Tender For Replacement Against Scrapping Of Life Expired Electrical Distribution Board Mcbs Main And Sub Main Circuit Wiring And Led Fittings At Gmt Bldg Telecom Bhawan Nagpur, nagpur-Maharashtra

Bharat Sanchar Nigam Limited-BSNL has published Tender For Replacement Against Scrapping Of Life Expired Electrical Distribution Board Mcbs Main And Sub Main Circuit Wiring And Led Fittings At Gmt Bldg Telecom Bhawan Nagpur. Submission Date for this Tender is 14-12-2022. Electrification Work Tenders in nagpur Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

35051922
Tender For Replacement Against Scrapping Of Life Expired Electrical Distribution Board Mcbs Main And Sub Main Circuit Wiring And Led Fittings At Gmt Bldg Telecom Bhawan Nagpur
Open Tender
Indian
Maharashtra
nagpur
14-12-2022

Tender Details

Replacement Against Scrapping Of Life Expired Electrical Distribution Board Mcbs Main And Sub Main Circuit Wiring And Led Fittings At Gmt Bldg Telecom Bhawan Nagpur

Key Value

Document Fees
INR 590 /-
EMD
INR 9963.0 /-
Tender Value
INR 4.98 Lakhs /-

BOQ Items

Name of Work: - Replacement (Against scrapping) of life expired Electrical Distribution Board, MCBs, Main & Sub Maincircuit wiring and LED fittings at GMT Bldg. Telecom Bhawan , Nagpur.
Sl. No. Item Description
1Dismantling ofexisting burnt out TPN SFUs ( 8nos.),Distribution Panels with kit kat fuses ( 06 Nos) , TPN DB 12 way horizontal model ( 05 Nos.) , SPN DB 12 Ways (05 Nos) , Main & sub main wiring with MS conduit at various floorsfrom rising main duct, and making good the damages including minor civil works etc complete as required.
2Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs as outgoing & MCCB as Incomer (without MCCB & MCBs) on existing MS angle frame etc complete as required
3i) 8 way , (I/C MCCB & O/G8+8+8), Double door
4Supplying and fixing Cable End Box (Loose Wire Box) tosuit size and depth of existing TPN Vertical MCB Distribution Board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. at Outgoing of DBas required.( Same make of MCB & DB) (CEB-VTPN Double Door, MCCB Incomer )
5Providing and fixing following rating and breaking capacity and 4 pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required in existing metal sheet steel enclosurewith suitable adoptor box if required etc complete as required.
6i) 100 A, (30KA),4P MCCB
7ii) 125 A, (36 KA), 4P MCCB
8iii) 200 A, ( 36 KA) 4 Pole MCCB
9Supplying and fixing sheet steel enclosure box for accomodating 200 A MCCB including its accessesories such as spreade terminal & Rotary handle etc complete as required
10Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
11i)8 way , Double Door
12ii) 12 way , DoubleDoor
13Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
14Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
15i)Single pole
16ii)Double pole
17iii)Triple Pole
18Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required
19i)2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
20ii)2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
21iii)2 X 4 sq. mm + 1 X 4 sq. mm earth wire
22iv)2 X 6 sq. mm + 1 X 6 sq. mm earth wire
23Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required.
24i)3 X 1.5 sq. mm
25ii)3 X 2.5 sq. mm
26iii)3 X 4 sq. mm
27iv)3 X 6 sq. mm
28Suppying and fixing following modular switch/ socket on existing modular plate & switch box including connections but excluding modular plate etc. as required.
29i)5/6A Switch
30Supplying and fixing following size / modules, GI Box alongwith modular base & cover plate for modular switches in recess etc. as required.
31i)12 Module ( 200mm x 150 mm)
32Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.
33i)12 Module
34Suppying and Fixing metal Box of180 mm x 100 mm x 60 mm deep ( nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 Amp socket out let & 15/16 Amp piano type switch, connections, painting etc. as required.
35Supplying and laying ofPVC insulated3 x 2.5 Sq.mm copper conductor unarmoured cableof 1.1 KV grade ( ISI mark) directly on the surface of wall/ trayincluding providing and fixing clamps etc as required .( For providing supply to above power points )
36Replacement of existing square typeCFL 2 x18 watt faulty fittings withenergy efficeint recess type 36 Watts LEDlight fittings ofsize 600 mm x 600 mmin exisiting false ceiling/ panel with suitable metal chain suspension including extension of point wiring up to fitting with 3 core 1.5 Sq. mm copper conductorflexible wire etc complete as required. ( Make : Syska, Wipro, Crompton etc.)
37Providing and fixing 8 SWG Dia G.I. wire on surface or in recess for loop earthing as required
38Supply and laying offollowing sizes PVC sheathedpower cable of 1.1 KV grade of copperconductor multistanded flexible cable in flexibleetc complete as required.( ISI Mark Cable) ( Note:cable is to be laid for interconnection between rising main bus bar to MCCB incomer.
39i)Copper conductor multistranded flexible cable 4 x 16 Sq.mm
40ii)Copper conductor multistranded flexible cable 4 x 25 Sq.mm
41Supply of flexible GI pipe of suitable diameter with glands at both ends for laying above flexible cable through it etc complete as required.
42Supplying and making end terminations with copper crimpping lugs forfollowing sizes cables etc complete as required
43i)Copperconductor multistanded flexible cableof size 4 x 16 sq.mm.
44i)Copperconductor multistanded flexible cableof size 4 x 25 sq.mm.
45Credit fordismantaled burnt out TPN SFUs ( 8nos.),Distribution Panels with kit kat fuses ( 06 Nos) , TPN DB 12 way horizontal model ( 05 Nos.) , SPN DB 12 Ways (05 Nos) , Main & sub main wiring faulty square type CFL fittings etc complete as required.
Disclaimer :