Public Works Department-PWD has published Proposed G+3 Construction Of Mother And Child Hub At Anupnagar Block Phc In The District Of Murshidabad --- Supply Installation Testing And Commissioning Of Air Conditioning Machine. Submission Date for this Tender is 31-10-2022. Air Conditioner Tenders in Murshidabad West Bengal. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Supply, Installation, Testing & Commissioning of split type AC machines havingCooling Capacity range (5.2 kw - 5.3 kw), with fixed speed rotary compressor, refrigerant gas R32/R410 BEE star rating -3 (EER range 3.5 to 3.99), Air flow range CFM (560-600), both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments (Make- Mitsubishi Electric/Daikin/O-General/ Carrier/ Voltas/ Blue Star/LG/Panasonic/Hitachi/Mitsubishi Heavy) [The indoor unit should be made ofsheet metal enclosure having high static delivery of air] |
2 | Supply, Installation, Testing & Commissioning of split type AC machines havingCooling Capacity range (6.6 kw - 7.0 kw), with fixed speed rotary compressor, refrigerant gas R32/R410 BEE star rating -3 (EER range 3.5 to 3.99), Air flow range CFM (780-850), both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments (Make- Mitsubishi Electric/Daikin/General/ Carrier/ Voltas/ Blue Star)[The indoor unit should be made ofsheet metal enclosure having high static delivery of air] |
3 | Supply, Installation, Testing & Commissioning of split type AC machines havingCooling Capacity range (10.00 kw - 11.00 kw), with fixed or variable speed rotary compressor, refrigerant gas R32/R410 BEE star rating -3 (EER range 3.0 to 4.0), minium Air flow range CFM (740-960) or better, both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments (Make- Mitsubishi Electric/Mitsubishi Heavy/ O General/ Hitachi/ /LG/Toshiba/ Panasonic) [The indoor unit should be made ofsheet metal enclosure having high static delivery of air] |
4 | Supply, Installation, Testing & Commissioning of split type AC machines havingCooling Capacity range (8.72 kw - 8.79 kw), with fixed or variable speed rotary compressor, refrigerant gas R32/R410 BEE star rating -3 (EER range 3.0 to 4.0), minium Air flow range CFM (740-960) or better, both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments (Make- Mitsubishi Electric/Mitsubishi Heavy/ O General/ Hitachi/ /LG/Toshiba/Panasonic) [The indoor unit should be made ofsheet metal enclosure having high static delivery of air] |
5 | S/F of 3 core round copper cable of 2.5 sq.mm, 5/8" &1/4" copper pipe nitrile rubber insulation cover(minium 9 mm thick), 19 mm dia PVC water drainage pipe, Insulation tape, fastner, etc as per direction of EIC |
6 | Supply and laying of 1.1 KV grade copper armoured round Cable of the following sizes from IDU Unit to ODU unitfor the above mentioned AC units (Make : Polycab/Havells/Gloster/Finolex) |
7 | 3 core 1.5 sqmm |
8 | Supply and fixing of UVC EMIITTER (minimum 10watt) for the above IDUs for prevention of fungus in the cooling coils, The minimum UV intensity in the coils shall be 350-400 UW-SEC/CM2. The unit shall be UL.Listed (UL-1995) and it should be suitable to fix the same in conceal unit (Make - Alfa / Ruks/Jhonson/Streil-aire). |
9 | Supply & installation of 25 mmPVC Drain Pipe Line (25 mm /32 mm OD,HD 1 mm thick )of the following size with 6 mm nitrile rubber insulation and withproper supports & brackets as per direction of E.I.C. (Make: Suprime/Oriplast) |
10 | Supplying,fitting & fixing in position suspended boxing for return and supply air arrangement for ducting incl false ceiling for boxing of IDU with frame work of aluminium hollow section of size 50mm X 25mm (2.0mm thickness) combined with aluminium corners of size 38mm X 25mm, suspended by aluminium hollow tube section of size 38mm X 25mm having size as suitable with aluminium composit panels (ACP) - Interior grade of thickness 3.0 mm comprising of proctective film, polyester coating, primer, aluminium coil, adhesive film, polyethylene core again with one layer adhesive film, aluminium bottom coating and finally service coating as per manufacturer"s specification finished with aluminium screw and silicon sealent incl.suitable arrangement of grill fixing complete in all respect including all incidental charges etc. as per direction of EIC. |
11 | Installation Charges for Trap door with Aluminiun channel &ACP Board (3 mm thick) (Make:Aludecor/Protap Bond)Complete with linkages, levers, fittings, supports, all accessories for IDU Maintenance as per direction of E.I.C. |
12 | Supply & Fixing of Powder Coated extruded aluminium Supply Air Grills with aluminium volume controll dampers complete as per specification. |
13 | Supply & Fixing of Powder Coated extruded aluminium Return Air Grills with louvers but without volume controll dampers complete as per specification. |
14 | Supplying, fabrication & fixing2 Nos. M.S. Angle ofsize (50 mm x 50 mmx6mm) for making platform for installation of outdoor unit AC incl. drilling 2 nos holesin each Angle including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 40 mm x40mm x 6 mmin each platform in outer edge for transmitting the load centrally through 2Nos. (40 mm x 40 mm x 6 mm) Angle inserted into the exiting wall. Area of the platform is 2Mtr. x 1Mtr. or as per Machine configuration & load with adequate service access as per direction of EIC. |
15 | Supply and fixing flexible double canvass connection for Ductable splitair-conditioners. (FR) |
16 | Terms and condition |
17 | The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. |
18 | Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent upon award of the contract from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill. |
19 | If any refurbished material is supplied and installed, penal action will be taken as per existing rules |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail