Power Development Department has published Tender For Execution Of Works For Redressal Of Public Demand From Panchayat Makwal Block Nagrota Regarding Laying Of Ht/Lt Network Etc On Turnkey Basis. Submission Date for this Tender is 14-01-2023. Overhead Line Tenders in kathua Jammu And Kashmir. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 22-Dec-2022 | extension01 | Date | 29-12-2022 |
2 | 31-Dec-2022 | extension02 | Date | 07-01-2023 |
3 | 09-Jan-2023 | extension03 | Date | 14-01-2023 |
Sl. No. | Item Description |
1 | Name of Work-Creationof 25 KVASub Station at KhrariPyt Makwal |
2 | Creationof 25 KVASub Station at KhrariPyt Makwal on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material: |
3 | 11/0.433kV, 25 KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al wound ), and with LV Cable Box having detachable Aluminium Gland plate. |
4 | Gapless Surge Arrestor,9 kV ,10 KA ,LA with polymer housing, Stn. Type |
5 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
6 | 11 kV Horn GapFuse Set 3 Phase 200A |
7 | 50 mm² (1Ckt) Single PhaseCable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS type |
8 | 9 Mtr. Long PCC Pole(WL-300 Kg) |
9 | 11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
10 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
11 | GI Channel/Angle/Flat of sizes including clamps |
12 | Galvinized Nuts and Bolts. |
13 | Cement Bottoming 1:2:4 mix as per REC Standards |
14 | Earthing of substation-Excavation ofearth pit of dia650 mm & depth 3000 mm, installation ofEarthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
15 | Pre fabricated LT Distributionswitch |
16 | Danger Plates with Clamps |
17 | Sundary Items |
18 | GI Barbed wire for anticlimbing |
19 | Laying ofHT line on 9 Mtrs.PCC poles with ACSR Weasel Conductor at KhrariPyt Makwal on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material: |
20 | 9 Mtr. Long PCC Pole(WL-300 Kg) |
21 | GI V cross-arm/Horizontal with top Bracket including clamp |
22 | GI Channel x-arm includingclaps and braces |
23 | 30 mm² ACSR Conductor |
24 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
25 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
26 | Galvanized Nuts and Bolts |
27 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
28 | Danger Plates with Clamp |
29 | Anti Climbing Devices with clamps |
30 | Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip |
31 | Laying ofLT line on 8 Mtrs.PCC poles with ACSR Weasel Conductor 3 Phase 4 wireat at KhrariPyt Makwalon Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material: |
32 | 8 Mtr. Long Pole(PCC WL-200Kg ) |
33 | GI U-Clamp for Shackle insulators |
34 | Shackle insulator 16 KN |
35 | 30 mm² ACSR Conductor |
36 | Galvanized Nuts and Bolts |
37 | Danger plates |
38 | Anit Climbing Device with Clamps |
39 | Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip |
40 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
41 | LT line Spacers |
42 | Stone Pad |
43 | Alm.Jointing Sleeves |
44 | Name of Work-Creationof 25 KVASub Station at ChambaDa Bagh Pyt Makwal |
45 | Creationof 25 KVASub Station at ChambaDa Bagh Pyt Makwalon Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material: |
46 | 11/0.433kV, 25 KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al wound ), and with LV Cable Box having detachable Aluminium Gland plate. |
47 | Gapless Surge Arrestor,9 kV ,10 KA ,LA with polymer housing, Stn. Type |
48 | 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type |
49 | 11 kV Horn GapFuse Set 3 Phase 200A |
50 | 50 mm² (1Ckt) Single PhaseCable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS type |
51 | 9 Mtr. Long PCC Pole(WL-300 Kg) |
52 | 11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
53 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
54 | GI Channel/Angle/Flat of sizes including clamps |
55 | Galvinized Nuts and Bolts. |
56 | Cement Bottoming 1:2:4 mix as per REC Standards |
57 | Earthing of substation-Excavation ofearth pit of dia650 mm & depth 3000 mm, installation ofEarthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. |
58 | Pre fabricated LT Distributionswitch |
59 | Danger Plates with Clamps |
60 | Sundary Items |
61 | GI Barbed wire for anticlimbing |
62 | Laying ofHT line on 9 Mtrs.PCC poles with ACSR Weasel Conductor at ChambaDa Bagh Pyt Makwal on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material: |
63 | 9 Mtr. Long PCC Pole(WL-300 Kg) |
64 | GI V cross-arm/Horizontal with top Bracket including clamp |
65 | GI Channel x-arm includingclaps and braces |
66 | 30 mm² ACSR Conductor |
67 | 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
68 | 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm |
69 | Galvanized Nuts and Bolts |
70 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
71 | Danger Plates with Clamp |
72 | Anti Climbing Devices with clamps |
73 | Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip |
74 | Laying ofLT line on 8 Mtrs.PCC poles with ACSR Weasel Conductor 3 Phase 4 wireatChambaDa Bagh Pyt Makwal on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material: |
75 | 8 Mtr. Long Pole(PCC WL-200Kg ) |
76 | GI U-Clamp for Shackle insulators |
77 | Shackle insulator 16 KN |
78 | 30 mm² ACSR Conductor |
79 | Galvanized Nuts and Bolts |
80 | Danger plates |
81 | Anit Climbing Device with Clamps |
82 | Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip |
83 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
84 | LT line Spacers |
85 | Stone Pad |
86 | Alm.Jointing Sleeves |
87 | Name of Work-LT Extension 1 Phase 2 Wire |
88 | Laying ofLT line on 8 Mtrs.PCC poles with ACSR Weasel Conductor 1 Phase 2 wireat Pyt Makwalon Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material: |
89 | 8 Mtr. Long Pole(PCC WL-200Kg ) |
90 | GI U-Clamp for Shackle insulators |
91 | Shackle insulator 16 KN |
92 | 30 mm² ACSR Conductor |
93 | Galvanized Nuts and Bolts |
94 | Danger plates |
95 | Anit Climbing Device with Clamps |
96 | Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip |
97 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
98 | LT line Spacers |
99 | Stone Pad |
100 | Alm.Jointing Sleeves |
101 | Laying ofLT line on 8 Mtrs.ST poles with ACSR Weasel Conductor 1 Phase 2 wireat Pyt Makwal on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material: |
102 | 8 Mtr. Long Pole(ST-410 SP-15) |
103 | GI U-Clamp for Shackle insulators |
104 | 30 mm² ACSR Conductor weasel |
105 | 16 KNPolymer Shackle insulators |
106 | Galvanized Nuts and Bolts |
107 | Danger Plates with Clamp |
108 | Anti climbing Devices with Clamp |
109 | Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip |
110 | Red oxide Paint |
111 | Aluminium Paints |
112 | Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete |
113 | Name of Work-Insertion/Replacement of PCC Poles |
114 | Replacement/insertionofdamage PoleinLT linewith 8 mtrs PCCPole at Pyt. Makwalon Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material: Note:- All thedismantlled reuseable material shall be returned to Divisional Store at kathua at no cost. |
115 | PCC pole 8 mtrs.long(W/L-200 Kg) |
116 | GI U Clamp for shackle insulator |
117 | 16KN Polymer shackle insulstor |
118 | Galvanised Nuts and bolts |
119 | 30mm2 ACSR WeaselConductor |
120 | Name of Work-Replacementofold LT Conductor atPyt Makwal |
121 | Rreplacementofold LT Conductor atPyt Makwal on Turnkey Basis by way of Supply, Erection/Installation, Testing, commissioning etc of the following material:Note:-All thedismantlled reuseable material shall be returned to Divisional Store at kathua at no cost. |
122 | 30mm2 ACSR WeaselConductor |
123 | GI U Clamp for shackle insulator |
124 | 16KN Polymer shackle insulstor |
125 | Galvanised Nuts and bolts |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy