Tender For Development Of Area For Amc Vending Zone At Office Lane North Side Of Amc Head Office By Providing Paver Block, Electrification, Drinking Water Etc. Under Central Zone, Amc., agartala-Tripura

Agartala Municipality Corporation has published Tender For Development Of Area For Amc Vending Zone At Office Lane North Side Of Amc Head Office By Providing Paver Block, Electrification, Drinking Water Etc. Under Central Zone, Amc.. Submission Date for this Tender is 11-11-2022. Electrification Work Tenders in agartala Tripura. Bidders can get complete Tender details and download the document.




Tender Notice

34561851
Tender For Development Of Area For Amc Vending Zone At Office Lane North Side Of Amc Head Office By Providing Paver Block, Electrification, Drinking Water Etc. Under Central Zone, Amc.
Open Tender
Indian
Tripura
agartala
11-11-2022

Tender Details

Development Of Area For Amc Vending Zone At Office Lane North Side Of Amc Head Office By Providing Paver Block, Electrification, Drinking Water Etc. Under Central Zone, Amc.

Key Value

Document Fees
INR 1000 /-
EMD
INR 11020.0 /-
Tender Value
INR 5.51 Lakhs /-

BOQ Items

Name of Work: Development of area for AMC vending zone at Office Lane (North side of AMC Head Office) by providing paver block, electrification, drinking water etc. under Central Zone, AMC.
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. -All kinds of soil .
2Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete.
3Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering -All work upto plinth level: -1:3:6 ( 1 Cement: 3 fine sand : 6 graded well burnt brick aggregate 20 mm nominal size)
4Providing and laying cement concrete of specified grade excluding the cost of centering & shuttering all works upto plinth levelt with 1:2:4 (1 cement : 2 fine sand : 4 graded stone aggregate 20 mm nominal size)
5Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement- All work up to plinth level 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)
6Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto floor five level.Thermo-Mechanically Treated bars of grade Fe-500D or more
7First class brick work in foundation and plinth including cost of all materials as required complete:-In cement mortar 1:4 ( 1 cement : 4 fine sand ).`
812 mm cement plaster of mix : In cement mortar 1 : 4 ( 1 cement : 4 fine sand )
9Centering shuttering including struttings, propping etc. and removal of form work for: Foundations, footings, bases for columns etc. for mass concrete with timber plank
10Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
11Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge i)15 mm dia. nominal bore
12Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge ii) 25 mm dia. nominal bore
13Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : 15 mm nominal bore
14Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal bore
15Drilling and boring pilot hole in any soil strata by manual means, collection of soil samples of different strata met with during drilling at various suitable levels, preservation of samples in polythene bags / sample boxes and disposal of excess soil or mud, including the cost for water etc. as required to maintain the pilot hole properly as per specification and direction of the Engineer - in -charge
16Reaming of pilot hole to an enlarged bore hole in any soil strata by manual means, disposal of excess soil or mud, including the cost for water etc. as required to maintain the bore hole properly as per specification and direction of the Engineer - in - charge.
17Providing and fixing of UPVC end cap suitable for UPVC "CM" casing or "CS" casing or "RS" pipes as per specification and direction of the Engineer - in - charge.
18Providing & lowering of UPVC pipe as per IS:12818 after washing of the bore hole by manual meansas per specification and direction of the Engineer - in - charge. A) "CM" casing pipe i. 150 mm dia
19Providing & lowering of UPVC pipe as per IS:12818 after washing of the bore hole by manual meansas per specification and direction of the Engineer - in - charge. A) "CM" casing pipe iii. 100 mm dia
20Providing & lowering of UPVC pipe as per IS:12818 after washing of the bore hole by manual meansas per specification and direction of the Engineer - in - charge. B) "RS" Pipe i) 100 mm dia
21Providing and fixing of UPVC reducer suitable for UPVC "CM" casing or "CS" casing or "RS" pipes as per specification and direction of the Engineer - in - charge.
22Washing and development of tube well by using hand pump or by any suitable method and testing of the wellas per specificationand direction of the Engineer - in - charge
23Providing and Shrouding of the deep tube well assembly with washed pea gravels ( 2.0 - 4.75 mm effective size ) as per specification ( IS : 4097) using deep drilling rigand direction of the Engineer - in – charge.
24Supplying and installation of water lubricated submersible pump having ISI marked of capacity 2000 GPH at total head up to 60 mtr.Cuple with submersible motor 2HP suitable for 240 voltas(+10% variation single phase 50 HP .AC supply DOL starting method to run at 2880 RPM along with 35 mtr 2.5 sqm. PVC insulated 3 (Three) core Flate copper cables including fitting fixing and lowering if with 40 mm dia G.I Pipe up to 100 FT.(30.00 mtr) etc. complete as per direction of the Engineer-In-Charge.(40 mm dia G.I pipe and fitting will be paid separately)
25Supplying and fitting fixing of MS box of having size 60 cm x 60 cm x 45 cm with slope roof and font shutter with locking arrangement fitted with 4 Nos 40 mm x 40 mmx 6 mm MS angle of 1.60 m long in/c providing & fitting wooden board inside the box having size 55 cm x 55 cm x 1"" thick for fitting all the electrical features like starter,main switch and in/c cost of necessary painting & embedding the box with CC block size 30 cm x 30 cm x 60 cm with 1:2:4 (1 Cement : 2 river Sand : 4 Jhama brick aggregate 20 mm gauge) as per direction of the Engg-in-charge.(Starter,Main switch will be paid separately).
26Supplying and fitting fixing of single phase motor starter panel unit 3.0 HP capacity comprising with 2 pole conductor, over load relay, capacitor,volts meter of BCH/L&T make with necessary copper wire etc. complete as per direction of the Engg-in-charge.
27Supplying & fitting, fixing of 32 Amps single phase Main switch of BCH/L&T/Havel"s make with necessary copper wire wiring etc.complete as per direction of the Engg-in-charge.
28Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of sand, filling the joints with fine sand etc. all complete as per specification and approval/ direction of the Engineer-in-charge
29Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]:Two or more coats on new work over an under coat of suitable shade with ordinary paint (primer) of approved brand and manufacture
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail