Sl. No. | Item Description |
1 | REGULAR MAINTENANCE OF HOUSEHOLD ELECTRICAL INSTALLATIONS IN TOWNSHIP |
2 | Removing of old one and fixing of 250 V main switch with necessary earthing as directed. |
3 | 16 Amp (All materials as required would be supplied by the M/s APL) |
4 | 32 Amp (All materials as required would be supplied by the M/s APL) |
5 | Removing of old one & fixing of 250 VICDB having 15 A per way with necessary earthing as required. |
6 | 3-way (All materials as required would be supplied by the M/s APL) |
7 | 4-way (All materials as required would be supplied by the M/s APL) |
8 | 6-way (All materials as required would be supplied by the M/s APL) |
9 | Replacement of defective TPN MAIN SWITCH |
10 | Replacement of defective TPN DB |
11 | Fixing of brass batten/angle holder as directed including fixing of round blocks. |
12 | Erection of ceiling fan 1200 mm sweep and wiring the down rod with connection of 23/0076 size flexible wire. |
13 | Fixing of IC cutout of 250 V inside meter box and connecting the same after removing the old one. |
14 | 15 Amp. (All materials as required would be supplied by the M/s APL) |
15 | 30 Amp. (All materials as required would be supplied by the M/s APL) |
16 | Wiring for sub-main with PVC Aluminium wire of the following sizes : |
17 | 2 x 4 mm2 (All materials as required would be supplied by the M/s APL) |
18 | 2 x 6 mm2 / 2 x 10 mm2(All materials as required would be supplied by the M/s APL) |
19 | Wiring for service line with water proof Aluminium conductor of the following size. |
20 | 2 x 4 mm2 / 2 x 6 mm2. (All materials as required would be supplied by the M/s APL) |
21 | 2 x 10 mm2. (All materials as required would be supplied by the M/s APL) |
22 | Removing of burnt switch and fixing of new switch including connection etc. on existing board. |
23 | 5 Amp. Piano type. (All materials as required would be supplied by the M/s APL) |
24 | 15 Amp. Piano type. (All materials as required would be supplied by the M/s APL) |
25 | Removing of burnt switch sockets and fixing of new one including connection on existing board. |
26 | 5 Amp. Piano type. (All materials as required would be supplied by the M/s APL) |
27 | 15 Amp. Piano type. (All materials as required would be supplied by the M/s APL) |
28 | Fixing of new switch boards of the following sizes with existing sockets, regulators etc. and connection |
29 | 100 mm x 100mm. (All materials as required would be supplied by the M/s APL) |
30 | 100 mm x 150mm. (All materials as required would be supplied by the M/s APL) |
31 | 150 mm x 200mm. (All materials as required would be supplied by the M/s APL) |
32 | 200 mm x 250 mm. / 200 mm x 300 mm.(All materials as required would be supplied by the M/s APL) |
33 | 250 mmx 300 mm/ 300 mm x 300. (All materials as required would be supplied by the M/s APL) |
34 | Removing of defective bulb holder and fixing of new one including connections. |
35 | Pendent holder only. (All materials as required would be supplied by the M/s APL) |
36 | Removing of defective one and fixing of new one including connection. |
37 | Calling bell / buzzer on board. (All materials as required would be supplied by the M/s APL) |
38 | Bell push on round block. (All materials as required would be supplied by the M/s APL) |
39 | Dismantling of tube light fitting/LED fitting inside quarter, checking, repairing and refitting in original position with fixing of new |
40 | Choke/Ballast. (All materials as required would be supplied by the M/s APL) |
41 | Starter. (All materials as required would be supplied by the M/s APL) |
42 | Tube holder. (All materials as required would be supplied by the M/s APL) |
43 | Tube. (All materials as required would be supplied by the M/s APL) |
44 | Starter holder. (All materials as required would be supplied by the M/s APL) |
45 | Dismantling of street light fitting , checking, repairing and refitting in original position with fixing of new |
46 | Choke/Ballast. (All materials as required would be supplied by the M/s APL) |
47 | Starter. (All materials as required would be supplied by the M/s APL) |
48 | Tube holder. (All materials as required would be supplied by the M/s APL) |
49 | Tube. (All materials as required would be supplied by the M/s APL) |
50 | Starter holder. (All materials as required would be supplied by the M/s APL) |
51 | Checking & repairing of defective service line, connection in overhead line, meter box etc. |
52 | Removing of defective one & fixing of new ceiling fan regulator. |
53 | Checking and replacing of burnt wire including fuse connection etc. |
54 | Main switch / DB/ Cut out. (All materials as required would be supplied by the M/s APL) |
55 | Complete checking of all electrical systems in quarters including meggering, checking of earth lines, junction box, switch boards, main switch, DB etc. |
56 | Repairing and making good of loose and hanging parts and refitting in original position. |
57 | Portion of batten with wiring. (All materials as required would be supplied by the M/s APL) |
58 | Switch boards with switch, regulators etc. (All materials as required would be supplied by the M/s APL) |
59 | Main switch and board. (All materials as required would be supplied by the M/s APL) |
60 | DB and board. (All materials as required would be supplied by the M/s APL) |
61 | Light fittings. (All materials as required would be supplied by the M/s APL) |
62 | Meter box. (All materials as required would be supplied by the M/s APL) |
63 | Fixing of LED bulbs after removing old fused bulbs. |
64 | 5 watt. (All materials as required would be supplied by the M/s APL) |
65 | 9 watt. (All materials as required would be supplied by the M/s APL) |
66 | 23 watt. (All materials as required would be supplied by the M/s APL) |
67 | Dismantling , cleaning and greasing and refitting of ceiling fan in original position with fixing of condensers etc. |
68 | Providing temporary electrical connection with proper size wire. Service line with |
69 | 4 mm2/6 mm2 wire. (All materials as required would be supplied by the M/s APL) |
70 | 10 mm2 wire. (All materials as required would be supplied by the M/s APL) |
71 | Providing temporary electrical connection with proper size wire. Installing ICDP main switch |
72 | 15 Amp. (All materials as required would be supplied by the M/s APL) |
73 | 30 Amp. (All materials as required would be supplied by the M/s APL) |
74 | Flood light fitting. (All materials as required would be supplied by the M/s APL) |
75 | Connecting 1x40W tube light fitting. (All materials as required would be supplied by the M/s APL) |
76 | Replacing defective plug top (3-pin) |
77 | 5 Amp/15 Amps. (All materials as required would be supplied by the M/s APL) |
78 | Fixing of Choke/Ballast for HPSV lamp. |
79 | 150 Watt (All materials as required would be supplied by the M/s APL) |
80 | 250 Watt (All materials as required would be supplied by the M/s APL) |
81 | Fixing of HPSV ignitor. |
82 | Replacing the existing defective street light fittings and replacing them by new 45 watt LED fittings includingidentifying and rectifying the circuit defects,wiring,cabling as required to make the light working.This job also include shifting of material,ladder etc.from one place to other place as required to execute the job. (All materials as required would be supplied by the M/s APL) |
83 | Replacing the existing defective street light fittings and replacing them by new 85 watt LED fittings includingidentifying and rectifying the circuit defects,wiring,cabling as required to make the light working.This job also include shifting of material,ladder etc.from one place to other place as required to execute the job. (All materials as required would be supplied by the M/s APL) |
84 | Maintenance of D.O.L starter panel of Deep Tube Well including replacement of contactor, switch fuse unit,overload relay,glanding, re-termination of cable etc. and re-energization of panel. (All materials as job also include shifting of material,ladder etc.from one place to other place as required to execute the job. (All materials as required would be supplied by the M/s APL) |
85 | Supply of Manpower arrangement for electrical maintenance in case of exigency |
86 | Skilled |
87 | Semi Skilled |
88 | Complete wiring of Residential Quarters/Office/Public Building |
89 | Supplying and wiring for sub-main with 2x6 Sq.mm. PVC insulated PVC sheathed Aluminium conductor cable in PVC pipe, PVC casing and capping including PVC bends etc. as required.Make:Henly/Arihant/Ajanta |
90 | Supply and circuit wiring with 2x2.5 Sq.mm PVC insulated PVC sheathed Aluminium conductor cable in PVC, PVC casing and capping including PVC bends etc. as required |
91 | Supply and wiring for light, fan and telephone point with 2x2.5 sq.mm PVC insulated PVC sheathed Aluminium conductor including PVC bends etc. as required.Make:Henly/Arihant/Ajanta |
92 | Short Point |
93 | Medium Point |
94 | Supply and drawing of 4mm2 Al-conductor bare wire for loop earthing other wires as required. |
95 | Supplying and placing of bakelite board of the following sizes:Make: Pesto plast or eqivalent |
96 | 4"" x 4" |
97 | 6"" x 4" |
98 | 6"" x 8" |
99 | 8"" x 10" |
100 | Supply and fixing of the following making connections etc. as required.Make: Anchor or eqivalent |
101 | Batten/Angle holder |
102 | Piano type switch of 5 Amps capacity |
103 | Call bell switch |
104 | 3 Pin SS combined 5 Amps capacity |
105 | 3 Pin SS combined 15 Amps capacity |
106 | Ceiling Rose |
107 | PVC Square Box |
108 | Supply, installation, testing and commissioning of LED tubelight fittings as required.Make: Havell"s or equivalent |
109 | Supply & installations of ISI marked coiled type resistance ceiling fan regulators of reputed make as required.Make: Orient or eqivalent |
110 | Supply, fitting and fixing of 4 Way, SPN, MCB, DB with single door made up of CRCA sheet steel powder coated enclosure. All materials are in the scope of the contractor.Make:Havell"s |
111 | Supply, fixing, testing and commissioning with necessary wiring for power supply in outgoing for 240 V, 50 Hz, SP 16A-32A MCB. All materials are in the scope of the contractor.Make:Havell"s |
112 | Supply, fixing, testing and commissioning of 32A Main switch fuse unit. All materials are in the scope of the contractor.Make:Havell"s |
113 | Supply and fixing of call bell. Make:Anchor/Havell"s |
114 | Annual maintenance of LT overhead line/Underground cable of APL Township |
115 | Dismantling of existing PSC Poles and shifting it as directed by the Engineer-In-Charge |
116 | Dismantling of existing Overhead line and shifting it as directed by the Engineer-In-Charge |
117 | Stringing up of different ACSR conductor in LT overhead lines. |
118 | Supplying and erection PSC pole 9.75 meter long, the pole is to be erection in 1:3:6 plain cement concrete foundation of size: 1.50 m x 0.45 m x 0.45 m having P.C.C base foundation 15 cm x 60 cm x 60 cm including edge brick soiling and plastering above G.I portion (0.30 meter complete with excavation of earth handling of surplus soil,debris etc to the proper place and refilling etc as specified and as directed by the Engineer-in-Charge. |
119 | Supplying and erection of LT stay set complete(Galvanize with 19mm dia X 1.8m long stay rod anchor plate of size 30cm X 30cm X 6.4 mm thimble stay clamps tube buckle (19mm X 60c 7/14 Swg dia G.I stay and strain insulation etc in cement concrete 1:3:6 (1 Cement : 3 Course sand : 6 Gradeed Stone aggregate 40mm nominal size foundation including excavation and refilling etc as required and as directed by the Engineer-in-Charge.. |
120 | Supplying and string up ACSR Weasalconductor in the new PSC Pole with binding etc for 3-phase, neutral and street lighting as required and as directed by the Engineer-In-Charge. |
121 | Supplying and string up ACSR Raccoonconductor (75 sqmm ) in thePSC Pole with binding etc for 3-phase, neutral and street lighting as required and as directed by the Engineer-In-Charge. |
122 | Supplying and string up 8mm G.I wire for guard line in the new PSC Pole with binding etc as required and as directed by the Engineer-In-Charge. |
123 | Supplying and string up 8mm G.I wire for guard line in the new PSC Pole with binding and also horizontal between the laid guard line etc as required and as directed by the Engineer-In-Charge. |
124 | Supplying and erection of LT Pin insulators with G.I pin & required clamps complete with bolts and nuts coach screw etc as required and as directed by Engineer-In-Charge. |
125 | Supplying and erection of LT Shackle insulators with shackle strap and required clamps complete with blots and nuts coach screw etc as required and as directed by the department. |
126 | Removal of cradle/hexagonal guard of GI wire No.8 to 4 SWG as required in APL township. |
127 | Supplying and fitting fixing of galvanised angle of 50 mm x 50 mm x 60 x 3 feet long complete with clamps, bolts, nuts etc. as required and as required and as directed by the department. |
128 | Relacement/repairing/attending of jumpers of LT overhead lines as per direction of the site Engineer APL Township. |
129 | Supplying and fitting fixing of galvanised angle of 50 mm x 50 mm x 60 x 2 feet long complete with clamps, bolts, nuts etc. as required and as required and as directed by the department. |
130 | Supply and fixing of 50 mm GI pipe over ground along with the PSC poles |
131 | Supply and laying underground GI pipe of 150 mm for 2 nos of road crosing. Filling back the soil to make convinient for vehicle movement. |
132 | Supply including fitting and fixing of Resin Cast type 3.3KV PVC/XLPE/PILC cable straight through jointing kits(RAYCHEM/3M make) including all accessories for the following sizes including testing and commissioning as specified and directed by site Engineer.Size : 3 coreX (50- 95) mm2, 3.3 KV |
133 | Supply including fitting and fixing of Resin Cast type 1.1KV PVC/XLPE/PILC cable straight through jointing kits(RAYCHEM/3M make) including all accessories for the following sizes including testing and commissioning as specified and directed by site Engineer.Size : 3.5coreX (185-240) mm2, 1.1 KV |
134 | Supply including fitting and fixing of 33KV SCREENED XLPE cables heat shrink type three core HT cable indoor termination kits RAYCHEM RPG including all accessories for the following sizes including testing commissioning as specified and directed by the Engineer-in-charge. Size: 120 Sq.mmto 240 Sq.mm, three core cable. |
135 | Supply including fitting and fixing of Resin Cast type outdoor end cable termination kit for 3 core/3.3 KV XLPE cable including testing and comissioning as specified and directed by the Engineer-in-Charge.Size : 3.5 core x (50-95) mm2 |
136 | Supply including fitting and fixing of Resin Cast type outdoor end cable termination kit for 3 core/3.3 KV XLPE cable including testing and comissioning as specified and directed by the Engineer-in-Charge.Size : 3 core X (120 mm2 - 240 mm2) |
137 | Supply including fitting and fixing of Resin Cast type outdoor end cable termination kit for 3 core/1.1KV XLPE cable including testing and comissioning as specified and directed by the Engineer-in-Charge.Size : 3.5 core x (185-240) mm2 |
138 | Supply including fitting and fixing of Resin Cast type 3.3 KV PVC/XLPE/PILC cable straight through jointing kits(RAYCHEM/3M make) including all accessories for the following sizes including testing and commissioning as specified and directed by site Engineer.Size : 3corex (185-240 )mm2, 3.3 KV |
139 | Supplying,installation,testing and commissioning of street light post made out of 50mm,4.5mm thick dia G.I Pipe of 6.25 Mtrs long along with 2 nos. 25mm dia 1 Mtr. Long Mast arm for fixing the LED Street Light along with P.C.C foundation for grounting the pole duly welded and covering top and bottom etc as complete as required. |
140 | Supplying,installation,testing and commissioning of street light post made out of 50mm,4.5mm thick dia G.I Pipe of 6.25 Mtrs long along with 1 nos. 25mm dia 1 Mtr. Long Mast arm for fixing the LED Street Light along with P.C.C foundation for grounting the pole duly welded and covering top and bottom etc as complete as required. |
141 | Supply and installation of mounting bracket of adequate size for fittingstreet light in the existing polewith all accessories |
142 | Laying of weather proof Aluminium conductor from pole to pole for supply of A.C Voltage for the light including connection etc as per following |
143 | 2 core x 2.5 sq mm (All materials as required would be supplied by the M/s APL) |
144 | 2 core x 4 sq mm (All materials as required would be supplied by the M/s APL) |
145 | Supplying and drawing of 14 SWG G.I. wire from pole to pole for support of the weather proof wire including binding supporting clamp etc. as required |
146 | Providing of spike earth with 4mm G.I. earth pipe electrode of 1.5 Mtr long for body earth for the street light pole including 1 mtr 8 SWG GI wire for continuity from earth pit to pole |
147 | Supply including fitting and fixing of Resin Cast type 3.3 KV PVC/XLPE/PILC cable straight through jointing kits(RAYCHEM/3M make) including all accessories for the following sizes including testing and commissioning as specified and directed by site Engineer.Size : 120 Sq.mmto 240 Sq.mm, three core cable. |