Repair And Maintenance Of Pumping Machineries, Cleaning Of Ug Sumps Oh Reservoirs And Maintenance Of Amf Panels Fire Fighting Etc Under Ge I Navy Jamnagar R, jamnagar-Gujarat

Military Engineer Services-MES has published Repair And Maintenance Of Pumping Machineries, Cleaning Of Ug Sumps Oh Reservoirs And Maintenance Of Amf Panels Fire Fighting Etc Under Ge I Navy Jamnagar R. Submission Date for this Tender is 22-10-2022. Electrical Panel Tenders in jamnagar Gujarat. Bidders can get complete Tender details and download the document.




Tender Notice

34111730
Corrigendum : Repair And Maintenance Of Pumping Machineries, Cleaning Of Ug Sumps Oh Reservoirs And Maintenance Of Amf Panels Fire Fighting Etc Under Ge I Navy Jamnagar R
Open Tender
Indian
Gujarat
jamnagar
22-10-2022

Tender Details

Repair And Maintenance Of Pumping Machineries, Cleaning Of Ug Sumps Oh Reservoirs And Maintenance Of Amf Panels Fire Fighting Etc Under Ge I Navy Jamnagar R

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-Oct-2022 Corrigendum to Tender BOQ BOQ 15-10-2022
2 15-Oct-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-10-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

BOQ Items

Name of Work:REPAIR AND MAINTENANCE OF PUMPING MACHINERIES, CLEANING OF UG SUMPS/ OH RESERVOIRS AND MAINTENANCE OF AMF PANELS, FIRE FIGHTING ETC UNDER GE (I) NAVY JAMNAGAR
Sl. No. Item Description
1Excavation in trenches and not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation of drain, man hole, laying ofcables, stay etc. not exceeding 10 Sq. m on plan and not exceeding 1.5 m depth and getting out in soft / loose soil.
2Returning filling in trenches including spreading, leveling,watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
3Removing excavated surplus soil to a distance not exceeding 50 mts and depositing where directed .at a level not exceeding 1.5 M above the starting point complete all as directed.
4M&L for PCC 1:3:6, type C1 (using 20 mm graded crushed granite stone aggregate) as in coping including necessary form work complete all as directed.
5M&L for brick work with fly ash bricks, straight or curved on plan exceeding 6 m mean radius built in CM 1:4 complete all as specified including demolition of existing brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc and removal of debris to a distance not exceeding 50 mts and depositing where directed.
6M&L for rendering 10 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished fair and even andfinally apply three coats of white wash on plastered surface complete all as directed. Note: Quoted rate shall deemed to be inclusive of three coats of white wash.
7M&L M-35 grade, 60 mm thick PVC moulded machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment conforming to IS: 15658-2006, laid over and including 40 mm thick compacted sand cushion as per manufacturer"s instructions complete all as directed..(Note : Quoted rate is deemed tobe inclusive ofsand cushoining).
8Taking down/up the existing submersible pump set of capacity 3 to 5 HP from underground sump, well, transporting to work shop, dismantling the submersible pump set, cleaning descaling and re-assembling after repair/ replacement of spare parts including taking out pipe, cable etc. and lowering, fixing at the same/ new location complete all as directed. Note: Cost of new spare parts and rewinding shall be measured and paid separately under relevant items of BOQ under .
9All as per item No. 8 here in above, but for 7.5 to 10 HP. Note: Cost of new spare parts and rewinding shall be measured and paid separately under relevant items of BOQ under .
10All as per item No. 8 here in above, but for 15 to 25 HP. Note: Cost of new spare parts and rewinding shall be measured and paid separately under relevant items of BOQ under .
11All as per item No. 8 here in above, but for 30 HP. Note: Cost of new spare parts and rewinding shall be measured and paid separately under relevant items of BOQ under .
12Supply only new Pump Shaft for 3 to 5 HP of submersible pump and motor as per existing type.
13Supply only new Pump Stage CI thrust for 3 to 5 HP submersible pump and motor as per existing type.
14Supply only new Pump stage CI thrust casing for 3 to 5 HP submersible pump and motor as per existing type.
15Supply only new Cast Iron impeller for 3 to 5 HP submersible pump and motor as per existing type.
16Supply only new Neck ring brass for 3 to 5 HP submersible pump and motor as per existing type.
17Supply only new Pump Rubber bush for 3 to 5 HP submersible pump and motor as per existing type.
18Supply only new Pump metal bush for 3 to 5 HP submersible pump and motor as per existing type.
19Supply only new SS sleeves for 3 to 5 HP submersible pump and motor as per existing type.
20Supply only new Pump cupple for 3 to 5 HP submersible pump and motor as per existing type.
21Supply only new pump key stage wise for 3 to 5 HP of submersible pump and motor as per existing type.
22Supply only new motor bush for 3 to 5 HP submersible pump and motor as per existing type.
23Supply only new shafting turnning and granding for 3 to 5 HP submersible pump and motor as per existing type.
24Supply only new CI thrust bearing for 3 to 5 HP submersible pump and motor as per existing type.
25Supply only new CI stage casing for 3 to 5 HP submersible pump and motor as per existing type.
26Supply only new Motor cupple for 3 to 5 HP submersible pump and motor as per existing type.
27Supply only new motor upper housing for 3 to 5 HP submersible pump and motor as per existing type.
28Supply only new motor lower housing for 3 to 5 HP submersible pump and motor as per existing type.
29Supply only new motor base thrust cover for 3 to 5 HP submersible pump and motor as per existing type.
30Supply only new motor and pump connecting piece for 3 to 5 HP of submersible pump and motor as per existing type.
31Supply only new Pump Shaft for 7.5 to 10 HP of submersible pump and motor as per existing type.
32Supply only new Pump Stage CI thrustfor 7.5 to 10 HP submersible pump and motor as per existing type.
33Supply only new Pump stage CI thrust casing for 7.5 to 10 HP submersible pump and motor as per existing type.
34Supply only new Cast Iron impeller for 7.5 to 10 HP submersible pump and motor as per existing type.
35Supply only new Neck ring brass for 7.5 to 10 HP submersible pump and motor as per existing type.
36Supply only new Pump Rubber bush for 7.5 to 10 HP submersible pump and motor as per existing type.
37Supply only new Pump metal bush for 7.5 to 10 HP submersible pump and motor as per existing type.
38Supply only new SS sleeves for 7.5 to 10 HP submersible pump and motor as per existing type.
39Supply only new Pump cupple for 7.5 to 10 HP submersible pump and motor as per existing type.
40Supply only new pump key stage wise for 7.5 to 10 HP of submersible pump and motor as per existing type.
41Supply only new motor bush for 7.5 to 10 HP submersible pump and motor as per existing type.
42Supply only new shafting turnning and granding for 7.5 to 10 HP submersible pump and motor as per existing type.
43Supply only new CI thrust bearing for 7.5 to 10 HP submersible pump and motor as per existing type.
44Supply only new CI stage casing for 7.5 to 10 HP submersible pump and motor as per existing type.
45Supply only new Motor cupple for 7.5 to 10 HP submersible pump and motor as per existing type.
46Supply only new motor upper housing for 7.5 to 10 HP submersible pump and motor as per existing type.
47Supply only new motor lower housing for 7.5 to 10 HP submersible pump and motor as per existing type.
48Supply only new motor base thrust cover for 7.5 to 10 HP submersible pump and motor as per existing type.
49Supply only new motor and pump connecting piece for 7.5 to 10 HP of submersible pump and motor as per existing type.
50Supply only new Pump Shaft for 15 to 25 HP of submersible pump and motor as per existing type.
51Supply only new Pump Stage CI thrustfor 15 to 25 HP submersible pump and motor as per existing type.
52Supply only new Pump stage CI thrust casing for 15 to 25 HP submersible pump and motor as per existing type.
53Supply only new Cast Iron impeller for 15 to 25 HP submersible pump and motor as per existing type.
54Supply only new Neck ring brass for 15 to 25 HP submersible pump and motor as per existing type.
55Supply only new Pump Rubber bush for 15 to 25 HP submersible pump and motor as per existing type.
56Supply only new Pump metal bush for 15 to 25 HP submersible pump and motor as per existing type.
57Supply only new SS sleeves for 15 to 25 HP submersible pump and motor as per existing type.
58Supply only new Pump cupple for 15 to 25 HP submersible pump and motor as per existing type.
59Supply only new pump key stage wise for 15 to 25 HP of submersible pump and motor as per existing type.
60Supply only new motor bush for 15 to 25 HP submersible pump and motor as per existing type.
61Supply only new shafting turnning and granding for 15 to 25 HP submersible pump and motor as per existing type.
62Supply only new CI thrust bearing for 15 to 25 HP submersible pump and motor as per existing type.
63Supply only new CI stage casing for 15 to 25 HP submersible pump and motor as per existing type.
64Supply only new Motor cupple for 15 to 25 HP submersible pump and motor as per existing type.
65Supply only new motor upper housing for 15 to 25 submersible pump and motor as per existing type.
66Supply only new motor lower housing for 15 to 25 HP submersible pump and motor as per existing type.
67Supply only new motor base thrust cover for 15 to 25 HP submersible pump and motor as per existing type.
68Supply only new motor and pump connecting piece for 15 to 25 HP of submersible pump and motor as per existing type.
69Supply only new Pump Shaft for 30 HP of submersible pump and motor as per existing type.
70Supply only new Pump Stage CI thrustfor 30 HP submersible pump and motor as per existing type.
71Supply only new Pump stage CI thrust casing for 30 HP submersible pump and motor as per existing type.
72Supply only new Cast Iron impeller for 30 HP submersible pump and motor as per existing type.
73Supply only new Neck ring brass for 30 HP submersible pump and motor as per existing type.
74Supply only new Pump Rubber bush for 30 HP submersible pump and motor as per existing type.
75Supply only new Pump metal bush for 30 HP submersible pump and motor as per existing type.
76Supply only new SS sleeves for 30 HP submersible pump and motor as per existing type.
77Supply only new Pump cupple for 30 HP submersible pump and motor as per existing type.
78Supply only new pump key stage wise for 30 HP of submersible pump and motor as per existing type.
79Supply only new motor bush for 30 HP submersible pump and motor as per existing type.
80Supply only new shafting turnning and granding for 30 HP submersible pump and motor as per existing type.
81Supply only new CI thrust bearing for 30 HP submersible pump and motor as per existing type.
82Supply only new CI stage casing for 30 HP submersible pump and motor as per existing type.
83Supply only new Motor cupple for 30 HP submersible pump and motor as per existing type.
84Supply only new motor upper housing for 30 submersible pump and motor as per existing type.
85Supply only new motor lower housing for 30 HP submersible pump and motor as per existing type.
86Supply only new motor base thrust cover for 30 HP submersible pump and motor as per existing type.
87Supply only new motor and pump connecting piece for 30 HP of submersible pump and motor as per existing type.
88M&L cutting out the burnt winding of all the three phases of stator, for submersible pump set of capacity 3 to 5 HP, taking out burn out copper wire by cleaning the slots properly, re-winding the three phases with original gauge, super enamaled the copper winding wire including insulating material i.e. varnishing, cotton tape, insulating paper, sleeves drying the winding with required temperature re-assembling the rotor and stator after cleaning and dusting of rotor to remove the settled dust particles complete all as directed.
89All as per item No. 88here in above, but for 7.5 to 10 HP
90All as per item No. 88 here in above, but for 15 to 25 HP
91All as per item No. 88 here in above, but for 30 HP
92Disconnecting the single stage split casing centrifugal pumping set / Monoblock pumping set, 60 HP (any make), separating from sunction, delivery pipeline, electrical connection etc. dismantling the same including transporting to civil workshop(without any extra cost toGovt) for overhauling, repairing and replacing the unserviceable spare parts such as gland, packing, bearing bush, washer etc. Painting with one coat of synthetic enamel paint with proper colour codes and writing letters of SM No. and MES No. etc. and installing, making connection suction and delivery side with necessary new packing material, nut bolt etc. complete all as specified and as directed.
93All as per item No. 92 here in above, but for the single stage split casing centrifugal pumping set / Monoblock pumping set 40 HP.
94All as per item No. 92 here in above, but for the single stage split casing centrifugal pumping set / Monoblock pumping set 10 to 15 HP.
95All as per item No. 92 here in above, but for the single stage split casing centrifugal pumping set / Monoblock pumping set 3 to 7.5 HP. Note for itemNo 92 to 95 : Cost of new spare parts shall be measured and paid separately under relevant items of BOQ under.
96Supply only new Cast Iron impeller for 60 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
97Supply only new Key of impeller for 60 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
98Supply only new pump shaft made of EN9 steel for 60 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
99Supply only new gun metal bush for 60 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
100Supply only new Cast Iron gland flange for 60 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
101Supply only new ball bearing for pump of 60 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
102Supply only new love joy coupling for 60 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
103Supply only new ball bearing for motor of 60 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
104Supply only new Sleeves Cover for motor of 60 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
105Supply only new Motor shaft for 60 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
106Supply only new Cast Iron impeller for 40 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
107Supply only new Key of impeller for 40 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
108Supply only new pump shaft made of EN9 steel for 40 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
109Supply only new gun metal bush for 40 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
110Supply only new Cast Iron gland flange for 40 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
111Supply only new ball bearing for pump of 40 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
112Supply only new love joy coupling for 40 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
113Supply only new ball bearing for motor of 40 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
114Supply only new Sleeves Cover for motor of 40 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
115Supply only new Motor shaft for 40 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
116Supply only new Cast Iron impeller for 10 to 15 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
117Supply only new Key of impeller for 10 to 15 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
118Supply only new pump shaft made of EN9 steel for 10 to 15 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
119Supply only new gun metal bush for 10 to 15 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
120Supply only new Cast Iron gland flange for 10 to 15 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
121Supply only new ball bearing for pump of 10 to 15 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
122Supply only new love joy coupling for 10 to 15 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
123Supply only new ball bearing for motor of 10 to 15 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
124Supply only new Sleeves Cover for motor of 10 to 15 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
125Supply only new Motor shaft for 10 to 15 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
126Supply only new Cast Iron impeller for 3 to 7.5 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
127Supply only new Key of impeller for 3 to 7.5 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
128Supply only new pump shaft made of EN9 steel for 3 to 7.5 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
129Supply only new gun metal bush for 3 to 7.5 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
130Supply only new Cast Iron gland flange for 3 to 7.5 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
131Supply only new ball bearing for pump of 3 to 7.5 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
132Supply only new love joy coupling for 3 to 7.5 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
133Supply only new ball bearing for motor of 3 to 7.5 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
134Supply only new Sleeves Cover for motor of 3 to 7.5 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
135Supply only new Motor shaft for 3 to 7.5 HP single stage split casing cenrifugal pumping set / monoblock pumping set as per existing type.
136M&L cutting out the burnt winding for 40-60 HP electric induction motor three phase stator, taking out burn out copper wire by cleaning the slots properly, re-winding the same as per original gauge, super enamelled the copper winding wire including insulating material i.e. varnishing, cotton tape, insulating paper, sleeves drying the winding with required temperature re-assembling the rotor and stator after cleaning complete all as specified and as directed.
137All as per item No. 136 here in above, but for 10 to 15 HP electric induction motor three phase stator.
138All as per item No. 136 here in above, but for 3 to 7.5 HP electric induction motor three phase stator.
139M&L painting to motors, pump sets, MS channels, foundations, suction and delivery pipes of 30 to 60 HP pump sets up to 5m length from pump sets including cleaning the outer surfaces of any description, in any position, applying one coat of synthetic enamel paint with proper colour codes and writing letters of SM No. and MES No. etc., complete all as specified and as directed.
140All as per item No. 139 here in above, but for 10 to 25 HP pump sets.
141M&L for painting to CI pipe lines of any size fixed for OHT. Inlet, Outlet, Overflow, washout MS ladder with cleaning the outer surface of pipes, ladder with wire brush complete. Applying two coats of anti corrossive synthetic paint over one coat as primer complete all as water supply colour code system as specified and directed by Engr-in-Charge for Over Head Tank Nos. 1, 2, 3,4, 5, 6,7, 8, 9 & 10
142S&F in repair MCCB, 4 pole, 250 Amps, 36 kA,415 Volts,50 Hz, AC including electric connection & testing complete all as specified and as directed. Make: Legrand/ Schneider/ L&T/ ABB/ Siemens
143S&F in repair MCCB 4 pole, 200 Amps, 36 kA,415 Volts,50 Hz, AC including electric connection & testing complete all as specified and as directed. Make: Legrand/ Schneider/ L&T/ ABB/ Siemens
144S&F in repair MCCB 4 pole, 160 Amps, 25 kA,415 Volts,50 Hz, AC supply including electric connection & testing complete all as specified and as directed. Make: Legrand/ Schneider/ L&T/ ABB/ Siemens
145S&F in repair MCCB 4 pole, 100 Amps, 25 kA,415 Volts, 50 Hz, AC supply including electric connection & testing complete all as specified and as directed. Make: Legrand/ Schneider/ L&T/ ABB/ Siemens
146S&F single phase preventer & dry run protection relay (current based), AC, 415 V including commissioning & testing including taking down existing unservicable single phase preventer complete all as specified. Make: Minilec / L&T / C&S
147S&F contactors ML-3 includingtaking out existing unseviceable contractor including electrical connection complete all as specified and as directed. Make: Legrand / Schneider / L&T / ABB / Siemens
148M&L submersible cable copper conductor size of 3 core, 16 sqmm, flat, multistranded and waterproof including taking down unservicablecable complete all as specified and as directed.
149All as per Item No. 148 here in above, but of size 3 Core, 10 Sqmm
150All as per Item No.148 here in above, but of size 3 Core, 6 Sqmm
151All as per Item No. 148 here in above, but of size 3 Core, 4 Sqmm
152Supply and lay in repairs High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 laid in trenches 50 mm bore for protection of submersible cable in trenches including all necessary fittings complete all as specified and as directed. Note: Earth work and excavation shall measured and paid separately.
153S&F motor backlite terminal plate having six terminal as per existing size / shape with copper alloy nuts, bolts and washers for 40/ 60 HP motor including taking down unservicable terminal plate complete all as specified.
154M&L for repairing cast iron sluice valve 80 mm bore flanged type of any make by dismantling the valve, replacing SS spindle, bolts, nuts, washers, gaskets, wedgenut etc, re-assembling and refixing the same in position including replacing the worn out gland packing & testing and make good complete all as specified and as directed.
155All as per Item No. 154 above here in, but sluice valve 100 mm bore.
156All as per Item No. 154 above here in, but sluice valve 150 mm bore.
157All as per Item No. 154 above here in, but sluice valve 200 mm bore.
158All as per Item No. 154 above here in, but sluice valve 250 mm bore.
159All as per Item No. 154 above here in, but sluice valve 300 mm bore.
160Taking down existing sluice valve and S&F sluice valve cast iron body, double flanged and drilled, 80 mm bore as per IS-14846, class PN-1.6, long body type with SS spindle etc with all fittings, jointing materials etc. complete all as specified and as directed.
161All as per Item No. 160 here in above, but 100 mm bore.
162All as per Item No. 160here in above, but 150 mm bore.
163S&F in repairs Non return valve cast iron body with nitrile rubber ball as per IS-5312, class PN-1.6, double flange with reinforced ball suitable for 80 mm bore complete.
164S&F in repairs Non return valve cast iron body with nitrile rubber ball as per IS-5312, class PN-1.6, double flange with reinforced ball suitable for 100 mm bore complete.
165S&F in repairs Non return valve cast iron body with nitrile rubber ball as per IS-5312, class PN-1.6, double flange with reinforced ball suitable for 150 mm bore complete.
166S&F in repairs CI foot valve flanged and drilled type with ISI marked conforming to IS:1538 of 80 mm bore complete all as directed.
167S&F in repairs CI foot valve flanged and drilled type with ISI marked conforming to IS:1538 of 100 mm bore complete all as directed.
168S&F in repairs CI foot valve flanged and drilled type with ISI marked conforming to IS:1538 of 150 mm bore complete all as directed.
169S&F in repair fully automatic DOL motor starter in sheet steel enclosure for 3 to 5 HP with SPP feature complete including disconnecting and reconnecting by using proper lugs complete. Make: L&T ModelNo. MK1 DOL or equivalent in Siemens / Schneider / C&S.
170S&F in repair fully automatic DOL motor starter in sheet steel enclosure for7.5 to 15 HP with SPP feature complete including disconnecting and reconnecting by using proper lugs complete. Make: L&T ModelNo. MK1 SASD or equivalent in Siemens / Schneider / C&S.
171S&F in repair fully automatic star Delta motor starter in sheet steel enclosure for 25 to 30 HP with SPP feature complete including disconnecting and reconnecting by using proper lugs complete. Make: L&T ModelNo. MUG-30 FASD or equivalent in Siemens / Schneider / C&S.
172S&F in repair fully automatic star Delta motor starter in sheet steel enclosure for 40 to 60 HP with SPP feature complete including disconnecting and reconnecting by using proper lugs complete. Make: L&T ModelNo. MUG-50FASD or equivalent in Siemens / Schneider / C&S.
173Pumping out the water from under ground sump of size 24.80x16.45x5.30 m and capacity 2,00,000 Gallons and remove sludge / mud thoroughly, clean entire portion of sump by scrapping with wire brushes, broom and wash out by flushing clean water and drain out, clean entire inner portion of sump by bleaching powder, and apply one coat of white wash on inner surfaces of sump, at Pump House No.1 including marking the Date of cleaning, due date for next cleaning and capacity of sump etc with painting complete all as specified. Note for Sl item No. 173 to 178: i)Contractor has to make his own arrangements for Pumping out the water from Sump including T&P and necessary safety measures for cleaning of sump.ii)Job is to be carried out in one day.
174All as per Item No. 173 here in above, but size of sump 24.40x15.25x4.30 m, and of capacity 1,50,000 Gallons at Pump House No. 1.
175All as per Item No. 173 here in above, but size of sump 17.50x15.50x5.50 m, and of capacity 1,25,000 Gallons at Pump House No. 1.
176All as per Item No. 173 here in above, but size of sump 16.50x15.50x5.30 m, and of capacity 1,00,000 Gallons at Pump House No. 2.
177All as per Item No. 173 here in above, but size of sump 5.90x5.90x2.20 m, and of capacity 10,000 Gallons at NEMCC
178All as per Item No. 173 here in above, but size of sump 6.50x6.50x2.20 m, and of capacity 15,000 Gallons at Pump House No. 1 (For RO Plant)
179Drain out water from Over Head Tank (OHT) capacity 1,00,000 gallons at 18.3 m height from ground andremove the sludge / mud thoroughly, clean inner surface of the tank by scrapping with wire brush, broom and wash out by flushing with clean water and drain out for OHT No. 6 & OHT No. 3. Note for Sl item No. 179 to 182: i)Contractor has to make his own arrangements for Pumping out the water from OHT including T&P and necessary safety measures for cleaning of OHT.
180All as per Item No. 179 here in above, but tank capacity 50,000 gallons at 18.30 m height from ground (OHT No. 1, 2, 5, 7, 9 & 10).
181All as per Item No. 179 here in above, but tank capacity 25,000 gallons at 18.30 m height from ground (OHT No. 4).
182All as per Item No. 179 here in above, but tank capacity 10,000 gallons at 18.50 m height from ground (OHT No. 8)
183Pumping out the water from static water under ground sump capacity 25,000 gallons and remove sludge/ mud thoroughly, clean entire portion of sump by scrapping with wire brushes, brooming and wash out by flushing clean water and drain out, clean entire inner portion of sump by bleaching powder, apply one coat of cement slurry wash to inner surface of sumps, at various location including marking the Date ofcleaning and due date for next cleaning and capacity of sump etc by painting complete all as specified. Note for Sl item No. 183 to 186: i)Contractor has to make his own arrangements for Pumping out the water from static water under ground sump including T&P and necessary safety measures for cleaning of static water under ground sump. Location: Valsura area.
184All as per Item No. 183 here in above, but for 20,000 gallons.
185All as per Item No. 183 here in above, but for 15,000 gallons.
186All as per Item No. 183 here in above, but for 10,000 gallons.
187M&L for valve chamber structure/ supports, base frames, MS sheet, structural steel including hinges duly fabricted and painting with two coats of first quality synthetic enamel paint over a coat of zinc chromate primer including taking down existing itmes etc complete all as specified. Note: Quoted rate shall deemed to be inclusive of painting.
188M&L for earthing complete with galvanized steel earth plate as electrode 600x600x6 mm buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected using galvanized iron earth lead strip 25x4 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead strip protected by Gl light grade pipe 40 mm bore, including provision of concrete pit of PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) with 40 mm thick cover of RCC 1:2:4 reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, char coal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal ofsurplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3of SSR Part I and connected to earth test point complete all as specified including testing on completion and including taking down existing earthing complete.
189M&L for galvanised iron strip 32 x 6mm buried in ground/ wall including taking down existing strip complete.
190S&F in repair Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hex. head screw complete.
191S&F CI/ DI pipe fittings bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs etc. for 80 mm to 300 mm pipe line including taking down existing old CI/ DI pipe fittings complete.
192S&F in repair ammeter digital, panel board mounting square type range 0 to 150 and 200 Amps, CT ratio 200/5 complete.
193S&F in repair Volt meter digital type, panle board mounting square type range 0 to 500 Volts complete.
194S&F in repair LED indicator lamp, RYB 230 volts AC.
195S&F in repair gland packing rope with lead graphite type of size 6 mm to 40 mm.
196S&F Insulating fine ribbed electrical rubber mat 1 x 2mtr, thickness of 6mm of class 0, working voltage of 1100 Volts complete all as directed.
197M&L to attend "B" check for DG set of capacity 63 kVA (Make:Greaves) at different locations to carry out maintenance/servicing as given below once during the contract period as ordered including testing on completion of the following all as directed:- (i) Check and clean engine, alternator battery, instrument panel, AMF panel, Timer,Contactors, Meters and others etc. (ii) Tightening of all nuts & bolts of DG set and its accessories. (iii) Check for any diesel lekage from any point and rectify if observed. (iv) Check and adjust fan belt tension, replace the fan belts if found damaged. (v) Check leakage of smoke from exhaust system/ silencer, Repair if required. (vi) Check electrical connections of engine. The wiring shall be maintened properly and engine starting system from engine instrument panel is to be kept in order. (vii) Check and tighten the AVM pads nuts and bolts, change AVM pads if found damaged. (viii) Check exhaust pipe, flange and lagging Repair if found damaged. (ix) Check output of alternator, if found OK adjust the same to specified values in case of brush type. (x) Checking of all hoses and cleanup, if required. (xi) Oiling, Greasing and checking for proper & smooth functioning. (xii) Change of Air filter element with O ring. (xiii) Change of filter insert with O ring (xiv) Change of Lub oil filter. (xv) Change of Primary filter element. (xvi) Change of secondary filter element. (xvii) Change of greaves lub oil CI4- 10ltrs pack (xviii) Change of Radiator pre-mix greaves kOOL 10 ltrs, complete to the satisfaction of Engr -in-charge. (Note: Cost of New minor spares required for replacement to make the DG set fully functional is included in quoted rate.)
198All same as per item No. 197 here-in-above, but DG set of capacity 100 kVA Make: Greaves
199All same as per item No. 197 here-in-above, but twice during the contract period and change of greaves Lub oil CI4- 20Ltrs pack complete for DG set of capacity 160 kVA Make: Greaves
200All same as per item No. 197 here-in-above, but twice during the contract period and change of greaves Lub oil CI4- 20Ltrs pack complete for DG set of capacity 250 kVA Make: Greaves
201M&L and attend "B" check for DG set of capacity 15 kVA (Make: Kirloskar) at different locations to carry out maintenance/servicing as given below once during the contract period as & when ordered including testing on completion of the following all as directed (i) Check and clean engine, alternator battery, instrument panel, AMF panel, Timer, Contactors, Meters and others etc.(ii) Tightening of all nuts & bolts of DG set and its accessories. (iii) Check for any diesel lekage from any point and rectify if observed. (iv) Check and adjust fan belt tension, replace the fan belts if found damaged. (v) Check leakage of smoke from exhaust system/ silencer, Repair if required. (vi) Check electrical connections of engine. The wiring shall be maintened properly and engine starting system from engine instrument panel is to be kept in order. (vii) Check and tighten the AVM pads nuts and bolts, change AVM pads if found damaged. (viii) Check exhaust pipe, flange and lagging, Repair if found damaged. (ix) Check output of alternator, if found OK adjust the same to specified values in case of brush type. (x) Checking of all hoses and cleanup, if required. (xi) Oiling, Greasing and checking for proper & smooth functioning (xii) Change of Spinon Lub oil filter (xiii) Change of air cleaner element (xiv) change of Belt- AVX 10 1500 (xv) Change of fuel filter element (xvi) Change of KOEL care premium genuine oil 7.5Ltrs Can, complete all as specified and directed by Engr-in-charge. (Note: Cost of New spares required for replacement is included and no seperate payment for minor spares if any reqd, will be made on this account to contractor.)
202All same as per item No. 201 here-in-above, but change of V Belt cogged- AVX10 1265L blower pulley, Change of V Belt cogged-AVX10 1136 for alternator pulley and Change of KOEL care premium genuine oil 13Ltrs Can, complete for DG set of capacity 40 kVA Make: Kirloskar
203M&L and attend "C" check for DG set of capacity 63 kVA (Make: Greaves) at different locations to carry out maintenance/servicing as given below once during the contract period as & when ordered including testing on completion of the following all as directed: (i) Check and clean engine, alternator battery, instrument panel, AMF panel, Timer, Contactors, Meters and others etc. (ii) Tightening of all nuts & bolts of DG set and its accessories. (iii) Check for any diesel lekage from any point and rectify if observed. (iv) Check and adjust fan belt tension, replace the fan belts if found damaged. (v) Check leakage of smoke from exhaust system/silencer, Repair if required. (vi) Check electrical connections of engine. The wiring shall be maintened properly and engine starting system from engine instrument panel is to be kept in order. (vii) Check and tighten the AVM pads nuts and bolts, change AVM pads if found damaged. (viii)Check exhaust pipe, flange and lagging Repair if found damaged. (ix) Check output of alternator, if found OK adjust the same to specified values in case of brush type. (x) Checking of all hoses and cleanup, if required. (xi) Oiling, Greasing and checking for proper & smooth functioning (xii) Change of Gskt set 4G11TA (w/o Hd gskt) (xiii) Change of cogged belt AX43-1143L (xiv) change of pipe turbo oil supply (xv) Change of pipe turbo drain (xvi) Change of set of hoses for 4G valve (xvii) Change of setting screw (xviii) Change of hex nut M8x1 DIN934 (xix) Change of gasket for PDC rocker cover (xx) Change of set of flex F/P (xxi) Change of push rod. (Note: Cost of New spares required for replacement is included and no seperate payment for minor spares if any reqd will be made on this account to contractor.)
204All same as per item No. 203 here-in-above, but DG set of capacity 100 kVA Make: Greaves
205M&L and attend "C" check for DG set of capacity 15 kVA (Make: Kirloskar) at different locations to carry out maintenance/servicing as given below once during the contract period as & when ordered including testing on completion of the following all as directed:(i) Check and clean engine,alternator battery,instrument panel,AMF panel,Timer,Contactors,Meters and others etc. (ii) Tightening of all nuts& bolts of DG set and its accessories.(iii)Check for any diesel lekage from any point and rectify if observed.(iv) Check and adjust fan belt tension ,replace the fan belts if found damaged. (v) Check leakage of smoke from exhaust system/silencer,Repair if required. (vi)Check electrical connections of engine .The wiring shall be maintened properly and engine starting system from engine instrument panel is to be kept in order. (vii)Check and tighten the AVM pads nuts and bolts,change AVM pads if found damaged. (viii)Check exhaust pipe,flange and lagging Repair if found damaged. (ix) Check output of alternator ,if found OK adjust the same to specified values in case of brush type.(x) Checking of all hoses and cleanup, if required. (xi)Oiling,Greasing and checking for proper & smooth functioning(xii) Change of rocker cover gasket (xiii) Change of valve seat insert inlet & exhaust (xiv) change of valve pair inlet & exhaust (xv) Change of set of joints (xvi) Change of set of O rings HA294 (xvii) Change of intermediate ring 1.1mm (xviii) Change of valve guide (xix) Change of valve stem seal , complete all as specified and directed by Engr -in-charge. (note :- Cost of New spares required for replacement is included and no seperate payment for minor spares if any reqd, will be made on this account to contractor. )
206All same as per item No. 205 here-in-above, but for DG set of capacity 40 kVA Make: Kirloskar
207Supply only set of hoses with clipsfor DG set of capacity 63/ 100 kVA Make: Greaves
208Supply only set of fuel pipes for DG set of capacity 63/ 100 kVA Make: Greaves
209Supply only set of injector pipes for DG set of capacity 63/ 100 kVA Make: Greaves
210Supply only Exhaust silencer for DG set of capacity 63/ 100 kVA Make: Greaves
211Supply only injector with nozzle for DG set of capacity 63/ 100 kVA Make: Greaves
212M&L for greaves lubricating oil SAE 15W40 suitable for DG Set.
213M&L for Coolant suitable for DG sets make Fleetguard, Valvoline, Premium
214Supply only Air filter outer for DG set of capacity 63/ 100 kVA Make: Greaves
215Supply only Air filter inner for DG set of capacity 63/ 100 kVA Make: Greaves
216Supply only 12V temp guage (40-120 deg cel) for DG set of capacity 63/ 100 kVA Make: Greaves
217Supply only 12V press guage, 0-10 bar for DG set of capacity 63/ 100 kVA Make: Greaves
218Servicing and caliberation of FIP (Fuel injection pump) & nozzles including replacement of minor parts like nuts,bolts,washers etc of following :-DG Set 63/100 KVA capacity
219M&L for taking out Radiator of DG set 63 kVA/100 kVA Make: Greaves for repair, welding, brazing, leak testing & refixing to DG set to its original position and testing complete all as directed.
220M&L for taking out Radiator of DG set 160 kVA/250 kVA Make: Greaves for repair, welding, brazing, leak testing & refixing to DG set to its original position and testing complete all as directed.
221Servicing & repair to self starter of DG set of capacity 15/40 kVA (Make: Kirloskar) including replacement of parts such as washer, nut, bolts, bush, solenoid, rotor etc. assembling and testing complete.
222All same as per item No 221 here-in-above, but for DG set of capacity 63/100 kVA Make: Greaves
223All same as per item No 221 here-in-above, but for DG set of capacity 160/250 kVA Make: Greaves
224S&F in repair Solonid Switch for 15/ 40 kVA DG set Make: Kirlosakar and testing complete for proper functioning.
225S&F in repair Solonid Switch for 63/ 100 kVA DG set Make: Greaves and testing complete for proper functioning.
226S&F in repair Relay card for 15/ 40 kVA DG set Make: Kirlosakar and testing complete for proper functioning.
227S&F in repair Relay card for 63/ 100 kVA DG set Make: Greaves and testing complete for proper functioning.
228S&F in repair Solonid Switch for 160/250 kVA DG set Make: Greaves and testing complete for proper functioning.
229S&F in repair AVR suitable for 15 kVA DG Set complete all as directed.
230S&F in repair AVR suitable for 40 KVA DG Set complete all as directed.
231S&F in repair AVR suitable for 63 KVA DG Set complete all as directed.
232S&F in repair AVR suitable for 100 KVA DG Set complete all as directed.
233S&F in repair AVR suitable for 160 KVA DG Set complete all as directed.
234S&F in repair AVR suitable for 250 KVA DG Set complete all as directed.
235S&F in repair battery auto cable copper PVC insulated unsheathed 35 Sqmm single core copper cable complete.
236S&F in repair battery auto cable copper PVC insulated unsheathed 95 sqmm single core copper cable complete.
237S&F 90AH 12Volt Lead acid battery (Maintenance free battery with min 2 years warranty) for DG set. Make: Exide Xpress
238S&F 150AH 12Volt 12Volt Lead acid battery (Maintenance free battery with min 2 years warranty) for DG set. Make: Exide Gold
239S&F battery lugs for DG set battery complete all as directed by Engr in charge.
240S&F in repair Ignition Switch of DG Sets & complete all as directed.
241S&F in repair No volt coil for contactor of capacity up to 200 Amp Capacity all as specified and as directed by EIC. Make : L&T /C&S/Schneider
242S&F in repair LED type pilot lamp.Make: C&S / L&T
243S&F in repair selector switchin existing panel all as directed.
244S&F in repair Volt meter 0-500Volt in existing panel includingwiring from bus bar to volt meter terminalsiand fix the wiring wit existing control wiring all as directed. Make: L&T/ Meco/ HPL
245S&F in repair Ammeter 0-100 Amp in existing panel with necessary wiring from CT to Ammeter and fix the wiring in existing set of control wiring all as directed. Make: L&T/ Meco/ HPL
246S&F in repair Ammeter 0-200 Amp in existing panel with necessary wiring from CT to Ammeter and fix the wiring in existing set of control wiring all as directed. Make: L&T/ Meco/ HPL
247S&F in repair electronic timer of215/240/360/415 Volt 3 to 120 Sec all as directed. Make: L&T/C&S/Schneider
248M&L for wiring loom of control panel ofDG Set AMF panel fromRelay and auxilliary contacts complete by using 2.5 sq.mm copper cable of colour code from auxilliary contactsto Realyincluding fault findingetc all as specified and as directed.
249M&L for Overhauling of water pump with repairing kit for 63/100 kVA DG set complete all as directed.
250M&L for Overhauling of water pump with repairing kit for 160/250 kVA DG set complete all as directed.
251M&L for complete checking of AMF panel,finding the fault, servicing complete including replacement of unserviceable spares and testing complete for manual & Auto operations all as directed. Note: Supply only of new items required for replacement will be measured & paid seperately under respective item of schedule.
252Supply only AMF Relay.
253Supply only single phase preventor.
254Supply only PLA relay.
255Supply only 3 pole power Contractor ML-4, 70 A, 415 V. Make: L&T/Legrand
256S&F in repair HRC Fuse base of capacity 200 Amps.
257Supply only 3 pole power Contractor ML-4, 163 A, 415 V. Make: L&T/Legrand
258S & F Anti vibration pad set suitable for 63/ 100kVA DG set all as directed.
259M&L for taking out alternator of DG set of capacity 15 kVA (Make: Kirloskar) by dismantling from engine pulley including disconnecting electrical connection complete & transporting to workshop. Opening the rotor and stator for rewinding with copper wire of existing guage and then revarnishing the stator & rotor with good quality varnish, Heating and baking complete upto requisite duration. Check bearing & shaft for machining if reqd. Re-assemble stator & rotor by replacing existing bearings with new bearings complete. Retransportation alternator to base and coupled with engine by using new rubber bushing spider, nutbolts complete. Testing the system for smooth functioning & checking current and load output by giving existing electrical load and to the entire satisfaction of engr in charge.
260All same as per item No. 259 here-in-above, but for DG set of capacity 40 kVA Make: Kirloskar
261All same as per item No. 259 here-in-above, but for DG set of capacity 63 kVA Make: Greaves
262All same as per item No. 259 here-in-above, but for DG set of capacity 100 kVA Make: Greaves
263M&L for Readymade electrolyte having specific gravity 1.4 for DG set of any capacity all as directed.
264M&L for Distilled water having specific gravity 1.0 for DG set of any capacity all as directed.
265S&F in repair MCCB thermal magnetic protection unit rating 160 Amp, 4 pole, 25 kA type DPX3 in existing panel boards connecting with proper size link set at incoming and outgoing cable end with cable connections and ncluding necessary addition / alteration to existing panel with welding cutting to steel structure and providing new steel items complete all as specified.Make:Legrand Cat No. 4200 57 or equivalent in ABB / Siemens/ L&T
266S&F in repair MCCB thermal magnetic protection unit rating 100 Amp, 4 pole, 25 kA type DPX3 in existing panel boards connecting with proper size link set at incoming and outgoing cable end with cable connections and ncluding necessary addition / alteration to existing panel with welding cutting to steel structure and providing new steel items complete all as specified. Make:Legrand Cat No. 4200 55 or equivalent in ABB / Siemens/L&T
267Sevicing, repair, maintenance and attending complaint/ faults to the Fire Fighting and Fire alarm system including Fire Alarm Control Panel, Pre Alarm Action, Programmable detector sensivity, Device type verification, Earth fault annuciation facility at 0 ohms, Double Address Sensing, Loop wise divice test, 40 x 4 Characters LCD display 2 numbers of loop card and 200 devices in any combination per loop. Day/ Night Mode facility, USB 2.0 interface for PC connetivity RS 485 Communication facility for network/ Repeater/ MODBUS/ BACnet. Programmable Auto Silence Facility, Programmable AC Loos delay. Programmable Silence Inhibit. Two Nos. of programmable inputs, Battery low audio, visual warning, Three programmable Form C relay for Fire, Fault and Supervisory maintenance complete all as directed. Note: (i) New spare parts will be measured and paid separetely.
268Supply, commissioning and testing of Smoke detector Operating Voltage Range: 9 to 32 VDC Volts Non-polarized Standby Current: =100µA @ 24 VDC, Maximum Alarm Current (LED on ): =55mA @ 24 VDC, Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing, Operating Temperature Range: 14°F to 120°F (-10°C to 49°C), Adjustable Sensitivity: 1-2.5%/FT, Height: 2.2 (55 mm) installed in Base including taking down old unserviceable smoke detector complete all as specified and as directed.
269S&F in repair of Batteries DC, 12V, 7 AH, lead acid duly initial charged complete all as specified and as directed. Make: Exide / Star Gold
270Supply, commissioning and testing of Fire Alarm Hooter made out of iron, red colouroperatingvoltage 24 DC supplyDimensions (L x B x H): 18.5cm x 13 cm x 7.5 cm including taking down existing fire alarm hooter complete all as specified and directed.
271Supply, commissioning and testing of Addressable manual call point resettable type including taking down existing addressable maual call point complete all as specified and as directed.
272S&F in repair of Hydrant valve single headed Gun metal landing valve (internal/external Fire-Hydrants) with oblique type single outlet complete with hose coupling adaptor of 63 mm size, instantaneous spring lock arrangement and blank cap with chain conforming to IS 5290 complete all as directed
273S&F in repair of Flanged stand post CI of 80 mm dia 1.5 m height complete all as directed