Tender For Comprehensive Maint And Petty Repair Of Internal Wiring Electrical Fittings And Fixtures And Fans In E F G H And J Areas At Naval Base Kochi Under Ge Nw Kochi, kochi-Kerala

Military Engineer Services-MES has published Tender For Comprehensive Maint And Petty Repair Of Internal Wiring Electrical Fittings And Fixtures And Fans In E F G H And J Areas At Naval Base Kochi Under Ge Nw Kochi. Submission Date for this Tender is 21-12-2022. Electrification Work Tenders in kochi Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

35010155
Corrigendum : Tender For Comprehensive Maint And Petty Repair Of Internal Wiring Electrical Fittings And Fixtures And Fans In E F G H And J Areas At Naval Base Kochi Under Ge Nw Kochi
Open Tender
Indian
Kerala
kochi
21-12-2022

Tender Details

Comprehensive Maintenance And Petty Repair Of Internal Wiring Electrical Fittings And Fixtures And Fans In E F G H And J Areas At Naval Base Kochi Under Ge Nw Kochi As Per Boq And Tender Document

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Dec-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 21-12-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 49.90 Lakhs /-

BOQ Items

NAME OF WORK: COMPREHENSIVE MAINT AND PETTY REPAIR OF INTERNAL WIRING, ELECTRICAL FITTINGS & FIXTURES AND FANS IN "E", "F", "G", "H" AND "J" AREAS AT NAVAL BASE KOCHI UNDER GE (NW) KOCHI
Sl. No. Item Description
1Taking down Copper /aluminium point wiring (light ,fan ,socket ,bell, power point ) complete fitting such as switches ,ceiling roses ,pendants, regulators, sockets ,light fitting any type, building security lightremoving materials to store for keeping in safe custody fortaking creditto match with existing surface complete all as specified and directed.
2M&L Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with 1.5 sqmm nominal cross sectional area, copper conductor unsheathed FRLSH cable 1100 Volts grade includingPVC casing and caping and connected accessories ISI markedincluding PVC switch boxes or terminal boxes with cover plate and including 1.5 Sqmm nominal cross sectional area PVC insulated copper conductor unsheathed FRLS cable single core multistranded cable as earth continuity wire for one light / fan point controlled by one switch complete all as specified and as directed.
3All as per item No 2 here-in-before but for 5 pin 5 Amps socket outlet point on independent board.
4All as per item No 2 here-in-before but for 5 pin 5 Amps socket outlet point on sameboard.
5All as per item No 2 here-in-before but using 2.5 sqmm copper conductor cable (multistranded) PVC insulated FRLS and unsheathed cableand 2.5 sqmm copper conductor cable (multistranded) PVC insulated FRLS and unsheathed cable earthwire with terminal box of suitable size complete all as specified.
6All as per item No 2 above but with 4 Sqmm copper conductor including 4.0 Sqmm copper cable on earth wire for sheet metal enclosure
7S&F switch piano flush type single pole one way 6 Amp one way complete all as specified and as directed.
8S&F switch piano flush type single pole one way 16 Amp complete all as specified and as directed
9S&Fsocket outlet 5 Amps, 5 pin, 2 in 1 complete all as specified and directed
10S&F socket outlet multipurpose 5 and 16 Amps, 5 pin, 2 in 1 complete all as specified
11S&Fceiling rose surface bakelite 65 x 50 mm, 3 terminals complete all as specified
12S&F in repair,bell push flush type 5 Amps single pole complete all as specified and as directed.
13S&F in repair,electric bell, AC 230Voltsingle pole complete all as specified and as directed
14S&F in repair,switch piano flush type single pole one way 5 Amp one way complete all as specified and as directed.
15S&F in repair, switch piano flush type single pole one way 15 Amp complete all as specified and as directed
16S&F in repair, socket outlet 5 Amps, 5 pin, 2 in 1 complete all as specified and directed
17S&F in repair,socket outlet multipurpose 5 and 15 Amps, 5 pin, 2 in 1 complete all as specified
18S&F in repair, switch socket combination 5 Amps, 5 pin 2 in 1 , complete all as specified
19S&F in repair, switch socket combination multipurpose 5& 15 Amps, 5 pin, 2 in 1 complete all as specified
20S&F in repairfan regulator electronic step type 100 W, 250 Volts complete all as specified
21S&F in repair, capacitor for ceiling fans, 230 volts, 2.5 MFD including necessary solderingcomplete all as specified andas directed
22S&F in repair,lamp holder ,PVC / poly carbonate type withback plate suitable for batten fittings,all as specified and directed
23S&F in repair, ceiling rose surface Bakelite 65 x 50 mm, 3 terminals complete all as specified and as directed
24S&F in repair, Switch socket combination 2 in 1, 3 pin, 5A/16A, 5 in 1 flush type with fuse & neon incator complete all as specified and as directed.
25M&Lin repairsub main wiringon wall/ceiling with 4 runs of 6 Sqmm single core PVC cable as per IS 694-1990(third revision)insulated unsheathedmultistranded copper conductor FRLSHcable 1100 Volts grade drawn throughin PVC cassing capping / PVC conduit / existing concealed conduitwith all accessories such as Tees, elbows, junction box etc.as required of not less than 20 mm diaand 1 run of 6 Sqmmsingle core PVC insulated unsheathed1100 Volts grade, multistranded copper conductor FRLSH cableas earth continuity conductorand connecting to existing earth dollywith suitable size thimbleand making good the disturbed surface to match with the existing including taking down of old sub main wiring ,all as specified andas directed. Note:- 5 runs of 6 Sqmm cable and one run of PVC cassingand cappingwith accesories shall bemeasured as one unit.
26All as per item No 25 here-inbefore but 4 runs of 10sqmm single core FRLSHcopper conductor and 1 run of 10 sqmm conductor for earthing. Note:-5 runs of 10 Sqmm cable and one run of PVC casing and cappingwith accesories shall bemeasured as one unit.
27All as per item No 25 here-inbefore but 2 runs of 6 sqmm single core FRLSHcopper conductor and 1 run of 6 sqmm conductor for earthing . Note:-3 runs of 6 Sqmm cable and one run of PVC casing and cappingwith accesories shall bemeasured as one unit.
28All as per item No 25 here-in-before but 2 runs of 4 sq mm single core FRLSHcopper conductor and 1 run of 4 sqmm conductor for earthing. Note :- 3 runs of 4 Sqmm cableand one run of PVC PVC and cappingwith accesories shall bemeasured as one unit.
29S&F in repair Sheet Metal Enclosure forMCB DB,TPN, 8 ways, double door, 415 Volts, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified
30S&F in repair Sheet Metal Enclosure forMCB DB,TPN, 6 ways, double door, 415 Volts, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified
31S&F in repair Sheet Metal Enclosure forMCB DB,SPN, 8 ways, double door, 240 Volts, with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified
32S&F in repair Sheet Metal Enclosure forMCB DB,SPN, 4 ways, double door, 240 Volts,with 200 Amps rated bus bar, having IP-43 protection including taking down old DB complete all as specified.
33S&F in repair MCB, TPN,63 Amps, 415 Volt,B curve, having breaking capacity 10 kA, complete all as specified.
34S&F in repair MCB, TPN,100 Amps, 415 Volt,B curve, having breaking capacity 10 kA, complete all as specified.
35S&F in repair MCB, TP,63 Amps, 415 Volt,B curve, having breaking capacity 10 kA, complete all as specified.
36S&F in repair MCB, TP,100 Amps, 415 Volt,B curve, having breaking capacity 10 kA, complete all as specified.
37S&F in repair MCB, TPN,40 Amps, 415 Volt,B curve, having breaking capacity 10 kA, complete all as specified.
38S&F in repair MCB, SPN,32-40 Amps, 415 Volt,B curve, having breaking capacity 10 kA, complete all as specified.
39S&F in repair MCB, SP,6-40 Amps, 240 Volt,B curve,having breaking capacity 10 kA, complete all as specified.
40S&F in repair MCCB,4 Pole, 100 Amps, 415 Volts, having breaking capacity 25 kA, thermal-magnetic release,including taking down old MCCB complete all as specified.
41S&F in repairMCCB,4 Pole, 63 Amps, 415 Volts, having breaking capacity 25 kA, thermal-magnetic release, including taking down old MCCB complete all as specified.
42S&F in repairMCCB,4 Pole, 160 Amps, 415 Volts, having breaking capacity 25 kA, thermal-magnetic release, including taking down old MCCB complete all as specified.
43S&F in repairMCCB,4 Pole, 200 Amps, 415 Volts, having breaking capacity 25 kA, thermal-magnetic release, including taking down old MCCB complete all as specified.
44S&F in repairMCCB,4 Pole, 250 Amps, 415 Volts, having breaking capacity 25 kA, thermal-magnetic release, including taking down old MCCB complete all as specified.
45S&F in repairMCCB,3 Pole, 63 Amps, 415 Volts, having breaking capacity 25 kA, thermal-magnetic release, including taking down old MCCB complete all as specified.
46S&F in repairMCCB,3 Pole, 100 Amps, 415 Volts, having breaking capacity 25 kA, thermal-magnetic release, including taking down old MCCB complete all as specified.
47S&F in repairMCCB,3 Pole, 160 Amps, 415 Volts, having breaking capacity 25 kA, thermal-magnetic release, including taking down old MCCB complete all as specified.
48S&F in repairMCCB,3 Pole, 200 Amps, 415 Volts, having breaking capacity 25 kA, thermal-magnetic release, including taking down old MCCB complete all as specified.
49S&F in repairMCCB,3 Pole, 250 Amps, 415 Volts, having breaking capacity 25 kA, thermal-magnetic release, including taking down old MCCB complete all as specified.
50S&F in repair 36 Watt LED Building Security light Industrialwith PDC housing having IP 65 protection including taking old light fitting completeall as specified.
51S&F in repair Regal Batten for LED tube lights, both side connection type and LED tube rod 1 x 20 Watt, both side connection all as specified and as directed. Make of batten : Havells/Crompton/ Wipro
52S&F in repair Blaze highbay LED light 150 Watt ,240 volt , all as specified and directed. Make:Luker / Philips/ Surya
53S&F in repair 50 WattLEDFlood Lighthaving IP-66 protection, pressure die cast aluminium housing, high luminious efficacy and high power complete all as specified. Make Luker / Havells / Philips
54S&F in repair LED tube light 1x20 W both side connection type all as specified and directedin repair of conventional tube rods, ballast etc. Make Havells /Surya/ Wipro/ Luker
55S&F in repair 18 watt LED PLL lampby disconnecting and removingthe old choke, starter from the existing fitting with necessary internal wiring from holder to terminal box inside the fitting completeall as specified Make : Havells / Crompton/ Surya
56S&F in repair 12/15 Watt recessed mounted, round/square shaped LED down lighter with high luminous LED for indoor applicationwith all accessories and connection to the electric circuit including taking down old light fittingcomplete all as specified. Make Luker / Crompton/ Surya
57S&F in repair 12 to 15 watt surface mounted LED Square down lighterwith high luminous LED for indoor applicationwith all accessories and connection to the electric circuit including taking down old light fittingcomplete all as specified. Make : Luker / Crompton/Surya
58S&F in repairLED aviation obstructionlight luminaires, comprising ofaluminium housing LED bulb , with polycarbnate enclousure including taking down old light fitting complete all as specified. Make Bajaj/ Crompton
59S&F in repair 36 Watt LED recessed mounted panel lights (600x600mm size) luminaires, comprising ofaluminium housingwith polycarbonate enclousure including taking down old light fitting complete all as specified.Make : Luker / Crompton/Surya
60M & L in repairsEarthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanized iron wire 4mm diaas earthup to 7.5 mdistance and connected by means of bolts, nuts, checknuts and washers of galvanisediron or steel all shown in electric plate No. 3 of SSR Part-I connected to earthing test point all as specified or indicated including provision of necessary excavation and earth work in any type of soil, PCC pit , RCC cover 50 mm thick, reinforced with8 mm dia TMT barsboth ways @ 10 CM c/c ,20 mm bore medium grade watering pipe, water funnel, 15 mm bore GI light grade protection pipe, common salt, charcoal dust, returning, filling in of soil, removal of spoil to a distance not exceeding 50 mtr etc including testing on completion completeall as specified. Note :- The unit rate includes for protection pipe and earth lead upto 7.50 Mtr.
61M&L in repair aluminium strip 25 x 3 mm with porcelain insulators,saddles and fixing screws etc for roof conductor and down conductor above ground all as specified and directed.
62M&L in repair air termination single pointed aluminium rod 12mm dia and 300mm long all as specifed and directed.
63M&L for test point terminal block made of gunmetal of size 75x75x25mm drilled and screened including all fixing arrangements with hexagonal headed screws and taking down old ones complete all as specified.
64S&Fin repairPVC junction boxes for accommodating test point of lightening arrestor syntex make all as specified and diercted.
65Equipment and labour for testing of earth resistance of existing earthing oflightening arrestor of building /workshop/hanger /OTM etc at Naval Base Kochi .
66S&F in repair Modular Bell push 6A, 1module, complete all as specified.
67S&Fin repair Fan Regulator, modular electronic rotary,0-4 steps step type 100 Watt, 240 Volt50 Hz hum free 2 module of existing type & make. complete all as specified.
68S&Fin repair switch modular 6 Amps 240 Volts one way switch complete all as specified.
69S&Fin repair Socket 6 Amps AC 240 Volts 2/3 pin combined 2 modular type complete all as specified.
70S&Fin repair Socket6A/16 Amps-2/3 pin combined AC 240 Voltsmodular type complete all as specified.
71S&Fin repair Switchmodular type AC 240 volts 16 Amps one way complete all as specified.
72S&F in repair10 Watt LEDMirror Lamp,240V, surface mounted decorative mirror optic type with engineered plastic body and including tube rod and connected accessories includingprovisionof flexible copper wire from ceiling rose to light fitting terminal complete all as specified. Make : Luker / Crompton/Surya
73S&F in repair SPN enclosure withtwo pin and earth plug and socket complete with one SP MCB, 20 Amps having breaking capacity 10 kA,including taking down old unserviceable eath plug complete all as specified.
74M&L XLPE insulated heavy duty electric cables 10 sqmm 4corewith aluminium conductor, 1100 volts grade,including taking down oldunserviceable cable complete allas specified for the following sizes:
75M&L XLPE insulated heavy duty electric cables 16 sqmm 4corewith aluminium conductor, 1100 volts grade,including taking down oldunserviceable cable complete allas specified for the following sizes:
76M&L XLPE insulated heavy duty electric cables 25 sqmm 4corewith aluminium conductor, 1100 volts grade,including taking down oldunserviceable cable complete allas specified for the following sizes:
77Taking down existing ceiling fans of 1200 mm sweep of any make and removing to workshop for following repairs and refixing at same location/ other location as directed by Engineer-in-Charge:- (a) Opening & Strip cutting the winding of ceiling fans and re-winding with super enamelled copper wire of suitable/ existing size, with sleeves, heating, baking etc. and re-assembling the same. (b) Replacement of Ball bearings of suitable size. (c) Replacement of fan capacitor of suitable capacity. (d) Replacement of split pin, Nickel plated mild steel clamps, nuts, bolts washer suitable for any make & type ceiling fans (e)Provn ofRubber real insulator with clamps, bolt, nuts and split pin. (f) Provn of Screws of suitable size for blades & body. (g) Spray painting of the fan in colour as directed
78All as per item No. 77 above but for exhaust fan 250 to 450 mm sweep
79All as per item No 77 above but for flame proof exhaust fan of any sweep
80All as per item No. 77 above but metal body wall mounted fan of 450 to 600 mm sweep
81All as per item No. 77 above but Air circulators 600 to 900mm sweep
82Taking down existing PVC body wall mounting fans of any make / type & servicing complete including well cleaning, removing of rust, dust etc. replacing of motor of suitable type & capacity of any make complete and making good to working condition all as specified & directed.
83S&F in repair of PVC body exhaust fans complete 200/250mm sweep on the same location or where as directed by Engr-in-Charge. Make: Havells / Crompton / Usha
84M&Lfor repairs to existing flame proof tube light fittings & replacement of unserviceable tube rods after opening, removing the existing tube rods, ballasts etc. with LED tube rods of 1x20 Watt complete all as specified and as directed. Make : Havells/ Crompton/ Philips
85S&F in repair flame proof rotary switch 10 to 16 Amps complete all as specified and as directed.
86S&F in repair flame proof rotary switch 16 to 25 Amps complete all as specified and as directed.
87S&F in repair driver assembly for LED fittings (Indoor or Outdoor type) for light fittings (Street light, High Bay light, Flood light) from 30 to 150 Watt of any make and type with existing type driver assembly all as specified and as directed.
88S&F in repair for driver assembly suitable for 2 feet x 2 feet of 36/40 Watt ceiling fittings surface mounted / recess mounted (Indoor Or Outdoor type) of any make for suitable to the existing light fittings of any.
89S&F in repair surface type LED fittings 5/8 Watt round/ square type of existing make and type
90S&F in replacment of LED bulbs of obstruction light at any height complete all as specified and as directed.
91M&L for checking of ceiling fan stability/ tightness with fan hook /exhaust fan stability and make good by re-tightening of split pin / nut, bolt etc, checking loose connection in distribution boards, MCBs "E", "F", "G", "H" & "J" or other specified areas complete all as directedas per site requirement complete all as directed. Note:- (i) The cost of accessorieslike split pin, nuts, bolts, washers etc if any required shall be included in the quoted rate. The quoted rate shall inclusive of all labour and plants like ladder etc complete. (ii) The contractor shall maintain a register showing the location of fan/DB/MCB duly signed by the users for the service carried out. This register shall be produced while claiming payment. (iii) The checking of fans shall be carried out once in 6 months.
92Labour only for attending urgent nature of electrical complaints (within 3 hrs from intimation)like checking of existing electrical items for continuous electric supply including carrying out minor repairs such as checking of voltage calibration, checking of variation of R Y Bphase in LT panel/DBs ,changing of MCBs, small pieces of wires including connectionsetccarrying out repairs such as tightening of loosen electric connections, nuts, bolts, screws of switches, sockets, switch boards, making joints and covering with PVC tape, minor repairs toceiling fans / exhaust fans like repair of capacitors, cleaning and oiling etc. as required to make the electrical items/ appliances fully functionalat "E", "F", "G", "H" & "J" area during off hours (0900 Hrs morning to 1700 hrs evening) on all working days all as specified anddirected by Engineer-in-Charge.
93Labour only for attending urgent nature of electrical complaints (within 3 hrs from intimation)like checking of existing electrical items for continuous electric supply including carrying out minor repairs such as checking of voltage calibration, checking of variation of R Y Bphase in LT panel/DBs ,changing of MCBs, small pieces of wires including connectionsetccarrying out repairs such as tightening of loosen electric connections, nuts, bolts, screws of switches, sockets, switch boards, making joints and covering with PVC tape, minor repairs toceiling fans / exhaust fans like repair of capacitors, cleaning and oiling etc. as required to make the electrical items/ appliances fully functionalat "E", "F", "G", "H" & "J" area during off hours (1700 hrs evening to 0900 Hrs morning) on all working days all as specified anddirected by Engineer-in-Charge.
94Labour only for attending urgent nature of electrical complaints (within 3 hrs from intimation)like checking of existing electrical items for continuous electric supply including carrying out minor repairs such as checking of voltage calibration, checking of variation of R Y Bphase in LT panel/DBs ,changing of MCBs, small pieces of wires including connectionsetccarrying out repairs such as tightening of loosen electric connections, nuts, bolts, screws of switches, sockets, switch boards, making joints and covering with PVC tape, minor repairs toceiling fans / exhaust fans like repair of capacitors, cleaning and oiling etc. as required to make the electrical items/ appliances fully functionalat "E", "F", "G", "H" & "J" area during off days on Sunday and holiday days all as specified anddirected by Engineer-in-Charge.
95NOTE for item No.90, 91 & 92:- (i) The material and labour costrequired for taking down existing fitting / fixture and fixing of new item shall bemeasured and paid separately under relevant item. Additional labour charge required for immediate attendance of complaint only shall be quoted under this item. (ii)The technician employed by the contractor shall available on all working days. The quoted rate shall inclusive of all labour, transportation of material and tools. (iii) The contractor shall display contact number of technicians in "E" area at Naval Base to register users complaint. (iv) A penal recovery of Rs. 1000/hour/complaint shall be effected on contractor beyond 3 hrs. A register shall be maintained by contractor duly countersigned byConcerned JE & AGE with time of occurrence of defect and time of rectification and submitted for claiming payment.. (v) Number of complaints may vary day to day and shall be on required basis. Contractor shall quote their rates accordingly including all aspects like labours ,tool, transportation etc.
96Material, Labour, tools & equipments for re-fixing light fittings after minor repair at any location, height without the help of Crane etc. like Hangers, Workshops etc of any make / type of light fittings all as specified and directed.
97Taking down Wall mounting fan of metal body of any type & size and painting by spraying of existing colour including covers and re-fixing at specified and as directed location.
98Periodical servicing and maintenance (daily, weekly, fortnightly and monthly) of electric operated hanger door comprising of 3 phase, 415V, 5.5 KW/ 3 HP, 50 Hz IP 55 capacity induction motor of Make - Havells,3 HP VFD panel, connected with gearbox through chain, push button for forward/ reverse movement of the doors, relays, limit switches, contactors gear wheels, siren, ammeter and voltmeter, indicating lamps, various capacities ofMCBs and suitable connecting cable etc. complete all as specified and directed by Engineer-in-Charge. Location : INAS 550 - 10 Nos motors and connceting items.
99Notes for item No.97:- (a) All tools / plants / equipments required for maintenanace of Hanger Door shall be provided by the Contractor. (b) Cost of nut, bolt, washers, etc of suitable size as requiredshall be included in the quoted rate. (c) Any complaint of the Hanger Door shall be attended within 2 hoursfrom intimation, other wise a penal recovery of Rs. 2000/- per hour shall be effected. (d)Replacement / refilling of gear oil in gear boxes is deemed to be included in the scope of item. The cost of gear oil, grease, cotton waste etcshall be included in the quoted rate.
100S&F Electric motor 3 HP, 415 Volt, 50 Hz IP 55 protection suitable for operating Hanger Doors forward and reverse motion of same existing model (of Havells) including taking down old motor complete all as specified and directed
101Rewinding of Hanger Door electric motor obtained as per Sl No. 96 above including strip cutting, rewinding of the motor with super enamelled copper conductor of existing size and gauge including heating, baking, replacement of bearings etc and re-assembling motor complete and testing complete all as specified and as directed.
102Taking down existing gear box assembly of Hangar Door motors and removing to workshop for servicing and refixing in the same location complete all as specified and directed.
103Taking down exisitng 4 x 2.5 sqmm flexible wire from control panel to motor and supply and fixing flexible cable 4 x 2.5 sqmm at any height complete all as specified and directed.
104S&F in repair of existing size PVC cable runner for smooth running of cable at any height complete all as specified and as directed.
105S&F in repair of Contactor 240 Volt complete all as specified and as directed.
106S&F in repair of Relay 6 to 10 Amps complete all as specified and as directed.
107S&F in repair existing type hooter assembly complete all as specified and as directed.
108S&F in repair existing type flash assembly complete all as specified and directed.
109S&F in repair existing type emergency switch complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail