Annual Framework Contract For Repairs To Electrical Works Of Various Lift Irrigation Schemes Of Mechanical Irrigation Division Anantnag Hq Awantipora- 1 Mechanical transportation, loading, unloading and stacking of various items / machinery equipment using appropriate means of transport as under:Private car, auto-rickshaw or similar with 1.0 km lead 2 Extra per kilometer for lead >1.0 kms upto 5.0 kms 3 Extra per kilometer for lead >5.0 kms upto 10.0 kms 4 Extra per kilometer for lead >10.0 kms upto 20.0 kms 5 Extra per kilometer for lead >20.0 kms upto 30.0 kms 6 Load carrier auto, mini van or similar with 1.0 km lead 7 Extra per kilometer for lead >1.0 kms upto 5.0 kms 8 Extra per kilometer for lead >5.0 kms upto 10.0 kms 9 Extra per kilometer for lead >10.0 kms upto 20.0 kms 10 Extra per kilometer for lead >20.0 kms upto 30.0 kms 11 Mini truck like Tata mobile, Bolero Camper or similar with 1.0 km lead 12 Extra per kilometer for lead >1.0 kms upto 5.0 kms 13 Extra per kilometer for lead >5.0 kms upto 10.0 kms 14 Extra per kilometer for lead >10.0 kms upto 20.0 kms 15 Extra per kilometer for lead >20.0 kms upto 30.0 kms 16 Truck, tipper or similar with 1.0 km lead 17 Extra per kilometer for lead >1.0 kms upto 5.0 kms 18 Extra per kilometer for lead >5.0 kms upto 10.0 kms 19 Extra per kilometer for lead >10.0 kms upto 20.0 kms 20 Extra per kilometer for lead >20.0 kms upto 30.0 kms 21 Head load carriage of machinery/ equipment at locations inaccessible by vehicles on plain/ rough terrainupto 50 kg load 22 Extra for every additional 50kgs load (Note: Fraction >=25kgs shall be taken as equivalent to next load of 50kgs) 23 Extra for uphill terrain (Ground Slope >= 07 deg) 24 Hiring of mobile crane up to 5 Ton capacity 25 Hiring of hydraulic back hoe loader. 26 Hiring of excavator for earthwork excavation. 27 MOTORS DISMANTLING AND ASSEMBLINGDisconnecting of all motor leads, dismantling of motor, draining off the m.oil (if applicable) and collection in suitable pan, carefully taking out the rotor from the stator, and completely disassembly as per requirement of job: Up to 10 HP 28 >10 HP –60 HP 29 >60 HP – 200 HP 30 > 200 HP -350 HP 31 > 350 HP 32 > 500 HP (HV motor) 33 Complete assembling of all motor parts, refilling of drained out M. Oil (if applicable), coupling and alignment with pump, reconnecting of leads and testing on full load.Up to 10 HP 34 >10 HP –60 HP 35 >60 HP – 200 HP 36 > 200 HP -350 HP 37 > 350 HP 38 > 500 HP (HV motor) 39 Complete rewinding of submersiblemotors of different ratings in PVC insulated copper wire of proper pitch, grade, gauge and number of turns as per sample after complete removal of burnt out winding, cleaning of slots, etc.. The job includes all the charges on account of , sleeves, bamboo sticks and skilled labour (Rewinding charges), testing of motor on full load at site. 40 Repairs to Non Reverse Ratchet on Driving End (DE) of Vertical electric motor by way of: Disconnecting all leads from motor and marking the terminals, uncoupling and dismounting of motor from the motor stool. Removal of non-reverse ratchet plate/ seal plate/ ratchet pins, etc as per requirement and refitting after necessary repairs/ replacements. Refitting of motor, coupling and alignment with the pump. The job includes testing of motor on load. 41 Replacement of Non Reverse Ratchet on Non Driving End (NDE) of Vertical electric motor by way of: Isolating the motor, dismantling of top end cover of the motor, removing of non-reverse ratchet plate/ seal plate/ ratchet pins, etc as per requirement and refitting back of parts after necessary repairs/ replacements and testing of motor on load. 42 Replacement of Driving End (DE) bearing of Vertical electric motor by way of: Disconnecting all leads from motor and marking the terminals, uncoupling of motor from the pump, dismounting of motor from the motor stool. Opening the bottom end cover of DE bearing housing. Carefully extracting the old damaged bearing from the housing with the help of bearing puller, etc and fitting of new bearing in its place. Refitting back of motor parts, coupling and alignment with the pump. The job excludes the cost of bearingUp to 60 HP 43 >60 HP – 200 HP 44 > 200 HP -350 HP 45 > 350 HP 46 > 500 HPHV Motors 47 Replacement of Non Driving End (NDE) bearing of Vertical electric motor by way of: Disconnecting all leads from motor and marking of terminals, dismantling of top end cover of the motor & removal of nonreverse ratchet assembly. Draining off the m.oil and collection in a suitable pan (if applicable), extraction of old damaged bearing from the motor, fitting of new NDE bearing and refilling of old m.oil. The job includes load testing of motor.Up to 60 HP 48 >60 HP – 200 HP 49 > 200 HP -350 HP 50 > 350 HP 51 > 500 HP (HV motor) 52 Replacement of Driving End (DE) bearing of horizontal electric motor by way of: Disconnecting all leads from motor and marking the terminals, uncoupling of motor from the pump. Opening the end cover of DE bearing housing. Carefully extracting the old damaged bearing from the housing with the help of bearing puller, etc and fitting of new bearing in its place. Refitting back of motor parts, coupling and alignment with the pump. The job includes testing of motor on load. Up to 60 HP 53 >60 HP – 200 HP 54 > 200 HP -350 HP 55 > 350 HP 56 > 500 HP (HV motor) 57 Replacement of Non Driving End NDE) bearing of horizontal electric motor by way of: Disconnecting all leads from motor and marking the terminals, uncoupling of motor from the pump. Opening the end cover of NDE bearing housing. Carefully extracting the old damaged bearing from the housing with the help of bearing puller, etc and fitting of new bearing in its place. Refitting back of motor parts, coupling and alignment with the pump. The job includes testing of motor on load. Up to 60 HP 58 >60 HP – 200 HP 59 > 200 HP -350 HP 60 > 350 HP 61 > 500HP (HV Motor) 62 Supply of new bearing as under: (Make: SKF imported/ equivalent imported)3210 A/C3 63 3212 A/C3 64 3213 A/C3 65 3309 A/C3 66 3313 A/C3 67 51310bearing 68 51312bearing 69 51314bearing 70 51320bearing 71 6014bearing 72 6220bearing 73 6314bearing 74 6315bearing 75 6320bearing 76 6324bearing 77 6406bearing 78 6408bearing 79 6410bearing 80 6411bearing 81 6412bearing 82 6415bearing 83 6418bearing 84 NU322 ECJ 85 NU324 ECJ 86 29322 E 87 29324 E 88 29328 E 89 29330 E 90 29424 E 91 29426 E 92 Supply of new bearing as under: (Make: Schaeffler (FAG)imported/ equivalent imported)6220 93 6317bearing 94 6318bearing 95 6319bearing 96 6320bearing 97 29322-E1-XL 98 29324-E1-XL 99 29326-E1-XL 100 29328-E1-XL 101 29330-E1-XL 102 29424-E1-XL 103 29426-E1-XL 104 Supply of new bearing as under: (NBC/ ARB/ ZKL/ equivalent domestic)3210 105 3212bearing 106 3213bearing 107 3306bearing 108 3307bearing 109 3309bearing 110 3310bearing 111 3311bearing 112 3312bearing 113 3313bearing 114 51310bearing 115 51312bearing 116 51314bearing 117 51320bearing 118 51322bearing 119 6014bearing 120 6028bearing 121 6217bearing 122 6220bearing 123 6305bearing 124 6306bearing 125 6307bearing 126 6308bearing 127 6309bearing 128 6310bearing 129 6311bearing 130 6312bearing 131 6313bearing 132 6314bearing 133 6315bearing 134 6320bearing 135 6322bearing 136 6406bearing 137 6408bearing 138 6410bearing 139 6411bearing 140 6412bearing 141 6415bearing 142 7312bearing 143 Providing and fitting of new plummer block/ bearing housing with designation as under: (Prefered makes: Masta/ SIBCO)S 507 144 S 508 145 S 509 146 S 510 147 S 511 148 S 512 149 S 513 150 S 515 151 S 516 152 S 517 153 S 518 154 S 519 155 S 520 156 S 522 157 S 524 158 VOLTAGE STABILIZER : Dismantling of 415V 3-ph Voltage Stabilizer by way of opening of top lid, disassembling of voltage regulator, removing of all incoming and outgoing connections, taking out of damaged copper legs after removal of core, etc. The job includes draining out of T. Oil and its safe placement for further refilling.Up to 50 KVA 159 >50 KVA - 100 KVA 160 >100 KVA – 250 KVA 161 >250 KVA 162 Assembling of all parts of 3-phase Voltage Stabilizer, connecting of leads of all incoming and outgoing connections and refilling of old drained out of T. OilUp to 50 KVA 163 >50 KVA - 100 KVA 164 >100 KVA – 250 KVA 165 >250 KVA 166 Isolating and disconnecting of all incoming and outgoing leads from autotransformer starter. Draining out transformer oil from the oil tank and collecting in a suitable vessel. Taking out the damaged autotransformer coil assembly from oil tank. Upto 60 HP 167 >60 upto 200 HP 168 >200 HP upto 350 HP 169 greater than 350 HP 170 Fitting of autotransformer coil assembly in the starter oil tank, filling of t.oil in the tank, connecting all leads and load testing of the starter.Upto 60 HPRating 171 >60 upto 200 HP 172 >200 HP upto 350 HP 173 greater than 350 HP 174 Complete winding of stator coils of 3-phase LV horizontal/ vertical induction motor/ submersible motor/ autotransformer/ voltage stabilizer/ etc. and the like with suitable copper wire (excluding carriage and dismantling/ reassembling charges).(Note: The unserviceable scrap copper generated is not taken into account for estimation of rates and shall be accounted separately).Providing and fitting of finished new electrolytic grade copper wire windings with insulation in place of damaged windings including allied jobs such as varnishing (Becks or any other reputed make) drying, etc., (Both HV & LV) - per kg of winding. 175 Providing and fitting of finished new electrolytic grade copper strip windings with insulation in place of damaged windings including allied costs such as varnish (Becks or any other reputed make), drying, etc., (Both HV & LV) - per kg of winding. 176 Varnishing, impregnation and drying of stator windings of LT motors with standard quality varnish (Becks or any other reputed make) as specified below along with proper tapings, etc. as per requirement. (excluding dismantling/ refitting charges) of motors upto 5HP 177 > 5 HP upto 20 HP 178 > 20 HP upto 50 HP 179 > 50 HP upto 100 HP 180 > 100 HP upto 200 HP 181 > 200 HP upto 350 HP 182 > 350 HP 183 VOLTAGE STABILIZER : Providing and replacement of copper contact points on regulator plate 184 Providing and Fitting of LV copper terminal connectors with allied insulation _ (for finished weight of the connector) 185 ELECTROMAGNETIC BRAKESProviding and fitting of AC solenoid for electromagnetic brake of stroke length as under: (Preferred make: BCH or equivalent) Providing and fitting of AC solenoid for electromagnetic brake of stroke length as under: (Preferred make: BCH or equivalent) 25MM 186 30mm or above 187 Providing and fitting of AC solenoid brake having wheel diameter as under:4 inch 188 5.5 inch 189 7 inch 190 10 inch 191 Providing and fitting of drum for AC solenoid brake having wheel diameter as under4 inch 192 5.5 inch 193 7 inch 194 10 inch 195 Providing and fitting of brake lining for AC solenoid brake having nominal wheel diameter as under4 inch 196 5.5 inch 197 7 inch 198 10 inch 199 Providing and fitting of brake shoe assembly for AC solenoid brake having nominal wheel diameter as under:4 inch 200 5.5 inch 201 7 inch 202 10 inch 203 Providing and fitting of brake coil for AC solenoid brake having nominal wheel diameter as under:4 inch 204 5.5 inch 205 7 inch 206 10 inch 207 SLIP RING MOTORSProviding and replacement of carbon brush to 11kV slip ring motors as under : 65mm x 50mm x 25mm (Grade: M16E) 208 Providing and replacement of brass brush holder of HV slip ring motor with pocket sizes as under: 38x32 MM 209 POLES : Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required. 210 Erection of metallic pole of following lengths in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) standard/ suitable foundation including excavation and refilling etc. as required.Above 4.5 meter and upto 6.5 meter 211 Above 6.5 meter and upto 8.0 meter 212 Above 8.0 meter and upto 10.0 meter 213 Above 10.00 meter and upto 12.00 meter 214 Providing and fitting of 3-pole contactor (AC-3 duty) with specified coil voltage:L&T ML 1.5 215 L&T ML 2 216 L&T ML 3 217 L&T ML 4 218 L&T ML 6 219 L&T ML 12 220 L&T MNX 50 221 L&T MNX 70 222 L&T MNX 80 223 L&T MNX 95 224 L&T MNX 110 225 L&T MNX 140 226 L&T MNX 185 227 L&T MNX 225 228 L&T MNX 250 229 MK1 230 MK2 231 MU1 232 MU1H 233 MU2 234 MU3 235 ML2W 236 ML3W 237 ML4W 238 ML6W 239 Schneider Electric LC1F265 (without coil) 240 Schneider Electric LC1F330 (without coil) 241 Schneider Electric LC1F400 (without coil) 242 Schneider Electric LC1F630 (without coil) 243 32A AC-3 rating (Siemens 3TF/ L&T Type MO/ Schneider) 244 45A AC-3 rating with 2NO + 2NC auxillary contacts (Siemens 3TF/ L&T Type MO/ Schneider) 245 Providing and fitting of new AC coil with specified coil voltage for contactors:9A to 45A AC-3 rating (Siemens 3TF/ equivalent) 246 L&T ML 2/ 3 247 L&T ML 4/ 6 248 L&T ML 10/ 12 249 L&T MNX 50/ 70/ 80 250 L&T MNX 95/ 110/ 140 251 L&T MNX 185/ 225/ 250 252 L&T MNX 300/ 400 253 L&T MNX 550/ 650 254 Schneider Electric LC1F185/ LC1F225 255 Schneider Electric LC1F265/ LC1F330 256 Schneider Electric LC1F400 257 Schneider Electric LC1F630 258 Providing and fitting of new Contact kit set for contactors 32A AC-3 rating (Siemens 3TF/equivalent) 259 L&T ML 2 260 L&T ML 3 261 L&T ML 4 262 L&T ML 6 263 L&T ML 10 264 L&T ML 12 265 Providing and fitting of auxillary contactors/ control relay L&T MX0 having 04 contacts (all combinations) for AC control 266 L&T MX0 having 04 contacts (all combinations) for DC control 267 L&T ML (1NO+1NC) side mounting auxillary contact block 268 L&T MNX/MCX front mounting type having 04 contacts (all combinations) 269 TIMING RELAY Providing, fitting and setting up of single range auto reset synchronous ON delay timer (L&T or equivalent make) 270 Providing, fitting and setting of electropneumatic timing relay with timing range upto 60s; coil voltage 415V AC (BCH or equivalent make) .(2NO + 2NC) double block; ON delay 271 (2NO + 2NC) double block; ON & OFF delay 272 Providing and fitting of spares for electropneumatic timing relay (BCH make or equivalent)(2NO + 2NC) contact block 273 Magnetic coil 415V AC 274 Magnet frame assembly without coil 275 Providing, fitting and setting of DIN mounted electronic Timer (L&T GIC or equivalent make)Star Delta (range from 3s - 120s)240V AC 276 Star Delta (range from 3s - 30s)240 - 415V AC 277 ON delay (0.3s - 30hrs) 240V AC 278 THERMAL OVERLOAD RELAY : Providing, fitting and setting of thermal overload relay of specified relay range(Make: L&T MN2) Relay range in between 0.2A to 15A 279 14-23A 280 20-33A 281 24-40A 282 Providing, fitting and setting of thermal overload relay of specified relay range(Make: L&T MN5) 20-33A 283 30-50A 284 36-60A 285 45-75A 286 66-110A 287 Providing, fitting and setting of thermal overload relay of specified relay range L&T ML1 (Relay range in between 0.15A to 16A) 288 L&T ML2/3 (Relay ranges in between 9A to 42A) 289 MISCELLANOUS Providing and fitting of bakelite connection plate minimum 10mm thick as per given size for autotransformer with holes for connection studs drilled at requisite spots 290 Complete servicing of control wiring of ATS including checking, tightening of connections, tapping and insulation as per requirement. 291 Complete replacement of suitable copper control wiring of ATS including cable ties, connections, tapping and insulation as per requirement. 292 OIL IMMERSED STARTER SPARES :Providing and replacement of operating coil for oil immersed semi-automatic starter, upto 40HP 293 Providing and fitting of heavy duty contact kit set for semi-automatic/ fully automatic SD oil immersed starters (set of 03 moving and 06 stationary contacts)Upto 40 HP 294 Spares for oil immersed manual startersFixed finger contact 295 Moving tip contact 296 No volt coil 297 Moving drum contact (starters upto 40HP) 298 Moving drum contact (starters > 40HP) 299 Base plate Bakelite/ DMC (starters upto 40HP) 300 Base plate Bakelite/ DMC (starters > 40HP) 301 Steam carrier assembly (starters upto 40HP) 302 Steam carrier assembly (starters > 40HP) 303 Sequence shaft (starters upto 40HP) 304 Sequence shaft (starters > 40HP) 305 Bakelite tube for Sequence shaft (starters upto 40HP) 306 Bakelite tube for Sequence shaft (starters > 40HP) 307 Trip rod assembly (starters upto 40HP) 308 Trip rod assembly (starters > 40HP) 309 Lock lever 310 Cam assembly 311 Oil dashpot assembly 312 Overload coil (set of 03 nos.) upto 20HP 313 Overload coil (set of 03 nos.) 30- 40HP 314 Overload coil (set of 03 nos.) 50- 60HP 315 Overload coil (set of 03 nos.) 70- 80HP 316 Overload coil (set of 03 nos.) 90- 100HP 317 L&T MU-G SUBMERSIBLE PUMP CONTROLLER SPARESVolt-Ammeter 500V, 318 Electronic Star-Delta Timer 3-30s 319 Providing and fitting of Terminal Block60A - 3 way 320 100A - 3 way 321 Single phase preventing relay Sz5 type 322 Single phase preventing relay SDz5 type 323 Providing, fitting and setting of thermal overload relay of specified relay range(Make: L&T) MK1 (all ranges) 324 MU1 (all ranges) 325 MU2 relays of following ranges9 - 14A 326 13 - 21A 327 15 - 25A 328 20 - 32A 329 24 - 38A 330 28 - 42A 331 Providing and fitting of standard operating coil for following contactorsMK1/ MK2 332 MU1/ MU2/ MU3 333 Providing and fitting of contact bridge without contact of following contactorsMK1/ MK2 334 MU1/ MU2/ MU3 335 Providing and fitting of single moving contact of following contactorsMK1 336 MK2 337 MU1 338 MU2 339 MU3 340 SPARES FOR ACB (L&T C-POWER)Providing and fitting of pole assembly for draw out type ACB (L&T C-power)Upto 1250A 341 2000A 342 Providing and fitting of Arc Chute (440V) for ACB (L&T C-power)upto 1250A 343 1600 - 2000A 344 Providing and fitting of Jaw contact for ACB (L&T C-power)630-1000A 345 1250A 346 1600A/ 2000A 347 Providing and fitting of Fixed arcing contact for ACB (L&T C-power)800- 1600A 348 2000A 349 Providing and fitting of Moving arcing contact for ACB (L&T C-power)800- 2000A 350 Providing and fitting of Shunt release for ACB (L&T C-power) 351 Providing and fitting of Under Voltage Release for ACB (L&T C-power) 352 Providing and fitting of Earth Fault Release for ACB (L&T C-power) 353 Providing and fitting of Terminal Adaptor for Draw out L&T C-POWER ACB of ratings as under:upto 800 - 1250A 354 1600 - 2000A 355 Providing and fitting of thermal-Magnetic Release (type DN1) for L&T C-power ACB 356 Providing and fitting of CT for DN1 type L&T C-power ACB800/ 1000A 357 1250/ 1600A 358 2000A 359 Providing and fitting of main spring for 3-pole ACB (L&T C-power)800- 1600A 360 2000A 361 Providing of racking handle for draw-out type ACBs (L&T C-power) rating upto 2000A 362 Providing and replacement of spring charging motor (AC/ DC) 363 Providing and replacement of motor limit switch 364 SPARES FOR VCBProviding and replacement of Vacuum Interrupter Schneider VG-2 365 Providing and replacement of following VCB parts (Schneider HVX 800A):Tripping Coil 366 Release/ Closing Coil 367 Spring charging Motor 110V DC/ 230V AC 368 Motor Cut-off Limit Switch 369 INSTRUMENTATION AND PANEL ACCESSORIESProviding and fitting of 96x96 flush mounting 3-phase LED ammeter/ voltmeter of Class 1 accuracy (Make: L&T/ Schneider/ Rishabh/ AE) 370 Providing and fitting of flush type analog moving iron AC meter as under:(Make: Rishabh/ AE/ C&S/ BCH)48x48mm 500V voltmeter 371 96x96mm 500V voltmeter 372 144x144mm 500V voltmeter 373 96x96mm ammeter (5A CT operated) 374 Providing and fitting of flush type frequency meter with range 45-55Hz:(Make: Rishabh/ AE/ L&T/ Schneider/ BCH) 375 Providing and fitting of 10A line current ammeter selector switch with OFF (Make: L&T/Rishabh/ AE/ Teknic) 376 Providing and fitting of 10A voltmeter selector switch with OFF(Make: L&T/ Rishabh/ AE/ Teknic) 377 Providing and fitting of tape insulated ring type metering current transformers (AE/ Rishabh/ Crompton/ Kilburn) as under:100/5A or 150/5A - Class 1 - Burden 5VA 378 200/5A - Class 1 - Burden 10VA 379 400/5A - Class 1 - Burden 15VA 380 600/5A - Class 1 - Burden 15VA 381 800/5A - Class 1 - Burden 15VA 382 1000/5A - Class 1 - Burden 15VA 383 2000/5A - Class 1 - Burden 15VA 384 Extra for 1A secondary upto 600/1A over corresponding rate 385 Providing and fitting of analog VAC hour meter(Make: L&T or equivalent make)DIN mounting type 386 Flush mounting type 387 Providing and fitting of flush or projecting head push button with contact block (L&T/ Teknic/ ABB/ BCH/ Schneider or any other reputed make) 388 Providing and fitting of LED phase indicator with surge protection (L&T/ Teknic/ ABB/ BCH/ Schneider or any other reputed make) 389 Providing and fitting 3 Phase, 3/4 Wire adjustable Under & Over Voltage monitoring relay (Minilec VCT D2 or equivalent) 390 Providing, fitting and setting of 415V auto reset single phase preventor (L&T/ Minilec/ BCH or equivalent make) 50V or less unbalance & 1 C/ODIN mounted 391 50V or less unbalance & 1 C/OPanel wall mounted 392 70V or less unbalance & 2 C/ODIN mounted 393 Providing and fitting of 32A DP switch (Anchor/ SSK or any other reputed make) 394 Providing of HRC fuses (2A - 32A) ratings 395 Providing and fitting of Fuse holders for fuses upto 32A rating 396 Providing and fixing uPVC panel trunking with cover 15x15mm 397 25x25mm 398 VCB PANEL ACCESSORIESProviding and fitting of 96x96 flush mounting 3-phase LED Multifunction Meter of Class 1 accuracy (Make: L&T/Schneider) 399 Providing and fitting of LED Energy Meter of Class 1 accuracy with RS 485 port facility (Make: Schneider EM1200) 400 Replacement of Trip Circuit Supervision RelayAlstom VAX31 ZGAT74BCH 110V DC 401 Replacement of Master Trip RelayAlstom VAJH13 YF0752 110V DC 402 Providing and replacement of 3-phase Over Current & Earth Fault RelayMake: L&T Model: MC31AnX 403 Make : L&T Model: MC61CnX (with high set and RS-485 port) 404 Schneider MiCOM P111 405 Ashida ADR141A 406 Providing and replacement of motor protection relaySchneider Electric MiCOM P220 407 Providing and replacement of static under and over voltage relay (C&S BU1-AC-UO) 408 Replacement of Alarm annunicator of below mentioned specifications12-window (Proton Power Control/ equivalent) Op. Voltage : 110-125 V DC 409 Replacement of 4 inch nominal size electronic panel hooter (multivoltage). 410 Providing and replacement of multichannel temperature Scanner as under:16-channel input & 8 channel relay output (Masibus 85xx+) 411 Providing and fitting of 25A standard mounting type Breaker Control Switch (TNC) with 01 Trip + 01 Close 412 100W nominal output load Power Pack with Battery backup (ALAN India/ equivalent) 413 Providing and replacement of 1000uF 450VDC capacitor 414 Providing and replacement of anti pumping relay 415 TERMINALS / LUGS : Providing and crimping of various aluminium tube lugs (Dowells/ Action/ or any other reputed make) with tapping, insulation as under:16 sq. mm 416 25 sq. mm 417 35 sq. mm 418 50 sq. mm 419 70 sq. mm 420 95 sq. mm 421 120 sq. mm 422 150 sq. mm 423 185 sq. mm 424 225 sq. mm 425 240 sq. mm 426 300 sq. mm 427 400 sq. mm 428 500 sq. mm 429 630 sq. mm 430 Providing and crimping of various copper tube lugs (Dowells/ Action/ or any other reputed make) with tapping, insulation as under:16 sq. mm 431 25 sq. mm 432 35 sq. mm 433 50 sq. mm 434 70 sq. mm 435 95 sq. mm 436 120 sq. mm 437 150 sq. mm 438 185 sq. mm 439 225 sq. mm 440 240 sq. mm 441 300 sq. mm 442 400 sq. mm 443 500 sq. mm 444 630 sq. mm 445 CABLESProviding and fitting of PVC insulated 1100V flat 3-core industrial copper cable for submersible pump motors (Preferred makes: Finolex/ L&T/ Havells/ KEI/ Polycab)1.5 sqmm 446 2.5 sqmm 447 4.0 sqmm 448 6.0 sqmm 449 10.0 sqmm 450 16.0 sqmm 451 25.0 sqmm 452 35.0 sqmm 453 Providing and fitting of XLPE insulated, 1100V single core armoured industrial copper cable as under (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab)16.0 sqmm 454 25 sqmm 455 35 sqmm 456 50 sqmm 457 70 sqmm 458 95 sqmm 459 120 sqmm 460 150 sqmm 461 185 sqmm 462 240 sqmm 463 300 sqmm 464 400 sqmm 465 Providing and fitting of XLPE insulated, 1100V single core industrial armoured aluminium cable as under (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab)16 sqmm 466 25 sqmm 467 35 sqmm 468 50 sqmm 469 70 sqmm 470 95 sqmm 471 120 sqmm 472 150 sqmm 473 185 sqmm 474 240 sqmm 475 300 sqmm 476 400 sqmm 477 500 sqmm 478 630 sqmm 479 Providing and fitting of XLPE insulated, 1100V 3.5-core industrial armoured aluminium cable as per IS 7098 (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab)25 sqmm 480 35 sqmm 481 50 sqmm 482 70 sqmm 483 95 sqmm 484 120 sqmm 485 150 sqmm 486 185 sqmm 487 240 sqmm 488 300 sqmm 489 400 sqmm 490 500 sqmm 491 630 sqmm 492 CONTROL CABLES Providing and fitting of XLPE insulated, 1100V grade industrial armoured Copper control cable as per IS 7098 (Preferred make: Finolex/ Gloster/ Havells/ KEI/ Polycab)6C x 1.5 sq. mm 493 8C x 1.5 sq. mm 494 10C x 1.5 sq. mm 495 12C x 1.5 sq. mm 496 2C x 2.5 sq. mm 497 4C x 2.5 sq. mm 498 6C x 2.5 sq. mm 499 8C x 2.5 sq. mm 500 12C x 2.5 sq. mm 501 CABLE KITSProviding and fitting of Heat Shrinkable termination kit for 11 kV XLPE Cable (outdoor type)3C x 50 sq.mm 502 3C x 95 sq.mm 503 3C x 120 sq.mm 504 3C x 185 sq.mm 505 3C x 300 sq.mm 506 3C x 400 sq.mm 507 Heat Shrinkable termination kit for 11 kV XLPE Cable (Indoor type)3C x 50 sq.mm 508 3C x 95 sq.mm 509 3C x 120 sq.mm 510 3C x 185 sq.mm 511 3C x 300 sq.mm 512 3C x 400 sq.mm 513 Heat Shrinkable termination kit for 11 kV XLPE Cable (Indoor type)Upto 150 sq.mm 514 185 sq.mm to 300 sq. mm 515 Heat Shrinkable Straight Through Joint Kit for 11 kV HT AB CableUpto 120 sq.mm 516 150 sq.mm to 185 sq. mm 517 240 sq. mm to 300 sq.mm 518 WIRINGProviding and fitting of PVC insulated 1100V flexible copper cable (FRLS) for electrical installations as under (Preferred makes: Finolex/ Anchor/ L&T/ Havells/ KEI/ Polycab)1.0 sqmm 519 1.5 sqmm 520 2.5 sqmm 521 4.0 sqmm 522 6.0 sqmm 523 10.0 sqmm 524 16.0 sqmm 525 2x1.5 sqmm 526 2x2.5 sqmm 527 2x6 sqmm (Aluminium unarmoured) 528 CONDUITSProviding and fixing 25mm PVC round conduit (medium) with allied PVC fittings 529 Providing and fixing uPVC trunking 25x16mm with allied fittings 530 Providing and fixing Polypropylene Corrugated flexible conduit25mm 531 32mm 532 Providing and fitting perforated MS cable trays including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders or fixing on cantilever supports and including painting etc as required.100 x 50 x 1.6mm 533 150 x 50 x 1.6mm 534 ELECTRICAL FITTINGSProviding and fitting of various electrical fittings as under(Preferred makes: Anchor/ SSK/ Havells)Switch-6A-SP-1way, 240V, 50 Hz, AC. 535 Switch-6A-SP-2way, 240V, 50 Hz, AC. 536 Cord Switches:- Providing and fitting of cord switch-6A-SP-1way, 240V, 50 Hz, AC/ hanging bell push. 537 Bell push 240V, 50 Hz, AC. 538 6A Socket:- Providing and fitting of6A-2/3 pin-universal socket, 240V, 50 Hz, AC. 539 Neon indicator 540 Mini telephone jack 541 Fan regulator (Mini) with rotary step 542 Fan regulator (Deluxe) with rotary step 543 Shuttered-3 pin socket and switch (box/ recessed) - 20A-SP-1 way, 230V 50 HZ, AC. 544 Plug Top 15/16A 3 Pin (ISI Marked) 545 32A TP switch 415V with neon 546 32A DP switch 240V with neon 547 Surface mounting box for switches as follows:1 Gang box 548 2 Gang box 549 3 Gang box 550 4 Gang box 551 5 Gang box 552 6 Gang box 553 7 Gang box 554 4 Gang box (double domestic) 555 Providing, Fixing, Testing of 6A ceiling rose 556 Providing and installation of Pendant/ angle/ batten holders 6A 240V 557 Providing and installation of SPN sheet steel enclosed Distribution boxes - Single door (Make: L&T/ Legrand/ Hager/ Havells/ Benlo)4 way 558 8 way 559 12 way 560 16 way 561 Providing and installation of ‘B’ Series MCB 240V, 50Hz, 10kA Suitable for lighting and other domestic loads (Preferred Make: L&T/ Legrand/ Hager/ Havells/ Schneider)6-32A SP 562 40A SP 563 6-32A DP 564 40A DP 565 100A 4P isolator 566 Providing and installation of Change over switches of metal enclosure 240v 50Hz (Preferred make: Anchor/ SSK/ Havells/ L&T)2-pole 16A 415V 567 2-pole 32A 415V 568 4-pole 32A 415V 569 4-pole 63A 415V 570 4-pole 100A 415V 571 Providing and installation of Busbar chamber 3-ph 4 bar heavy duty copper strips with rating as under(Preferred make: Havells/ SSK/ L&T) 63A - 415V 572 100A 415V 573 200A 415V 574 Providing and installation of various type of fans as under:Industrial exhaust fan 450mm metallic 575 Exhaust fan 250mm Plastic 576 Ceiling fan 1200mm sweep 577 Wall fan 300mm sweep 578 PORTABLE LIGHTING3 W Rechargeable LED torch (Preferred make: Havells/ Eveready/ Andslite/ Philips/ Syska) 579 LED Lantern with Twin Charging mode –Charging Cable & Solar Panel (included) (Syska/ Havells/ Andslite/ Philips/ Bajaj) 580 MANPOWERHiring charges of Electrician (for troubleshooting/ revamping of existing electrical fitting, etc. exclusive of specified works): 581 Hiring charges of Labourer for support of electrician 582 16A TP measure circuit breaker for Priming at LIS Daderkoot (L$T make) 583 MCCBProviding and fitting of 3-pole 415V MCCB with thermal magnetic release having 36 kA breaking capacity (Ics= 100% Icu) (Make: L&T/Schneider or equivalent) having max. of thermal release range as under:100A 584 125A 585 160A 586 200A 587 250A 588 320A 589 400A 590 500 A 591 630A 592 800A 593 Providing and fitting of 3-pole 415V MCCB with thermal magnetic release having 50 kA breaking capacity (Ics= 100% Icu) (Make: L&T/Schneider or equivalent) having max. of thermal release range as under:125A 594 160A 595 200A 596 250A 597 320A 598 400A 599 500 A 600 630A 601 800A 602 Providing and fitting of 4-pole 415V MCCB with adjustable thermal and fixed magnetic setting having 36KA breaking capacity Ics = 100% Icu (Make: L&T d-sine or equivalent) Having max. of thermal release range as under:160A 603 200A 604 250A 605 320A 606 400A 607 500 A 608 630A 609 800A 610 Providing and fitting of 4-pole 415V MCCB with adjustable thermal and fixed magnetic setting having 50KA breaking capacity Ics = 100% Icu (Make: L&T d-sine or equivalent) Having max. of thermal release range as under:160A 611 200A 612 250A 613 320A 614 400A 615 500 A 616 630A 617 800A 618 Magnetic Coils for Contactors 3 and 4 poleLCIFJ43 619 LCIF330 620 LCIFDP500 621 providing fitting of AL conductor 0.03 622 providing fitting of AL conductor 0.05
|