95 / 22-23-Conversion Of Pnt To Piped Water Supply Scheme Rewai, Tehsil Bari To Provide Fhtcs Including One Year Defect Liability Period Under Block Bari Under Jjm In The Jurisdiction Of Phed Division Bari Distt. Dholpur., bharatpur-Rajasthan

Public Health Engineering Department-PHED has published 95 / 22-23-Conversion Of Pnt To Piped Water Supply Scheme Rewai, Tehsil Bari To Provide Fhtcs Including One Year Defect Liability Period Under Block Bari Under Jjm In The Jurisdiction Of Phed Division Bari Distt. Dholpur.. Submission Date for this Tender is 01-11-2022. Pipe Laying Tenders in bharatpur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

34098463
95 / 22-23-Conversion Of Pnt To Piped Water Supply Scheme Rewai, Tehsil Bari To Provide Fhtcs Including One Year Defect Liability Period Under Block Bari Under Jjm In The Jurisdiction Of Phed Division Bari Distt. Dholpur.
Open Tender
Indian
Rajasthan
bharatpur
01-11-2022

Tender Details

95 / 22-23-Conversion Of Pnt To Piped Water Supply Scheme Rewai, Tehsil Bari To Provide Fhtcs Including One Year Defect Liability Period Under Block Bari Under Jjm In The Jurisdiction Of Phed Division Bari Distt. Dholpur.

Key Value

Document Fees
INR 3000 /-
EMD
INR 441040.0 /-
Tender Value
INR 2.20 Crore /-

BOQ Items

Name of Work: Conversion of P&T to piped WSS Rewai, Tehsil Bari to provide FHTCs including one year Defect Liability Period under Block Bari under JJM in the jurisdiction of PHED Division Bari Distt. Dholpur.
Sl. No. Item Description
1Tube Well
2Construction of tube well from ground level & up to 100 mtr depth to accommodate housing and assembly pipe of following sizes in all type of alluvium strataunconsolidated formation such as pebbles, boulders etc. by percussion/rotary drilling method as per IS:2800 Part 1: 1991 andIS:2800 Part II: 1979 (both amended upto date) and technical specifications, with gravel as per IS:4097-1967 and it"s packing as per IS: 2800 (Part I & II) 1979 as amended up to date (the work includes the cost of gravel & it"s primary packing and packing during development, lowering of housing & strainer assembly pipes with supply and wrapping of coir-rope, wherever necessary for arresting fine sand particles and development work, but excluding the cost of housing and strainer pipe assembly). The work would be completed after obtaining sand free water. Nominal bore 200 mm dia.
3Construction of tube well after completion of item no. 2.1 & upto 100 mtr. depth and above in all type of rocks by DTH system as per IS : 2800 (Part I & II) 1979 as amended up to date. The work would be completed after obtaining sand free water. The tube well should have a throughout bore as per nominal bore of casing pipe. 200 mm Nominal Bore
4Add 15% extra on above item(Item No 2.2.1 to 2.2.2) for drilling depth beyond 100 mtr, rate shall be applicable for only extra depth beyond 100 mtr .
5Testing vertically of tube well by plumbing and yield test and drawdown test by pumping system as per Is 2800 (Part II) 1979
6Development of tube well as per IS: 11189- 1985 and IS: 2800 (Part- 1)-1991 (both amended up to date) using suitable compressor to give sandfree water for required yield of the gravel packed tube well.
7Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to dateoffollowing sizes . 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m)
8Supply & Fixing tube well coverof MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug. 200 mm dia
9Labour charges for making slots on blank pipes made of ERW MS black pipe ISI marked of following sizes, the slotting should be as per IS:8110-1985. 200 mm dia nominal bore of 5.4mm thickness
10Supply & Installation of 3 phase ISI marked submersible motor pump set ofthree star or better rating of BEEand as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. 7.5 KW (10.0 HP) & head above 120 mtr.
11Supply & Fixing of ISI marked three core PVC flat submersible cableas per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980including making connection etc. 3 core 6.0 Sq.mm
12Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved makein ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick underlayer ofsand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size. 16.0 Sq.mm, 4 core
13Providing & Lowering in tubewell lSI marked HDPE pipe as per IS 4984: 1995 or amended upto date in PE 80 grade and class PN 10 of following dia. including HOPE/GI fittings and PVC rope confirming to IS 5175:1992 or amended upto date, along with clamping of submersible cable etc. complete in all respect. 75 mm OD ( 63 mm ID)
14Providing & laying ISI marked GI Pipe Light duty ( “A” class) as perIS: 1239for casing pipe for submersible cable external work 40 mm dia complete in all respect.
15Providing & Fixing of double flanged, CI body, ISI marked NRV of approved make of following sizes. 80 mm Dia
16Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirfing to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsersion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.Manually Operated CI Sluice valve of Class PN-1.0. 80 mm HW
17Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg.including all jointing material as per specification with safety cover.
18Providing, installing, testing and commissioning of double flanged bulk flow meter with removable mechanism, of class B conforming to ISO 4064/1 or amended upto date of approved make including cost of all material andlabouras per specifications with GI Box (sheet 16 SWG) suitable with locking arrangement of following dia.80 mm dia
19Supply and Fixing of electric control feeder panel comprising of suitable rating MCCB , fully automatic star-delta starter, over load relay,ampere meter with CTs, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. The panel should have space for energy meter ( supplied by DISCOM).All these equipments shall be housed by panel box made out from 18 gauge M.S. Sheet with powder coating. Panel should be ofminimum size 900 x 600 x 450 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system.The legs should be embedded in M-15 cement concrete plat form. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The panel should have opening of suitable size in front of space for energy meter with glass for meter reading. The operation of panel should be suitable for on 440 Volt AC Supply. Above 5 HP and up to 10 HP
20Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20 mm dia. G.I. "B" class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C.finished chamber covered with hinged type with locking arrangement C.I. Cover,C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.
21Providing & Fixing pump safety cage as per specifications or as directed by Engineer in charge.
22Providing & Lowering in tubewell ISl marked GI Pipe "B" class as per IS: 1239 or amended up to date threaded and double flanged (welded) on both ends and two number 25 x 3 mm flat welded on both ends between pipe & flange, rubber washer & nut bolts etc. complete in all respect. 80 mm
23Rising Main
24Providing, lowering, laying and jointing in trenches,  standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M. HDPE PE-80PN-10 90 mm dia
25Providing, lowering, laying and jointing in trenches,  standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply of pipe shall be in straight length in 6/12 M. HDPE PE-80PN-10 140 mm dia
26Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.: All kinds of soil
2790 mm dia HDPE PE 80 PN 10
28140 mm dia HDPE PE 80 PN 10
29Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.
30Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work.M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).
31DISTRIBUTION PIPE LINE
32Providing, lowering, laying and jointing in trenches,  standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe byelectro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M. M. HDPE PE-80PN-06
3375 mm dia
3490 mm dia
35110 mm dia
36Providing, lowering, laying and jointing in trenches,  standard lengths HDPEISI marked Pipes as per IS-4984: 1995 (amended upto date)with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work). Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply of pipe shall be in straight length in 6/12 M. M. HDPE PE-80PN-6
37125mm dia
38140 mm dia
39160 mm dia
40180mm dia
41Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirfing to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsersion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.. Manually Operated CI Sluice valve of Class PN-1.0
4280 mm HW
43100 mm HW
44125 mm HW
45150 mm HW
46Demolishing and Earth Work
47Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.: All kinds of soil
4875 mm dia HDPE pipes
4990 mm dia HDPE pipes
50110 mm dia HDPE pipes
51125 mm dia HDPE pipes
52140 mm dia HDPE pipes
53160 mm dia HDPE pipes
54180 mm dia HDPE pipes
55Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.
56Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work.M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).
57PUMPING MACHINERY FOR CWR
58Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at syncronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected onC.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD. Centrifugal Monoblock Pump set (Single Stage) 7.5 KW (10 HP)
59Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depths in trenches complete includingall taxes, material,labour, inside lining, outside coating, testingandcommissioning alongwithpipelineaspertechnicalspecifications anddirection of Engineer-in-charge. MS pipespecialsupto600mmdia (withminimum5mmthickness sheet)
60Providing, lowering, aligning, fixing in position in pipe line, DI D/F resilient seated (soft seated) Swing type Non Return Valve of approved make of following Pressure rating & dia complete, generally confirming to IS: 5312 (part -1)/ 2004 (amendedup to date) and of following specifications: Body, Bonnet & disc of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions,Face to face dimensions as per IS 5312 (part -1):2004Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body, cover and disc inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS.Shaft of SS- AISI- 410, Hinge SS AISI 316/410 ,Bonnet Gasket EPDM ,Bush- Brasswith EPDM/NBR "O "ring seal Nut-Bolt confirming to IS:1363 and IS: 1367 (galvenised steel)Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Class PN 1.6 100 mm dia
61Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specificationscompleteofthefollowingsizesincludingall jointing material,costofalllabour,testingandcommissioning Technical Specifications and as per direction of Engineer. Class PN 1.0 100 mm dia.
62Providing, lowering, aligning, fixing in position in pipe line, CI double flanged Dual plate check valve of approved make of following Pressure rating & dia complete, as per API: 594/ API: 598 and of following specifications: Body & Cover of Grey cast iron of IS:210/ FG200 , Disc / plates - Cast steel ,Disc seal ring of EPDM/ NBR (food grade quality), Body seat of SS ,Face to face dimensions as per API: 594, Flanges Drilled as per IS:1538. All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan conforming toType B of IS:341or paint conforming to IS:9862 or IS:2932( Non-Toxic- suitable for drinking water) applied inside and outside. Shaft/Stop Pin of SS- AISI- 304/410 , Hinge SS AISI 316/304 / CS ,Spring SS AISI 316/304 , Bonnet Gasket EPDM, Bush- Brass with EPDM/NBR "O "ring seal.Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) ,Insersion rubber of black EPDM 6mm thick . Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Class PN 1.0 100 mm dia
63SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) ,Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304,Electrode : SS AISI 316L /Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection with existing pipeline including cutting the existing pipeline etc. complete in all respect as per technical specification and as per direction of Engineer In-Charge. Note: Rates are exclusive of tail piece / dismantling joints and earth work. EFM 150 mm
64STAR DELTA STARTER 7.5 KW (10.0 HP)- : For 2 motors(1 W+ 1S) I/C -MCB 63A ,FP, 10 KA, C Curve (1) , Analog Voltmeter 96*96mm ( 0-500V ) (1), Volt Selector Switch (1) , Analog Ammeter 96*96mm ( 0-60A ) (1), Amp. Selector Switch (1), C. T. 60/5A CL 1.0 5VA (3) , Indicating Lights ( Red-1, Yellow -1) (2), Indicating Lights ( Blue - 1 ) (1), Control MCB 6A SP 10 KA C Curve (3) and O/G-MCB 32A ,TP, 10 KA, C Curve (2), Power Cont 18A TP AC3 Duty(2), 2 NO+2 NC Aux. Block(2), Thermal Overload Relay (7-10A )(2), Control MCB 6A SP 10 KA C Curve (2), Single Phase Priventer (2), Indicating Lights (Red- 1, Green - 1, Amber-1)(6), Push Button 22.5 ( Red - 1, Green - 1 )(4), Selector Switch 1 Pole, 2 Way (2), Capacitor 440VAC Heavy Duty MPP Type 5Kvar (2), S/D Timer(2)
65Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg.including all jointing material as per specification with safety cover.
66Providing,lowering, aligning,fixingin positionin pipeline,CID/FSluicevalvesstraight and pocket less body passage of approved make of following Pressure rating & dia complete, confirfing to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS, Face to face dimensions as per IS 14846/2000 (amended up to date) ,Epoxy ( Non-Toxic- suitable for drinking water) applied inside and outside,Flanges Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steelInsersion rubber of black EPDM 6mm thick . Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.. Manually Operated CI Sluice valve of Class PN-1.0 100 mm HW
67RCC
68Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: -a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc. c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR.The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall. e)Conducting successfully hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome. g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc.. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab. j) Providing and fixing water level indicator (float type). k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres. l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide. m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall). n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground. o) Lighting arrestor consisting of providing and fixing of 2 Nos.of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm. p) CI/DI puddle collar shall be fixed in the bottom dome/ slab for connecting inlet, outlet, overflow and washout pipe of the reservoir. q) Painting the name of the scheme and other details on the reservoir, and any other work related to structure as per the directions of Engineer-in- Charge, Technical Specification and Scope of Work. r) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. 250 KL capacity, stagging 18 Mtr., Zone 2
69Construction of RCC (Flat slab type) Clear Water Reservoir of following capacity as per the Scope of work and Technical specification, consisting of the following main activities: -a) Topographic survey, preparation of site contour plan, conducting SBC testand its approval from departmentbefore construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation & all RCC Work including all labour and material charges including providing and fixing of accessories such as SS ladder, SS manhole frame and covers, water level indicator (float type), SS ventilator with SS screen, float valve, puddle collars, G.I. pipe railing around walk way, Top Dome/Slab, Staircase. c) CWR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the vertical wall of CWR. The plinth protection shall consist of 150mm thick PCC in M-15 concrete over 150mm thick compacted soil fill. d) Providing and applying two coats of food grade epoxy paint on the inside surface of the roof slab, and 600 mm height of the vertical wall. e) Successful hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the roof Slab. g) Providing and applying three coats of cement-based paint on the remaining external surface area of the structure. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS 304 ladder from roof slab to bottom Slab, inside container. Providing and fixing water level indicator (Float type). i) Providing and fixing MS ladder from ground to top slab. j) All MS parts to be painted with two coats of the enamelled paint over the primer coat of red oxide. k) Providing and fixing of 150mm wide water bar for the construction joints in the container. l) Providing and fixing CI/DI puddle collars the vertical wall for connecting inlet, outlet, overflow and washout pipes of the reservoir. m) Inlet, outlet, overflow, washout pipes and valves are not included in this work, provision for the same shall be taken separately. Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2,3 & 4 75KL Capacity
70Providing and fixing double flanged ISI marked DIClass K-9 pipes as per IS:8329-2000 (amended up to date), asvertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr,jointing materials such as nuts, bolt, rubber packing, hydraulic testingetc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.
71150 mm dia ( DistributionPipe Line & By Pass Pipe Line)
72150 mm dia ( RaisingPipe Line & Over Fiow Pipe Line)
73100 mm dia ( Drain Out Pipe Line)
74Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirfing to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS (AISI 316 or equivalent) Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insersion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. Manually Operated Resilient Seated Sluice Valves of Class PN 1.6
75150 mm dia ( DistributionPipe Line & By Pass Pipe Line)
76150 mm dia (Rising Pipe & Over Flow pipe line)
77Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specificationscompleteofthefollowingsizesincludingall jointing material,costofalllabour,testingandcommissioning Technical Specifications and as per direction of Engineer. Class PN 1.0 150 mm dia
78Provision for DI/CI/MS specials such as Tee, Bends, Reducer, MS clamp, Valves tail piece etc.
79Civil Work PUMP HOUSE
80Construction of Pump house of required size suitable for installation of maximum 4 no. monoblock pump sets as per approved GA drawing, scope of work and technical specification complete work in all respect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement.
81Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamel paints.
82Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below: 1. Depth of foundation- 900 mm. 2. PCC in M-10, width -900 mm and thickness 100 mm, 3. Section of foundation above PCC W-600 mm, D-450mm, W- 450mm, D-450 mm. 4. Superstructure work: Stone masonary W-300, height-1650 mm,/ Brick work W-230 mm, height- 1650 mm. 5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6. 6. Expansion joint shall be on every 30 mtr. 7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided. 8. Pillar for main gate 350x350 mm in size is part of boundary wall. 9. Cement paint of approved colour in 3 coat shall be done.
83FHTC
84Providing Household Tap Connectionas per technical specification andapproved drawing as per relevant IS code (amended up to date) from HDPE pipe line up to consumer meter/premises by using electro fusion saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance withspecification for potable water including electrofusion saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valvevalveand specials with 20 mm nominal dia MDPE pipe PE80 PN 16 as per ISO 4427 / 20 mm nominaldia PPR-C (Three layered) pipePN16 SDR 7.4 (IS:15801:2008) (ISI mark) and above ground level using PPR-C pipe with standard PPR fittings/ GI pipes in the premises for fixing a tap / meterbox (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level. Note: Road cut and restoration is not part of this item and paid seperately. For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr. Extra length of 20 mm MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr. P& F Bib cock (IS : 8931 mark), superior quality of approved make , brss 400 gm, 15 mm nominal bore.
85Data entryof existing FHTCs in rural area under JJM on website ejalshakti.gov.in;work includes visiting the village for collecting basic data consumers like i.e.adhar no/tation card/voter id /BPL card /Driving licence/password/PAN card /any data card/mobile no.etc.and entering the details on the above website. The cost also includes computer and operater.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail