Tender For Repair/Replacement/Maintenance External Lt Network Including Lt Equipment And Allied Works At Mil Stn Suranussi Under Age (I) Suranussi, jalandhar-Punjab

Military Engineer Services-MES has published Tender For Repair/Replacement/Maintenance External Lt Network Including Lt Equipment And Allied Works At Mil Stn Suranussi Under Age (I) Suranussi. Submission Date for this Tender is 19-12-2022. Overhead Line Tenders in jalandhar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

35063417
Corrigendum : Tender For Repair/Replacement/Maintenance External Lt Network Including Lt Equipment And Allied Works At Mil Stn Suranussi Under Age (I) Suranussi
Open Tender
Indian
Punjab
jalandhar
19-12-2022

Tender Details

Repair / Replacement / Maintenance External Lt Network Including Lt Equipment And Allied Works At Mil Stn Suranussi Under Age ( I ) Suranussi Please Refer Tender Documents

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 12-Dec-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 19-12-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 48000.0 /-
Tender Value
INR 24 Lakhs /-

BOQ Items

Name of Work: Repair/Replacement/Maintenance external LT network including LT equipment and allied works at Mil Stn Suranussi under AGE (I) Suranussi
Sl. No. Item Description
1Excavation over areas in soft/loose soilnot exceeding 1.5 mtrdeep and not exceeding 1.5 mtrwide for laying of cables,poles/stays and struts etc and getting out including trimming sides and forming bottom surface all as specified and directed at site.
2Returning, filling in including spreading, leveling, watering and well ramming excavated hard/soft in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays , struts have been erected and tested, all as specified and directed.
3Removing excavated surplus soil (Soft/loose soil) obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and directed.
4Material and labour for clean dry sand laidin trenches/ducts for cushioning to cable complete all as specified.
5Supplying and laying cable cover precost concrete Class LV, Type I, flat, size 250 mm x 150mm x 40mm
6Supplying, Laying and Jointing testing and commissioning XLPE UG cable, sheathed armoured LT 1100 grade heavy duty with Stranded aluminum conductor through pipes in ducts. Poles/ trenches incl fixing of copper lugs, making good to disturbed surface etc for the following cross sectional area complete as per following size :- (Note : Excavation and earth work to be measured and paid separately.)
710 Sqmm 2 core
816 Sqmm 4 core
935 Sqmm 3.5 core
1050 Sqmm 3.5 core
1170 Sqmm 3.5 core
1295 Sqmm 3.5 core
13120 Sqmm 3.5 core
14150 Sqmm 3.5 core
15185 Sqmm 3.5 core
16Supply and fix GI tubing light grade for encasing cables for mechanical protection, laid under plinth/floors/ roads/ path /culverts or fixed on walls/on poles by means of MSFI clamps with necessary bolts, nuts and washers all as specified of sizes 50mm bore
17Dismantling & taking down existing ACSR conductor of any size by opening the binding wire from LT electric poles complete all as specified.
18Taking downcross arms, channels, angle iron, clamps, nut, bolts, stay wire, stay assembly, GI wire, anti climbing devices, danger notice boards etc complete al assoecified and directed .
19Taking down old brokenLT PCC poles carefully and including breaking of PCC making good the disturbed surface.
20Taking down old rusted GI pipe of any size from pole/trench complete all as specified.
21Taking down insulators off size & type all as specified.
22Taking out old defective/burnt underground cable fromtrenches/ floors/road/wall /pipe/ pole LT cable of any size/ description including complete all as specified and directed
23Supply and fixing and stringing in replacement ACSR conductor (weasal /Ferret /squirrel) on LT poles / service brackets including binding of conductor with aluminum binding wire complete all as specified and directed.
24Supply and fixing MS cross arms, bracing, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding bending, cold or hot, drilling joles or bolt in any shape of size including 2 coat of aluminium paint over a coat of red oxide primer complete all as specified and directed.
25Supply and fixing continues earth wire 4 mm dia galvanised steel wire including galvanised mild steel binding wire 14 SWG complete all as specified. Note : For payment purposed wt of 4 mm dia galnanised wire only shall be taken and clamps, hooks shall be measuredand paid separately.
26Supply, erecting intruely vertically position concrete pole 9 Mtr long of size 102 mm x 172 mm at top and 102mmx279 mm at bottom class 10 complete including painting of pole up to 1.5 Mtr high from PCC coping in black & white strip each of 30mm highwith two coats of synthetic enamel paint complete all as specified and directed (Excavation/ earthwork/PCC work shall be measured & paid separatelly) including taking out existing unserviceable pole & removing from site.
27Supply and fixing Pin type insulator porcelain viterous white brown or green incl one galvanised mild steel spindle two galvanised iron washer and one galvanised iron nutrs 150 mm height, 150 mm dia for11000 volts grade. MakeJaipur/Rashtriya
28Supply and fixing Disc type composite polymeric insulators, 11000 volts grade, 45 KN, with tension clamps, bolts, nuts etc complete all as specified and directed . MakeJaipur/Rashtriya
29Supply and fixing Loop type insulator porcelain vitreous, white or brown for HT saylarge size with overall diamensions 65 x 140 mm, clearance hole20 mm for 11000 volts grade. Make Jaipur/Rashtriya
30Material & labour for PCC work (1:4:8) type D-2 using 40 mm graded stone aggregate in foundation of electricpole, etc including necessary form work and fare finish to exposed surfaces without using extra cement etc.Complete all as specified.
31Material & labour for PCC work (1:3:6) type C-2 using 40 mm graded mechnically crushed stone aggregate in foundation of stay/coping of cpole including necessary form work and fare finish to exposed surfaces without using extra cement etc.Complete all as specified.
32Material and labour for plain cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregates for coping around poles,including necessary form work finishing even and smooth without using extra cement all as specified and directed.
33Material and Labour for stay assembly complete with 20 mm dia, 2100 mm long stay rod with threaded ends and GI nuts, two numbers thimbles MS clamps made out of 40 mmx 6 mm flat iron including MS nuts bolts and washers 300 mm x 300 mm x 6 mmMS stay plate stay bow of size 40 cm long 16 mm dia, loop type insulator including painting the exosed MS work with2 coats of aluminium paint over a coat of red oxide primer complete all as shown in electrical plate No 1 (Earth work, concrete work, loop type insulators, stay strand, clamp shall be measured and paid for separately.
34Material and Labour for galvanised stay strand size 7/4 mm complete all as specified and directed by Engr-in-Charge.
35Supply and fixing for Danger notice plate for HT of 25 cm x 20 cm x 1.6 mm thick mild steelsheet vitreous enameled white, with letters figures and conventional skuull and bones and written as "DANGER" in signal red colour and fixed with MS clamps made out of MS flat 25 mm x 3 mm , including nuts &bolts including 2 coats of aluminium paint over a coat of red oxide primer all as specified. Note :- Instructions are to bewritten in three languages viz Punjabi Hindi and English.
36Dismantling and taking down GO Switch off size including, operating machanismetc complete from any position.
37Supplying and fixing switch Air break Gang Operated Switch outdoor type HT 11 KV triple poles 400 amps withfixed contacts of phosphorus bronze and moving contacts of copper withmechnically operating from ground level vertical mounted complete with HT insulator on steel frame operating rod made out of25 mmGI pipe medium grade worked from ground level with handle and locking arragement with12 insulators with drop out fuses complete all as per specified and directed by Engr-in-Charge and (Clamps/cross arms shall be measured and paid for separately) Make : Jaipuria/Rashtrya.
38Supply, fixing and testing & cable jointing Kit for 11 KV grade cable for indoor type ermination cold shrinable joint complete with joining material and accessories suitable for XLPE armoured aluminium cable of size 95 Sqmm 3 Core. Make : Denson/M Seal/Raychem.
39All as per item No 29here-in-before in before but of size 120 sqmm to 185 sqmm 3 core.
40Supply,fixing and testing after jointing Cable jointing Kit for 11 KV grade cable for outdoor type termination cold shrinkable joint complete with jointing material and accessories suitable for XLPE armoured aluminium cable of size 95 Sqmm 3 core.Make - Denson, M Seal/Raychem
41All as per item No 31here-in-before in before but of size 120 sqmm to 185 sqmm 3 core.
42Supplying and laying synthetic Rubber insulated mats 25 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m
43Supply and fixing for Danger notice plate for LT of 20 cm x 15 cm x 1.6 mm thick mild steelsheet vitreous enameled white, with letters figures and conventional skuull and bones and written as "DANGER" in signal red colour and fixed with MS clamps made out of MS flat 25 mm x 3 mm , including nuts &bolts including 2 coats of aluminium paint over a coat of red oxide primer all as specified. Note :- Instructions are to bewritten in three languages viz Punjabi Hindi and English.
44M&L for bolders filling exceeding 15 cm and upto 30 cm dia in transformer filling complete.
45Supply and fixing plastic line phase separators for separating 4/3 Nos. of over head line conductors length 900 to 600 mm width 25 mm with fly nuts and clamps suitable for 1100 volts grade LT elect lines of any size fixed with existing over head elect lines all as directed.
46Material and labour for scrapping the surface of panels and existing poles complete with 2 coatsof Zinc chromate primer of approved make: Berger/Asian
47Material and labourfor Prunning of tree branches of any sizes and dia,not less than 2 Mtr around the LTOH line which obstructing the power supply/ maintenance of electric supply as well as illumination in area including repair of damage broken ACSR conductor, GI wire and jumpers and disposed exc 50 mtr away clearing area complete testing of line all as directed. (Note : (i) Rate quoted inclusive are repair to damage work in item)(ii) Each Span approx 30-40 Mtr.
48Supply and fix inreplacement; MCCB 160 Amp, 4 pole, 36 KA 415 Volt 50 Hz with adjustable thermal release and adjustable magnetic setting complete all as specified and directed. Make : Havell"s/ Siemen"s/ L & T
49Supply and fix inreplacement; MCCB 250 Amp, 4 pole, 36 KA 415 Volt 50 Hz with adjustable thermal release and adjustable magnetic setting complete all as specified and directed.Make : Havell"s/ Siemen"s/ L & T
50Supply and fix inreplacement; MCCB 350 Amp 04 pole 415 volt 50 HZ breaking capacity 36 KA with adjustable thermal release and adjustable magnetic setting complete all as specified and directed. Make : Havell"s/ Siemen"s/ L & T
51Supply and fix inreplacement; MCCB 400 Amp 04 pole 415 volt 50 HZ breaking capacity 36 KA with adjustable thermal release and adjustable magnetic setting complete all as specified and directed. Make : Havell"s/ Siemen"s/ L & T
52Supply, fabricating installation,electrically connected LT Busbar chamber size 450mm X 300mm X 150mm out door cubical type factory made of CRCA sheet 3.15 mm thick machine pressed and angle iron frame 40x40x6mm in around the busbar chamber body fixing on the wall including spray painted with two coats ofsynthetic paint from out side and inside with approved stove enameled gray paint over one coat of red oxide primer complete and suitable for 230 Volts AC single Phase 2 wire Aluminum bus bar of each capacity 100Amp & strips fully mounted on porcelain insulator including cable connection and connected acessories.
53Supply and fixing off load change over switch 415 V 50 HZ Type FP 125 Amp Make : IndoAsian/Havells/L&T or equivalent
54Material and Labour earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required aluminium strip 25x3 mmcomplete all as specified and directed .
55Material and Labour earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required galvanised iron strip 32x6 mmcomplete all as specified and directed .
56Supply installation testing and commissioningin replacement panel board of size 1M X 0.9M X 0.45Mwith3 phase and neutral 415 volt out door type factory made free standing, inter locking arrangement, plate form mounting, dust and vermin proof cubical type IP-42protection fabricated with 3.15 mm CRCA sheet outdoor type with anti corrosive coating and finally polyester powder coating in Gray shade fully compartmentalized design with 4 No’s bus bar made of high conductivity copper of 90% pure ETP Gray suitable for 1.5 times the rated capacity of the incommer MCCBpre-wired with suitable size of copper strip having colur coading sleeves copper strip short circuite rating 50 KA (rms) for one second including suitable aluminium arth strips confirming to IS and necessary brass cable glands for incomming and outgoing cables angle iron frame of size 50x50x5 mm thick and base of channels and fittings and lugs of suitable size at top to lift the panel safly with minimum60cm ground clearance and necessary foundation and all as specified with supply and fixingall as required and directed at site for the following :- (a)MCCB 4 pole 415 volts 400 Amps 35 KA with adjustable thermal setting- 01 No (Incoming) (b) MCCB 4 pole 415 volts 250 Amps 35 KA with adjustable thermal setting- 02 No(Out Going) (c) MCCB 4 pole 415 volts 63 Amps 35 KA with adjustable thermal setting- 01 No (Out Going) (d)Volt meter digital type - 01 No (e) Ammeter 0-100Amp - 01 No (f) Indicator (RYB) - 03 Nos
57M&L for earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground earth pit not less than 2.25 mtr below normal GL with the top edge of the plate not less then 1.5 mtr below the normal GL connected to GI strip 32 x 6mm by means of bolts, nuts, check nuts and washer of galvanised iron or steel and protected by 40mm GI pipe (light grade) and watering pipe 20mm bore GI pipe (light grade) including GI wire meshed funnel and chamber PCC (1:4:8) type D2 using 40mm grade stone aggregate, coping shall be (1:3:6) type CI using 20mm stone aggregate with RCC 1:2:4 type B1 (using 20mm graded stone aggregate) pit cover re-inforced with 8mm dia at 80mm c/c both way in lieu of CI pit cover with angle iron frame, including excavation and earth work in any type of soil and removal of surplus soil of earth complete all as shown in electrical plate of SSR Part I and as specified including charcoal dust, common salt complete and earth lead connected to earthing test point all as specified and testing of earthing on completion. NOTE 1. The unit rate includes for protection pipe and GI strip 32X6mm from top of earth plate up to 7.5 meter above ground level.
58M&L for earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground earth pit not less than 2.25 mtr below normal GL with the top edge of the plate not less then 1.5 mtr below the normal GL connected to GI wire 4mm dia by means of bolts, nuts, check nuts and washer of galvanised iron or steel and protected by 15mm GI pipe (light grade) and watering pipe 20mm bore GI pipe (light grade) including GI wire meshed funnel and chamber PCC (1:4:8) type D2 using 40mm grade stone aggregate, coping shall be (1:3:6) type CI using 20mm stone aggregate with RCC 1:2:4 type B1 (using 20mm graded stone aggregate) pit cover re-inforced with 8mm dia at 80mm c/c both way in lieu of CI pit cover with angle iron frame excavation and earth work and removal of surplus soil of earth complete all as shown in electrical plate of SSR Part I and as specified including charcoal dust, common salt complete and earth lead connected to earthing test point all as specified and testing of earthing on completion. NOTE 1. The unit rate includes for protection pipe and GI earth wire 4.00mm dia from top of earth plate up to 7.5 meter above ground level.
59Tightening and restringing existing loose/broken conductor (ACSR/Copper)/GI continuous earth wire any type including stringing including replacement of fresh binding wire all as required at site all as directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail