.7.1

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 05-06-2025 Corrizendum-1 Date 11-06-2025
2 12-06-2025 Corrizendum-2 Date 18-06-2025
3 19-06-2025 Corrizendum-3 Date 25-06-2025

Key Dates

Publish Date 19-06-2025
Last Date of Bid Submission 25-06-2025
Tender Opening Date 27-06-2025

Contact Information

Company Name Jodhpur Vidyut Vitaran Nigam Limited
Contact Person Superintending Engineer (Civil)
Address New Power House, Jodhpur

Other Detail

Information Source https://eproc.rajasthan.gov.in
Download FileName File Description File Size
Download 98b1a51b-2858-40bd-9df5-1b2d45724c46.html Tender Documents 0 KB
Download BOQ_844465.xls Tender Documents 0 KB
Download TD.pdf Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.