Asansol Durgapur Development Authority -ADDA has published Tender For Construction Of Sanskriti Mancha At Tarasankar Uddyan, Aranyak Purbanchal, Bidhannagar, Durgapur-12.. Submission Date for this Tender is 26-11-2022. Civil Work Tenders in durgapur West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

34775494
Tender For Construction Of Sanskriti Mancha At Tarasankar Uddyan, Aranyak Purbanchal, Bidhannagar, Durgapur-12.
Open Tender
Indian
West Bengal
durgapur
26-11-2022

Tender Details

Construction Of Sanskriti Mancha At Tarasankar Uddyan, Aranyak Purbanchal, Bidhannagar, Durgapur-12. Civil Works

Key Value

Document Fees
Refer document
EMD
INR 40331.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Construction of Sanskriti Mancha at Tarasankar Uddyan, Aranyak purbanchal, Bidhannagar, Durgapur-12.
Sl. No. Item Description
1Clearing compound premises of shurbs, plants, jungles etc. by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary).
2Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.
3Earth work in excavation of foundation trenches or drains, in all shorts of soil (including mixed soil but excludinglaterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 meter as directed.The item includes necessary trimming the sides of trenches, levelling,dressing and ramming the bottom, bailingout water as required complete.Depth of excavation not exceeding 1.50 M .
4Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layercomplete. (Payment to be made on the basis of measurement of finished quantity of work). Withearth obtained from excavation foundation.
5Filling in foundation or plinth by fine sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water,ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
6Supplying and laying polythene sheet (150gm/sqm) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
7Ordinary cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering & reinforcement, if any, in ground floor as per relevant IS codes.Pakur variety.
8Hire and labor charges for shuttering with centering and necessary staging upto 4musing approved stout props and thick hard wood planks of approved thickness with required bracing for concreteslabs, beams and columns , lintelscurved or straight including fitting, fixing and striking out after completionof works (upto roof of ground floor)25mm to 30mm thick wooden shuttering without staging in foundation. For the work in foundation (PCC side and column raft sides)
9Hire and labor charges for shuttering with centering and necessary staging upto 4musing approved stout props and thick hard wood planks of approved thickness with required bracing for concreteslabs, beams and columns , lintelscurved or straight including fitting, fixing and striking out after completionof works (upto roof of ground floor) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work.Ground floor
10Ordinary cement concrete ( mix 1:1.5:3) with graded stone chips ( 20 mm nominal size) excluding shuttering & reinforcement if any.Pakur Variety Ground floor
11Reinforcement for reinforced concrete work in all sorts of structuresincluding distribution bars, stirrups, binders etc. initial straightening and removal of loose rust (if necessary) cuttings to requisite length, hooking and bending to correct shape,placing in proper position and binding with 16 gauge black annealed wire at every intersection,complete as per drawing and direction.Tor steel/Mild steel,For the work in foundation, basement and up to roof of ground floor/4.00 m JSW / JSPL /SHYAM /SRMB /BMASL /ELECTROSTEEL /SSL.( Tor Steel Rods/HYSD/Fe 415/Fe 500/Fe 500D. ).
12Removal of rubbish , earth etc from the working site and disposal of the same beyond the compound in conformitywith the municipal corporation rules for such disposal loading into truck and cleaning the site in all respect as per direction of E.I.C
13Brick work with 1st class bricks in cement mortar (1:4)(b) In superstructure, ground floor
14125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor.
15Extra for using approved H.B netting in every third layerin any floor
16Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer"s specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contrr]e). With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment.Light Colour.
1718 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m].
18Plaster (to wall,floor,ceiling, etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding /staging where necessary (excluding cost of cheaping over concrete surface where necessary) .10 mm thick (1:4) plaster.
19Plaster (to wall,floor,ceiling, etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding /staging where necessary (excluding cost of cheaping over concrete surface where necessary)15 mm thick(1:4) plaster .
20Plaster (to wall,floor,ceiling, etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding /staging where necessary (excluding cost of cheaping over concrete surface where necessary)20 mm thick (1:4) plaster.
21Labour for Chipping of concrete surface before taking up Plastering work.
22Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc.
23Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer"s specification and as per direction of the EIC. One Coat.
24Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer"s specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.(Two Coat),Normal Acrylic Emulsion
25M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161- 1998 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc. For trusses spanning up to 12.00 m
26Supplying , fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make as per IS:15965:2012 and IS:14246:2013 (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work). In Roof:- With 0.5 mm thick sheet
27M.S gate of jail type as per approved design made of strong M.S frame work, intermediate stiffners and round / square bars or angles.M.S.sheet ( not less than 14 gauge) gussets, cleats etc including necessary riverting, bolting, welding , locking and hanging arrangements, fitting & fixing complete as per direction of the Engineer- in- charge.
28M.S. or W.I.Ornamental grill of approved design joints continuously welded with M.S. or W.I.flats and bars of windows, railing etc. fitted and fixed withnecessary screws and lugs in ground floor.Grill weighing above 16 Kg./sq.mtr and above.
29Supplying, fitting and fixing UPVC pipes A-Type and fittings confirming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor, etc. cutting trenches in any soil through masonary concrete structures etc. if necessary and mending good damagaes including jointing with joining materials(spun,yarn,valamoid/M-seal etc.) complete i) 110 mm diaUPVC Pipes:
30UPVC Fittings . Bend 87.5 degree110mm dia.
31Shoe110mm dia.
32Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. With Pakur variety. JSW / JSPL /SHYAM /SRMB /BMASL /ELECTROSTEEL /SSL.
33Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer"s specification and as per direction of the EIC. (In Ground Floor).One Coat.Water based interior grade Acrylic Primer.
34Dry Distemparing to interior walls or ceiling including cleaning, washing, smoothening surface. Two coat.
35Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surface by sand papering etc. AndPainting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc .
36Painting with best quality synthetic enamel paint of approved make using of approved putty etc. on the surface, if necessary :On steel or other metal surface :With super gloss (hi-gloss) -Two coats (with any shade except white)
37Supplying , fitting and fixing fan hook for ceiling with 1.0m long 16 mm dia. rod complete including mending damages. Payment for damage and repair to be made separately.
38Supplying, fitting and fixing Peet"s valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.). 25 mm dia
39Chromium plated Bib Cock long body with wall flange with aerator (Equivalent to Code No. 512 & Model - Tropical / Sumthing Special of ESSCO or similar brand)
40Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar
41Supplying & Hoisting plastic water storage tank of approved quality with closed top with lid ( Black) Multilayer & with punching holes placing in position.1000 liters
42Renewing high pressure ball cock of approved quality with polythene ball and aluminium lever complete for pipe of dia20mm
43Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets. 630 mm X 550 mm X 180 mm .
44Supplying fitting and fixing cast iron “P” or “S” trap conforming to IS3989/1970and 1729 / 1964including lead cocked joints and painting two coats to the exposed surface with approved paint complete. ( Payment of painting will however be paid separately ). Without A.S horn i) “P” Trap 100 mm dia
45Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. For Concealed Work.CPVC Pipes Class-1,SDR-11. 25 mm.
46ii) 15 mm dia.
47Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge.Weight of Strainless Steel railing per metre 6.5 Kg (approx)
48Construction of Plaque with Brickwork Structure providing letters embossed over Granite Board (900 mm x 1200 mm) & fixing it, Plastering , painting etc complete at site as per drawing , specification and direction of the Executive Engineer
49GST as applicable @ 18 % on total work done value (Sl. No. 1 to 47)
50Labour Welfare Cess @ 1 % on total work done value including GST (Sl. No. 1 to 48)
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail