Tender For Construction Of Deficient Md Accommodation At Af Stn Gorakhpur; 1 SCHEDULE A PART I (BUILDING WORKS) 2 Lump sum price worked out by the contractor for Building works as listed in Sch ‘A’ PartI . 3 Sch A Part II (INTERNAL WATER SUPPLY) 4 Lump sum price worked out by the contractor for Internal Water Supply as listed in Sch ‘A’ Part II. 5 Sch A Part III (INTERNAL ELECTRIFICATION) 6 Lump sum price worked out by the contractor for Internal Electrification as listed in Sch ‘A’ Part III . 7 Sch A Part IV (EXTERNAL WATER SUPPLY) 8 Lump sum price worked out by the contractor for External Water Supply as listed in Sch ‘A’ Part IV 9 Sch A Part V (EXTERNAL ELECTRIFICATION) 10 Lump sum price worked out by the contractor for External Electrification as listed in Sch ‘A’ Part V. 11 Sch A Part VI (SEWAGE DISPOSAL) 12 Lump sum price worked out by the contractor for Sewage Disposal as listed in Sch ‘A’ Part VI. 13 Sch A Part VII (AREA DRAINAGE) 14 Lump sum price worked out by the contractor for Area Drainage as listed in Sch ‘A’ Part VII 15 Sch A Part VIII(ROAD/ PATH & CULVERT) 16 Lump sum price worked out by the contractor for Road/Path & Culvert as listed in Sch ‘A’ Part VIII 17 Sch A Part IX (SITE CLEARANCE AND EARTH WORK) 18 Lump sum price worked out by the contractor for Site clearance and Earthwork as listed in Sch ‘A’ Part IX 19 Sch A Part X (COMPOUND WALL ) 20 Lump sum price worked out by the contractor for Compound Wall work as listed in Sch ‘A’ Part X 21 Sch A Part XI (LIGHTENING PROTECTION) 22 Lump sum price worked out by the contractor for Lightening protection work as listed in Sch ‘A’ Part XI 23 Sch A Part XII (Lift Work) 24 Lump sum price worked out by the contractor for Lifts work as listed in Sch ‘A’ Part XII 25 Sch A PartXIII (Miscellaneous Items of B/R and E/M including Lifts, DG Sets etc) 26 S&F Two way bib tap 15 mm bore brass chromium plated fancy types screwed down screwed for iron pipe or for brass ferrule complete all as specified and as directed. 27 S & F 15 mm dia chromium plated brass sink mixer( quarter turn with water saving nozzle with swivel spout ( wall mounted) for mixing hot and cold water , screwed down for 15 mm bore GI pipe completed all as specified and directed. 28 M & L for telephone point wiring with twin core telephone wire complete all as specified and as directed. 29 S&F RJ 11 Tele Jack single with shutter 1 module complete with GI box and front cover complete all as specified and as directed. 30 S&F TV socket Jack single with shutter 1 module complete with GI box and front cover complete all as specified and as directed. 31 Supply, laying, jointing and testing of ductile iron pressure pipe with socket & spigot ends having ISI stamping marking confirming to IS: 8329/2000 in standard length of 5.50-6.00 meter of classification K-7 including rubber tyton jointing material suitable for push on rubber tyton (gasket D-jointing) with cement mortar lining in the pipes having 100 mm bore, including aligning the pipes inside trench as per IS: 12288/1987 and testing the joints with required water pressure complete all as specified & directed.Notes:-(i) Excavation earth works shall be measured and paid separately.(ii) Joints CI/DI specials shall be measured and paid separately.(iii) Joints Material rubber tyton joint and Lead joint etc included in the quoted rate. 32 Supply, laying, jointing and testing of ductile iron pressure pipe with socket & spigot ends having ISI stamping marking confirming to IS: 8329/2000 in standard length of 5.50-6.00 meter of classification K-7 including rubber tyton jointing material suitable for push on rubber tyton (gasket D-jointing) with cement mortar lining in the pipes having 80 mm bore, including aligning the pipes inside trench as per IS: 12288/1987 and testing the joints with required water pressure complete all as specified & directed.Notes:-(i) Excavation earth works shall be measured and paid separately.(ii) Joints CI/DI specials shall be measured and paid separately.(iii) Joints Material rubber tyton joint and Lead joint etc included in the quoted rate. 33 M & L for Ductile iron fitting (any type & any radius/angle) such as bend tee connecting pieces. Double branch (cross collar cap and any type of end reducerY -janction etc completefor pipe upto 150/100/80mm dia normalcomplete as specified and directed. 34 S&F gun metal gate valve with iron head wheel screwed both ends for iron pipe with IS mark of size 80mm bore. 35 S&F gun metal gate valve with iron head wheel screwed both ends for iron pipe with IS mark of size 50mm bore. 36 S&F gun metal gate valve with iron head wheel screwed both ends for iron pipe with IS mark of size 40mm bore. 37 S&F gun metal gate valve with iron head wheel screwed both ends for iron pipe with IS mark of size 25mm bore. 38 M&L for construction of new valve pit chamber of size 1050mm X 1000mm X 1000mm including necessary earth work in any type of soil, PCC foundation (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in base concrete, brick work in CM 1:6 with 10 mm thick platser internally and 15mm thick externally in CM 1:4 upto 15 mm below NGL , 4 mm thick MS cover with hinges and locking arrangements fixed to angle iron frame made out of 40X40X6 mm MS angles, D type handle complete with 2 coat of synthetic enamel paint over one coat of red oxide primer on all metal works and three coat of white wash on all plastetred surfaces of valve chamberscompleteall as specified and directed by engineer in charge . 39 M&L for construction of new valve pit chamber of size 600mm X 600mm X 600mm including necessary earth work in any type of soil , PCC foundation (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in base concrete, brick work in CM 1:6 with 10 mm thick platser internally and 15mm thick externally in CM 1:4 upto 15 mm below NGL , 4 mm thick MS cover with hinges and locking arrangements fixed to angle iron frame made out of 40X40X6 mm MS angles, D type handle complete with 2 coat of synthetic enamel paint over one coat of red oxide primer on all metal works and three coat of white wash on all plastetred surfaces of valve chamberscompleteall as specified and directed by engineer in charge . 40 S&F Thermo plastic (polystrene) cable junction box, having protection class IP-66 and of over all size 155mmx210mmx92mm (Apprx) having metric nockout cables, the cot on the wall, duly fixed with the pole with aluminium strip (25x3mm) clamp, GI bolts, washers and two Nos polymide weather proof cable glands of cable sealing range 10 mm to 17 mm ( complete with check nuts) and including 1 Nos 30 amp 4 way cable connector and 1 Nos 6 amps SP MCB. Note :- During connection the incoming and outgoing cables, the continuty of armour to be maintained by shoting them inside the box and earth continuty to be looped for LED fitting for grounding purpose complete all as spcified and directed. 41 Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (heavy duty) with stranded copper conductor of size 1.5 sqmm, 3 core , 1100 volts grade draw from junction box to street light fitting complete all as specified and as directed. 42 Supply, and Fixing 4 pole MCCB 125 Amps 50 Hz, 415 Volt with rapturing capacity 50 KA. complete all as specified and as directed. 43 Supply, and Fixing 4 pole MCCB 250 Amps 50 Hz, 415 Volt with rapturing capacity 50 KA. complete all as specified and as directed. 44 Supply, installation, testing and commissioning 3 phase and neutral, 415 volts outdoor type, factory made, free standing on MS angle legs, platform mounting, dust and vermin proof cubical type (Double door type) , fully compartmentalized type Meter cabinet for provision and fixing arrangement of 4 Nos three Phase energy meters of made out 2.0 mm thick CRCA sheet with front door having cut out duly covered with transparent polycarbonate/ Glass panel for viewing KWh meter/Timer and other door shall be opaque . All doors should have gasket and locjking arrangement to meet ingress protection level IP-43. The cabinet shall be painted both internally and externally with powder coated paint(RAL 7032 : SEIMENS GREY) after necessary surface treatement and design with 4 Nos of copper bus bar of 500 Amps capacity LT Panel to be fabricated from 2.0 mm thick CRCA MS Sheet with epoixy polyester powder coating paint of shed seimens Grey (RAL-76032), each and s& F the following for Offrs Accn Incoming(a) MCCB 100 Amps, 35 KA. 3 Phase, 4 pole,adjustable type -01 No(b) Ammeter96 mm square digital type with selector switch and CT -01 set(c ) Voltmeter 0-500V -01 No digital type 96 mm square with selector switch- 1 set(d) LED indicator lamp(R-Y-B)- 1 setOutgoing(a) MCB TPN 16 Amps, 16 KA , 3 Phase, 4 pole-05 No (01 Spare)(b)Space for accounting 4 Nos Smart Meter 3 Phase 45 Supply, installation, testing and commissioning 3 phase and neutral, 415 volts outdoor type, factory made, free standing on MS angle legs, platform mounting, dust and vermin proof cubical type (Double door type) , fully compartmentalized design with 4 Nos of copper bus bar of 250 Amps capacity. LT Panel to be fabricated from 3.15 mm thick CRCA MS sheet withepoxy polyester powder coating paint of shade Siemens Grey(RAL-7032),each and supply and fixing the following (for ORs Md Accn MainLT Panel) Incoming(a) MCCB 160 Amps, 35 KA. 3 Phase, 4 pole,adjustable type -01 No(b) Ammeter96 mm square digital type with selector switch and CT -01 set(c ) Voltmeter 0-500V -01 No digital type 96 mm square with selector switch- 1 set(d) LED indicator lamp(R-Y-B)- 1 setOutgoing(a) MCCB63A, 4 pole,415V, 25 KA adjustable type-03 No (b)MCB TPN 16 Amps-01 46 Supply, installation, testing and commissioning 3 phase and neutral, 415 volts outdoor type, factory made, free standing on MS angle legs, platform mounting, dust and vermin proof cubical type (Double door type) , fully compartmentalizedtype meter cabinet for provision and fixing arrangement of 12 Nos energy meter of overall dimension 3600 mm (W)x 750mm (H) x 200mm (D made out 2.0 mm thick CRCA sheet with front door having cut out duly covered with transparent polycarbonate/ Glass panel for viewing KWh meter/Timer and other door shall be opaque . All doors should have gasket and locjking arrangement to meet ingress protection level IP-43. The cabinet shall be painted both internally and externally with powder coated paint(RAL 7032 : SEIMENS GREY) after necessary surface treatement and design with 4 Nos of copper bus bar of 500 Amps capacity LT Panel to be fabricated from 2.0 mm thick CRCA MS Sheet with epoixy polyester powder coating paint of shed seimens Grey (RAL-76032), each and fixing the following (for ORs Md Accn LT Panel-01& 02) Incoming(a) MCCB 100 Amps, 16 KA. 3 Phase, 4 pole,adjustable type -01 No(b) Ammeter96 mm square digital type with selector switch and CT -01 set(c ) Voltmeter 0-500V -01 No digital type 96 mm square with selector switch- 1 set(d) LED indicator lamp(R-Y-B)- 1 setOutgoing(a) MCBSPN 16-25 Amps -12 Nos(b)MCB SP 10 Amps-01 (Stair case Light) (c)Space for accounting 12 Nos Single phase Smart Meter 47 Supply, installation, commissioning & testing of Silent diesel engine driven generating set complete with acoustic enclosure, antivibration pads with 75db noise level at 1 mtr distance fromDG set and control system for 40 KVA output at NTP, AC 415 volts, 50 C/S, 3 phase 4 wire directly coupled completewith self startingsystem includingaccessories equipment control panel etc as detailed below:-(a) Alternator:- Alternator 40 KVAoutput at 0.80 PF lag 50 Hz, AC 3 phase, 4 wire 415 volts.The alternator shall be self excited ,self regulated,screen procted ,mountain on rigid frame MS sheet channel base frame of IS B364:IS 4722,BS5000,IEC:34 andbrush-less type shall be suitable for tropical climate and IP23 protection with Class H insulation and temperature rise limited to class H insulation limit and permissible overload of 10% for one hour in 12 hours of operation all as specified and directed.(b) Diesel Engine :- Diesel engine of Adequate BHP , watercooled and electric start suitable to drive above alternatorindependently, coupled directly through flexiblecoupling, multicylinder , 1500 RPM industrial typeas perBS-649 or IS-1601 withgovernorsuitableto regulatespeed of DG set from No load to full load completewith fuel tank of cap as per manufactrer recommendations, fuel lines, exhaust pipe extendedupto and outside building duly insulated with asbestosrope and with support and silencer muffles etc forcontinuous operation and standard accessories, sump, pre heaters, Fuel tank of capacity for 12 hours running of DG set with stop cock, drainplug and necessaryfuel pipe, manufactured out of 2mm thick MS sheet, etc all as specified and directed. (c)Control panel :- The AMF control panel consistingof control cubicalfabricated sheet steel construction indoor type suitablefor mounting accessories, static energy meter with LED display, digital power factormeter, Digital frequencymeter & Digital RPM meter, digital voltmeter 0-500 volts with inbuilt selector switch digital ammeter, CTs operated of suitable rating with inbuilt selector switch, indicator lamps LED type,hoursmeter, low oil pressure indication, over speed indication and high water temperature indicator. 48 (d) Electric starter equipment :- The equipment witll comprise the following:- (i) Maint free Battery duly initial charged as recommended by manufacture & Battery lead of adequate capacity. (ii) Starter motor(iii) Starter gearing (iv) Start/stop push button (v) Alternator/Dynamo of suitable capacity to chargethe batteries while DG set is running completewith auto cut all as permanufacturers recommendations.(vi) PCC foundation forDG set all as permanufacturers recommendation or requiredat site ordirectedby Engineer-in-Charge. DG Setacoustic canopy shall be fromOEM.(e) Auto mains failure panel 415 volts 50 HZ suitablefor 40 KVA Gen set, madeout of 16 gauge MS sheet cubical type floor mounted front and rear door open able with locking arrangment duly powder coatedsuitable for and including the following :-(i) Microprocessorbased electronic controlbox for automatic switching ON & OFF of DG set and transfer of load equipped with microprocessor based controller 100% auto, 50% automanual and 100% by passarrangmentadjustabletime delay to engine start, standard setting 3 secondadjustable 0-10 seconds, adjustable time delay on tansferto normal0-30 minutestime delay (adjustable) to engine cool down 0-5 minutes, adjustable time delay on transfer to emergency 0 -15 sec As Per Manufacturer Recomendatation (ii) Heavy duty air break contractor 4 pole 415 volts, 86 A, 50 Hz, AC supply system with dustover andoperating coil voltage 230V with 2 NO 2 NC aux contracts all as required for safe operation under over voltage. 49 (iii) Voltmeter 0-500 volts, digitaltype with selectorswitch suitable for 40 KVA DG Set(iv) Ammeter 0-400 amps CTs operated digital type with selector switch and CTs of appropriate ratio suitable for 40 KVA DG Set.(v) Digital frenquencymeter for frequency range 30 to 55 Hz with builtin transducer suitable for 40 KVA DG Set(vi)Digital powerfactormeterbuilt in transducersuitable for 40 KVA DG Set (vii) Indicator lamp LED type 230 volts for Gen/mains supplyON/OFF indication and differentrelay position etc all as required and recommended by manufacturer.(viii) Bakelite fuse base carrier with HRC fuses suitable for 40KVA DG Set, 415 volts suitable for andincluding knife typeHBC fuse link-06 Nos.(ix)DC operated relays as required for remote operation, fault indication and out switching OFF incase of faultin DG set.Note :- (a) The AMF panel shall be integrated with respective LT distribution panel and all electrical connections shall be carried out as per site requirement..(b) The testingof DG set for continuous 12 Hrs running shall be carried by officer detailed by acceptingofficerbeforeissuing completion certificateto contractor. On load testing equipment includingdiesel forcontinuous testingfor 12 hoursor abovetill full testing (satisfaction ordirected by Engr-in-Charge) will be arranged by thecontractor.(c) The rate for DG Set foundation as per manufacturer recommondation should deemed to be included in quoted rates.(d) DG Set should comprising Latest CPCB Norms issued by Govt of india. 50 M&L for Earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx 6mm thick buried direcly in ground vertically to a depth not less than 2.25 meters below normal ground lev el with the top edge of earth plate not less than 1.5 meters below ground level connected to galvanized iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel all as shown in electrical plate No.5 of SSR part I and earth wire protected by galvanized pipe light grade 40mm bore and thorugh test point including necessary earth work and excavation in any type of strata, GI light grade 20mm bore watering pipe with funnel and wire mesh, PCC 1:2:4 type B1 chember with 40mm thick RCC 1:2:4 type B1 design mix cover slab with 6mm kdia MS bars at 100mm c/c both ways with MS Hook 6mm dia MS bars etc complete all as specified and directed and testing on completion. 51 Design supply, install testing & commissioning passengers lift for 13 passenger (884 Kg), speed 1.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS-14665, suitable to serve S + 03 upper floors with AC Variable Voltage & Variable Frequency drive (VVVF drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) , complete all as specified and directed.Note:-Overall quoted rates incl of all consumables and minor parts Annual maintenance contract (AMC) during the defect liability period of two year. Necessary MoU shall be submitted by rhe contractor duly signed by the OEM of AMC and further maintenance. 52 M&L Earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, burried directly in to ground ( earth pit) not less than 2.25 metres deep below GL with top edge of earth plate ot less athn 1.50 m below ground levelsurrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, connected to copper strip 20x3 mm(7.50 m Long) by means of nuts, bolts and washers, checknuts of GIand protected by the GI pipe light grade 15 mm nominal bore(7.5 m long) for earth lead wire and watering pipe light grade of 20 mm nominal bore, 0.63 mm thick G I sheet funnel , wiremesh, earthing test pointetc complete including necessary earth work and excavation in any type of soil , PCC 1:2:4 type B1 earth pit and Precast RCC cover 65 mm thick duly reinforced with 6 mm dia. MS round bars @ 100mm C/C both ways,with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as describedin electric plate of SI Part I completeall as specified and directed and testing on completion. Note :- Ifthe desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
|