Special Repair Works In Government Elementary School Rana Kala Jandiala Guru District Amritsar, Amritsar-Punjab

Public Works Department-PWD has published Special Repair Works In Government Elementary School Rana Kala Jandiala Guru District Amritsar. Submission Date for this Tender is 10-10-2022. Building Work Tenders in Amritsar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

34231473
Special Repair Works In Government Elementary School Rana Kala Jandiala Guru District Amritsar
Open Tender
Indian
Punjab
Amritsar
10-10-2022

Tender Details

Special Repair Works In Government Elementary School Rana Kala Jandiala Guru District Amritsar

Key Value

Document Fees
INR 5000 /-
EMD
INR 14945.0 /-
Tender Value
INR 7.47 Lakhs /-

BOQ Items

Name of Work: Special Repair of Government Elementary School Rana Kala in Assemby Jandiala Guru District Amritsar
Sl. No. Item Description
1Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.
2Cement concrete 1:5:10 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type
3First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth
4First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level.
5Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.
6Cement concrete 1:5:10 With stone aggregate 40mm gauge mixing by mechanical means using concrete mixer volumetric type
7Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure.
8Centering and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
9First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth
10First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level
11115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1:4 cement mortar in superstructure
12Dressed or moulded one brick cornice laid in cement sand mortar 1:4 including 12.5mm thick cement plaster 1:4 or pointing as required
1312.5mm Thick cement Plaster 1:5
1420mm thick cement plaster
1512.5mm Inner Plaster 1:4
1620mm Thick cement Plaster 1:4
17Plastering on underside of ceiling 6mm thick cement plaster 1:4
18Providing and fixing 110 mm dia . U.P.V.C Rain water pipe of 4 kgf./sqm as per IS:4985 including jointing during masonary complete as per specifications and to the entire satisfaction of Engineer-in- charge.
19Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. (a. UPVC 110 mm bend)
20Providing and fixing 110 mm dia. U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. (a. UPVC 110 mm Coupling /Sockets)
21Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting. (a. M.S. Holder bats clamps for 100mm i/d H.C.I. pipes)
22Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00 thick cement concrete 1:8:16
23Providing and fixing in position gratings 150mm x 150mm for gully trap. (a. H.C.I. grating including painting with black bitumastic superior paint of approved manufacture three coats.)
24Bottom khurra on ground 1.2m 0.6m consisting of bricks on edge laid in cement mortar 1:3 over 7.5 cm cement concret 1:8:16 including 12.5mm thick cement plaster 1:3
25Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
26Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
27Earth Filling good Quality earth obtained from outside the Plinth
28Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
29Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone agregate 40 mm gauge and100mm sand filling using mechanical mixer for mixing of material
30Marble stone flooring with 18-20 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Udaipur Green Marble Tiles of thickness 18mm to 20mm Slabs sizes above 0.50 sqm
31Providing and laying Anti skid Ceramic floor tiles of size 300x300 mm x 10 mm thick of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on flooring skirting and dado in 12.5mm thick cement plaster 1:3 in base and jointed with @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., completewhite cement slurry in joints including corners angles and beading.
32Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/ Highlighter/ emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 200 x 300 mm, 100x200mm, 200x200mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
33Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete
34Doors and windows frame of size 113mm x 60mm with 35 mm wide single rebate weighing 3.38 kg per meter.
35Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter.
36Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area
37Extra for providing & fixing Steel beading of approved shape steel tube beading size 12mm X 12mm, 18 gauge of approved shape and section with screw for fixing of glass panes instead of glazing clips and metal slash putty in steel doors , windows & Ventilators complete in all respect
38Wrought iron & Mild steel ladders, framed grills, gratings etc. with ends of bars riveted or molded forged framed window guards, barred iron doors stair case iron railing etc. including cost of bolts and nuts, screws, welding rod complete fixing in position
39Providing Polyester Powder coating 60 to 70 micron any coloured specified to M.S Grill section of various sizes including carriage of material from market to workshop & workshop to site of work.
40Factory manufactured flush Solid door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2202-1 Part-I) 1999 Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:- 35mm thick
41Cost of aluminum fittings complete for doors, windows such as tower bolts, handles,Stoppers and screw etc. for these fittings (Excluding sliding bolt) For shutter area above 0.50 sqm
42Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : 300mm x 16mm
43Cold twisted deformed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
44preparation of plastered or concrete surace for painting (including sand papering the surface ) using ready mixed cement based wall putty by applying two coats to get required finish
45Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
46Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two or more coats)
47Finishing walls with exterior decorative cement based paint such as snowcem,robbiacem etc. two or more coats to give an even shade
48Applying priming coat with metal primer on new steel or iron work including preparation of surface.
49Painting two or more coats excluding priming coat with ready mixed paint for metallic surfaces in all shades on steel or iron work
50Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete.
51Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
52Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
53Providing & Fixing of 10 gauge welded mesh of 25mm x 25mm size fixed on steel glazing with MS flat 20mm x 6mm beeding complete in all respect including painting two coats with Synthetic Enamel Paint and Priming Coat
54Corrugated G.I. Sheet roofing 0.80 mm thick fixed with galvanized iron J or L hooks 10mm dia, G.I. Limpot and bitumen washers complete excluding the cost of purling rafters and trusses
55Dismantling of Conglomerate Floor without base
56Kota stone tile flooring 20mm to 30 mm thick over 12.5mm thick base of cement mortar 1:3 (1 cement, 3 Sand) laid and jointed with neat cement slurry, mixed with pigment to match the shade of stone including rubbing and polishing
57Kota stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing.
58Scrapping of Cement Plaster
5912.5mm Thick cement Plaster 1:4
6020mm thick cement plaster 1:4
61Preparation of plastered surfaces for distempering including surface, applying filling with approved quality filler consisting of plaster of paris and chalk mitti including finishing the surface to the required finish complete
62Distempering with dry distemper of approved manufacture two or more coats over one priming coat to give an even shade
63Excavation Manually in trenches with straight or open cutting in built up street /lane having wall to wall width of street/lane complete as on per chapter no 29.1A
64Providing and fixing in position H.C.I. soil waste vent or antisyphonage pipes to I.S.I. specification (IS:1729) of approved make (to the approval of Engineer-in-charge ) including cutting, jointing, wastage, but excluding cost of lead jointing. (Ch. 30.74 ii) (b)
65Providing and Fixing in position SWR UPVC soil waste vent or antisyphonage pipes as per IS-13592 of approved make (to the approval of Engineer in Charge ) inculdingcutting joining wastage, but excluding cost of lead joining (Ch. No. 30.74 iii B (b)
6675mm
67110mm
68Cement Concrete 1:3:6 with stone ballast or shingle. (Ch.No. 10.12 a ii)
69Providing and fixing in position Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.
70Providing and fixing H.C.I. Floor traps conforming to I.S.I. Specification (IS:1729)of approved make (to the approval of Engineer-in-charge) of the self cleaning design with C.P. brass hinged grating with frame with or without vent arm and including cement concrete 1:2:4 under and around the floor trap where required upto floor level complete in all respects including cutting and making good the walls and floors,etc. minimum depth of water should be 150mm with a minimum seal 50mm. (Ch.30.79) a
71Providing lead caulked joints to H.C.I. pipes and specials conforming to I.S.I. Specification (IS:1729)of approved make (to the approval of Engineer-in-charge ) including cost of lead yarn, fuel and toolsetc. (Ch. 30.77 A)
72Providing & fixing in positionvitreous Chinware white flat back or angular lipped front urinal of approved make (to the approval of the Engineer-in-charge) ofsize460 x 350 x 260 mm with C.P. brass tube connection 300 mm longcomplete in all respect. (Ch. 30.15)
73Providing and fixingin position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including brass studs without CP fittings complete in all respect.(Ch. 30.32 ii)
74Providing & fixing in position C.P brass sink cock with swimming spout (wall mounted) of approved make(to the approval of engineer in charge) complete in all respect (Ch.No. 30.48)
75Providing and fixing jet spray with 2"-6" long PVC pipe. (Ch.30.8 a) With C.P. Brass nut
76Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backingfixed in with rawl plugs 50mm, C.P. brass screws and washers complete in all respect (as required by the Engineer-in- Charge) (Ch. 30.61)
77Providing and fixingin position C.P. brass soap dishof approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. (Ch. 30.60)
78Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.b) C.P brass towel ring
79Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. b) 450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal
80Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc.as per standard design minimumdepth of water should be 150 mm with a minimum seal 50mm. (Ch. 30.99)
81Providing lowering, cutting & jointing salt Slazed stone ware pipes and specials ISI marked as per IS 651-2007 class Sp-1into Trenches for all depths complete as per (Ch. No. 29.41a) 100 mm i/d
82Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. (Ch. 30.65 a)
83Providing, Laying, Jointing, fixing and testing ISI marked G.I, PipeB-class complete as per (Ch. No. 28.35) a (C) d
84a) 15 mm dia
85b) 25mm dia outlet pipe
86c)32 mm I/d
87Providing, fixing, Jointing G.I. Union couplings as per IS 1879 in G.I. Pipe line complete in all respects (Ch. 28.40)
88c) 32mm I/d G.I. Union
89d) 25 mm I/d G.I. Union
90Providing, fixing and jointing ISI Marked Gun-Metal peet valves as per IS 778 complete as per (Ch. No. 28.43) c
9125mm I/d Gun Metal peet valves heavy pattern
92Providing & fixing in position PVC flexible tube connectionof approved make (to the approval of Engineer-in-charge ) complete in all respect. (Ch. 30.72 a)
93a) PVC tube connection of size 15 mm x 300 mm with C.P. Brass nut
94Septic Tank
95Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.
96Cement Concrete 1:6:12 With 40mm gauge with brick ballast
97First class burnt brick laid in cement sand mortar 1:6 in foundation and plinth
98Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation.
99Cold twisted deformed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete
10012mm thick cement plaster 1:4
101Cement rendering on plaster 1mm thick
102Conglomerate floor 40mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material
103Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD).500mm i/d RCC man hole cover with frame as per ISI (Heavy duty)
104Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer"s permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design.
105Submersible Pump
106Boring with casing pipe for tubewell in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested , equipment as requried such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect. Boring with 150mm id Housing Pipe Upto 150 m depth BGL.
107Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818-2010, including required hire and labour charges, fittings &accessories etc. all complete, for all depths, as per direction of Engineer – incharge. 100 mm nominal size dia.
108Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia.
109Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect. 100mm internal diameter
110Supplying & fixing of M.S Clamp of size 150mm X 12mm made out of MS Flat 1.52m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect.
111Providing and laying, jointing, fixing and testing ISI Marked uPVC Pipe Lines as per ISI 4985-2000, including specials such as tees, bends, sockets, elbow etc., cutting, testing (including cost of specials) in the ground complete in all respects. uPVC Pipe 10 Kgf/cm2 (25mm i/d)
112RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES:
113WiringinPVCinsulatedcopperconductorsingle core FR cable (ISI marked) overall 1.5sq. mm, 1100voltsgradetobelaidinheavygaugePVC conduitpipe20mm/25mmdia.(ISI Marked) recessed in wall etc., completewith powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number ofmodules(Modularaccessories)forhavingStep typeelectronicfanregulators(twomodule) 100watts,bellpush,6Amp.2/3universalsocket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches and 16/20Amp. switches with indicator etc. and covered with Frame Plateetc.,PVCconnector(ForFanBoxandCall Bell),SteelHooks,Sheetmetalfanbox(1.6mm thickshapehexagonal),CircularjunctionBoxes (Four way PVC1½"deep for wallsand CI3" deep forceiling),bondingtoearthwithPVCinsulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plugcontrolpoint) andotherpettymaterialetc. includingthecostofabovematerial,cuttingand filling up of chases:- Make: Polycab/ Anchor/ Diplast/ Norpack
114Wiring light point
115XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE):
116Supply, laying and erection of aluminium conductor XLPEinsulatedPVCsheathedUn-armouredand served cable 1100 volts grade as per IS 7098 (Part- 1)1988 to be laid (On Surface) as per PWD General Specifications:-
117Overall size6sq.mm (2Core)Un-armoured(On- Surface)
118G.I. EARTHING:
119EarthingwithG.I.wire/ropeinG.I.pipepartly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket includingerectionofthesame,4.50metre(14.76 feet) below ground level with 20Kg. charcoal & salt mixtureetc.,upto8metreinlength(including boring & refilling).
120Earthingwith8S.W.G.(4mmdia.)G.I.wirein15mm diaG.I. pipewithG.I. reducingsocket 50mmx 15mm (upto 8Metre in length)
121SUPPLY ANDERECTIONOFWIRING ACCESSORIES:
122Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frameincludingfixing&connectionsandpetty material etc:-
123Ceiling Rose (Flush Piano type)
124MINIATURE CIRCUIT BREAKERS/ RCBO"s/ RCCB"s:
125MCB Single Pole 6-32amp. (10kA, Curve-C)
126MCB Single Pole 40amp. (10kA, Curve-C)
127SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB"s:
128SupplyanderectionofsheetmetalDoubleDoor DistributionBoardsIP43-IK09metaldoor(dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fullyinsulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wireset,cableties,blankingplatesandcircuit identifications label and of required no. of ways for mounting miniaturecircuitbreakers/ RCBO"s/ RCCB"s in the distribution board (For SP&N distributionboardwithprovisionDPMCB/RCCB/ RCBO as incomer and SP MCB"s as outgoings and forTP&N horizontaldistributionboardwith provisionTPN/FPMCB/RCCB/ RCBOasincomer andSPMCB"sasoutgoings)asperPWDGeneral specificationsincludingconnectionswithsuitable size of thimbles and bonding to existing earth etc:- Make: Legrent (Ekinoxe), Scheinder (Acti-9) L&T (Exora), Hager (Novella), Havells (Qve) or Equivalent.
129SP&N Double Door Distribution Board 4 way each
130SP&N Double Door Distribution Board 4 way each
131Supply & Erection of Durable LED Batten with Polycarbonate Housing 20 Watt Make: Crompton Input AC Frequency Hz +- 3% complete along with erection of the same with, testing,in all Respect.complete in all respect as per approved /desired by the engineer in charge of work at site . The Certification and Specification of The Led fitting should be as approved by of O/o Advisior( Technical) Govt. of Punjab Letter No: AT/2021/GL/1410-1422 Dated 16-05-2021.Make : Crompton Model : LCTLN-20-CDL, Phillips item BN021CLED22 PSU CW GR, Make: Havell"s Item Code: LUMILINEBS20WLED865SPCWH.
132Supply and erection of Heavy duty Exhust Fans 300mm 900RPM with aluminium louver shutter Canon of double ball bearinglonger life including flexible wire & petty material etc. for connections and testing completein all respect as approved and desired by the Engineer in-charges at site. Make:-Crompton EXHD300-6-1 /Havells Turbo Force SP /Make: OrientHeavy Duty Exhaust Fan-Grey.
133inaugration stone