Indian Tenders

Tender Notice

TDR 49097032
Tendering Authority Rabindranath Tagore Medical College
Tender No 6
Tender ID 2025_RNTMC_466436_1
Tender Brief Corrigendum : Tender For Rate Contract Of Pacemaker And Electrophysiological Study Related Cardiac Items
City udaipur
State Rajasthan
Document Fees INR 2000 /-
EMD INR 800000.0 /-
Tender Value INR 4 Crore /-
Tender Type Tender
Bidding Type Open Tender
Competition Type Indian

Tender Details

Rate Contract Of Pacemaker And Electrophysiological Study Related Cardiac Items , Rate Contract Of Pacemaker And Electro Physiological Study Related Cardiac Items:- , Single Chamber Pacemaker (Vvir) With Peel Away Sheath Fr. • Screw In And Tined Lead As Per Operator’S Preference •Life Long Battery Warranty • Auto Capture Mode •Minimize Ventricular Pacing Mode • Hysteresis Mode • Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With Fr. Peel Away Sheath • 3.0 T Mri Compatible (Full Body) • Usfda/Pmda Approved , Single Chamber Pacemaker (Vvir) With Peel Away Sheath Fr. • Screw In And Tined Lead As Per Operator’S Preference •Life Long Battery Warranty • Auto Capture Mode •Minimize Ventricular Pacing Mode • Hysteresis Mode • Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With Fr. Peel Away Sheath • 3.0 T Mri Compatible (Full Body) • Ceapproved , Single Chamber Pacemaker (Vvir) With Peel Away Sheath Fr. • Screw In And Tined Lead As Per Operator’S Preference •Life Long Battery Warranty • Auto Capture Mode •Minimize Ventricular Pacing Mode • Hysteresis Mode • Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With Fr. Peel Away Sheath • 3.0 T Mri Compatible (Full Body) • Dcgiapproved , Single Chamber Pacemaker (Vvir) With Peel Away Sheath Fr. • Screw In And Tined Lead As Per Operator’S Preference •Auto Capture Mode •Minimize Ventricular Pacing Mode • Hysteresis Mode • Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With Fr. Peel Away Sheath • 1.5T And Abovemri Compatible (Full Body) • Usfda/Pmda Approved , Single Chamber Pacemaker (Vvir) With Peel Away Sheath Fr. • Screw In And Tined Lead As Per Operator’S Preference •Auto Capture Mode •Minimize Ventricular Pacing Mode • Hysteresis Mode • Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With Fr. Peel Away Sheath • 1.5 T And Abovemri Compatible (Full Body) • Ce Approved , Single Chamber Pacemaker (Vvir) With Peel Away Sheath Fr. • Screw In And Tined Lead As Per Operator’S Preference •Auto Capture Mode •Minimize Ventricular Pacing Mode • Hysteresis Mode • Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With Fr. Peel Away Sheath • 1.5 T And Abovemri Compatible (Full Body) • Dcgi Approved , Dual Chamber Pacemaker (Ddd) With Peel Away Sheath Fr. • Screw In And Tined Lead As Per Operator’S Preference • Life Long Battery Warranty • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With Fr.Peel Away Sheath • 3.0 T Mri Compatible (Full Body) • Usfda/Pmda Approved , Dual Chamber Pacemaker (Ddd) With Peel Away Sheath Fr. • Screw In And Tined Lead As Per Operator’S Preference •Life Long Battery Warranty • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With Fr.Peel Away Sheath • 3.0 T Mri Compatible (Full Body) • Ce- Approved , Dual Chamber Pacemaker (Ddd) With Peel Away Sheath Fr. • Screw In And Tined Lead As Per Operator’S Preference •Life Long Battery Warranty • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With Fr.Peel Away Sheath • 3.0 T Mri Compatible (Full Body) • Dcgi -Approved , Dual Chamber Pacemaker (Ddd) With Peel Away Sheath Fr. • Screw In And Tined Lead As Per Operator’S Preference • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With Fr.Peel Away Sheath • 1.5 T And Above Mri Compatible (Full Body) • Usfda/Pmda - Approved , Dual Chamber Pacemaker (Ddd) With Peel Away Sheath Fr. • Screw In And Tined Lead As Per Operator’S Preference • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With Fr.Peel Away Sheath • 1.5 T And Above Mri Compatible (Full Body) • Ce - Approved , Dual Chamber Pacemaker (Ddd) With Peel Away Sheath Fr. • Screw In And Tined Lead As Per Operator’S Preference • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With Fr.Peel Away Sheath • 1.5 T And Above Mri Compatible (Full Body) • Dcgi- Approved , Dual Chamber Pacemaker (Dddr) With Peel Away Sheath Fr. • Screw In And Tined Lead As Per Operator’S Preference • Life Long Battery Warranty • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With Fr.Peel Away Sheath • 3.0 T Mri Compatible (Full Body) • Usfda/Pmda-Approved , Dual Chamber Pacemaker (Dddr) With Peel Away Sheath Fr. • Screw In And Tined Lead As Per Operator’S Preference • Life Long Battery Warranty • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With Fr.Peel Away Sheath • 3.0 T Mri Compatible (Full Body) • Ce -Approved , Dual Chamber Pacemaker (Dddr) With Peel Away Sheath Fr. • Screw In And Tined Lead As Per Operator’S Preference • Life Long Battery Warranty • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With Fr.Peel Away Sheath • 3.0 T Mri Compatible (Full Body) • Dcgi -Approved , Dual Chamber Pacemaker (Dddr) With Peel Away Sheath Fr. • Screw In And Tined Lead As Per Operator’S Preference • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With Fr.Peel Away Sheath • 1.5 T And Abovemri Compatible (Full Body) • Usfda/Pmda-Approved , Dual Chamber Pacemaker (Dddr) With Peel Away Sheath Fr. • Screw In And Tined Lead As Per Operator’S Preference • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With Fr.Peel Away Sheath • 1.5 T And Above Mri Compatible (Full Body) • Ce-Approved , Dual Chamber Pacemaker (Dddr) With Peel Away Sheath Fr. • Screw In And Tined Lead As Per Operator’S Preference • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With Fr.Peel Away Sheath • 1.5 T And Above Mri Compatible (Full Body) • Dcgi-Approved , Single Chamber Icd Set • Should Be Supplied With 7.0To7. Fr. Defibrillator Lead Shouldbe Compatible With 8 Fr. Peel Away Sheath • Small Size Below 35Cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends With Alerts • 40J Delivered Energy With Programmable Tilt And Pulse Width Programming • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Overspending • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert • Facility Of Speciallycoated Device For Avoiding Lead Abrasion • Proactive Measurement Of St Segment Changes With Alerts • Usfda/Pmda Approved , Single Chamber Icd Set • Should Be Supplied With 7.0To7. Fr. Defibrillator Lead Shouldbe Compatible With 8 Fr. Peel Away Sheath • Small Size Below 35Cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends With Alerts • 40J Delivered Energy With Programmable Tilt And Pulse Width Programming • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Overspending • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert • Facility Of Speciallycoated Device For Avoiding Lead Abrasion • Proactive Measurement Of St Segment Changes With Alerts • Ce-Approved , Single Chamber Icd Set • Should Be Supplied With 7.0To7. Fr. Defibrillator Lead Shouldbe Compatible With 8 Fr. Peel Away Sheath • Small Size Below 35Cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends With Alerts • 40J Delivered Energy With Programmable Tilt And Pulse Width Programming • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Overspending • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert • Facility Of Speciallycoated Device For Avoiding Lead Abrasion • Proactive Measurement Of St Segment Changes With Alerts • Dcgi-Approved , Dual Chamber Icd Set • Should Be Supplied With 7.0 To 7. Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Lead Profile: Should Be Maximum Up To 5 .8 Fr. And Lead Should Be Compatible With Fr.Peel Away Sheath • Small Size Below 35Cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • 40J Delivered Energy With Programmable Tilt And Pulse Width Programming. • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert • Proactive Measurement Of St Segment Changes With Alerts • Facility Of Specially Coated Device For Avoiding Lead Abrasion (Optional) • Usfda/Pmda Approved , Dual Chamber Icd Set • Should Be Supplied With 7.0 To 7. Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Lead Profile: Should Be Maximum Up To 5 .8 Fr. And Lead Should Be Compatible With Fr.Peel Away Sheath • Small Size Below 35Cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • 40J Delivered Energy With Programmable Tilt And Pulse Width Programming. • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert • Proactive Measurement Of St Segment Changes With Alerts • Facility Of Specially Coated Device For Avoiding Lead Abrasion (Optional) • Ce- Approved , Dual Chamber Icd Set • Should Be Supplied With 7.0 To 7. Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Lead Profile: Should Be Maximum Up To 5 .8 Fr. And Lead Should Be Compatible With Fr.Peel Away Sheath • Small Size Below 35Cc • Warranty : Minimum 8 Years • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • 40J Delivered Energy With Programmable Tilt And Pulse Width Programming. • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Patient Alert • Proactive Measurement Of St Segment Changes With Alerts • Facility Of Specially Coated Device For Avoiding Lead Abrasion (Optional) • Dcgi - Approved , Cardiac Resynchronization Pacemaker With All Accessories - Ra, Rv And Quadripolar Lv Leads And Catheterscrt-P • Lv Lead-Upto 5 Fr. • Rv Lead Up To 5.8 Fr. And Compatible With Fr. Sheath • Atrial Leadup To 5.8 Fr. And Compatible With Fr. Sheath • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • Electrocardiogram Based Av Optimization For Suggesting Optimized Av Delays • Warranty : Minimum 5 Years On Device • Special Algorithms To Predict Lead Failure And Protection Inappropriate Shocks During Failed Lead • Programmable At/Af Alerts With Af Burden Trending • Facility Of Specially Coated Device For Avoiding Lead Abrasion(Optional) • Special Trigger Mode Biventricular Pacing In Presence Of At/Af • Facility Of Rf Telemetry • Should Be Supplied With Compatible Leads And Introducers For Ra & Rv • Lv Lead Delivery Systems Should Be Compatible With 7 Fr. Ep Catheters Optional • Usfda /Pmda Approved , Cardiac Resynchronization Pacemaker With All Accessories - Ra, Rv And Quadripolar Lv Leads And Catheterscrt-P • Lv Lead-Upto 5 Fr. • Rv Lead Up To 5.8 Fr. And Compatible With Fr. Sheath • Atrial Leadup To 5.8 Fr. And Compatible With Fr. Sheath • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • Electrocardiogram Based Av Optimization For Suggesting Optimized Av Delays • Warranty : Minimum 5 Years On Device • Special Algorithms To Predict Lead Failure And Protection Inappropriate Shocks During Failed Lead • Programmable At/Af Alerts With Af Burden Trending • Facility Of Specially Coated Device For Avoiding Lead Abrasion(Optional) • Special Trigger Mode Biventricular Pacing In Presence Of At/Af • Facility Of Rf Telemetry • Should Be Supplied With Compatible Leads And Introducers For Ra & Rv • Lv Lead Delivery Systems Should Be Compatible With 7 Fr. Ep Catheters Optional , Cardiac Resynchronization Pacemaker With All Accessories - Ra, Rv And Quadripolar Lv Leads And Catheterscrt-P • Lv Lead-Upto 5 Fr. • Rv Lead Up To 5.8 Fr. And Compatible With Fr. Sheath • Atrial Leadup To 5.8 Fr. And Compatible With Fr. Sheath • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • Electrocardiogram Based Av Optimization For Suggesting Optimized Av Delays • Warranty : Minimum 5 Years On Device • Special Algorithms To Predict Lead Failure And Protection Inappropriate Shocks During Failed Lead • Programmable At/Af Alerts With Af Burden Trending • Facility Of Specially Coated Device For Avoiding Lead Abrasion(Optional) • Special Trigger Mode Biventricular Pacing In Presence Of At/Af • Facility Of Rf Telemetry • Should Be Supplied With Compatible Leads And Introducers For Ra & Rv • Lv Lead Delivery Systems Should Be Compatible With 7 Fr. Ep Catheters Optional • Dcgi - Approved , Cardiac Resynchronization Defibrillator With With All Accessories - Ra, Rv And Quadripolar Lv Leads And Catheters Crt-D • Lv Lead-Upto 5 Fr. • Rv Defibrillator Lead : Should Be Supplied Up To 7. Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Leadup To 5.8 Fr. And Compatible With Fr. Sheath • 40J Delivered Energy • Pulse Width And Tilt : Programmable As Per Dft • Heart Failure Congestion Monitoring Trends With Alerts • Small Size Below 35Cc • Warranty : Minimum 5 Years • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing (Optional) • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Vibratory Patient Alert Optional • Facility Of Specially Coated Device For Avoiding Lead Abrasion (Optional) • Usfda /Pmda Approved , Cardiac Resynchronization Defibrillator With With All Accessories - Ra, Rv And Quadripolar Lv Leads And Catheters Crt-D • Lv Lead-Upto 5 Fr. • Rv Defibrillator Lead : Should Be Supplied Up To 7. Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Leadup To 5.8 Fr. And Compatible With Fr. Sheath • 40J Delivered Energy • Pulse Width And Tilt : Programmable As Per Dft • Heart Failure Congestion Monitoring Trends With Alerts • Small Size Below 35Cc • Warranty : Minimum 5 Years • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing (Optional) • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Vibratory Patient Alert Optional • Facility Of Specially Coated Device For Avoiding Lead Abrasion (Optional) • Ce - Approved , Cardiac Resynchronization Defibrillator With With All Accessories - Ra, Rv And Quadripolar Lv Leads And Catheters Crt-D • Lv Lead-Upto 5 Fr. • Rv Defibrillator Lead : Should Be Supplied Up To 7. Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Leadup To 5.8 Fr. And Compatible With Fr. Sheath • 40J Delivered Energy • Pulse Width And Tilt : Programmable As Per Dft • Heart Failure Congestion Monitoring Trends With Alerts • Small Size Below 35Cc • Warranty : Minimum 5 Years • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing (Optional) • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Vibratory Patient Alert Optional • Facility Of Specially Coated Device For Avoiding Lead Abrasion (Optional) • Dcgi - Approved , Dual Chamber Pacemaker (Dddr) With Peel Away Sheath Fr. –With Conduction System Pacing (Csp) • Screw In And Tined Lead As Per Operator’S Wish •Life Long Battery Warranty. • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With Fr.Peel Away Sheath • 3.0 T Mri Compatible (Full Body) • Usfda/Pmda-Approved , Dual Chamber Pacemaker (Dddr) With Peel Away Sheath Fr. –With Conduction System Pacing (Csp) • Screw In And Tined Lead As Per Operator’S Wish •Life Long Battery Warranty. • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With Fr.Peel Away Sheath • 3.0 T Mri Compatible (Full Body) • Ce-Approved , Dual Chamber Pacemaker (Dddr) With Peel Away Sheath Fr. –With Conduction System Pacing (Csp) • Screw In And Tined Lead As Per Operator’S Wish •Life Long Battery Warranty. • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With Fr.Peel Away Sheath • 3.0 T Mri Compatible (Full Body) • Dcgi-Approved , Dual Chamber Pacemaker (Dddr) With Peel Away Sheath Fr. –With Conduction System Pacing (Csp) • Screw In And Tined Lead As Per Operator’S Wish • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With Fr.Peel Away Sheath • 1.5 Tand Above Mri Compatible (Full Body) Usfda/Pmda-Approved , Dual Chamber Pacemaker (Dddr) With Peel Away Sheath Fr. –With Conduction System Pacing (Csp) • Screw In And Tined Lead As Per Operator’S Wish • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With Fr.Peel Away Sheath • 1.5 T And Above Mri Compatible (Full Body) Ce -Approved , Dual Chamber Pacemaker (Dddr) With Peel Away Sheath Fr. –With Conduction System Pacing (Csp) • Screw In And Tined Lead As Per Operator’S Wish • Auto Capture Mode •Minimize Ventricular Pacing Mode • Beat To Beat Capture Mechanism • Af Suppression • Optimization Of Av Delay •Pacemaker Lead Profile Should Be Maximum Up To 5 .8 Fr. • Lead Should Be Compatible With Fr.Peel Away Sheath • 1.5 T And Above Mri Compatible (Full Body) , Crt-P With Conduction System Pacing(Csp) – With All Accessories Crt-P With All Accessories - Ra, Rv And Quadripolar Lv Leads And Catheterscrt-P • Lv Lead-Upto 5 Fr. • Rv Lead Up To 5.8 Fr. And Compatible With Fr. Sheath • Atrial Leadup To 5.8 Fr. And Compatible With Fr. Sheath • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • Electrocardiogram Based Av Optimization For Suggesting Optimized Av Delays • Warranty : Minimum 5 Years On Device • Special Algorithms To Predict Lead Failure And Protection Inappropriate Shocks During Failed Lead • Programmable At/Af Alerts With Af Burden Trending • Facility Of Specially Coated Device For Avoiding Lead Abrasion(Optional) • Special Trigger Mode Biventricular Pacing In Presence Of At/Af • Facility Of Rf Telemetry • Should Be Supplied With Compatible Leads And Introducers For Ra & Rv • Lv Lead Delivery Systems Should Be Compatible With 7 Fr. Ep Catheters Optional • Usfda /Pmda Approved , Crt-P With Conduction System Pacing(Csp) – With All Accessories Crt-Pwith All Accessories - Ra, Rv And Quadripolar Lv Leads And Catheterscrt-P • Lv Lead-Upto 5 Fr. • Rv Lead Up To 5.8 Fr. And Compatible With Fr. Sheath • Atrial Leadup To 5.8 Fr. And Compatible With Fr. Sheath • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • Electrocardiogram Based Av Optimization For Suggesting Optimized Av Delays • Warranty : Minimum 5 Years On Device • Special Algorithms To Predict Lead Failure And Protection Inappropriate Shocks During Failed Lead • Programmable At/Af Alerts With Af Burden Trending • Facility Of Specially Coated Device For Avoiding Lead Abrasion(Optional) • Special Trigger Mode Biventricular Pacing In Presence Of At/Af • Facility Of Rf Telemetry • Should Be Supplied With Compatible Leads And Introducers For Ra & Rv • Lv Lead Delivery Systems Should Be Compatible With 7 Fr. Ep Catheters Optional • Ce- Approved , Crt-P With Conduction System Pacing(Csp) – With All Accessories Crt-Pwith All Accessories - Ra, Rv And Quadripolar Lv Leads And Catheterscrt-P • Lv Lead-Upto 5 Fr. • Rv Lead Up To 5.8 Fr. And Compatible With Fr. Sheath • Atrial Leadup To 5.8 Fr. And Compatible With Fr. Sheath • Heart Failure Congestion Monitoring Trends With Alerts • Facility For Overdriving Atrium For Prevention Of Atrial Arrythmias • Electrocardiogram Based Av Optimization For Suggesting Optimized Av Delays • Warranty : Minimum 5 Years On Device • Special Algorithms To Predict Lead Failure And Protection Inappropriate Shocks During Failed Lead • Programmable At/Af Alerts With Af Burden Trending • Facility Of Specially Coated Device For Avoiding Lead Abrasion(Optional) • Special Trigger Mode Biventricular Pacing In Presence Of At/Af • Facility Of Rf Telemetry • Should Be Supplied With Compatible Leads And Introducers For Ra & Rv • Lv Lead Delivery Systems Should Be Compatible With 7 Fr. Ep Catheters Optional • Dcgi- Approved , Crt-D With Conduction System Pacing(Csp) – With All Accessories Crt-Dwith With All Accessories - Ra, Rv And Quadripolar Lv Leads And Catheters Crt-D • Lv Lead-Upto 5 Fr. • Rv Defibrillator Lead : Should Be Supplied Up To 7. Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Leadup To 5.8 Fr. And Compatible With Fr. Sheath • 40J Delivered Energy • Pulse Width And Tilt : Programmable As Per Dft • Heart Failure Congestion Monitoring Trends With Alerts • Small Size Below 35Cc • Warranty : Minimum 5 Years • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing (Optional) • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Vibratory Patient Alert Optional • Facility Of Specially Coated Device For Avoiding Lead Abrasion (Optional) • Usfda/Pmda- Approved , Crt-D With Conduction System Pacing(Csp) – With All Accessories Crt-D With With All Accessories - Ra, Rv And Quadripolar Lv Leads And Catheters Crt-D • Lv Lead-Upto 5 Fr. • Rv Defibrillator Lead : Should Be Supplied Up To 7. Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Leadup To 5.8 Fr. And Compatible With Fr. Sheath • 40J Delivered Energy • Pulse Width And Tilt : Programmable As Per Dft • Heart Failure Congestion Monitoring Trends With Alerts • Small Size Below 35Cc • Warranty : Minimum 5 Years • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing (Optional) • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Vibratory Patient Alert Optional • Facility Of Specially Coated Device For Avoiding Lead Abrasion (Optional) • Ce- Approved , Crt-D With Conduction System Pacing(Csp) – With All Accessories Crt-D With With All Accessories - Ra, Rv And Quadripolar Lv Leads And Catheters Crt-D • Lv Lead-Upto 5 Fr. • Rv Defibrillator Lead : Should Be Supplied Up To 7. Fr. Defibrillator Lead Compatible With 8 Fr. Peel Away Sheath • Atrial Leadup To 5.8 Fr. And Compatible With Fr. Sheath • 40J Delivered Energy • Pulse Width And Tilt : Programmable As Per Dft • Heart Failure Congestion Monitoring Trends With Alerts • Small Size Below 35Cc • Warranty : Minimum 5 Years • Facility Of Changing The Shocking Vector Based On Over Current Sensing • Special Sensing Filter Protection For T Wave Over Sensing (Optional) • Special Algorithms To Predict Lead Failure And Protection From Inappropriate Shocks During Failed Lead With Vibratory Patient Alert Optional • Facility Of Specially Coated Device For Avoiding Lead Abrasion (Optional) • Dcgi - Approved , Pacemaker Lead With Peel Away Sheath Only (Without Pulse Generator) For The Existing Company Providing Complete Pacemaker At Rnt Medical College • Usfda /Pmda - Approved , Pacemaker Lead With Peel Away Sheath Only (Without Pulse Generator) For The Existing Company Providing Complete Pacemaker At Rnt Medical College • Ce - Approved , Pacemaker Lead With Peel Away Sheath Only (Without Pulse Generator) For The Existing Company Providing Complete Pacemaker At Rnt Medical College • Dcgi - Approved , Long Sheaths/Introducers- Prefaced Valved Long Sheaths For Rfa With Mullins Curve, Multipurpose Curve, Other Curves, 7F To 9F, Atleast 80- Cm Long, 0.038 Wire Compatible , Long Sheaths/Introducers- Brite Tip Intervention Sheaths With Tip Visualization, Kink Resistant, Cold Shapable With Silicon Coating , Long Sheaths/Introducers- Brite Tip Intervention Sheaths With Tip Visualization, Kink Resistant, Cold Shapable With Silicon Coating , Long Sheaths/Introducers- Long Sheaths (Peel Away, Slittable, With Breaking Valve) For Special Applications Like Coronary Sinus Intubation, Lateral Vein, Special Curves Like Renal, Hook Shape Etc , Long Sheaths/Introducers- Peel Away Introducer Sheaths With Break Away Hwmostatic Valves For Pacing Leads, 5F-12Cm, Optional Infusion Side Port, Radio-Opaque Distal Tip And Multiple Curves , Pacing Lead Stablizers- , Surface Patch For 3 D Mapping – (Adult & Pediatric) , Long Sheaths/Introducers- Prefaced Valved Long Sheaths For Rfa With Mullins Curve, Multipurpose Curve, Other Curves, 7F To 9F, Atleast 80- Cm Long, 0.038 Wire Compatible , Long Sheaths/Introducers- Brite Tip Intervention Sheaths With Tip Visualization, Kink Resistant, Cold Shapable With Silicon Coating , Long Sheaths/Introducers- Introducer Sheaths For Electrophysiology, With Various Swartz Curves Sl 0-4, Sr 0-4, 8F, 8.5F , 9F , Balloon Catheter For Non-Contact 3 D Mapping , Diagnostic Ep Catheters- The Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design (Electrode Size, Electrode Distance, Electrode Material) Etc. It Will Be Easier If The Common Catheters Use Like F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes/Platinum, Palladiumelectrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. All Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Configurations Would Be Pole, French. Curve Of Catheter, Electrode Configuration, Fixed / Deflectable , Woven Ep Diagnostic Catheters – (Woven Material With Braided Conducting Wire, Ensuring Prolonged Stability) The Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design (Electrode Size, Electrode Distance, Electrode Material) Etc. It Will Be Easier If The Common Catheters Use Like F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes/Platinum, Palladiumelectrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. All Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Quadripolar, 5-7, Josephson, 2-5-2-5, Fixed , Cables For Ep & Rfa – The Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design (Electrode Size, Electrode Distance, Electrode Material) Etc. It Will Be Easier If The Common Catheters Use Like F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes/Platinum, Palladiumelectrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. All Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Quadripolar Cable, Compatible With Quardripolar Catheter , Cables For Ep & Rfa – The Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design (Electrode Size, Electrode Distance, Electrode Material) Etc. It Will Be Easier If The Common Catheters Use Like F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes/Platinum, Palladiumelectrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. All Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Decapolar Cable, Compatiblewith Decapolar Catheter , Cables For Ep & Rfa – The Vendor Should Quote For Each Catheter Separately If Prices Differ Based Upon French Size, Curve, Electrode Catheter Design (Electrode Size, Electrode Distance, Electrode Material) Etc. It Will Be Easier If The Common Catheters Use Like F, Josephson Curve, Electrode Configuration 2-5-2-5, Stainless Steel Electrodes/Platinum, Palladiumelectrodes Are Specified First. All Cable Should Be Quoted Separately. Cost Mentioned For Each Item Will Be Compared Based On The Catheter And Cable. All Items Should Be Compatible With Ep Tracer System Installed At Rnt Medical College, Udaipur Hexapolar Cable, Compatiblewith Hexapolar Catheter , Bi-Directional Steerable Catheters Handle- Thumb Wheel Or Push Pull Automatic Curve Lock Mechanism Electrode – Stainless Steel, Platinum, Palladium Quality Approval – - Description Size(Fr) Electrode Spacing(Mm) Curve, Small, Large 4.0 , Dual Curve Rf Ablation Catheter Bi-Directional Steerable Electrode – Stainless Steel, Platinum, Palladium Quality Approval – - Description Size(Fr)7.8 Fr Electrode Spacing(Mm) 2-5-2 Mm Curve,Medium,,Large,,Extra Large , Ablation Catheters (Items 1-10) - (All Sizes 4F To 8.5F, All Curves A-K, 270, All Electrode Sizes And Spacing, E.G.) (All Itemss Differing In Make/Prices Need To Be Mentioned Seperately. Quote Separately If Different In Terms Of Material, Braiding, Electrode Material Platinum, Palladiumor Stainless Steel Etc) Quote With Appropriate Connector To Existing Ept 1000 And Stockert Ablators. Ept 1000 Is Not Compatible With Thermocouple And Appropriate Catheters/ Connectors Should Be Quoted. Thermistor Catheters Would Therefore By Preferred. In Addition Give Prices Of All Connector Cables / Accessories Seperately. All Items Should Be Compatiblewith Existing Ep Tracer Machine In Rnt Medical College, Udaipur Type Ablation Catheter Regular Tip Size 4 Mm Diameter -8Fcurves/Reach All (Equivalent To A-F, J, K, 270) Comments , Balloon Catheter For Non-Contact 3 D Mapping , Ablation Catheters (Items 1-10) - (All Sizes 4F To 8.5F, All Curves A-K, 270, All Electrode Sizes And Spacing, E.G.) (All Itemss Differing In Make/Prices Need To Be Mentioned Seperately. Quote Separately If Different In Terms Of Material, Braiding, Electrode Material Platinum, Palladiumor Stainless Steel Etc) Quote With Appropriate Connector To Existing Ept 1000 And Stockert Ablators. Ept 1000 Is Not Compatible With Thermocouple And Appropriate Catheters/ Connectors Should Be Quoted. Thermistor Catheters Would Therefore By Preferred. In Addition Give Prices Of All Connector Cables / Accessories Seperately. All Items Should Be Compatible With Existing Ep Tracer Machine In Rnt Medical College, Udaipur Type Ablation Catheter Irrigated Tip(Open) Tip Sizeanydiameter 7-9Fcurves/Reach All Curves/Reachcomments , Catheters, Cables, Accessories For Endocardial Solutions (Esi) Accessories , Reusable Defibrillation/Transcutaneous Pacing Patches (Suitable For Equipment In .) , Cryo Catheters (And Accessories)For Ablation Of Arrhythmias In Children And Adults –

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 03-06-2025 Technical Bid Technical Bid 16-06-2025
2 03-06-2025 Date change Date 16-06-2025
3 13-05-2025 Corrigendum date extension Date 30-05-2025
4 28-05-2025 date corrigendum Date 04-06-2025

Key Dates

Publish Date 03-06-2025
Last Date of Bid Submission 16-06-2025
Tender Opening Date 05-06-2025

Contact Information

Company Name Rabindranath Tagore Medical College
Contact Person MEMBER SECRETARY
Address SSH HOSPITAL RNT MEDICAL COLLEGE

Other Detail

Information Source https://eproc.rajasthan.gov.in
Download FileName File Description File Size
Download cardoi.pdf Tender Documents 0 KB
Download b7cc03b4-26bc-484c-a9f4-74d0c0e5b35d.html Tender Documents 0 KB
Download Tendernotice_1.pdf Tender Documents 0 KB
Download BOQ_835764.xls Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.