Tender For Supply, Installation, Testing And Commissioning Of 4 Kwp Hybrid Rooftop Solar Pv Power Plant At Pachagarh Gram Panchayat Office Under Mtb-I Dev. Block., Coochbehar-West Bengal

Zilla Parishad-ZP has published Tender For Supply, Installation, Testing And Commissioning Of 4 Kwp Hybrid Rooftop Solar Pv Power Plant At Pachagarh Gram Panchayat Office Under Mtb-I Dev. Block.. Submission Date for this Tender is 02-12-2022. Solar Power Plants Tenders in Coochbehar West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

34986795
Tender For Supply, Installation, Testing And Commissioning Of 4 Kwp Hybrid Rooftop Solar Pv Power Plant At Pachagarh Gram Panchayat Office Under Mtb-I Dev. Block.
Open Tender
Indian
West Bengal
Coochbehar
02-12-2022

Tender Details

Supply, Installation, Testing And Commissioning Of 4 Kwp Hybrid Rooftop Solar Pv Power Plant At Pachagarh Gram Panchayat Office Under Mtb-I Dev. Block.

Key Value

Document Fees
Refer document
EMD
INR 12927.0 /-
Tender Value
INR 5.71 Lakhs /-

BOQ Items

Name of Work:Supply, Installation, Testing and Commissioning of4 kWp Hybrid Rooftop Solar PVPower Plantat Pachagarh Gram Panchayat Office under Mtb-I Dev. Block.
Sl. No. Item Description
1Supply of Solar Photovoltaic Panels.Poly Crystalline. 335Wp (Each) (Make:Panasonic/ TATA/ Renewsys) The PV modules used must qualify to the latest edition of IEC PV module qualification test or equivalent BIS standards Crystalline Silicon Solar Cell Modules IEC 61215/IS14286 .The rated output power of any supplied module shall have tolerance of +/- 3%.The peak-power point voltage and the peak-power point current of any supplied module and/or any module string (series connected modules)shall not vary by more than 2 (two) per cent from the respective arithmetic means for all modules and/or for all module strings, as the case may be.The module shall be provided with a junction box with either provision of external screw terminal connection or sealed type and with arrangement for provision of by-pass diode. The box shall have hinged, weather proof lid with captive screws and cable gland entry points or may be of sealed type and IP-65 rated.
2Lightning Protection: The SPV power plants shall be provided with lightning &overvoltage protection. The main aim in this protection shall be to reduce the over voltage to a tolerable value before it reaches the PV or other sub system components. The source of over voltage can be lightning, atmosphere disturbances etc. The entire space occupying the SPV array shall be suitably protected against Lightning by deploying required number of Lightning Arrestors. Lightning protection should be provided as per IEC standard. The protection against induced high-voltages shall be provided by the use of metal oxide varistors (MOVs) and suitable earthing such that induced transients find an alternate route to earth
3SupplyofPV Array Junction Box (AJB): a) The junction boxes are to be provided in the PV array for termination of connecting cables. The Boxes (JBs) shall be made of GRP/FRP/Powder Coated Aluminium /cast aluminium/M.S alloy with full dust, water & vermin proof arrangement. All wires/cables must be terminated through cable lugs. The JBs shall be such that input & output termination can be madethrough suitable cable glands.b) Each Junction Box shall have High quality Suitable capacity Metal Oxide Varistors (MOVs) / SPDs, suitable Reverse Blocking Diodes. The Junction Boxes shall have suitable arrangement monitoring and disconnection for each of the groups. Voltage: Max. 1000V DCMake: Power One
4Supplyof ACDB & DCDB: Designed for 5 kWp Hybrid solar power plant with all protections as per MNRE guidelines.DC DPBs shall have sheet from enclosure of dust & vermin proof conform to IP 65 protection. The bus bars are made of copper of desired size. Suitable capacity fuse & MCBs/MCCB shall be provided for controlling the DC power output to the PCU along with necessary surge arrestors and suitable battery MCB"s are used between Battery and solar PCU in DCDB . AC Distribution Panel Board (DPB) shall control the AC power from PCU/ inverter, and should have necessary surge arrestors. Interconnection from ACDB to mains at LT Bus bar while in grid tied mode.All switches and the circuit breakers, connectors should conform to IEC 60947, part I, II and III/ IS60947 part I, II and III. All the Panel’s shall be metal clad, totally enclosed, rigid, floor mounted, air - insulated, cubical type suitable for operation on three phase / single phase, 415 or 230 volts, 50 Hz.All indoor panels will have protection of IP54 or better. All outdoor panels will have protection of IP65 or better.
5SupplyofGrid tie solar PCU Rating :4KW, 1Ph Inverter – 1 Nos with nominal DC voltage 48 V DC., Make: Siemens /SMA Germany / Power One.Control : Microprocessor /DSP. HybridInverter .Nominal AC output voltage: 230V,1Phase,. Output frequency : 50 Hz . Max. DC input Power 6kW. MPPT Voltage Range 60 - 115 VDC. . Output Voltage Range - 180V - 260V AC. Grid Frequency Synchronization range : +/- 5 %. Ambient temperature considered : -10o C to 55 ?. Humidity : 90 % Non-condensing. Protection of Enclosure :: IP-21(Minimum) for Indoor.Grid Frequency Tolerance range : +/- 5 %. Grid Voltage tole rance : 180 V to 260 V. No-load losses : Less than 1% of rated power. Inverter efficiency 92%.THD : < 3%. Efficiency Measurement IEC 61683/ Equivalent BIS Std.Environmental testing IEC 60068-2 (1,2,14,30) / Equivalent BIS Std.Interfacing with utility grid IEC 61727. Islanding Prevention Measurement IEC 62116. EMI/EMC :IEC 61000-6-3>16 Amps IEC 61000-6-4<16 Amps. Safety:IEC - 62109-1 (2010/4) C - 62109-2 (2011/6). All above IEC’s should be from NABL/ IEC Accredited Testing Laboratories or MNRE Approved Test Centers/ International laboratories.
6Battery Bank Capacity should be 12 V , 150 Ah. b.VRLA tubular GEL type batteries conforming to IEC-61427 & IS-1651 /IS 13369 Standards, low maintenance, stationery at C/10 rate). It will be staged in racks duly painted with acid resistant paint to cover less space.
7Supply of System Earthings : Each array structure of the PV yard should be grounded/ earthed properly as per IS:3043-1987. In addition the lighting arrester/masts should also be earthed inside the array field, PCU, ACDB and DCDB should also be earthed properly. Earth resistance shall not be more than 5 ohms. It shall be ensured that all the earthing points are bonded together to make them at the same potential.
8Lightning Protection: The SPV power plants shall be provided with lightning &overvoltage protection. The main aim in this protection shall be to reduce the over voltage to a tolerable value before it reaches the PV or other sub system components. The source of over voltage can be lightning, atmosphere disturbances etc. The entire space occupying the SPV array shall be suitably protected against Lightning by deploying required number of Lightning Arrestors. Lightning protection should be provided as per IEC standard. The protection against induced high-voltages shall be provided by the use of metal oxide varistors (MOVs) and suitable earthing such that induced transients find an alternate route to earth
9Supply of CablesDC & AC: Sizes of cables between array interconnections, array to junction boxes, junction boxes to Inverter, Battery to Inverter etc. shall be so selected to keep the voltage drop of the entire solar system to the minimum. The cables (as per IS) should be insulated with a special grade PVC compound formulated for outdoor use. The size of each type of DC cable selected shall be based on minimum voltage drop however; the maximum drop shall be limited to 1%. The size of each type of AC cable selected shall be based on minimum voltage drop however; the maximum drop shall be limited to 2 %. i. Shall meet IEC 60227/IS 694, IEC 60502/IS1554 standards.
10Installation, Testing & Commissioning