}

Tender For Construction Of Urban Health Wellness Centre (U-H Wc) At Loco Subhas Para, Kulti, Ward No.-19 Within Asansol Municipal Corporation, asansol-West Bengal

Municipal Affairs Department has published Tender For Construction Of Urban Health Wellness Centre (U-H Wc) At Loco Subhas Para, Kulti, Ward No.-19 Within Asansol Municipal Corporation. Submission Date for this Tender is 19-12-2022. Building Work Tenders in asansol West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

35057798
Tender For Construction Of Urban Health Wellness Centre (U-H Wc) At Loco Subhas Para, Kulti, Ward No.-19 Within Asansol Municipal Corporation
Open Tender
Indian
West Bengal
asansol
19-12-2022

Tender Details

Construction Of Urban Health Wellness Centre ( U-H Wc ) At Loco Subhas Para, Kulti, Ward No.-19 Within Asansol Municipal Corporation

Key Value

Document Fees
Refer document
EMD
INR 68002.0 /-
Tender Value
INR 34 Lakhs /-

BOQ Items

Name of Work:Construction of Urban Health& Wellness Centre (U-H&WC) at Loco Subhaspara, Kulti, Ward no.- 19 underAsansol Municipal Corporation.
Sl. No. Item Description
1Civil work --Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.
2Earth work in excavation of foundation trenches or drains or septic tank soak well etc. in all sorts of soil (including mixed soil but excluding moorum and laterite or sand stone) including removing, spreading or stacking the spoils within a lead of 75 metre as directed,including trimming the bottom,side of trenches,levelling,dressing and ramming the bottom,bailing or pumping out water etc.as recuired complete.i) Depth of excavation not exceeding 1500mm(not rquiring soring)
3Earth work in filling in foundation trenches or plinth with good earth in layers not exceeding 15 c.m. including breaking clods watering and ramming etc.layer by layer complete.With earth obtained from excavation of foundation.
4Filling in foundation or plinth by fine sand in layers not exceeding 150 mm. as directed and consolidating same by through saturation with water ramming complete,including the cost of supply of sand.
5Supplying and laying Polythene Sheet (150gm / Sqmtr) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
6Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. Item 1, Page 14 of 315
7Cement concrete with graded stone ballast (40mm) excluding shuttering.a) In ground floor and foundation. 6:3:1 proportion pakur variety.
825mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer"s specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). [Note: - Waterproofing as per item 9, polymer based paint as per item 8 (a) of subhead C of Section (C)
9Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.
10Brick work with 1st class bricks in cement mortar (6:1) a) In foundation and plinth.
11b) In super structure Ground Floor
121st Floor
13125mm thick brick work with 1st. class bricks in cement mortar (4:1). a) In ground floor.It 16 & P16 of 31
141st Floor
152nd Floor
16Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety In Ground Floor
171st Floor
182nd Floor
19Reinforcements for reinforced concrete work in all sorts of structuresincluding distribution bars, stirrups, bindersetc. including supply ofrods,initial straightening and removal of loose rust(if necessary), cutting torequisite length, hookingandbending to correct shape,placing inproperpositionandbinding with 16G black annealed wireatevery inter-section, (a) For works in foundation, basement and uptoroof of ground floor / upto 4m. (i) JSW/JSPL/SHYAM (Tor Steel/ HYSD)
201st Floor
212nd Floor
22Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor).(i) 25 mm to 30 mm shuttering without staging in foundation
23(b) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work In Ground Floor
241st Floor
252nd Floor
26Plaster ( to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints or roughening of concrete surface, including throating, nosing and drip course where necessary .In ground floor. A) With 6:1 cement mortar. a) Inside wall20 mm thick plaster In ground floor
27In First Floor
28In Second Floor Mumpty Room
29b) Out side Wall, 15mm th. Ground Floor
301st Floor
312nd Floor Mumpty Room with Parapet wall
32Inside wall of 1500 lits. Capacity water tank 15 mm thick (1:4) cement plaster
33B)10mm th celling plaster (4:1) Ground Floor
341st Floor
352nd Floor Mumpty Room
36Neat cement punning wall, dado window sills, floor, drain etc.
37Supplying, fitting & fixing MS clamp for fixing door and window frame made of flat bent bar, end bifurcated, fixed in cement concrete with stone chips (4:2:1)afitted andfixed ompleteas per direction. 40mm x 6mm x 125 mm length. (Cost of cement concrete will be paid separately)
38Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals).. (d) Sal : Local. (i) Ground Floor
39(ii) First Floor
40Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including, fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor. (b) 32 mm thick shutters (single leaf). (i) Ground Floor
41(ii) First Floor
42Supplying, fitting & fixing of partly glazed partly panelled or fully glazed single leaf Aluminium swing door of all aluminium sections viz door frame ( top and side frame), shutter( top rail, bottom rail, lock rail, door vertical) , glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868- 1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws etc. including labour charges for fitting and fixing of aluminium door with door spring,/aluminium hinges, glass / Panel board all complete as per architectural drawings and direction of Engineer-incharge. ( Excluding cost of glass/ panel board, door spring/ Al hinges, door closer, door stoper, handle, tower bolt and locking arrangment etc) 10-12 Micron thickness Annodizing film Natural white [Note : for estimate purpose construction wing may consider weight of Aluminium door @ 9.0 Kg per Sq.M]
43Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. vi) 6mm thick coloured / tinted / smoke glass. In Ground Floor
44In First Floor
45Providing, fitting and fixing in position, medium density fibre board conforming to IS: 12406-1988 for plain and IS: 14587-1998 for prelaminated made of wood fibre bonded with Urea formaldehyde for interior grade and Phenol Formaldehyde for exterior grade conforming to per IS:848-1974 as per approved make and brand as per direction of Engineer-in-Charge. In Ground Floor (C) Both side decorative lamination (II) Interior Grade (i) 8mm
46In First Floor
47(A) Supplying Aluminium casted body hydraulic door closer as per I.S.I.
48(C) Supplying Heavy Duty Aluminium Handle (EBCO Type) (Natural White)
49(a) Supplying "Godrej" mortice lock chromium plated with latch and keys 4 levers, including fitting and fixing complete.
50(ii) Door stopper (Anodised aluminium)
51Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). (A) In 10-12 Micron thickness Annodizing film I) Natural white g) Fixed glazing. i) Top, bottom and side member.
52ii) Mullion.
53Supplying, Fitting & Fixing Factory made P.V.C. door frame of size 50 mmx47 mm with a wall thickness of 5 mm, made out of extruded 5 mm, PVC sheet miter cut at two corners and joined with two nos of 1.5 mm long brackets of 15 mm x15 mm M.S. square tube. The two vertical door profiles are to be reinforced with 19 mmx 19 mm M.S. Square tube of 19 gauge, weather seal to be provided through out the frame. The door frame shall be fixed with the wall using 65/100 mm long M.S. Screws through the frame by using P.V.C fasteners. A minimum of 4 Nos of screws to be provided for each vertical member and minimum 2 Nos for horizontal member etc. complete as per Manufacturer?s specification and direction of Engineer-in-Charge.
54Supplying, Fitting & Fixing 30 mm thick Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of approved make and manufacture, M.S. frame covered with 5 mm th. heat moulded PVC “C” channel of size 30 mm th, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on either sides forming styles; and 5 mm th. 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm tapered in 45 degree on the inner side to form top & bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel with 10 mm (5 mmx2) th.,20 mm wide cross PVC sheet as gap insert for top rail and bottom rail. Paneling of 5 mm th. both side PVC sheet to be fitted in the M.S. frame welded/sealed to the styles &rails with 7 mm (5 mm+2 mm) th.x15 mm wide PVC sheet beading on inner side and joined together with solvent cement adhesive. An additional 5 mm th. PVC strip of 20 mm which is to be stuck on the interior side of the “C” channel using PVC solvent adhesive etc. complete excluding all necessary hardwares as perdirection of Engineer-in-Charge. In ground floor.
55In First Floor
56Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. (a) M.S. integrated grill as per approved design integrated with steel window or ventilator, joints continuously welded with M.S. flats and bars. i)In Ground Floor
57In First Floor
58(b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only]i)In Ground Floor (W2)
59In First Floor (W2)
60Supplying,fitting & fixing of 2-Track / 3-Track Aluminium sliding Window of all Aluminium sections viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodised conforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film(2-Track) [Note : for estimate purpose construction wing may consider weight of 2-track Aluminium window @ 5.5 Kg per Sqmtrand 3-track Aluminium window @ 6.5 Kg per Sq.M]
61Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. a)75mm x 47mm x 1.70mm
62Iron Socket Bolt of approved quality fitted and fixed complete. i) 150 mm long x 10 mm dia
63i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting. (c) 300mm long.
64Anodised aliminium D-type handle of approved quality manufactured fromextruded section conforming to I.S. specification (I.S. 230/72) fitted and fixedcomplete: (b) With round base: (iv) 150 mm grip x 10 mm dia rod.
65M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.Grill weighing 10 kg/sq m to16 kg/m2 SOR, PWD, 3rd Corrigenda, P- 91, I-10 In Ground Floor
66In First Floor
67In Second Floor
68Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both+B151 faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials.
69Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete.In ground floor. In Ground Floor
70In First Floor
71Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) In Ground Floor
72In First Floor
73In Second Floor
74Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer"s specification) including cleaning and smoothning of surface. Two Coats In Ground Floor
751st Floor
762nd Floor
77Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer"s specification and as per direction of the EIC. In Ground Floor: (b) Two Coats In Ground Floor
781st Floor
792nd Floor
80Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer"s specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. a) Normal Acrylic Emulsion Ground Floor SOR, PWD P-197, I-17
81First Floor
82Second Floor
83(a) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
84b) Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.
85Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary:With super gloss (hi-gloss)-With any shade except white. a) On timber or plastered surface Two Coats
86b) On Steel surface Two Coats
87Supplying, fitting and fixing UPVC down pipes A type and fittings conforming to IS 13592-1992with necessary clamps nails including making holes in walls, etc. and cutting trenches in any soil, through masonry concrete structure etc. if necessary and mending good damages including jointing with jointing materials ( Spun yarn, valamoid / bitumen / M. seal etc.) complete. i) UPVC Pipe 110 mm dia
88ii) UPVC Bend 87.5 degree 110 mm dia
89iii) UPVC Shoe 110 mm
90Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sqmtr (a)(b) Area of each tile above 0.09 Sq.m (i) Coloured decorative In Ground Floor
91In First Floor
92(B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sqmtr (a) (b) Area of each tile above 0.09 Sq.m (ii) Other than Coloured decorative including white In Ground Floor
93In First Floor
94Supplying and laying chequered tiles of any shade & of approved quality with (1:1½:3) cement concrete laid in panels or patterns as directed in pavement, footpath etc. including necessary underlay 25 mm thick [avg] cement mortar (1:3) complete in all respect with all labour and materials. [Using cement slurry @ 4.4 kg/Sq.m at back side and @2.4 kg/Sq.m for joint filling] Red Variety (i) 25 mm. thick
95Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer"s specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the cont (I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment.(B) Light Colour In Ground Floor
96In First Floor
97Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement
98Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stone slab in wall, dado in 15 mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold the stone properly by brass / copper hooks including pointing in cement mortar (1:2) (1 cement : 2 marble dust) with admixture of pigments matching the stone shade, including grinding and polishing all complete as per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging curing complete. [Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m] In Ground Floor
99In First Floor
100SANITARY & PLUMBING WORKS Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. (i) CPVC Pipes Class-1, SDR-11 a) For Exposed Work 20 MM DIA
10132 MM DIA
10240 MM DIA
103(b) For Concealed Work15 mm Dia
104Supplying, fitting and fixing Peet"s valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. markng with fittings(tested to 21 kg/sq.cm.). 20 MM DIA
10532 MM DIA
10640 MM DIA
107Supplying, fitting and fixing bib cock or stop cock. P.W.D./S & P/ P-6 / It. No-7 a) Chromium plated Bib Cock short with wall flange with aerator (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand)
108b) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar brand).
109c) Chromium plated angular Stop Cock with wall flange (Equivalent to Code No. 5053 & Model - Florentine of Jaquar or similar brand).
110Suppling,fitting & fixing E.W.C in white glazed vitreous china ware of approved make supplied fittied complete in position with necessary bolts nuts.etc. a)with "P" trap
111Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws supplied, fitted and fixed complete. (a) E.W.C. (ii) Plastic (hallow type) white
112Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete. i) Polythene Flush Pipe
113Supplying, fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. (iv)600 mm long
114Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.(ii) 550 mm X 400 mm size
115Supplying, fitting and fixing pedestal of approved make for wash basin (white)
116Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. (a) Sink only (i) 530 mm X 430 mm x 180 mm
117Supplying, fitting and fixing pillar cock of approved make. a) (i) CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model - Tropical / Sumthing Special of ESSCO or similar brand).
118Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I, specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm
119Supplying, fitting and fixing towel rail with two brackets.(a) C.P. over brass (ii)25 mm dia. and 600 mm long
120Supplying, fitting and fixing soap holder. (b) Fibre glass
121Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) – Multilayer (b) 1000 litre capacity
122Labour for hoisting plastic water storage tank.(i) Upto 1500 litre capacity.(a) Upto 1st story from G.L.
123b) Extra for each additional story
124Labour for punching hole in plastic water storage tank upto 50 mm dia.
125Supplying, fitting and fixing Flat back urinal (half stall urinal) in whitevitreous chinaware of approved make supplied, fitted and fixed in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete. (ii) 470 mm X 280 mm X 340 mm
126Supplying, fitting and fixing urinal flush pipe fittings of approved brand. (a) C.P. urinal flush pipe fittings range of one
127Supplying, fitting and fixing Squating plate with integral flushing in white vitreous chinaware of approved make in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid seperately). (i)450 mm X 350 mm
128Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit,providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved makesupplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. i) With Pakur variety. (JSW/JSPL/SHYAM)
129Construction of septic tank of different capacities as per approved drawing with 1stclass brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manholecover(heavy type)of approved make supplied, fitted and fixed in the 100mm thickR.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1)with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc....(ii) For 20 users A) With Pakur variety. (JSW/JSPL/SHYAM)
130Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having ISO mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement concrete...... (JSW/JSPL/SHYAM)
131Cutting hole through wall,roof or cornice and mending good all damages.
132Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (A) (i) Single Socketed 3 Meter Length (a) 75 mm
133(b) 110 mm
134Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(B) Fittings(i) Coupler (a) 75 mm
135(b) 110 mm
136(ii) Plain Tee (a) 75 mm
137(ii) Plain Tee (b) 110 mm
138(iii) Door Tee (b) 110 mm
139vi) Door Y (LH) & (RH)(b) 110 mm
140x) Bend 87.5º(a) 75 mm
141x) Bend 87.5º (b) 110 mm
142xi) Door Bend (T.S.) 110 mm
143xiv) Cross Tee with Door (a) 75 mm
144xiv) Cross Tee with Door (b) 110 mm
145xv) Vent Cowl110 mm
146xvi) Pipe Clip (a) 75 mm
147xvi) Pipe Clip (b) 110 mm
148xviii) W.C. Connector (450 mm long) W / lipring (a) 75 mm
149xxiii) 110/110 S Trap (a) 75 mm
150xxvi) Reducer 110 X 75 mm(a) 75 mm
151xxvii) Reducing Tee (110 X 75 mm)(a) 75 mm
152xIix) Door Gasket( b)110 mm
153Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor)... (A) Above ground (a) 75 mm
154(b) 110 mm
155Supplying,fitting and fixing with cement jointing (3:1) salt glazed stoneware pipe including excavation of earth upto 1.50 metre depth in all sorts of soil both mixed or unmixed and refilling (but excluding concreting at bottom and sides). (iv) 100 mm
156Supplying, fitting and fixing C.I. round grating. 150 mm dia
157Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
158ELECTRIFICATION WORK Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.63 Amp Make L&T [Page D-3, It.-4 (a)]
159Supplying and fixing Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc 63 Amp 415VFP MakeHavels [Page D-1, It.-2(b)]
160Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – (As per Drawing no. 470 of PWD Specification Book – May 1991) Dimension of Al. Bars [85mm long] - 4 x 25 x 5 mm Dimension of Sheet Metal Box - 500x150mm415 V, 100/125 A [Page D-12, It.-19(b)]
161Supplying and fixing Sheet steel Main Switches on flat iron frame on wall15/16 Amp 240 V DP with fuse on L& N Make Havells [Page D-1, It.-1(a)]
162Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachmentMake Legrand 6 way Enclosure (607716) along with a) FP S&F 415 V, 63 Amp MCB Isolator necessary connection. b) SP MCB 240V, 6-32 Amp-----18 Nos.Rate = {3504+845+(18*190)} = 7769 [Page D-10, It.-14 + D-5, It.-6 + D-6, It.-7 ]
163a) Supplying and fixing double-door (2+6) way SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Enclosure Enclosure (DHDPSNODRW06)(Havels make ) [Page D-9, It.-13]
164Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection SP MCB6-32 A(Legrand make) (Page D-6, It. - 7)
165Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. 40A DP ISOLATOR (Havels make) [Page D-5, It.-6]
166Distribution wiring in 1.1 KV single core stranded "FR"PVC insulated & unsheathed copper wire (Brandapproved by EIC) in 20mm size PVC rigid conduit "FR" (Precision make) incl. necy. fittings as required (a)2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
167(b)2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC [For power plug & pump motor connection]
168(C)2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [For out door fitting] [Page E-1 item 14(a)]
169Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting. [Page I-2 item no16(a)]
170Supplying of 1.1 KV. Grade PVC insulated Conductor of following cables (make: Polycab/ Gloster/Havells/) 10 sq mm 2 core [UD & MA Page-11 Item- c/1]
171Supplying of 1.1 KV. Grade PVC insulated Conductor of following cables (make: Polycab/ Gloster/Havells/) 16 sq mm 4 core [UD & MA Page-11 Item- f/1]
172Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4 Core 35 sq.mm. [Page F-4, 7 (C)]
173Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 2 Core 10 sq.mm. [Page F-4, 7 (c)]
174Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4 Core 16 sq.mm. [Page F-4, 7 (c)]
175Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 2 Core 10 sq.mm. [Page F-5, 8 (b) (xv)]
176Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 3.5 Core 35 sq.mm. [Page F-5, 8 (b) (xv)]
177Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 4 Core 16 sq.mm. [Page F-5, 8 (b) (iii),(xiii)]
178Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required [Page G-2, 4 (b)]
179Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages (v) No. 12 SWG [Page G-2, 5 (a) (v)]
180Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By TATA-Medium GI pipe [Page G-1, 2 (a)]
181Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded "FR" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish. 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC i)Average run 6 mtr [Page E-20 Item No.- 1 ]
182Engraving the deptt. number with 10 mm lettering on the body of fan upto 10 letters incl. hifen, stroke or stop. [Page C-3 item 24(a)]
183Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded "FR" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC [page E-20 item no 3] a) On Board
184b) Average run 4.5 mtr.
185Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. a)Blank Plate for modular box-----1no Rate = (456+20 = 476) [8 for power plug 1 for pump] [Page E-18, 9(b) & Page K-2, 99 ]
186Supplying & Delivery at site LED batten Tube light fitting (Philips make, model - BN021C LED20S PSU CW GR S2 [KMDA Vetted]
187Fixing only Single/twin fluorescent light fitting complete with all accessories directly on wall/Celling by screws etc. [Page C-2, It. No. 14(a)]
188Supply & delivery at site 15 watt LED Bulb (Philips /Havells make model-New Adore 15W E27 CDL Ball Lamp), as per direction of EIC. (Analysed rate) [KMDA Vetted]
189Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling. [Page D-13, It. No. 22]
190Fixing only 15 W LED lamp [Page C-2, It. No. 11]
191Supply and delivery of Ceilling fan 48” Sweep a) Crompton Greaves make [UD & MA page- 23 item no-70]
192Fixing only Ceiling Fan Complete with Blades . Regulator ,Canopy ,Fort Rubber Bush etc. Incl. S & F. 1/1.40 PBC Standered wire & making necessary connection as refquired by 2x1.5 sqmm flexible copper wire [Page C-3, It. No.- 21(a)]
193Supply & Fixing 60 Wt. Electronics Step-Socket type fan regulator (Anchor Make) on switch board after cutting Bakelite tip cover as per direction of EIC [E-6, 18 (b)]
194Supply and delivery of 230V,50Hz Heavy duty Metal (9")exhuast fan. [UD & MA Page-14 item no.-6]
195Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 23 cm Al Exhaust fan (9") [Page D-14 item 32(b)]
196Supply and delivery of 230V,50Hz Heavy duty Metal (12")exhuast fan. [UD & MA Page-14 item no.-5]
197Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 30 cm Al Exhaust fan (12") [Page D-14 item 32(b)]
198Fixing Exhaust Fan after making Hole in wall & making good damages & smooth cement finish etc. as praticable as possibe & prividing necessary length of insulated wire & making connection for Exhaust of dia. (Page C-4, It - 28 (a) & (b)) a) 23 cm.(9")
199b) 30 cm.(12")
200Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (for future provision of AC machines) [Page E-19, 17]
201Supplying and delivery at site 220-240V 36 Watt LED Outdoor type luminiares (Make:- Philips Model No- BRP046 LED 36W MR SI PSU) [Approved Rate]
202Fixing only Floodlight fittings on top of masonary structure by 3 Nos. 10 mm dia x 87 mm long rag bolts, nuts & double washers complete either 37 mm x 10 mm MS flat support/or by other means as required(Page C3, It. No. 20(b)
203Supply and Fixing of 2 mm Polyvinyl glow sign board madeof 22 SWG GI sheet box with 5”X12” aluminum channel for fixing the vinyl board after necessary cutting the letter as required & s\f LED tube light fittings along with all accessories. [8 x 4 ]+[4 x 2]= 40 [UD & MA Page- 14 item no 4]
204Supply, and fixing of 1HP self priming pump : Make KSB,peribloc-1
205Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board. [Page D-13, It. 20(a)]
206G.S.T. @ 18.00%
207Labour Welfare CESS @ 1.00 %
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail