Military Engineer Services-MES has published Tender For Repair/Maintenance/Improvement Of Street Lights, Post Top Lanterns, Apfc Panels And Certain Misc Items At Itarana, Alwar. Submission Date for this Tender is 10-12-2022. Power Factor Panel Tenders in alwar Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

34997588
Corrigendum : Tender For Repair/Maintenance/Improvement Of Street Lights, Post Top Lanterns, Apfc Panels And Certain Misc Items At Itarana, Alwar
Open Tender
Indian
Rajasthan
alwar
10-12-2022

Tender Details

Repair / Maintenance / Improvement Of Street Lights, Post Top Lanterns, Apfc Panels And Certain Misc Items At Itarana, Alwar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 03-Dec-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 10-12-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 58800.0 /-
Tender Value
Refer document

BOQ Items

Name of Work :REPAIR/MAINTENANCE/IMPROVEMENT OF STREET LIGHTS, POST TOP LANTERNS, APFC PANELS AND CERTAIN MISC ITEMS AT ITARANA, ALWAR
Sl. No. Item Description
1Disconnecting and taking down the street light fitting from the pole and repair of street light fitting of any type, capacity & make by replacement of unserviceable spare parts & making the fitting functional and refixing after repairs all as specified and directed.
2Disconnecting and taking down High Mast light from the steel tower and repair of High Mast fitting of any type, capacity & make by replacement of spare parts & making the fitting functional and refixing after repairs all as specified and directed. Note for item No. 1.00 & 2.00 : Spare parts / accessories required to be replace shall be measured and paid seperately as "supply only" under the relevent items.
3Supply only surge protection device (SPD) for LED street light fitting 45/60 watt. Make : Bajaj/Philips/Shakti/CG.
4Supply only BIS registered potted driver with "R" number for LED street light fitting 45/60 watt. Make : Bajaj/ Philips /Shakti /CG.
5Supply only surge protection device (SPD) for LED street light fitting 72/90 watt. Make : Bajaj/Philips/Shakti/CG.
6Supply only BIS registered potted driver with "R" number for LED street light fitting 72/90 watt. Make : Bajaj/ Philips /Shakti /CG.
7Supply only surge protection device (SPD) for LED street light fitting 100/120 watt. Make : Bajaj/Philips/Shakti/CG.
8Supply only BIS registered potted driver with "R" number for LED street light fitting 100/120 watt. Make : Bajaj/Philips/Shakti/CG.
9S&F in repair for 2.5 sqmm, PVC insulated and FRLS PVC Round Sheathed,twin core aluminium Conductor (flexible) industrial cable, 1100 Volts, conforming to IS: 694 from street light feeder/junction box to street light fittings. Make : Havells / Finolex / Polycab
10S&F in repair for 4 sqmm PVC insulated & sheathed cable twin core copper conductor cable from street light feeder / junction box to street light fittings. Make : Havells / Finolex / Polycab
11S&F in repair for 6 sqmm PVC insulated & sheathedsingle core copper conductor cable repair for street light feeder panel /junction box/rewiring fitting fixtures etc. Make : Havells / Finolex / Polycab
12M&L for rigid steel conduit, welded of 20mm dia for protection of wire fixing on pole as required with 2 Nos clamps complete all as specified and directed.
13S&F street light bracket made to shape at required angle made out of 40/50mm dia (light grade) GI tubing of length not less than 1.5m long suitable for fixing /holding street light fittings including mild steel flate iron 50mm x 6mm clamp 02 Nos with bolts, nuts and washer complete all as specified & directed.
14S&F in repairs decorative gate light made up of high grade unbreakable (MUSHROOM PRISMATIC) polycarbonate material including 10W LED Lamp B22 base including taking down of old unsv light.Make : Havells/Crompton/Bajaj.
15S&F in repair pole mounted juction box made out of one piece moulded SMC IP65 protection having aluminium bus bars 100 Amp three phase and neutral with one No MCB SP 6 Amp for street light, cable entry from bottom, maintenance freesize 300x200x100 mmfixing on pole with MS flat 25x3mm clamp including nut boltsfront openable all as specified and directed.
16S&F in repair for pole mounted juction box made out of one piece moulded SMC IP65 protection having aluminium bus bars 100 Amp single phase and neutral with one No MCB SPN 6 Amp for street light, cable entry from bottom, maintenance freesize 300mm x 200mm x 100mmfixing on pole with MS flat 25mm x 3mm clamp including nut boltsfront openable all as specified and directed.
17Repairing of solar security light including cleaning of solar panels, re fixing of battery terminal, checking connection of light fitting complete all as specified.
18S&F in repair of automatic street light switch using infrared Sensor based three phase nature switch for automatic switching of street lights, nature switch operation should be based on natural light lux level. Required illuminance level for switching ON is < 30 Lux and for switching OFF > 10 Lux. The sensor should also have part night operation facility of min 4 hrs to max 12 hrs 03 Nos Contactors each of 25 Amp and incoming-outgoing MCBs single pole (03 Nos each) rating 25 Amp and Auto-Manual (sensor by pass) selection option should be enclosed in a pole/wall mountable enclosure made of rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP-65. Model : Swadeep-02 EC of Swadeep /Havells/ Shakti/ Bajaj.
19Supply, installation, commissioningand testing of Lithium based energy integrated solar street light 20 Watt in single FRP body encases solar panel 44/46Wp monocrystalline, Lithium battery 11.1/12.8V, 42AH with inbuilt BMS, High brightness W-LED (160-180 lm/watt) lamp, CRI>0, Colour temperature 6500K, micro controller based charge controller cum driver, automatic dimming function with PIR motion senor, Dusk to down operation, working temperature: (-) 10C to (+) 55C, weight 10-12 kg with adjustable MS clamp suitable for pole/ wall mounting, protaction, short circuit, overload, reverse polarity and battery protections complete all as specified. Note :- (i) Firm should produce vital parameters test report from NABL accredited lab and should be of made in India with CE & ROHS certified. (ii) Firm should give warranty for the complete fitting including all electric / electronics connected parts for minimum 5 years. (iii) The complete documents regarding warranty shall be handed over to GE at the time of execution of the items in turn.Contractor may obtain warranty/extended warranty from the manufacturer for the above period. Make : Philips /Havells /Axxon.
20Repairs to street light panels by replacement of unserviceable electric items such as timer, contactor, MCB, MCCB, busbar etc wiring of suitable size copper conductor cable single core etc and setting of timer including dismantling ofunserviceable parts. Note : Spare parts measured and paid seperately under the relevent item as "Supply only".
21Supply only MCB SP 6 to 32Amps , 230 Volts, AC complete. Make : Havells/HPL/C&S.
22Supply only selecter switch four step. Make : Havells/HPL/C&S.
23Supply only electric contactor 3 pole suitable for 40 Amps 240 Volts AC complete.Make : L&T, Siemens/C&S/Havells.
24Supply only electronic digitel crono timer 240 volts, 50 Hz complete.Make : L&T, Siemens/C&S/Havells.
25Repairs to APFC panels by replacement of unserviceable electric items such as capacitor, contactor, MCB, MCCB, busbar, CTs,relay, wiring of suitable size copper conductor cable single core etc and setting of relay to achive power factor 1.00 including dismantling ofunserviceable parts.Note : Spare parts measured and paid seperately under the relevent item as "Supply only"
26Supply only contactor 3 pole, 32 Amps, 415 Volts all as specified and directed.Make : L&T, ABB, Seimens.
27Supply only contactor 3 pole, 40 Amps, 415 Volts all as specified and directed. Make : L&T, ABB, Seimens.
28Supply only contactor 3 pole, 63 Amps, 415 Volts all as specified and directed. Make : L&T, ABB, Seimens.
29Supply only cylindrical type (gas filled) capacitor440 Volt, 50Hzall as specified and directed. Make : L&T EPCOS, Seimens, Havells.
30Supply only CT ofcoil ratio 300/5 coil type for APFC control panal all as specified and directed. Make : L&T EPCOS, Seimens, Havells.
31Supply only Indicator lamp R-Y-B (set of three) all as specified and directed. Make : L&T EPCOS, Seimens, AE.
32M&L for painting of APFC/LT/SL panel board of any sizes with one coats of synthetic enamel paint smoke grey including preperation of old painted surfaces by scrapping of old surface and making good surface all as specified and directed.
33M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc. as shown in electrical plate No. 3 of SSR Part-I and connection to main switch board/test point/panel/equipment and testing on including excavation and earth work in any type of soil, returning filling in, and removal of surplus soil to a distance not exc. 50m, charcoal and salt in alternate layer 15cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20mm bore for watering and 15mm bore 3m long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25mm x 3mm bolts, nuts and washers, PCC chamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shallb e provided o CI frame etc.complete all as specified & as directed. Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 15mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost.
34Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 25 sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified including dismantling & taking out oldunserviceable cable. Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
35All as per serial item No 34.00 here-in-before but of cross sectional area 16 sqmm 2 core.
36All as per serial item No 34.00 here-in-before but of cross sectional area 10 sqmm 2 core.
37All as per serial item No 34.00 here-in-before but of cross sectional area 6 sqmm 2 core.
38Excavation in trenches n. exc 1.5Mtr width n.exc 1.5 Mtr in depth for laying of cables & foundation of poles, stay assembly and getting cut in any type of soil.
39M&L for sand cushioning to PVC under ground cable with screened and washed sand and punning to provide a required covercomplete all as specified and directed. Note :- Thickness after punning shall be considered for payment.
40M&L for brick work with FLY ASH BRICKS (As Per IS-13757(1993) burnt clay fly ash building bricks), (OLD SIZE BRICKS) (duly marked HT cable) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection and complete all as specified & directed.
41Returning, filling in including spreading levelling, watering and well ramming in layers not exc. 25cm in any type soil.
42Removing of surplus excavated soil to a distance not exc. 50m and depositing where directed at a levelnot exc 1.5 Mtr abovethe starting point.
43Boring of holes under road, pavement, hard standing by trench less technology using ultra sound technique and necessary machine including HDPE pipe of 80 mm dia suitable for 0.4 mpa working pressure.
44M&L for galvanized iron tubing, 40mm bore light grade, ISImarked, including all fittings and laid in trenches/under road/drains, or fixed to poles/walls with required size of flat iron (25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable complete all as specified and directed.
45S&F LED street light fitting 35 watt 230V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-65/66 protection complete. Make : Havells/HPL/Bajaj/Shakti.
46All as per item ser No 45.00 here-in-before but of cap 100 Watt.
47All as per item ser No 45.00 here-in-before but of cap 120 Watt.
48S&F LED flood light 100 Watt 230 volt AC outdoor type with thermal management in multiple optics and equipped with IP-66 protection with impact and corrosion resistant complete with driver and lamp. Make : Havells/Shakti/Bajaj/HPL.
49All as per item ser No 48.00 here-in-before but of cap 120 Watt.
50S&F post top lantern LED type 20 watt 230V AC outdoor type with decorative post top for 360 degree indirect light IP-65 protection with impact and corrosion resistant complete with driver and lamp complete. Make : Havells/Shakti/Bajaj/HPL.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail